diff --git a/patient-monitor-simulation-v0.3.1-to-v0.3.2.patch b/patient-monitor-simulation-v0.3.1-to-v0.3.2.patch new file mode 100644 index 0000000..306ebbe --- /dev/null +++ b/patient-monitor-simulation-v0.3.1-to-v0.3.2.patch @@ -0,0 +1,526 @@ +--- a/Cargo.toml ++++ b/Cargo.toml +@@ -1,6 +1,6 @@ + [package] + name = "patient-monitor-simulation" +-version = "0.3.1" ++version = "0.3.2" + edition = "2021" + license = "MIT" + description = "Synthetic patient-monitor simulation for teaching (not for clinical use)" +--- a/README.md ++++ b/README.md +@@ -1,4 +1,4 @@ +-# Patient Monitor Simulation (PaMSim) — v0.3.1 ++# Patient Monitor Simulation (PaMSim) — v0.3.2 + + A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux. + +@@ -20,14 +20,17 @@ + + ## Windows + +-**Admin:** Controls ECG rhythm and rate; mechanical capture; SpO₂; invasive +-arterial pressure, waveform shape and pulse-pressure variation; NIBP; and +-capnography. Numeric inputs have bidirectionally linked sliders and text fields. ++**Admin:** Controls patient name; ECG rhythm and rate; mechanical capture; ++SpO₂, signal quality and sensor connection; invasive arterial pressure, ++waveform shape and pulse-pressure variation; NIBP; and capnography. Numeric inputs have bidirectionally linked sliders and text fields. + Each of the five monitor parameters (ECG, SpO₂/pleth, ART, CO₂, NIBP) has its + own **Show on monitor** checkbox. + + **Monitor:** Black background; ECG green, pleth yellow, ART red and capnogram +-light grey. Waveforms and vital signs disappear together when their respective ++light grey. The patient name entered in Admin replaces **PATIENT MONITOR** in ++the header immediately; leaving the name blank restores the generic title. ++Long names are automatically resized or clipped to fit the header. ++Waveforms and vital signs disappear together when their respective + visibility checkbox is cleared. Remaining waveform rows expand to use the space. + Hiding a display channel does **not** stop signal generation or physiological + coupling: for example, hiding ECG does not stop ART or pleth pulses. NIBP can +@@ -36,6 +39,41 @@ + The monitor can be resized and toggled fullscreen with **F11**; **Esc** exits + fullscreen. On Wayland, move the monitor to the presentation screen before + activating fullscreen. Fullscreen does not lock down the computer. ++ ++## Patient name and pulse oximeter signal state (new in v0.3.2) ++ ++The new **Patient name** text field at the top of Admin immediately replaces the ++monitor headline. It is optional; an empty or whitespace-only name displays ++**PATIENT MONITOR**. This is a local teaching label, not a patient record. ++ ++Admin → **Pulse oximetry** has two additional controls: ++ ++- **Sensor not attached** (checkbox): immediately removes the pleth waveform, ++ suppresses SpO₂ and pulse-rate readings, and displays **NO SENSOR** instead ++ of the numeric saturation. This takes precedence over signal quality. ++- **Signal quality** (dropdown), which changes the visible pleth waveform and ++ quality indicator, independently of the instructor-set SpO₂ percentage: ++ ++| Setting | Pleth waveform | Monitor display | ++| --- | --- | --- | ++| **0 — None** | No waveform | SpO₂ `--`, PR `--`, **NO SIGNAL**; no stars | ++| **1 — Poor** | Small, irregularly amplitude-distorted pulse | 1 star (★) | ++| **2 — Adequate** | Medium, smoothly damped pulse | 2 stars (★★) | ++| **3 — Good** | Full nominal, smoothly damped pulse | 3 stars (★★★) | ++ ++Default: sensor attached; signal quality **3 — Good**. At levels 1–3, the ++instructor-set SpO₂ number is shown only when mechanical pulses are detected. ++The signal quality does **not** randomly alter that number: it affects the ++pleth morphology and the quality indicator only. The simulated pulse rate ++remains derived from mechanically captured QRS complexes. ++ ++The degraded waveform uses deterministic, smoothly interpolated pseudo-noise ++that scales only existing pleth pulses: it cannot manufacture pulses during ++PEA, ventricular fibrillation or asystole. Unplugging a sensor or selecting ++quality 0 hides even previously buffered pleth samples immediately. ECG and ++ART continue unaffected. The **Show on monitor** checkbox still hides the ++entire SpO₂ row; sensor/quality controls leave the row visible so the status ++can be taught. + + ## ECG and mechanical coupling + +@@ -161,3 +199,17 @@ + **Verification:** The archive is generated from these sources. Run `cargo test` + locally to verify the Rust/GTK build; Rust and GTK4 development components + were not available in the environment where this ZIP was prepared. ++ ++## Changes in v0.3.2 ++ ++1. Added live patient-name header in Admin/Monitor with blank-name fallback. ++2. Added four levels of SpO₂ signal quality, quality stars and an irregular, ++ low-amplitude pleth waveform for Poor quality. ++3. Added **Sensor not attached** with `NO SENSOR` status and suppression of ++ saturation, pulse rate and pleth waveform. ++4. Added tests for signal-quality scaling, displayed readings and disconnected ++ sensor behavior. ++ ++**Build verification:** ZIP integrity and patch application were checked. ++The GTK4 application and Rust tests were not compiled in the packaging ++environment; run `cargo test` and `cargo run --release` on Fedora. +--- a/src/model.rs ++++ b/src/model.rs +@@ -58,12 +58,45 @@ + Obstructive, + } + +-#[derive(Clone, Copy, Debug)] ++/// Instructor-selected plethysmography signal quality; separate from the ++/// physiological oxygen-saturation setting and mechanical pulse capture. ++#[derive(Clone, Copy, Debug, PartialEq, Eq)] ++pub enum Spo2Quality { ++ None, ++ Poor, ++ Adequate, ++ Good, ++} ++ ++impl Spo2Quality { ++ pub fn stars(self) -> &'static str { ++ match self { ++ Self::None => "", ++ Self::Poor => "★", ++ Self::Adequate => "★★", ++ Self::Good => "★★★", ++ } ++ } ++ ++ pub fn amplitude_scale(self) -> f64 { ++ match self { ++ Self::None => 0.0, ++ Self::Poor => 0.25, ++ Self::Adequate => 0.56, ++ Self::Good => 1.0, ++ } ++ } ++} ++ ++#[derive(Clone, Debug)] + pub struct Parameters { ++ pub patient_name: String, // displayed in the monitor header, blank = generic title + pub ecg_rhythm: EcgRhythm, + pub heart_rate: i32, // bpm, organized electrical rate; not mechanical pulse rate + pub pulse_conduction: PulseConduction, +- pub spo2: i32, // % ++ pub spo2: i32, // %; instructor-set nominal saturation ++ pub spo2_quality: Spo2Quality, ++ pub spo2_sensor_attached: bool, + pub art_systolic: i32, // mmHg, nominal pressure; display axis 0..200 + pub art_diastolic: i32, // mmHg + pub arterial_shape: ArterialShape, +@@ -84,10 +117,13 @@ + impl Default for Parameters { + fn default() -> Self { + Self { ++ patient_name: String::new(), + ecg_rhythm: EcgRhythm::Sinus, + heart_rate: 75, + pulse_conduction: PulseConduction::OneToOne, + spo2: 98, ++ spo2_quality: Spo2Quality::Good, ++ spo2_sensor_attached: true, + art_systolic: 120, + art_diastolic: 75, + arterial_shape: ArterialShape::Normal, +@@ -120,6 +156,17 @@ + } + + #[test] ++ fn spo2_quality_stars_and_amplitude_progress_monotonically() { ++ assert_eq!