From 5e397019fc561d270d28b3d26eca85e33cb0ee83 Mon Sep 17 00:00:00 2001 From: GABRIEL Sebastian Date: Thu, 12 Nov 2026 12:08:46 +0100 Subject: [PATCH] v0.4.2: add PVT --- ...-monitor-simulation-v0.4.1-to-v0.4.2.patch | 509 ++++++++++++++++++ patient-monitor-simulation/Cargo.lock | 2 +- patient-monitor-simulation/Cargo.toml | 2 +- patient-monitor-simulation/README.md | 27 +- patient-monitor-simulation/src/model.rs | 80 ++- patient-monitor-simulation/src/render.rs | 70 +-- patient-monitor-simulation/src/simulation.rs | 77 ++- patient-monitor-simulation/src/ui.rs | 11 +- 8 files changed, 727 insertions(+), 51 deletions(-) create mode 100644 patient-monitor-simulation-v0.4.1-to-v0.4.2.patch diff --git a/patient-monitor-simulation-v0.4.1-to-v0.4.2.patch b/patient-monitor-simulation-v0.4.1-to-v0.4.2.patch new file mode 100644 index 0000000..e70a2e3 --- /dev/null +++ b/patient-monitor-simulation-v0.4.1-to-v0.4.2.patch @@ -0,0 +1,509 @@ +diff --git a/Cargo.toml b/Cargo.toml +index 4c97d45..02a5d17 100644 +--- a/Cargo.toml ++++ b/Cargo.toml +@@ -1,6 +1,6 @@ + [package] + name = "patient-monitor-simulation" +-version = "0.4.1" ++version = "0.4.2" + edition = "2021" + license = "MIT" + description = "Synthetic patient-monitor simulation for teaching (not for clinical use)" +diff --git a/README.md b/README.md +index 4c5b8f0..c693e16 100644 +--- a/README.md ++++ b/README.md +@@ -1,4 +1,4 @@ +-# Patient Monitor Simulation (PaMSim) — v0.4.1 ++# Patient Monitor Simulation (PaMSim) — v0.4.2 + + A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux. + +@@ -130,7 +130,7 @@ Admin → **Pulse oximetry** has two additional controls: + + | Setting | Pleth waveform | Monitor display | + | --- | --- | --- | +-| **0 — None** | No waveform | SpO₂ `--`, PR `--`, **NO SIGNAL**; no stars | ++| **0 — None** | No waveform | Flashing **NO READING**, PR `--`; no stars | + | **1 — Poor** | Small, irregularly amplitude-distorted pulse | 1 star (★) | + | **2 — Adequate** | Medium, smoothly damped pulse | 2 stars (★★) | + | **3 — Good** | Full nominal, smoothly damped pulse | 3 stars (★★★) | +@@ -143,7 +143,7 @@ remains derived from mechanically captured QRS complexes. + + The degraded waveform uses deterministic, smoothly interpolated pseudo-noise + that scales only existing pleth pulses: it cannot manufacture pulses during +-PEA, ventricular fibrillation or asystole. Unplugging a sensor or selecting ++PEA, PVT, ventricular fibrillation or asystole. Unplugging a sensor or selecting + quality 0 hides even previously buffered pleth samples immediately. ECG and + ART continue unaffected. The **Show on monitor** checkbox still hides the + entire SpO₂ row; sensor/quality controls leave the row visible so the status +@@ -151,15 +151,18 @@ can be taught. + + ## ECG and mechanical coupling + +-- ECG rhythms: sinus, atrial fibrillation, monomorphic ventricular tachycardia, ++- ECG rhythms: sinus, atrial fibrillation, monomorphic ventricular tachycardia ++ (potentially perfusing), pulseless ventricular tachycardia (PVT), + ventricular fibrillation and asystole. + - Mechanical capture: **1:1**, **2:1**, **3:1**, **None (PEA)**, or deterministic + pseudo-random capture (~65%). PR is derived from conducted QRS events, never + controlled by a pulse-rate slider. + - A captured QRS leads to an ART upstroke after a schematic **120 ms**, and a + peripheral pleth pulse after **300 ms**. Pleth is strongly damped/filtered. +-- VF, asystole and PEA suppress mechanical pulses; old samples scroll out of +- view. NIBP is a static, separately entered cuff reading. ++- PVT, VF, asystole and PEA suppress mechanical pulses; the ART trace then ++ drifts smoothly at 0–5 mmHg rather than representing a pulsatile pressure. ++ Previous pressure samples scroll out of view. NIBP is a static, ++ separately entered cuff reading. + + ## Invasive arterial pressure and PPV (new in v0.3) + +@@ -205,7 +208,7 @@ The five **Show on monitor** checkboxes affect the presentation only: + + | Checkbox | Hidden monitor content | + | --- | --- | +-| ECG | ECG waveform, HR and rhythm label | ++| ECG | ECG waveform, HR and rhythm alarm (when present) | + | Pulse oximetry | Pleth waveform, SpO₂ and PR | + | Invasive arterial blood pressure | ART waveform, pressure values, MAP and PPV label | + | Capnography | CO₂ waveform, EtCO₂ and RR | +@@ -287,3 +290,13 @@ were not available in the environment where this ZIP was prepared. + **Build verification:** ZIP integrity and patch application were checked. + The GTK4 application and Rust tests were not compiled in the packaging + environment; run `cargo test` and `cargo run --release` on Fedora. ++ ++ ++## v0.4.2 — Rhythm, sensor and missing-reading alarms ++ ++- **VT** remains potentially perfusing. The new **PVT** (pulseless ventricular tachycardia) rhythm retains organized broad QRS complexes but produces no arterial/pleth pulses. VF and asystole are also pulseless regardless of capture selection. ++- **ECG**: a flashing **ARRHYTHMIA** message for VT, PVT and VF; a flashing **ASYSTOLE** message for asystole. These event alarms do not depend on numerical HR limits. ++- **SpO₂**: when the probe is disconnected, a flashing **NO SENSOR** replaces the saturation reading. Quality 0, loss of mechanical capture or a pulseless rhythm results in flashing **NO READING** (no numerical SpO₂/PR). Sensor disconnection takes precedence. No pleth waveform is displayed in these conditions. ++- **ART**: without mechanical pulses (including PVT/VF/asystole/PEA), the simulated invasive pressure line has slow non-pulsatile drift between **0 and 5 mmHg**. The numerical blood-pressure reading remains unavailable (`--/--`), rather than misrepresenting this baseline as true systolic and diastolic pressures. ++- **ECG rhythm name** has been removed from the monitor; only HR and the associated alarm message, when present, are visible. The instructor continues to select the rhythm in Admin. ++- Numerical alarm thresholds and the Adult preset from v0.4.1 are unchanged. Synthetic demonstration behavior only; not suitable for clinical decisions. +diff --git a/src/model.rs b/src/model.rs +index 2ce532c..6b1f6d1 100644 +--- a/src/model.rs ++++ b/src/model.rs +@@ -5,15 +5,40 @@ pub enum EcgRhythm { + Sinus, + AtrialFibrillation, + VentricularTachycardia, ++ PulselessVentricularTachycardia, + VentricularFibrillation, + Asystole, + } + + impl EcgRhythm { +- /// VF and asystole have no organized QRS to trigger a mechanical pulse. ++ /// Organized electrical QRS complexes. PVT still has electrical QRS complexes. + pub fn has_qrs(self) -> bool { + !matches!(self, Self::VentricularFibrillation | Self::Asystole) + } ++ ++ /// Whether a QRS can trigger a mechanical pulse, depending on capture. ++ /// Perfusing VT is distinct from PVT. VF and asystole have no QRS. ++ pub fn can_generate_pulse(self) -> bool { ++ self.has_qrs() && self != Self::PulselessVentricularTachycardia ++ } ++ ++ /// Rhythm alarms are independent of instructor-defined HR thresholds. ++ pub fn rhythm_alarm(self) -> Option<&'static str> { ++ match self { ++ Self::VentricularTachycardia | Self::PulselessVentricularTachycardia ++ | Self::VentricularFibrillation => Some("ARRHYTHMIA"), ++ Self::Asystole => Some("ASYSTOLE"), ++ _ => None, ++ } ++ } ++} ++ ++/// Pulse-oximeter availability and technical alarms. Sensor loss takes precedence. ++#[derive(Clone, Copy, Debug, PartialEq, Eq)] ++pub enum Spo2Status { ++ Available, ++ NoSensor, ++ NoReading, + } + + #[derive(Clone, Copy, Debug, PartialEq, Eq)] +@@ -195,6 +220,24 @@ pub struct Parameters { + pub show_nibp: bool, + } + ++impl Parameters { ++ /// No saturation without an attached sensor, usable signal quality and ++ /// two observed mechanical pulse events. Thresholds do not control this alarm. ++ pub fn spo2_status(&self, pulse_rate: Option) -> Spo2Status { ++ if !self.spo2_sensor_attached { ++ Spo2Status::NoSensor ++ } else if self.spo2_quality == Spo2Quality::None || pulse_rate.is_none() ++ || !self.ecg_rhythm.can_generate_pulse() ++ || self.pulse_conduction == PulseConduction::None ++ || self.heart_rate <= 0 ++ { ++ Spo2Status::NoReading ++ } else { ++ Spo2Status::Available ++ } ++ } ++} ++ + impl Default for Parameters { + fn default() -> Self { + Self { +@@ -308,6 +351,41 @@ mod tests { + assert!(!p.alarms.pr.enabled()); + } + ++ #[test] ++ fn vt_stays_perfusing_and_pvt_is_electrically_organized_but_pulseless() { ++ use EcgRhythm::*; ++ assert!(VentricularTachycardia.has_qrs()); ++ assert!(VentricularTachycardia.can_generate_pulse()); ++ assert!(PulselessVentricularTachycardia.has_qrs()); ++ assert!(!PulselessVentricularTachycardia.can_generate_pulse()); ++ assert!(!VentricularFibrillation.can_generate_pulse()); ++ assert!(!Asystole.can_generate_pulse()); ++ for rhythm in [VentricularTachycardia, PulselessVentricularTachycardia, VentricularFibrillation] { ++ assert_eq!(rhythm.rhythm_alarm(), Some("ARRHYTHMIA")); ++ } ++ assert_eq!(Asystole.rhythm_alarm(), Some("ASYSTOLE")); ++ assert_eq!(Sinus.rhythm_alarm(), None); ++ assert_eq!(AtrialFibrillation.rhythm_alarm(), None); ++ } ++ ++ #[test] ++ fn sensor_and_no_reading_alarms_override_spo2_thresholds() { ++ let mut p = Parameters::default(); ++ assert_eq!