(Spo2Quality::None.stars(), ""); ++ assert_eq!(Spo2Quality::Poor.stars(), "★"); ++ assert_eq!(Spo2Quality::Adequate.stars(), "★★"); ++ assert_eq!(Spo2Quality::Good.stars(), "★★★"); ++ assert_eq!(Spo2Quality::None.amplitude_scale(), 0.0); ++ assert!(Spo2Quality::Poor.amplitude_scale() < Spo2Quality::Adequate.amplitude_scale()); ++ assert!(Spo2Quality::Adequate.amplitude_scale() < Spo2Quality::Good.amplitude_scale()); ++ } ++ ++ #[test] + fn grouped_mechanical_capture_follows_requested_patterns() { + assert_eq!((1..=8).filter(|&b| PulseConduction::TwoToOne.conducts(b)).collect::>(), + vec![1, 3, 5, 7]); +--- a/src/render.rs ++++ b/src/render.rs +@@ -1,7 +1,7 @@ + //! Size-independent Cairo drawing of the synthetic bedside monitor. + use gtk::cairo::{Context, FontSlant, FontWeight, LineCap, LineJoin}; + +-use crate::model::{mean_arterial_pressure, EcgRhythm, Parameters, PulseConduction}; ++use crate::model::{mean_arterial_pressure, EcgRhythm, Parameters, PulseConduction, Spo2Quality}; + use crate::simulation::{Sample, Simulator}; + + type Color = (f64, f64, f64); +@@ -43,8 +43,18 @@ + let trace_right = (split_x - pad).max(trace_left + 40.0); + let text_scale = (w.min(h * 1.7) / 850.0).clamp(0.65, 1.5); + +- text(cr, "PATIENT MONITOR", pad + 5.0, header * 0.58, 18.0 * text_scale, +- LIGHT_GREY, true); ++ let patient_title = if p.patient_name.trim().is_empty() { ++ "PATIENT MONITOR" ++ } else { ++ p.patient_name.trim() ++ }; ++ let title_max_width = if w >= 850.0 { ++ split_x - pad * 2.0 - 145.0 * text_scale ++ } else { ++ split_x - pad * 2.0 ++ }; ++ fitted_text(cr, patient_title, pad + 5.0, header * 0.58, ++ 18.0 * text_scale, title_max_width.max(25.0), LIGHT_GREY); + if w >= 850.0 { + text(cr, "SIMULATION", split_x - 128.0 * text_scale, header * 0.58, + 11.0 * text_scale, MUTED, false); +@@ -84,6 +94,24 @@ + } + } + ++fn pleth_trace_enabled(p: &Parameters) -> bool { ++ p.spo2_sensor_attached && p.spo2_quality != Spo2Quality::None ++} ++ ++fn spo2_vitals(p: &Parameters, pulse_rate: Option) -> (String, String, String) { ++ if !p.spo2_sensor_attached { ++ return ("SpO₂".to_owned(), "NO SENSOR".to_owned(), "SpO₂ -- PR -- bpm".to_owned()); ++ } ++ if p.spo2_quality == Spo2Quality::None { ++ return ("SpO₂".to_owned(), "--".to_owned(), "NO SIGNAL PR -- bpm".to_owned()); ++ } ++ ( ++ format!("SpO₂ {}", p.spo2_quality.stars()), ++ if pulse_rate.is_some() { p.spo2.to_string() } else { "--".to_owned() }, ++ format!("% PR {} bpm", pulse_rate.map_or("--".to_owned(), |pr| pr.to_string())), ++ ) ++} ++ + fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64, + top: f64, row_h: f64, width: f64, p: &Parameters, sim: &Simulator) { + let label_size = (row_h * 0.135).clamp(11.0, 19.0); +@@ -95,7 +123,7 @@ + let pulse_rate = if has_capture { sim.pulse_rate() } else { None }; + let (label, value, info) = match ch { + Channel::Ecg => ( +- "HR", ++ "HR".to_owned(), + if !p.ecg_rhythm.has_qrs() || p.heart_rate <= 0 { "--".to_owned() } + else { p.heart_rate.to_string() }, + format!("bpm · {}", match p.ecg_rhythm { +@@ -106,13 +134,9 @@ + EcgRhythm::Asystole => "Asystole", + }), + ), +- Channel::Pleth => ( +- "SpO₂", +- if pulse_rate.is_some() { p.spo2.to_string() } else { "--".to_owned() }, +- format!("% PR {} bpm", pulse_rate.map_or("--".to_owned(), |pr| pr.to_string())), +- ), ++ Channel::Pleth => spo2_vitals(p, pulse_rate), + Channel::Art => ( +- "ART", ++ "ART".to_owned(), + if pulse_rate.is_some() { + format!("{}/{}", p.art_systolic, p.art_diastolic) + } else { "--/--".to_owned() }, +@@ -126,13 +150,20 @@ + } + } else { "MAP -- mmHg".to_owned() }, + ), +- Channel::Capno => ("EtCO₂", p.etco2.to_string(), ++ Channel::Capno => ("EtCO₂".to_owned(), p.etco2.to_string(), + format!("mmHg RR {} /min", p.respiratory_rate)), + }; +- text(cr, label, x, top + row_h * 0.24, label_size, color, false); +- // Reduce wide BP values so they fit within the sidebar. +- let value_size = if matches!(ch, Channel::Art) { number_size * 0.78 } else { number_size }; +- text(cr, &value, x, top + row_h * 0.64, value_size, color, true); ++ text(cr, &label, x, top + row_h * 0.24, label_size, color, false); ++ // Reduce wide readings so they fit within the sidebar. ++ let value_size = if value == "NO SENSOR" { ++ number_size.min(0.19 * width).min(26.0) ++ } else if matches!(ch, Channel::Art) { ++ number_size * 0.78 ++ } else { ++ number_size ++ }; ++ fitted_text(cr, &value, x, top + row_h * 0.64, value_size, ++ width.max(20.0), color); + text(cr, &info, x, top + row_h * 0.87, sub_size * 0.85, color, false); + } + +@@ -175,6 +206,13 @@ + right, top + trace_height * 0.5, GRID, 0.7); + } + ++ // Disconnected or absent pleth signal: no curve, including historical pulses. ++ if matches!(channel, Channel::Pleth) && !pleth_trace_enabled(p) ++ { ++ let _ = cr.restore(); ++ return; ++ } ++ + set_color(cr, color); + cr.set_line_width((trace_height * 0.016).clamp(1.2, 2.4)); + cr.set_line_cap(LineCap::Round); +@@ -194,11 +232,66 @@ + fn normalized(channel: Channel, s: &Sample, p: &Parameters) -> f64 { + match channel { + Channel::Ecg => (0.40 + s.ecg * 0.38).clamp(0.02, 0.98), +- Channel::Pleth => (0.10 + s.pleth * 0.78).clamp(0.02, 0.98), ++ Channel::Pleth => (0.10 + pleth_visual_amplitude(s.pleth, s.time, p.spo2_quality) * 0.78) ++ .clamp(0.02, 0.98), + Channel::Art => (s.art / 200.0).clamp(0.0, 1.0), + Channel::Capno => (0.08 + (s.co2 / f64::from(p.etco2.max(1))) * 0.80) + .clamp(0.02, 0.98), + } ++} ++ ++/// Signal degradation is presentation-only: no quality setting can invent ++/// pulses or change the ECG/ART generator. The noise is smoothly interpolated ++/// and reproducible, so redrawing a sample does not make it flicker. ++fn pleth_visual_amplitude(pleth: f64, time: f64, quality: Spo2Quality) -> f64 { ++ let scale = quality.amplitude_scale(); ++ if scale == 0.0 || pleth <= 0.0 { return 0.0; } ++ let distortion = if quality == Spo2Quality::Poor { ++ (1.0 + 0.55 * smooth_noise(time * 7.0) ++ + 0.20 * smooth_noise(time * 23.0 + 4.0)).clamp(0.15, 1.75) ++ } else { ++ 1.0 ++ }; ++ (pleth * scale * distortion).clamp(0.0, 1.0) ++} ++ ++fn smooth_noise(position: f64) -> f64 { ++ let index = position.floor() as i64; ++ let fraction = position - index as f64; ++ let smooth = fraction * fraction * (3.0 - 2.0 * fraction); ++ let a = noise_value(index); ++ let b = noise_value(index.wrapping_add(1)); ++ a + (b - a) * smooth ++} ++ ++fn noise_value(index: i64) -> f64 { ++ let mut x = (index as u64).wrapping_mul(0x9E37_79B9_7F4A_7C15); ++ x ^= x >> 30; ++ x = x.wrapping_mul(0xBF58_476D_1CE4_E5B9); ++ x ^= x >> 27; ++ x = x.wrapping_mul(0x94D0_49BB_1331_11EB); ++ x ^= x >> 31; ++ (x as f64 / u64::MAX as f64) * 2.0 - 1.0 ++} ++ ++/// Fit a name or numeric/status reading horizontally without changing the ++/// other monitor dimensions. For exceptionally long values, clip safely. ++fn fitted_text(cr: &Context, value: &str, x: f64, baseline: f64, ++ nominal_size: f64, available_width: f64, color: Color) { ++ cr.select_font_face("Sans", FontSlant::Normal, FontWeight::Bold); ++ cr.set_font_size(nominal_size); ++ let actual_width = cr.text_extents(value).map(|ext| ext.x_advance()).unwrap_or(0.0); ++ let fitted_size = if actual_width > available_width && actual_width > 0.0 { ++ (nominal_size * available_width / actual_width).max(8.0) ++ } else { ++ nominal_size ++ }; ++ let _ = cr.save(); ++ cr.rectangle(x, baseline - fitted_size * 1.25, ++ available_width.max(1.0), fitted_size * 1.55); ++ cr.clip(); ++ text(cr, value, x, baseline, fitted_size, color, true); ++ let _ = cr.restore(); + } + + fn set_color(cr: &Context, c: Color) { +@@ -243,6 +336,53 @@ + } + + #[test] ++ fn pleth_degradation_preserves_capture_timing_and_suppresses_false_pulses() { ++ let pulse = 0.6; ++ let t = 1.234; ++ assert_eq!(pleth_visual_amplitude(pulse, t, Spo2Quality::None), 0.0); ++ assert_eq!(pleth_visual_amplitude(0.0, t, Spo2Quality::Poor), 0.0); ++ assert!(pleth_visual_amplitude(pulse, t, Spo2Quality::Poor) ++ < pleth_visual_amplitude(pulse, t, Spo2Quality::Adequate)); ++ assert!(pleth_visual_amplitude(pulse, t, Spo2Quality::Adequate) ++ < pleth_visual_amplitude(pulse, t, Spo2Quality::Good)); ++ assert_eq!(pleth_visual_amplitude(pulse, t, Spo2Quality::Good), pulse); ++ assert_eq!(pleth_visual_amplitude(pulse, t, Spo2Quality::Poor), ++ pleth_visual_amplitude(pulse, t, Spo2Quality::Poor)); ++ assert_ne!(pleth_visual_amplitude(pulse, t, Spo2Quality::Poor), ++ pleth_visual_amplitude(pulse, t + 0.5, Spo2Quality::Poor)); ++ } ++ ++ #[test] ++ fn disconnected_or_no_quality_means_no_pleth_or_spo2_reading() { ++ let mut p = Parameters::default(); ++ assert!(pleth_trace_enabled(&p)); ++ p.spo2_sensor_attached = false; ++ assert!(!pleth_trace_enabled(&p)); ++ assert_eq!(spo2_vitals(&p, Some(75)).1, "NO SENSOR"); ++ assert!(spo2_vitals(&p, Some(75)).2.contains("PR --")); ++ p.spo2_sensor_attached = true; ++ p.spo2_quality = Spo2Quality::None; ++ assert!(!pleth_trace_enabled(&p)); ++ assert_eq!(spo2_vitals(&p, Some(75)).1, "--"); ++ assert!(spo2_vitals(&p, Some(75)).2.contains("NO SIGNAL")); ++ assert!(spo2_vitals(&p, Some(75)).2.contains("PR --")); ++ assert!(p.show_spo2); // no readings, but visible row and status ++ } ++ ++ #[test] ++ fn poor_and_good_quality_keep_derived_pr_and_quality_indicators() { ++ let mut p = Parameters::default(); ++ p.spo2_quality = Spo2Quality::Poor; ++ assert_eq!(spo2_vitals(&p, Some(75)).0, "SpO₂ ★"); ++ assert_eq!(spo2_vitals(&p, Some(75)).1, "98"); ++ assert!(spo2_vitals(&p, Some(75)).2.contains("PR 75 bpm")); ++ p.spo2_quality = Spo2Quality::Good; ++ assert_eq!(spo2_vitals(&p, Some(75)).0, "SpO₂ ★★★"); ++ assert_eq!(spo2_vitals(&p, None).1, "--"); ++ assert!(spo2_vitals(&p, None).2.contains("PR --")); ++ } ++ ++ #[test] + fn arterial_axis_is_absolute_and_fixed_to_200_mmhg() { + let p = Parameters::default(); + let mut s = Sample { time: 0.0, ecg: 0.0, pleth: 0.0, art: 100.0, co2: 0.0 }; +--- a/src/ui.rs ++++ b/src/ui.rs +@@ -8,7 +8,7 @@ + use gtk::prelude::*; + use gtk::{Application, ApplicationWindow, Orientation}; + +-use crate::model::{ArterialShape, CapnoShape, EcgRhythm, Parameters, PulseConduction}; ++use crate::model::{ArterialShape, CapnoShape, EcgRhythm, Parameters, PulseConduction, Spo2Quality}; + use crate::render; + use crate::simulation::Simulator; + +@@ -41,7 +41,7 @@ + let params = params.clone(); + let simulator = simulator.clone(); + move |_area, cr, width, height| { +- let config = *params.borrow(); ++ let config = params.borrow(); + render::draw(cr, width, height, &config, &simulator.borrow()); + } + }); +@@ -54,7 +54,7 @@ + let now = Instant::now(); + let elapsed = now.saturating_duration_since(previous.get()).as_secs_f64(); + previous.set(now); +- let config = *params.borrow(); ++ let config = params.borrow(); + simulator.borrow_mut().advance(elapsed, &config); + area.queue_draw(); + glib::ControlFlow::Continue +@@ -104,6 +104,24 @@ + scroller.set_vexpand(true); + scroller.set_policy(gtk::PolicyType::Never, gtk::PolicyType::Automatic); + let controls = gtk::Box::new(Orientation::Vertical, 12); ++ ++ let patient = group(&controls, "Patient"); ++ let patient_row = gtk::Box::new(Orientation::Horizontal, 8); ++ let patient_label = gtk::Label::new(Some("Patient name")); ++ patient_label.set_xalign(0.0); ++ patient_label.set_width_chars(17); ++ let name_entry = gtk::Entry::new(); ++ name_entry.set_hexpand(true); ++ name_entry.set_max_length(80); ++ name_entry.set_placeholder_text(Some("Name displayed on monitor")); ++ name_entry.set_text(¶ms.borrow().patient_name); ++ name_entry.connect_changed({ ++ let params = params.clone(); ++ move |entry| params.borrow_mut().patient_name = entry.text().to_string() ++ }); ++ patient_row.append(&patient_label); ++ patient_row.append(&name_entry); ++ patient.append(&patient_row); + + let ecg = group(&controls, "ECG"); + add_visibility(&ecg, params.borrow().show_ecg, params.clone(), |p, show| p.show_ecg = show); +@@ -126,6 +144,26 @@ + add_visibility(&spo2, params.borrow().show_spo2, params.clone(), |p, show| p.show_spo2 = show); + add_numeric(&spo2, "SpO₂", "%", 0, 100, params.borrow().spo2, + params.clone(), |p, v| p.spo2 = v); ++ let sensor = gtk::CheckButton::with_label("Sensor not attached"); ++ sensor.set_active(!params.borrow().spo2_sensor_attached); ++ sensor.connect_toggled({ ++ let params = params.clone(); ++ move |button| params.borrow_mut().spo2_sensor_attached = !button.is_active() ++ }); ++ spo2.append(&sensor); ++ add_dropdown_at(&spo2, "Signal quality", &[ ++ "0 — None (no reading)", ++ "1 — Poor (*)", ++ "2 — Adequate (**)", ++ "3 — Good (***)", ++ ], params.borrow().spo2_quality as u32, params.clone(), |p, selected| { ++ p.spo2_quality = match selected { ++ 1 => Spo2Quality::Poor, ++ 2 => Spo2Quality::Adequate, ++ 3 => Spo2Quality::Good, ++ _ => Spo2Quality::None, ++ }; ++ }); + add_dropdown(&spo2, "Mechanical capture", &[ + "1:1 (every QRS)", + "2:1 (one pulse in two)", +@@ -243,11 +281,18 @@ + fn add_dropdown(parent: >k::Box, label: &str, items: &[&str], + params: SharedParams, setter: F) + where F: Fn(&mut Parameters, u32) + 'static { ++ add_dropdown_at(parent, label, items, 0, params, setter); ++} ++ ++fn add_dropdown_at(parent: >k::Box, label: &str, items: &[&str], ++ initial: u32, params: SharedParams, setter: F) ++where F: Fn(&mut Parameters, u32) + 'static { + let row = gtk::Box::new(Orientation::Horizontal, 8); + let caption = gtk::Label::new(Some(label)); + caption.set_xalign(0.0); + caption.set_width_chars(17); + let combo = gtk::DropDown::from_strings(items); ++ combo.set_selected(initial); + combo.set_hexpand(true); + combo.connect_selected_notify(move |combo| { + setter(&mut params.borrow_mut(), combo.selected()); diff --git a/patient-monitor-simulation/Cargo.lock b/patient-monitor-simulation/Cargo.lock index a61eef1..44f6dc7 100644 --- a/patient-monitor-simulation/Cargo.lock +++ b/patient-monitor-simulation/Cargo.lock @@ -438,7 +438,7 @@ dependencies = [ [[package]] name = "patient-monitor-simulation" -version = "0.3.0" +version = "0.3.2" dependencies = [ "gtk4", ] diff --git a/patient-monitor-simulation/Cargo.toml b/patient-monitor-simulation/Cargo.toml index 0dc2471..01db11b 100644 --- a/patient-monitor-simulation/Cargo.toml +++ b/patient-monitor-simulation/Cargo.toml @@ -1,6 +1,6 @@ [package] name = "patient-monitor-simulation" -version = "0.3.0" +version = "0.3.2" edition = "2021" license = "MIT" description = "Synthetic patient-monitor simulation for teaching (not for clinical use)" diff --git a/patient-monitor-simulation/README.md b/patient-monitor-simulation/README.md index 98b2eaf..a4be1bc 100644 --- a/patient-monitor-simulation/README.md +++ b/patient-monitor-simulation/README.md @@ -1,4 +1,4 @@ -# Patient Monitor Simulation (PaMSim) — v0.3.0 +# Patient Monitor Simulation (PaMSim) — v0.3.2 A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux. @@ -20,14 +20,17 @@ session (e.g., Fedora KDE/Wayland). ## Windows -**Admin:** Controls ECG rhythm and rate; mechanical capture; SpO₂; invasive -arterial pressure, waveform shape and pulse-pressure variation; NIBP; and -capnography. Numeric inputs have bidirectionally linked sliders and text fields. +**Admin:** Controls patient name; ECG rhythm and rate; mechanical capture; +SpO₂, signal quality and sensor connection; invasive arterial pressure, +waveform shape and pulse-pressure variation; NIBP; and capnography. Numeric inputs have bidirectionally linked sliders and text fields. Each of the five monitor parameters (ECG, SpO₂/pleth, ART, CO₂, NIBP) has its own **Show on monitor** checkbox. **Monitor:** Black background; ECG green, pleth yellow, ART red and capnogram -light grey. Waveforms and vital signs disappear together when their respective +light grey. The patient name entered in Admin replaces **PATIENT MONITOR** in +the header immediately; leaving the name blank restores the generic title. +Long names are automatically resized or clipped to fit the header. +Waveforms and vital signs disappear together when their respective visibility checkbox is cleared. Remaining waveform rows expand to use the space. Hiding a display channel does **not** stop signal generation or physiological coupling: for example, hiding ECG does not stop ART or pleth pulses. NIBP can @@ -37,6 +40,41 @@ The monitor can be resized and toggled fullscreen with **F11**; **Esc** exits fullscreen. On Wayland, move the monitor to the presentation screen before activating fullscreen. Fullscreen does not lock down the computer. +## Patient name and pulse oximeter signal state (new in v0.3.2) + +The new **Patient name** text field at the top of Admin immediately replaces the +monitor headline. It is optional; an empty or whitespace-only name displays +**PATIENT MONITOR**. This is a local teaching label, not a patient record. + +Admin → **Pulse oximetry** has two additional controls: + +- **Sensor not attached** (checkbox): immediately removes the pleth waveform, + suppresses SpO₂ and pulse-rate readings, and displays **NO SENSOR** instead + of the numeric saturation. This takes precedence over signal quality. +- **Signal quality** (dropdown), which changes the visible pleth waveform and + quality indicator, independently of the instructor-set SpO₂ percentage: + +| Setting | Pleth waveform | Monitor display | +| --- | --- | --- | +| **0 — None** | No waveform | SpO₂ `--`, PR `--`, **NO SIGNAL**; no stars | +| **1 — Poor** | Small, irregularly amplitude-distorted pulse | 1 star (★) | +| **2 — Adequate** | Medium, smoothly damped pulse | 2 stars (★★) | +| **3 — Good** | Full nominal, smoothly damped pulse | 3 stars (★★★) | + +Default: sensor attached; signal quality **3 — Good**. At levels 1–3, the +instructor-set SpO₂ number is shown only when mechanical pulses are detected. +The signal quality does **not** randomly alter that number: it affects the +pleth morphology and the quality indicator only. The simulated pulse rate +remains derived from mechanically captured QRS complexes. + +The degraded waveform uses deterministic, smoothly interpolated pseudo-noise +that scales only existing pleth pulses: it cannot manufacture pulses during +PEA, ventricular fibrillation or asystole. Unplugging a sensor or selecting +quality 0 hides even previously buffered pleth samples immediately. ECG and +ART continue unaffected. The **Show on monitor** checkbox still hides the +entire SpO₂ row; sensor/quality controls leave the row visible so the status +can be taught. + ## ECG and mechanical coupling - ECG rhythms: sinus, atrial fibrillation, monomorphic ventricular tachycardia, @@ -102,9 +140,31 @@ The five **Show on monitor** checkboxes affect the presentation only: Remaining