(p.spo2_status(Some(80)), Spo2Status::Available); ++ assert_eq!(p.spo2_status(None), Spo2Status::NoReading); ++ p.spo2_quality = Spo2Quality::None; ++ assert_eq!(p.spo2_status(Some(80)), Spo2Status::NoReading); ++ p.spo2_sensor_attached = false; ++ assert_eq!(p.spo2_status(Some(80)), Spo2Status::NoSensor); ++ p.spo2_sensor_attached = true; ++ p.spo2_quality = Spo2Quality::Good; ++ p.ecg_rhythm = EcgRhythm::PulselessVentricularTachycardia; ++ assert_eq!(p.spo2_status(Some(80)), Spo2Status::NoReading); ++ p.ecg_rhythm = EcgRhythm::Sinus; ++ p.pulse_conduction = PulseConduction::None; ++ assert_eq!(p.spo2_status(Some(80)), Spo2Status::NoReading); ++ } ++ + #[test] + fn grouped_mechanical_capture_follows_requested_patterns() { + assert_eq!((1..=8).filter(|&b| PulseConduction::TwoToOne.conducts(b)).collect::>(), +diff --git a/src/render.rs b/src/render.rs +index 8391fe8..c0f8474 100644 +--- a/src/render.rs ++++ b/src/render.rs +@@ -1,7 +1,7 @@ + //! Size-independent Cairo drawing of the synthetic bedside monitor. + use gtk::cairo::{Context, FontSlant, FontWeight, LineCap, LineJoin}; + +-use crate::model::{mean_arterial_pressure, AlarmLimits, AlarmState, EcgRhythm, Parameters, PulseConduction, Spo2Quality}; ++use crate::model::{mean_arterial_pressure, AlarmLimits, AlarmState, Parameters, PulseConduction, Spo2Quality, Spo2Status}; + use crate::simulation::{Sample, Simulator}; + + type Color = (f64, f64, f64); +@@ -106,17 +106,17 @@ fn pleth_trace_enabled(p: &Parameters) -> bool { + } + + fn spo2_vitals(p: &Parameters, pulse_rate: Option) -> (String, String, String) { +- if !p.spo2_sensor_attached { +- return ("SpO₂".to_owned(), "NO SENSOR".to_owned(), "SpO₂ -- PR -- bpm".to_owned()); ++ match p.spo2_status(pulse_rate) { ++ Spo2Status::NoSensor => ( ++ "SpO₂".to_owned(), "NO SENSOR".to_owned(), "PR -- bpm".to_owned()), ++ Spo2Status::NoReading => ( ++ "SpO₂".to_owned(), "NO READING".to_owned(), "PR -- bpm".to_owned()), ++ Spo2Status::Available => ( ++ format!("SpO₂ {}", p.spo2_quality.stars()), ++ p.spo2.to_string(), ++ format!("% PR {} bpm", pulse_rate.unwrap_or_default()), ++ ), + } +- if p.spo2_quality == Spo2Quality::None { +- return ("SpO₂".to_owned(), "--".to_owned(), "NO SIGNAL PR -- bpm".to_owned()); +- } +- ( +- format!("SpO₂ {}", p.spo2_quality.stars()), +- if pulse_rate.is_some() { p.spo2.to_string() } else { "--".to_owned() }, +- format!("% PR {} bpm", pulse_rate.map_or("--".to_owned(), |pr| pr.to_string())), +- ) + } + + fn alarmed(limits: AlarmLimits, value: Option) -> bool { +@@ -136,16 +136,15 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64, + let number_size = (row_h * 0.375).min(width * 0.26).clamp(16.0, 59.0); + let sub_size = (row_h * 0.16).clamp(11.0, 22.0) * 0.85; + let flash = alarm_flash_on(sim); +- let has_capture = p.ecg_rhythm.has_qrs() ++ let has_capture = p.ecg_rhythm.can_generate_pulse() + && p.heart_rate > 0 + && p.pulse_conduction != PulseConduction::None; + let pulse_rate = if has_capture { sim.pulse_rate() } else { None }; + let ecg_hr = if p.ecg_rhythm.has_qrs() && p.heart_rate > 0 { + Some(p.heart_rate) + } else { None }; +- let oxygen = if pleth_trace_enabled(p) && pulse_rate.is_some() { +- Some(p.spo2) +- } else { None }; ++ let spo2_status = p.spo2_status(pulse_rate); ++ let oxygen = if spo2_status == Spo2Status::Available { Some(p.spo2) } else { None }; + let art_map = mean_arterial_pressure(p.art_systolic, p.art_diastolic); + + let limits: Vec<(&str, AlarmLimits)> = match ch { +@@ -165,23 +164,23 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64, + draw_alarm_number(cr, &ecg_hr.map_or("--".to_owned(), |v| v.to_string()), + x, value_y, number_size, width, color, + alarmed(p.alarms.hr, ecg_hr), flash); +- let rhythm = match p.ecg_rhythm { +- EcgRhythm::Sinus => "Sinus", +- EcgRhythm::AtrialFibrillation => "AF", +- EcgRhythm::VentricularTachycardia => "VT", +- EcgRhythm::VentricularFibrillation => "VF", +- EcgRhythm::Asystole => "Asystole", +- }; +- text(cr, &format!