visible waveforms keep their relative order and receive an equal share of the available area; zero waveform channels is supported. +## ECG morphology correction (v0.3.1) + +At high heart rates, the previous ECG generator expressed QRS width as a fixed +fraction of the R–R interval and sampled at 100 Hz. Narrow R waves could fall +between samples, making successive QRS complexes appear to vary dramatically +in amplitude despite a regular sinus rhythm. + +- Synthetic P/QRS/T components now have widths specified in milliseconds, + not fixed fractions of the cardiac cycle. P/T positioning and widths adapt + to the R–R interval, while the QRS width remains essentially constant. +- Sampling increased to **250 Hz** (4 ms intervals) to capture QRS peaks + more consistently, including at **189–240 bpm**. +- The ECG morphology remains independent of the respiratory arterial PPV + setting. The arterial and pleth delays and mechanical capture options are + unchanged. +- Regression tests compare peak heights at 60, 75, 120, 189 and 240 bpm, + and verify that changing PPV does not affect the ECG signal. + +The ECG remains a schematic educational signal; no voltage calibration, +lead placement model, diagnostic criteria, or patient-specific physiology +are simulated. + ## Signal implementation -- 100 Hz synthetic signal samples, 10 s retained history, 8 s scrolling trace. +- 250 Hz synthetic signal samples, 10 s retained history, 8 s scrolling trace. - Cairo draws into the GTK4 `DrawingArea` and scales with the window. - A conducted QRS records its own respiratory PPV multiplier at event time. The arterial pulse thus retains the same amplitude throughout the beat. @@ -139,3 +199,17 @@ src/ **Verification:** The archive is generated from these sources. Run `cargo test` locally to verify the Rust/GTK build; Rust and GTK4 development components were not available in the environment where this ZIP was prepared. + +## Changes in v0.3.2 + +1. Added live patient-name header in Admin/Monitor with blank-name fallback. +2. Added four levels of SpO₂ signal quality, quality stars and an irregular, + low-amplitude pleth waveform for Poor quality. +3. Added **Sensor not attached** with `NO SENSOR` status and suppression of + saturation, pulse rate and pleth waveform. +4. Added tests for signal-quality scaling, displayed readings and disconnected + sensor behavior. + +**Build verification:** ZIP integrity and patch application were checked. +The GTK4 application and Rust tests were not compiled in the packaging +environment; run `cargo test` and `cargo run --release` on Fedora. diff --git a/patient-monitor-simulation/src/model.rs b/patient-monitor-simulation/src/model.rs index 70eee9f..49f373f 100644 --- a/patient-monitor-simulation/src/model.rs +++ b/patient-monitor-simulation/src/model.rs @@ -58,12 +58,45 @@ pub enum CapnoShape { Obstructive, } -#[derive(Clone, Copy, Debug)] +/// Instructor-selected plethysmography signal quality; separate from the +/// physiological oxygen-saturation setting and mechanical pulse capture. +#[derive(Clone, Copy, Debug, PartialEq, Eq)] +pub enum Spo2Quality { + None, + Poor, + Adequate, + Good, +} + +impl Spo2Quality { + pub fn stars(self) -> &'static str { + match self { + Self::None => "", + Self::Poor => "★", + Self::Adequate => "★★", + Self::Good => "★★★", + } + } + + pub fn amplitude_scale(self) -> f64 { + match self { + Self::None => 0.0, + Self::Poor => 0.25, + Self::Adequate => 0.56, + Self::Good => 1.0, + } + } +} + +#[derive(Clone, Debug)] pub struct Parameters { + pub patient_name: String, // displayed in the monitor header, blank = generic title pub ecg_rhythm: EcgRhythm, pub heart_rate: i32, // bpm, organized electrical rate; not mechanical pulse rate pub pulse_conduction: PulseConduction, - pub spo2: i32, // % + pub spo2: i32, // %; instructor-set nominal saturation + pub spo2_quality: Spo2Quality, + pub spo2_sensor_attached: bool, pub art_systolic: i32, // mmHg, nominal pressure; display axis 0..200 pub art_diastolic: i32, // mmHg pub arterial_shape: ArterialShape, @@ -84,10 +117,13 @@ pub struct Parameters { impl Default for Parameters { fn default() -> Self { Self { + patient_name: String::new(), ecg_rhythm: EcgRhythm::Sinus, heart_rate: 75, pulse_conduction: PulseConduction::OneToOne, spo2: 98, + spo2_quality: Spo2Quality::Good, + spo2_sensor_attached: true, art_systolic: 120, art_diastolic: 75, arterial_shape: ArterialShape::Normal, @@ -119,6 +155,17 @@ mod tests { assert_eq!(mean_arterial_pressure(120, 75), 90); } + #[test] + fn spo2_quality_stars_and_amplitude_progress_monotonically() { + assert_eq!(Spo2Quality::None.stars(), ""); + assert_eq!(Spo2Quality::Poor.stars(), "★"); + assert_eq!(Spo2Quality::Adequate.stars(), "★★"); + assert_eq!(Spo2Quality::Good.stars(), "★★★"); + assert_eq!(Spo2Quality::None.amplitude_scale(), 0.0); + assert!(Spo2Quality::Poor.amplitude_scale() < Spo2Quality::Adequate.amplitude_scale()); + assert!(Spo2Quality::Adequate.amplitude_scale() < Spo2Quality::Good.amplitude_scale()); + } + #[test] fn grouped_mechanical_capture_follows_requested_patterns() { assert_eq!((1..=8).filter(|&b| PulseConduction::TwoToOne.conducts(b)).collect::>(), diff --git a/patient-monitor-simulation/src/render.rs b/patient-monitor-simulation/src/render.rs index 30325b8..70e340e 100644 --- a/patient-monitor-simulation/src/render.rs +++ b/patient-monitor-simulation/src/render.rs @@ -1,7 +1,7 @@ //! Size-independent Cairo drawing of the synthetic bedside monitor. use gtk::cairo::{Context, FontSlant, FontWeight, LineCap, LineJoin}; -use crate::model::{mean_arterial_pressure, EcgRhythm, Parameters, PulseConduction}; +use crate::model::{mean_arterial_pressure, EcgRhythm, Parameters, PulseConduction, Spo2Quality}; use crate::simulation::{Sample, Simulator}; type Color = (f64, f64, f64); @@ -43,8 +43,18 @@ pub fn draw(cr: &Context, width: i32, height: i32, p: &Parameters, sim: &Simulat let trace_right = (split_x - pad).max(trace_left + 40.0); let text_scale = (w.min(h * 1.7) / 850.0).clamp(0.65, 1.5); - text(cr, "PATIENT MONITOR", pad + 5.0, header * 0.58, 18.0 * text_scale, - LIGHT_GREY, true); + let patient_title = if p.patient_name.trim().is_empty() { + "PATIENT MONITOR" + } else { + p.patient_name.trim() + }; + let title_max_width = if w >= 850.0 { + split_x - pad * 2.0 - 145.0 * text_scale + } else { + split_x - pad * 2.0 + }; + fitted_text(cr, patient_title, pad + 5.0, header * 0.58, + 18.0 * text_scale, title_max_width.max(25.0), LIGHT_GREY); if w >= 850.0 { text(cr, "SIMULATION", split_x - 128.0 * text_scale, header * 0.58, 11.0 * text_scale, MUTED, false); @@ -84,6 +94,24 @@ pub fn draw(cr: &Context, width: i32, height: i32, p: &Parameters, sim: &Simulat } } +fn pleth_trace_enabled(p: &Parameters) -> bool { + p.spo2_sensor_attached && p.spo2_quality != Spo2Quality::None +} + +fn spo2_vitals(p: &Parameters, pulse_rate: Option) -> (String, String, String) { + if !p.spo2_sensor_attached { + return ("SpO₂".to_owned(), "NO SENSOR".to_owned(), "SpO₂ -- PR -- bpm".to_owned()); + } + if p.spo2_quality == Spo2Quality::None { + return ("SpO₂".to_owned(), "--".to_owned(), "NO SIGNAL PR -- bpm".to_owned()); + } + ( + format!