("bpm · {}", rhythm), x, info_y, sub_size, color, false); ++ // Show only the clinical alarm message, never the selected ECG rhythm. ++ if let Some(message) = p.ecg_rhythm.rhythm_alarm() { ++ draw_alarm_number(cr, message, x, info_y, sub_size * 1.1, ++ width, color, true, flash); ++ } else { ++ text(cr, "bpm", x, info_y, sub_size, color, false); ++ } + } + Channel::Pleth => { + let (label, value, info) = spo2_vitals(p, pulse_rate); + text(cr, &label, x, top + row_h * 0.24, label_size, color, false); +- let value_size = if value == "NO SENSOR" { +- number_size.min(0.19 * width).min(26.0) ++ let technical_alarm = spo2_status != Spo2Status::Available; ++ let value_size = if technical_alarm { ++ number_size.min(0.17 * width).min(26.0) + } else { number_size }; + draw_alarm_number(cr, &value, x, value_y, value_size, +- width, color, alarmed(p.alarms.spo2, oxygen), flash); ++ width, color, technical_alarm || alarmed(p.alarms.spo2, oxygen), flash); + if oxygen.is_some() { + draw_alarm_inline(cr, x, info_y, sub_size, width, color, + "% PR ", &pulse_rate.unwrap_or_default().to_string(), " bpm", +@@ -377,7 +376,9 @@ fn draw_trace(cr: &Context, channel: Channel, color: Color, + } + + // Disconnected or absent pleth signal: no curve, including historical pulses. +- if matches!(channel, Channel::Pleth) && !pleth_trace_enabled(p) ++ if matches!(channel, Channel::Pleth) ++ && (!pleth_trace_enabled(p) ++ || p.spo2_status(sim.pulse_rate()) != Spo2Status::Available) + { + let _ = cr.restore(); + return; +@@ -544,8 +545,7 @@ mod tests { + p.spo2_sensor_attached = true; + p.spo2_quality = Spo2Quality::None; + assert!(!pleth_trace_enabled(&p)); +- assert_eq!(spo2_vitals(&p, Some(75)).1, "--"); +- assert!(spo2_vitals(&p, Some(75)).2.contains("NO SIGNAL")); ++ assert_eq!(spo2_vitals(&p, Some(75)).1, "NO READING"); + assert!(spo2_vitals(&p, Some(75)).2.contains("PR --")); + assert!(p.show_spo2); // no readings, but visible row and status + } +@@ -559,10 +559,20 @@ mod tests { + assert!(spo2_vitals(&p, Some(75)).2.contains("PR 75 bpm")); + p.spo2_quality = Spo2Quality::Good; + assert_eq!(spo2_vitals(&p, Some(75)).0, "SpO₂ ★★★"); +- assert_eq!(spo2_vitals(&p, None).1, "--"); ++ assert_eq!(spo2_vitals(&p, None).1, "NO READING"); + assert!(spo2_vitals(&p, None).2.contains("PR --")); + } + ++ #[test] ++ fn no_sensor_precedes_no_reading_and_both_are_spo2_alarms() { ++ let mut p = Parameters::default(); ++ assert_eq!(spo2_vitals(&p, None).1, "NO READING"); ++ p.ecg_rhythm = crate::model::EcgRhythm::PulselessVentricularTachycardia; ++ assert_eq!(spo2_vitals(&p, Some(100)).1, "NO READING"); ++ p.spo2_sensor_attached = false; ++ assert_eq!(spo2_vitals(&p, Some(100)).1, "NO SENSOR"); ++ } ++ + #[test] + fn arterial_axis_is_absolute_and_fixed_to_200_mmhg() { + let p = Parameters::default(); +diff --git a/src/simulation.rs b/src/simulation.rs +index f3d7b01..a9f5c7b 100644 +--- a/src/simulation.rs ++++ b/src/simulation.rs +@@ -109,7 +109,7 @@ impl Simulator { + + if params.ecg_rhythm != self.previous_rhythm + || params.pulse_conduction != self.previous_conduction +- || !params.ecg_rhythm.has_qrs() ++ || !params.ecg_rhythm.can_generate_pulse() + || params.pulse_conduction == PulseConduction::None + || params.heart_rate <= 0 + { +@@ -146,7 +146,8 @@ impl Simulator { + // Interpolate within the 4 ms sample so mechanical onsets stay aligned. + let qrs_time = self.time - SAMPLE_STEP * (next_phase - QRS_PHASE) / increment; + self.ecg_beat_number += 1; +- if params.pulse_conduction.conducts(self.ecg_beat_number) { ++ if params.ecg_rhythm.can_generate_pulse() ++ && params.pulse_conduction.conducts(self.ecg_beat_number) { + let pulse_pressure_scale = if params.respiratory_rate > 0 { + ppv_multiplier(params.pulse_pressure_variation, self.respiratory_phase) + } else { +@@ -208,7 +209,14 @@ impl Simulator { + } + } + +- let art = if let Some(age) = latest_art_age { ++ let art = if !params.ecg_rhythm.can_generate_pulse() ++ || params.pulse_conduction == PulseConduction::None ++ || params.heart_rate <= 0 ++ { ++ // Low-frequency baseline drift around zero, without pulsations. ++ // The smooth, deterministic noise stays within 0..5 mmHg. ++ pulseless_arterial_drift(self.time) ++ } else if let Some(age) = latest_art_age { + // Pressure decays after an unperfused interval instead of showing a + // non-existent 75 mmHg baseline during prolonged missed captures. + let baseline = diastolic * (-(age - 0.60).max(0.0) / 1.40).exp(); +@@ -220,6 +228,28 @@ impl Simulator { + } + } + ++/// Deterministic smooth value noise with a slow, non-cardiac frequency. ++fn smooth_random_unit(time: f64, seconds_per_step: f64, seed: i64) -> f64 { ++ fn hash(index: i64) -> f64 { ++ let mut x = (index as u64).wrapping_add(0x9E37_79B9_7F4A_7C15); ++ x = (x ^ (x >> 30)).wrapping_mul(0xBF58_476D_1CE4_E5B9); ++ x = (x ^ (x >> 27)).wrapping_mul(0x94D0_49BB_1331_11EB); ++ x ^= x >> 31; ++ (x as f64) / (u64::MAX as f64) ++ } ++ let position = time / seconds_per_step; ++ let index = position.floor() as i64; ++ let delta = position - index as f64; ++ let fade = delta * delta * (3.0 - 2.0 * delta); ++ hash(index.wrapping_add(seed)) * (1.0 - fade) ++ + hash(index.wrapping_add(seed).wrapping_add(1)) * fade ++} ++ ++fn pulseless_arterial_drift(time: f64) -> f64 { ++ (0.4 + 3.6 * smooth_random_unit(time, 2.4, 12) ++ + 0.65 * smooth_random_unit(time, 0.95, 41)).clamp(0.0, 5.0) ++} ++ + fn gaussian(x: f64, center: f64, width: f64) -> f64 { + let d = (x - center) / width; + (-0.5 * d * d).exp() +@@ -281,7 +311,7 @@ fn ecg_amplitude(phase: f64, time: f64, rhythm: EcgRhythm, heart_rate: i32) -> f + - 0.32 * lobe(0.028, 0.012) + + 0.28 * lobe(t_after_qrs, t_width) + } +- EcgRhythm::VentricularTachycardia => { ++ EcgRhythm::VentricularTachycardia | EcgRhythm::PulselessVentricularTachycardia => { + // Broad monomorphic ventricular complexes, also in milliseconds. + 1.06 * lobe(0.0, 0.045) + - 0.49 * lobe(0.068, 0.030) +@@ -389,13 +419,14 @@ mod tests { + for (rhythm, capture) in [ + (EcgRhythm::Asystole, PulseConduction::OneToOne), + (EcgRhythm::VentricularFibrillation, PulseConduction::OneToOne), ++ (EcgRhythm::PulselessVentricularTachycardia, PulseConduction::OneToOne), + (EcgRhythm::Sinus, PulseConduction::None), + ] { + let p = Parameters { ecg_rhythm: rhythm, pulse_conduction: capture, ..Parameters::default() }; + let mut sim = Simulator::new(&p); + for _ in 0..250 { sim.step(&p); } + assert!(sim.pulse_rate().is_none()); +- assert!(sim.samples.iter().all(|s| s.art == 0.0 && s.pleth == 0.0)); ++ assert!(sim.samples.iter().all(|s| (0.0..=5.0).contains(&s.art) && s.pleth == 0.0)); + } + } + +@@ -407,10 +438,44 @@ mod tests { + p.pulse_conduction = PulseConduction::None; + sim.step(&p); + assert!(sim.pulse_rate().is_none()); +- assert_eq!(sim.samples.back().unwrap().art, 0.0); ++ assert!((0.0..=5.0).contains(&sim.samples.back().unwrap().art)); + assert_eq!(sim.samples.back().unwrap().pleth, 0.0); + } + ++ #[test] ++ fn vt_remains_perfusing_and_pvt_has_qrs_but_no_pulse() { ++ let mut p = Parameters { ++ ecg_rhythm: EcgRhythm::VentricularTachycardia, ++ heart_rate: 160, ++ ..Parameters::default() ++ }; ++ let mut sim = Simulator::new(&p); ++ assert_eq!(sim.pulse_rate(), Some(160)); ++ assert!(sim.samples().iter().any(|s| s.art > 70.0 && s.pleth > 0.0)); ++ p.ecg_rhythm = EcgRhythm::PulselessVentricularTachycardia; ++ sim.step(&p); ++ assert_eq!(sim.pulse_rate(), None); ++ assert!((0.0..=5.0).contains(&sim.samples().back().unwrap().art)); ++ assert_eq!(sim.samples().back().unwrap().pleth, 0.0); ++ for _ in 0..500 { sim.step(&p); } ++ assert!(sim.samples().iter().rev().take(500) ++ .all(|s| (0.0..=5.0).contains(&s.art) && s.pleth == 0.0)); ++ assert!(sim.samples().iter().rev().take(500) ++ .any(|s| s.ecg.abs() > 0.3)); ++ } ++ ++ #[test] ++ fn low_pressure_drift_is_smooth_and_never_pulsatile() { ++ let values: Vec = (0..5000) ++ .map(|n| pulseless_arterial_drift(n as f64 * SAMPLE_STEP)) ++ .collect(); ++ assert!(values.iter().all(|v| (0.0..=5.0).contains(v))); ++ assert!(values.windows(2).all(|w| (w[1] - w[0]).abs() < 0.10)); ++ let spread = values.iter().copied().fold(f64::NEG_INFINITY, f64::max) ++ - values.iter().copied().fold(f64::INFINITY, f64::min); ++ assert!(spread > 0.25); ++ } ++ + #[test] + fn pulse_rate_follows_two_to_one_capture() { + let p = Parameters { pulse_conduction: PulseConduction::TwoToOne, ..Parameters::default() }; +diff --git a/src/ui.rs b/src/ui.rs +index a36fec3..669c227 100644 +--- a/src/ui.rs ++++ b/src/ui.rs +@@ -146,14 +146,15 @@ fn create_admin(app: &Application, params: SharedParams, + let ecg = group(&controls, "ECG"); + add_visibility(&ecg, params.borrow().show_ecg, params.clone(), |p, show| p.show_ecg = show); + add_dropdown(&ecg, "ECG rhythm", &[ +- "Sinus rhythm", "Atrial fibrillation", "Ventricular tachycardia", +- "Ventricular fibrillation", "Asystole", ++ "Sinus rhythm", "Atrial fibrillation", "Ventricular tachycardia (VT)", ++ "Pulseless ventricular tachycardia (PVT)", "Ventricular fibrillation", "Asystole", + ], params.clone(), |p, selected| { + p.ecg_rhythm = match selected { + 1 => EcgRhythm::AtrialFibrillation, + 2 => EcgRhythm::VentricularTachycardia, +- 3 => EcgRhythm::VentricularFibrillation, +- 4 => EcgRhythm::Asystole, ++ 3 => EcgRhythm::PulselessVentricularTachycardia, ++ 4 => EcgRhythm::VentricularFibrillation, ++ 5 => EcgRhythm::Asystole, + _ => EcgRhythm::Sinus, + }; + }); +@@ -210,7 +211,7 @@ fn create_admin(app: &Application, params: SharedParams, + }); + let conduction_hint = gtk::Label::new(Some( + "Pulse rate is derived from captured QRS events. +-ART and pleth are delayed; VF and asystole