("SpO₂ {}", p.spo2_quality.stars()), + if pulse_rate.is_some() { p.spo2.to_string() } else { "--".to_owned() }, + format!("% PR {} bpm", pulse_rate.map_or("--".to_owned(), |pr| pr.to_string())), + ) +} + fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64, top: f64, row_h: f64, width: f64, p: &Parameters, sim: &Simulator) { let label_size = (row_h * 0.135).clamp(11.0, 19.0); @@ -95,7 +123,7 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64, let pulse_rate = if has_capture { sim.pulse_rate() } else { None }; let (label, value, info) = match ch { Channel::Ecg => ( - "HR", + "HR".to_owned(), if !p.ecg_rhythm.has_qrs() || p.heart_rate <= 0 { "--".to_owned() } else { p.heart_rate.to_string() }, format!("bpm · {}", match p.ecg_rhythm { @@ -106,13 +134,9 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64, EcgRhythm::Asystole => "Asystole", }), ), - Channel::Pleth => ( - "SpO₂", - if pulse_rate.is_some() { p.spo2.to_string() } else { "--".to_owned() }, - format!("% PR {} bpm", pulse_rate.map_or("--".to_owned(), |pr| pr.to_string())), - ), + Channel::Pleth => spo2_vitals(p, pulse_rate), Channel::Art => ( - "ART", + "ART".to_owned(), if pulse_rate.is_some() { format!("{}/{}", p.art_systolic, p.art_diastolic) } else { "--/--".to_owned() }, @@ -126,13 +150,20 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64, } } else { "MAP -- mmHg".to_owned() }, ), - Channel::Capno => ("EtCO₂", p.etco2.to_string(), + Channel::Capno => ("EtCO₂".to_owned(), p.etco2.to_string(), format!("mmHg RR {} /min", p.respiratory_rate)), }; - text(cr, label, x, top + row_h * 0.24, label_size, color, false); - // Reduce wide BP values so they fit within the sidebar. - let value_size = if matches!(ch, Channel::Art) { number_size * 0.78 } else { number_size }; - text(cr, &value, x, top + row_h * 0.64, value_size, color, true); + text(cr, &label, x, top + row_h * 0.24, label_size, color, false); + // Reduce wide readings so they fit within the sidebar. + let value_size = if value == "NO SENSOR" { + number_size.min(0.19 * width).min(26.0) + } else if matches!(ch, Channel::Art) { + number_size * 0.78 + } else { + number_size + }; + fitted_text(cr, &value, x, top + row_h * 0.64, value_size, + width.max(20.0), color); text(cr, &info, x, top + row_h * 0.87, sub_size * 0.85, color, false); } @@ -175,6 +206,13 @@ fn draw_trace(cr: &Context, channel: Channel, color: Color, right, top + trace_height * 0.5, GRID, 0.7); } + // Disconnected or absent pleth signal: no curve, including historical pulses. + if matches!(channel, Channel::Pleth) && !pleth_trace_enabled(p) + { + let _ = cr.restore(); + return; + } + set_color(cr, color); cr.set_line_width((trace_height * 0.016).clamp(1.2, 2.4)); cr.set_line_cap(LineCap::Round); @@ -194,13 +232,68 @@ fn draw_trace(cr: &Context, channel: Channel, color: Color, fn normalized(channel: Channel, s: &Sample, p: &Parameters) -> f64 { match channel { Channel::Ecg => (0.40 + s.ecg * 0.38).clamp(0.02, 0.98), - Channel::Pleth => (0.10 + s.pleth * 0.78).clamp(0.02, 0.98), + Channel::Pleth => (0.10 + pleth_visual_amplitude(s.pleth, s.time, p.spo2_quality) * 0.78) + .clamp(0.02, 0.98), Channel::Art => (s.art / 200.0).clamp(0.0, 1.0), Channel::Capno => (0.08 + (s.co2 / f64::from(p.etco2.max(1))) * 0.80) .clamp(0.02, 0.98), } } +/// Signal degradation is presentation-only: no quality setting can invent +/// pulses or change the ECG/ART generator. The noise is smoothly interpolated +/// and reproducible, so redrawing a sample does not make it flicker. +fn pleth_visual_amplitude(pleth: f64, time: f64, quality: Spo2Quality) -> f64 { + let scale = quality.amplitude_scale(); + if scale == 0.0 || pleth <= 0.0 { return 0.0; } + let distortion = if quality == Spo2Quality::Poor { + (1.0 + 0.55 * smooth_noise(time * 7.0) + + 0.20 * smooth_noise(time * 23.0 + 4.0)).clamp(0.15, 1.75) + } else { + 1.0 + }; + (pleth * scale * distortion).clamp(0.0, 1.0) +} + +fn smooth_noise(position: f64) -> f64 { + let index = position.floor() as i64; + let fraction = position - index as f64; + let smooth = fraction * fraction * (3.0 - 2.0 * fraction); + let a = noise_value(index); + let b = noise_value(index.wrapping_add(1)); + a + (b - a) * smooth +} + +fn noise_value(index: i64) -> f64 { + let mut x = (index as u64).wrapping_mul(0x9E37_79B9_7F4A_7C15); + x ^= x >> 30; + x = x.wrapping_mul(0xBF58_476D_1CE4_E5B9); + x ^= x >> 27; + x = x.wrapping_mul(0x94D0_49BB_1331_11EB); + x ^= x >> 31; + (x as f64 / u64::MAX as f64) * 2.0 - 1.0 +} + +/// Fit a name or numeric/status reading horizontally without changing the +/// other monitor dimensions. For exceptionally long values, clip safely. +fn fitted_text(cr: &Context, value: &str, x: f64, baseline: f64, + nominal_size: f64, available_width: f64, color: Color) { + cr.select_font_face("Sans", FontSlant::Normal, FontWeight::Bold); + cr.set_font_size(nominal_size); + let actual_width = cr.text_extents(value).map(|ext| ext.x_advance()).unwrap_or(0.0); + let fitted_size = if actual_width > available_width && actual_width > 0.0 { + (nominal_size * available_width / actual_width).max(8.0) + } else { + nominal_size + }; + let _ = cr.save(); + cr.rectangle(x, baseline - fitted_size * 1.25, + available_width.max(1.0), fitted_size * 1.55); + cr.clip(); + text(cr, value, x, baseline, fitted_size, color, true); + let _ = cr.restore(); +} + fn set_color(cr: &Context, c: Color) { cr.set_source_rgb(c.0, c.1, c.2); } @@ -242,6 +335,53 @@ mod tests { assert!(visible_channels(&p).is_empty()); } + #[test] + fn pleth_degradation_preserves_capture_timing_and_suppresses_false_pulses() { + let pulse = 0.6; + let t = 1.234; + assert_eq!(pleth_visual_amplitude(pulse, t, Spo2Quality::None), 0.0); + assert_eq!