always have no pulse." ++ART and pleth are delayed. VT can be perfusing; PVT, VF and asystole are pulseless." + )); + conduction_hint.set_xalign(0.0); + conduction_hint.set_wrap(true); diff --git a/patient-monitor-simulation/Cargo.lock b/patient-monitor-simulation/Cargo.lock index ad3e357..f84a1e5 100644 --- a/patient-monitor-simulation/Cargo.lock +++ b/patient-monitor-simulation/Cargo.lock @@ -438,7 +438,7 @@ dependencies = [ [[package]] name = "patient-monitor-simulation" -version = "0.4.1" +version = "0.4.2" dependencies = [ "gtk4", ] diff --git a/patient-monitor-simulation/Cargo.toml b/patient-monitor-simulation/Cargo.toml index 4c97d45..02a5d17 100644 --- a/patient-monitor-simulation/Cargo.toml +++ b/patient-monitor-simulation/Cargo.toml @@ -1,6 +1,6 @@ [package] name = "patient-monitor-simulation" -version = "0.4.1" +version = "0.4.2" edition = "2021" license = "MIT" description = "Synthetic patient-monitor simulation for teaching (not for clinical use)" diff --git a/patient-monitor-simulation/README.md b/patient-monitor-simulation/README.md index 4c5b8f0..c693e16 100644 --- a/patient-monitor-simulation/README.md +++ b/patient-monitor-simulation/README.md @@ -1,4 +1,4 @@ -# Patient Monitor Simulation (PaMSim) — v0.4.1 +# Patient Monitor Simulation (PaMSim) — v0.4.2 A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux. @@ -130,7 +130,7 @@ Admin → **Pulse oximetry** has two additional controls: | Setting | Pleth waveform | Monitor display | | --- | --- | --- | -| **0 — None** | No waveform | SpO₂ `--`, PR `--`, **NO SIGNAL**; no stars | +| **0 — None** | No waveform | Flashing **NO READING**, PR `--`; no stars | | **1 — Poor** | Small, irregularly amplitude-distorted pulse | 1 star (★) | | **2 — Adequate** | Medium, smoothly damped pulse | 2 stars (★★) | | **3 — Good** | Full nominal, smoothly damped pulse | 3 stars (★★★) | @@ -143,7 +143,7 @@ remains derived from mechanically captured QRS complexes. The degraded waveform uses deterministic, smoothly interpolated pseudo-noise that scales only existing pleth pulses: it cannot manufacture pulses during -PEA, ventricular fibrillation or asystole. Unplugging a sensor or selecting +PEA, PVT, ventricular fibrillation or asystole. Unplugging a sensor or selecting quality 0 hides even previously buffered pleth samples immediately. ECG and ART continue unaffected. The **Show on monitor** checkbox still hides the entire SpO₂ row; sensor/quality controls leave the row visible so the status @@ -151,15 +151,18 @@ can be taught. ## ECG and mechanical coupling -- ECG rhythms: sinus, atrial fibrillation, monomorphic ventricular tachycardia, +- ECG rhythms: sinus, atrial fibrillation, monomorphic ventricular tachycardia + (potentially perfusing), pulseless ventricular tachycardia (PVT), ventricular fibrillation and asystole. - Mechanical capture: **1:1**, **2:1**, **3:1**, **None (PEA)**, or deterministic pseudo-random capture (~65%). PR is derived from conducted QRS events, never controlled by a pulse-rate slider. - A captured QRS leads to an ART upstroke after a schematic **120 ms**, and a peripheral pleth pulse after **300 ms**. Pleth is strongly damped/filtered. -- VF, asystole and PEA suppress mechanical pulses; old samples scroll out of - view. NIBP is a static, separately entered cuff reading. +- PVT, VF, asystole and PEA suppress mechanical pulses; the ART trace then + drifts smoothly at 0–5 mmHg rather than representing a pulsatile pressure. + Previous pressure samples scroll out of view. NIBP is a static, + separately entered cuff reading. ## Invasive arterial pressure and PPV (new in v0.3) @@ -205,7 +208,7 @@ The five **Show on monitor** checkboxes affect the presentation only: | Checkbox | Hidden monitor content | | --- | --- | -| ECG | ECG waveform, HR and rhythm label | +| ECG | ECG waveform, HR and rhythm alarm (when present) | | Pulse oximetry | Pleth waveform, SpO₂ and PR | | Invasive arterial blood pressure | ART waveform, pressure values, MAP and PPV label | | Capnography | CO₂ waveform, EtCO₂ and RR | @@ -287,3 +290,13 @@ were not available in the environment where this ZIP was prepared. **Build verification:** ZIP integrity and patch application were checked. The GTK4 application and Rust tests were not compiled in the packaging environment; run `cargo test` and `cargo run --release` on Fedora. + + +## v0.4.2 — Rhythm, sensor and missing-reading alarms + +- **VT** remains potentially perfusing. The new **PVT** (pulseless ventricular tachycardia) rhythm retains organized broad QRS complexes but produces no arterial/pleth