(pleth_visual_amplitude(0.0, t, Spo2Quality::Poor), 0.0); + assert!(pleth_visual_amplitude(pulse, t, Spo2Quality::Poor) + < pleth_visual_amplitude(pulse, t, Spo2Quality::Adequate)); + assert!(pleth_visual_amplitude(pulse, t, Spo2Quality::Adequate) + < pleth_visual_amplitude(pulse, t, Spo2Quality::Good)); + assert_eq!(pleth_visual_amplitude(pulse, t, Spo2Quality::Good), pulse); + assert_eq!(pleth_visual_amplitude(pulse, t, Spo2Quality::Poor), + pleth_visual_amplitude(pulse, t, Spo2Quality::Poor)); + assert_ne!(pleth_visual_amplitude(pulse, t, Spo2Quality::Poor), + pleth_visual_amplitude(pulse, t + 0.5, Spo2Quality::Poor)); + } + + #[test] + fn disconnected_or_no_quality_means_no_pleth_or_spo2_reading() { + let mut p = Parameters::default(); + assert!(pleth_trace_enabled(&p)); + p.spo2_sensor_attached = false; + assert!(!pleth_trace_enabled(&p)); + assert_eq!(spo2_vitals(&p, Some(75)).1, "NO SENSOR"); + assert!(spo2_vitals(&p, Some(75)).2.contains("PR --")); + p.spo2_sensor_attached = true; + p.spo2_quality = Spo2Quality::None; + assert!(!pleth_trace_enabled(&p)); + assert_eq!(spo2_vitals(&p, Some(75)).1, "--"); + assert!(spo2_vitals(&p, Some(75)).2.contains("NO SIGNAL")); + assert!(spo2_vitals(&p, Some(75)).2.contains("PR --")); + assert!(p.show_spo2); // no readings, but visible row and status + } + + #[test] + fn poor_and_good_quality_keep_derived_pr_and_quality_indicators() { + let mut p = Parameters::default(); + p.spo2_quality = Spo2Quality::Poor; + assert_eq!(spo2_vitals(&p, Some(75)).0, "SpO₂ ★"); + assert_eq!(spo2_vitals(&p, Some(75)).1, "98"); + assert!(spo2_vitals(&p, Some(75)).2.contains("PR 75 bpm")); + p.spo2_quality = Spo2Quality::Good; + assert_eq!(spo2_vitals(&p, Some(75)).0, "SpO₂ ★★★"); + assert_eq!(spo2_vitals(&p, None).1, "--"); + assert!(spo2_vitals(&p, None).2.contains("PR --")); + } + #[test] fn arterial_axis_is_absolute_and_fixed_to_200_mmhg() { let p = Parameters::default(); diff --git a/patient-monitor-simulation/src/simulation.rs b/patient-monitor-simulation/src/simulation.rs index 78b268b..f3d7b01 100644 --- a/patient-monitor-simulation/src/simulation.rs +++ b/patient-monitor-simulation/src/simulation.rs @@ -4,7 +4,7 @@ use std::collections::VecDeque; use crate::model::{ArterialShape, CapnoShape, EcgRhythm, Parameters, PulseConduction}; -const SAMPLE_STEP: f64 = 0.01; // 100 Hz +const SAMPLE_STEP: f64 = 0.004; // 250 Hz; adequately samples the QRS upstroke const HISTORY_SECONDS: f64 = 10.0; const ART_DELAY: f64 = 0.12; // QRS -> arterial upstroke, seconds (schematic) const PLETH_DELAY: f64 = 0.30; // QRS -> peripheral pleth onset, seconds @@ -54,7 +54,7 @@ pub struct Simulator { impl Simulator { pub fn new(params: &Parameters) -> Self { let mut sim = Self { - samples: VecDeque::with_capacity(1_100), + samples: VecDeque::with_capacity((HISTORY_SECONDS / SAMPLE_STEP) as usize + 16), time: -8.0, ecg_phase: 0.0, respiratory_phase: 0.0, @@ -68,7 +68,7 @@ impl Simulator { pending_time: 0.0, }; // Prepopulate the trace and pulse history, including the initial pulse rate. - for _ in 0..800 { + for _ in 0..(8.0 / SAMPLE_STEP) as usize { sim.step(params); } sim @@ -143,7 +143,7 @@ impl Simulator { let increment = SAMPLE_STEP * params.heart_rate as f64 / 60.0 / irregularity; let next_phase = self.ecg_phase + increment; if self.ecg_phase < QRS_PHASE && next_phase >= QRS_PHASE { - // Interpolate within the 10ms sample so mechanical onsets stay aligned. + // Interpolate within the 4 ms sample so mechanical onsets stay aligned. let qrs_time = self.time - SAMPLE_STEP * (next_phase - QRS_PHASE) / increment; self.ecg_beat_number += 1; if params.pulse_conduction.conducts(self.ecg_beat_number) { @@ -230,6 +230,17 @@ fn phase_gaussian(phase: f64, center: f64, width: f64) -> f64 { gaussian(distance, 0.0, width) } +/// Periodic ECG component with a location and width expressed in seconds, +/// not as fractions of the R-R interval. This keeps QRS morphology from +/// artificially narrowing when the instructor increases the heart rate. +fn ecg_lobe(phase: f64, rr_seconds: f64, offset_seconds: f64, width_seconds: f64) -> f64 { + phase_gaussian( + phase, + QRS_PHASE + offset_seconds / rr_seconds, + width_seconds / rr_seconds, + ) +} + fn ecg_amplitude(phase: f64, time: f64, rhythm: EcgRhythm, heart_rate: i32) -> f64 { if rhythm == EcgRhythm::VentricularFibrillation { // Non-periodic-looking composite oscillation with no organized QRS. @@ -240,26 +251,41 @@ fn ecg_amplitude(phase: f64, time: f64, rhythm: EcgRhythm, heart_rate: i32) -> f if heart_rate <= 0 || rhythm == EcgRhythm::Asystole { return 0.006 * (time * 9.3).sin(); } + + // ECG wave durations are measured in *seconds*. Only the P/T placement + // and their widths shorten with R-R interval; Q/R/S widths stay fixed. + // These synthetic lead-II-like morphologies are illustrative, not + // calibrated or validated diagnostic ECGs. + let rr_seconds = 60.0 / f64::from(heart_rate); + let p_before_qrs = (rr_seconds * 0.26).clamp(0.08, 0.18); + let t_after_qrs = (rr_seconds * 0.30).clamp(0.10, 0.29); + let p_width = (rr_seconds * 0.045).clamp(0.014, 0.035); + let t_width = (rr_seconds * 0.09).clamp(0.022, 0.065); + let lobe = |offset, width| ecg_lobe(phase, rr_seconds, offset, width); + match rhythm { EcgRhythm::Sinus => { - 0.16 * phase_gaussian(phase, 0.16, 0.030) - - 0.19 * phase_gaussian(phase, 0.300, 0.011) - + 1.26 * phase_gaussian(phase, QRS_PHASE, 0.008) - - 0.32 * phase_gaussian(phase, 0.363, 0.014) - + 0.32 * phase_gaussian(phase, 0.61, 0.070) + // Small P wave, narrow negative Q, prominent R, negative S and T. + 0.16 * lobe(-p_before_qrs, p_width) + - 0.22 * lobe(-0.026, 0.009) + + 1.26 * lobe(0.0, 0.012) + - 0.32 * lobe(0.028, 0.012) + + 0.32 * lobe(t_after_qrs, t_width) } EcgRhythm::AtrialFibrillation => { + // No organized P waves; preserve the QRS shape under changing HR. 0.023 * (time * 39.0).sin() + 0.014 * (time * 57.0).sin() - - 0.19 * phase_gaussian(phase, 0.300, 0.011) - + 1.26 * phase_gaussian(phase, QRS_PHASE, 0.008) - - 0.32 * phase_gaussian(phase, 0.363, 0.014) - + 0.28 * phase_gaussian(phase, 0.61, 0.072) + - 0.22 * lobe(-0.026, 0.009) + + 1.26 * lobe(0.0, 0.012) + - 0.32 * lobe(0.028, 0.012) + + 0.28 * lobe(t_after_qrs, t_width) } EcgRhythm::VentricularTachycardia => { - 1.06 * phase_gaussian(phase, 0.31, 0.086) - - 0.49 * phase_gaussian(phase, 0.46, 0.067) - - 0.16 * phase_gaussian(phase, 0.72, 0.10) + // Broad monomorphic ventricular complexes, also in milliseconds. + 1.06 * lobe(0.0, 0.045) + - 0.49 * lobe(0.068, 0.030) + - 0.16 * lobe(0.13, 0.045) } EcgRhythm::VentricularFibrillation | EcgRhythm::Asystole => unreachable!