pulses. VF and asystole are also pulseless regardless of capture selection. +- **ECG**: a flashing **ARRHYTHMIA** message for VT, PVT and VF; a flashing **ASYSTOLE** message for asystole. These event alarms do not depend on numerical HR limits. +- **SpO₂**: when the probe is disconnected, a flashing **NO SENSOR** replaces the saturation reading. Quality 0, loss of mechanical capture or a pulseless rhythm results in flashing **NO READING** (no numerical SpO₂/PR). Sensor disconnection takes precedence. No pleth waveform is displayed in these conditions. +- **ART**: without mechanical pulses (including PVT/VF/asystole/PEA), the simulated invasive pressure line has slow non-pulsatile drift between **0 and 5 mmHg**. The numerical blood-pressure reading remains unavailable (`--/--`), rather than misrepresenting this baseline as true systolic and diastolic pressures. +- **ECG rhythm name** has been removed from the monitor; only HR and the associated alarm message, when present, are visible. The instructor continues to select the rhythm in Admin. +- Numerical alarm thresholds and the Adult preset from v0.4.1 are unchanged. Synthetic demonstration behavior only; not suitable for clinical decisions. diff --git a/patient-monitor-simulation/src/model.rs b/patient-monitor-simulation/src/model.rs index 2ce532c..6b1f6d1 100644 --- a/patient-monitor-simulation/src/model.rs +++ b/patient-monitor-simulation/src/model.rs @@ -5,15 +5,40 @@ pub enum EcgRhythm { Sinus, AtrialFibrillation, VentricularTachycardia, + PulselessVentricularTachycardia, VentricularFibrillation, Asystole, } impl EcgRhythm { - /// VF and asystole have no organized QRS to trigger a mechanical pulse. + /// Organized electrical QRS complexes. PVT still has electrical QRS complexes. pub fn has_qrs(self) -> bool { !matches!(self, Self::VentricularFibrillation | Self::Asystole) } + + /// Whether a QRS can trigger a mechanical pulse, depending on capture. + /// Perfusing VT is distinct from PVT. VF and asystole have no QRS. + pub fn can_generate_pulse(self) -> bool { + self.has_qrs() && self != Self::PulselessVentricularTachycardia + } + + /// Rhythm alarms are independent of instructor-defined HR thresholds. + pub fn rhythm_alarm(self) -> Option<&'static str> { + match self { + Self::VentricularTachycardia | Self::PulselessVentricularTachycardia + | Self::VentricularFibrillation => Some("ARRHYTHMIA"), + Self::Asystole => Some("ASYSTOLE"), + _ => None, + } + } +} + +/// Pulse-oximeter availability and technical alarms. Sensor loss takes precedence. +#[derive(Clone, Copy, Debug, PartialEq, Eq)] +pub enum Spo2Status { + Available, + NoSensor, + NoReading, } #[derive(Clone, Copy, Debug, PartialEq, Eq)] @@ -195,6 +220,24 @@ pub struct Parameters { pub show_nibp: bool, } +impl Parameters { + /// No saturation without an attached sensor, usable signal quality and + /// two observed mechanical pulse events. Thresholds do not control this alarm. + pub fn spo2_status(&self, pulse_rate: Option) -> Spo2Status { + if !self.spo2_sensor_attached { + Spo2Status::NoSensor + } else if self.spo2_quality == Spo2Quality::None || pulse_rate.is_none() + || !self.ecg_rhythm.can_generate_pulse() + || self.pulse_conduction == PulseConduction::None + || self.heart_rate <= 0 + { + Spo2Status::NoReading + } else { + Spo2Status::Available + } + } +} + impl Default for Parameters { fn default() -> Self { Self { @@ -308,6 +351,41 @@ mod tests { assert!(!p.alarms.pr.enabled()); } + #[test] + fn vt_stays_perfusing_and_pvt_is_electrically_organized_but_pulseless() { + use EcgRhythm::*; + assert!(VentricularTachycardia.has_qrs()); + assert!(VentricularTachycardia.can_generate_pulse()); + assert!(PulselessVentricularTachycardia.has_qrs()); + assert!(!PulselessVentricularTachycardia.can_generate_pulse()); + assert!(!VentricularFibrillation.can_generate_pulse()); + assert!(!Asystole.can_generate_pulse()); + for rhythm in [VentricularTachycardia, PulselessVentricularTachycardia, VentricularFibrillation] { + assert_eq!(rhythm.rhythm_alarm(), Some("ARRHYTHMIA")); + } + assert_eq!(Asystole.rhythm_alarm(), Some("ASYSTOLE")); + assert_eq!(Sinus.rhythm_alarm(), None); + assert_eq!(AtrialFibrillation.rhythm_alarm(), None); + } + + #[test] + fn sensor_and_no_reading_alarms_override_spo2_thresholds() { + let mut p = Parameters::default(); + assert_eq!(p.spo2_status(Some(80)), Spo2Status::Available); + assert_eq!(p.spo2_status(None), Spo2Status::NoReading); + p.spo2_quality = Spo2Quality::None; + assert_eq!(p.spo2_status(Some(80)), Spo2Status::NoReading); + p.spo2_sensor_attached = false; + assert_eq!