(), } @@ -472,6 +498,56 @@ mod tests { assert!(sim.samples().iter().any(|s| s.art > 0.0)); } + #[test] + fn sinus_qrs_peak_height_is_stable_even_at_high_heart_rates() { + // The previous phase-based 100 Hz version varied strongly at 189 bpm: + // the narrow R peaks frequently fell between sample timestamps. + for heart_rate in [60, 75, 120, 189, 240] { + let p = Parameters { heart_rate, ..Parameters::default() }; + let mut sim = blank(&p); + let rr = 60.0 / f64::from(heart_rate); + let duration = 9.0; + while sim.time < duration { + sim.step(&p); + } + + // Compare maxima in +/-30 ms windows around the exact QRS times. + let peaks: Vec = (1..18) + .filter_map(|beat| { + let qrs_time = (f64::from(beat) + QRS_PHASE) * rr; + if qrs_time > duration - 0.05 { return None; } + sim.samples.iter() + .filter(|s| (s.time - qrs_time).abs() <= 0.03) + .map(|s| s.ecg) + .reduce(f64::max) + }) + .collect(); + assert!(peaks.len() >= 5, "too few captured QRS at {heart_rate} bpm"); + let minimum = peaks.iter().copied().fold(f64::INFINITY, f64::min); + let maximum = peaks.iter().copied().fold(f64::NEG_INFINITY, f64::max); + assert!(minimum > 1.1, "QRS peak too small at {heart_rate} bpm: {minimum}"); + assert!(maximum - minimum < 0.04, + "QRS peak varies excessively at {heart_rate} bpm: {minimum}..{maximum}"); + } + } + + #[test] + fn pulse_pressure_variation_does_not_change_ecg_amplitude() { + let baseline = Parameters::default(); + let with_ppv = Parameters { + pulse_pressure_variation: 60, + ..Parameters::default() + }; + let mut sim_baseline = blank(&baseline); + let mut sim_ppv = blank(&with_ppv); + for _ in 0..1_000 { + sim_baseline.step(&baseline); + sim_ppv.step(&with_ppv); + assert_eq!(sim_baseline.samples.back().unwrap().ecg, + sim_ppv.samples.back().unwrap().ecg); + } + } + #[test] fn capnogram_reaches_etco2_plateau() { assert!((capno_amplitude(0.76, CapnoShape::Normal) - 1.0).abs() < 1e-8); diff --git a/patient-monitor-simulation/src/ui.rs b/patient-monitor-simulation/src/ui.rs index 48b3f3c..a68fcc3 100644 --- a/patient-monitor-simulation/src/ui.rs +++ b/patient-monitor-simulation/src/ui.rs @@ -8,7 +8,7 @@ use gtk::glib; use gtk::prelude::*; use gtk::{Application, ApplicationWindow, Orientation}; -use crate::model::{ArterialShape, CapnoShape, EcgRhythm, Parameters, PulseConduction}; +use crate::model::{ArterialShape, CapnoShape, EcgRhythm, Parameters, PulseConduction, Spo2Quality}; use crate::render; use crate::simulation::Simulator; @@ -41,12 +41,12 @@ fn create_monitor(app: &Application, params: SharedParams, let params = params.clone(); let simulator = simulator.clone(); move |_area, cr, width, height| { - let config = *params.borrow(); + let config = params.borrow(); render::draw(cr, width, height, &config, &simulator.borrow()); } }); - // Synchronize simulation time with frame updates; synthesize at 100 Hz. + // Synchronize simulation time with frame updates; synthesize at 250 Hz. let previous = Rc::new(Cell::new(Instant::now())); canvas.add_tick_callback({ let params = params.clone(); @@ -54,7 +54,7 @@ fn create_monitor(app: &Application, params: SharedParams, let now = Instant::now(); let elapsed = now.saturating_duration_since(previous.get()).as_secs_f64(); previous.set(now); - let config = *params.borrow(); + let config = params.borrow(); simulator.borrow_mut().advance(elapsed, &config); area.queue_draw(); glib::ControlFlow::Continue @@ -105,6 +105,24 @@ fn create_admin(app: &Application, params: SharedParams, scroller.set_policy(gtk::PolicyType::Never, gtk::PolicyType::Automatic); let controls = gtk::Box::new(Orientation::Vertical, 12); + let patient = group(&controls, "Patient"); + let patient_row = gtk::Box::new(Orientation::Horizontal, 8); + let patient_label = gtk::Label::new(Some("Patient name")); + patient_label.set_xalign(0.0); + patient_label.set_width_chars(17); + let name_entry = gtk::Entry::new(); + name_entry.set_hexpand(true); + name_entry.set_max_length(80); + name_entry.set_placeholder_text(Some("Name displayed on monitor")); + name_entry.set_text(¶ms.borrow().patient_name); + name_entry.connect_changed({ + let params = params.clone(); + move |entry| params.borrow_mut().patient_name = entry.text().to_string() + }); + patient_row.append(&patient_label); + patient_row.append(&name_entry); + patient.append(&patient_row); + let ecg = group(&controls, "ECG"); add_visibility(&ecg, params.borrow().show_ecg, params.clone(), |p, show| p.show_ecg = show); add_dropdown(&ecg, "ECG rhythm", &[ @@ -126,6 +144,26 @@ fn create_admin(app: &Application, params: SharedParams, add_visibility(&spo2, params.borrow().show_spo2, params.clone(), |p, show| p.show_spo2 = show); add_numeric(&spo2, "SpO₂", "%", 0, 100, params.borrow().spo2, params.clone(), |p, v| p.spo2 = v); + let sensor = gtk::CheckButton::with_label("Sensor not attached"); + sensor.set_active(!params.borrow().spo2_sensor_attached); + sensor.connect_toggled({ + let params = params.clone(); + move |button| params.borrow_mut().spo2_sensor_attached = !button.is_active() + }); + spo2.append(&sensor); + add_dropdown_at(&spo2, "Signal quality", &[ + "0 — None (no reading)", + "1 — Poor (*)", + "2 — Adequate (**)", + "3 — Good (***)", + ], params.borrow().spo2_quality as u32, params.clone(), |p, selected| { + p.spo2_quality = match selected { + 1 => Spo2Quality::Poor, + 2 => Spo2Quality::Adequate, + 3 => Spo2Quality::Good, + _ => Spo2Quality::None, + }; + }); add_dropdown(&spo2, "Mechanical capture", &[ "1:1 (every QRS)", "2:1 (one pulse in two)", @@ -242,12 +280,19 @@ where F: Fn(&mut Parameters, bool) + 'static { fn add_dropdown(parent: >k::Box, label: &str, items: &[&str], params: SharedParams, setter: F) +where F: Fn(&mut Parameters, u32) + 'static { + add_dropdown_at(parent, label, items, 0, params, setter); +} + +fn add_dropdown_at(parent: >k::Box, label: &str, items: &[&str], + initial: u32, params: SharedParams, setter: F) where F: Fn(&mut Parameters, u32) + 'static { let row = gtk::Box::new(Orientation::Horizontal, 8); let caption = gtk::Label::new(Some(label)); caption.set_xalign(0.0); caption.set_width_chars(17); let combo = gtk::DropDown::from_strings(items); + combo.set_selected(initial); combo.set_hexpand(true); combo.connect_selected_notify(move |combo| { setter(&mut params.borrow_mut(), combo.selected());