(p.spo2_status(Some(80)), Spo2Status::NoSensor); + p.spo2_sensor_attached = true; + p.spo2_quality = Spo2Quality::Good; + p.ecg_rhythm = EcgRhythm::PulselessVentricularTachycardia; + assert_eq!(p.spo2_status(Some(80)), Spo2Status::NoReading); + p.ecg_rhythm = EcgRhythm::Sinus; + p.pulse_conduction = PulseConduction::None; + assert_eq!(p.spo2_status(Some(80)), Spo2Status::NoReading); + } + #[test] fn grouped_mechanical_capture_follows_requested_patterns() { assert_eq!((1..=8).filter(|&b| PulseConduction::TwoToOne.conducts(b)).collect::>(), diff --git a/patient-monitor-simulation/src/render.rs b/patient-monitor-simulation/src/render.rs index 8391fe8..c0f8474 100644 --- a/patient-monitor-simulation/src/render.rs +++ b/patient-monitor-simulation/src/render.rs @@ -1,7 +1,7 @@ //! Size-independent Cairo drawing of the synthetic bedside monitor. use gtk::cairo::{Context, FontSlant, FontWeight, LineCap, LineJoin}; -use crate::model::{mean_arterial_pressure, AlarmLimits, AlarmState, EcgRhythm, Parameters, PulseConduction, Spo2Quality}; +use crate::model::{mean_arterial_pressure, AlarmLimits, AlarmState, Parameters, PulseConduction, Spo2Quality, Spo2Status}; use crate::simulation::{Sample, Simulator}; type Color = (f64, f64, f64); @@ -106,17 +106,17 @@ fn pleth_trace_enabled(p: &Parameters) -> bool { } fn spo2_vitals(p: &Parameters, pulse_rate: Option) -> (String, String, String) { - if !p.spo2_sensor_attached { - return ("SpO₂".to_owned(), "NO SENSOR".to_owned(), "SpO₂ -- PR -- bpm".to_owned()); + match p.spo2_status(pulse_rate) { + Spo2Status::NoSensor => ( + "SpO₂".to_owned(), "NO SENSOR".to_owned(), "PR -- bpm".to_owned()), + Spo2Status::NoReading => ( + "SpO₂".to_owned(), "NO READING".to_owned(), "PR -- bpm".to_owned()), + Spo2Status::Available => ( + format!("SpO₂ {}", p.spo2_quality.stars()), + p.spo2.to_string(), + format!("% PR {} bpm", pulse_rate.unwrap_or_default()), + ), } - if p.spo2_quality == Spo2Quality::None { - return ("SpO₂".to_owned(), "--".to_owned(), "NO SIGNAL PR -- bpm".to_owned()); - } - ( - format!("SpO₂ {}", p.spo2_quality.stars()), - if pulse_rate.is_some() { p.spo2.to_string() } else { "--".to_owned() }, - format!("% PR {} bpm", pulse_rate.map_or("--".to_owned(), |pr| pr.to_string())), - ) } fn alarmed(limits: AlarmLimits, value: Option) -> bool { @@ -136,16 +136,15 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64, let number_size = (row_h * 0.375).min(width * 0.26).clamp(16.0, 59.0); let sub_size = (row_h * 0.16).clamp(11.0, 22.0) * 0.85; let flash = alarm_flash_on(sim); - let has_capture = p.ecg_rhythm.has_qrs() + let has_capture = p.ecg_rhythm.can_generate_pulse() && p.heart_rate > 0 && p.pulse_conduction != PulseConduction::None; let pulse_rate = if has_capture { sim.pulse_rate() } else { None }; let ecg_hr = if p.ecg_rhythm.has_qrs() && p.heart_rate > 0 { Some(p.heart_rate) } else { None }; - let oxygen = if pleth_trace_enabled(p) && pulse_rate.is_some() { - Some(p.spo2) - } else { None }; + let spo2_status = p.spo2_status(pulse_rate); + let oxygen = if spo2_status == Spo2Status::Available { Some(p.spo2) } else { None }; let art_map = mean_arterial_pressure(p.art_systolic, p.art_diastolic); let limits: Vec<(&str, AlarmLimits)> = match ch { @@ -165,23 +164,23 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64, draw_alarm_number(cr, &ecg_hr.map_or("--".to_owned(), |v| v.to_string()), x, value_y, number_size, width, color, alarmed(p.alarms.hr, ecg_hr), flash); - let rhythm = match p.ecg_rhythm { - EcgRhythm::Sinus => "Sinus", - EcgRhythm::AtrialFibrillation => "AF", - EcgRhythm::VentricularTachycardia => "VT", - EcgRhythm::VentricularFibrillation => "VF", - EcgRhythm::Asystole => "Asystole", - }; - text(cr, &format!("bpm · {}", rhythm), x, info_y, sub_size, color, false); + // Show only the clinical alarm message, never the selected ECG rhythm. + if let Some(message) = p.ecg_rhythm.rhythm_alarm() { + draw_alarm_number(cr, message, x, info_y, sub_size * 1.1, + width, color, true, flash); + } else { + text(cr, "bpm", x, info_y, sub_size, color, false); + } } Channel::Pleth => { let (label, value, info) = spo2_vitals(p, pulse_rate); text(cr, &label, x, top + row_h * 0.24, label_size, color, false); - let value_size = if value == "NO SENSOR" { - number_size.min(0.19 * width).min(26.0) + let technical_alarm = spo2_status != Spo2Status::Available; + let value_size = if technical_alarm { + number_size.min(0.17 * width).min(26.0) } else { number_size }; draw_alarm_number(cr, &value, x, value_y, value_size, - width, color, alarmed(p.alarms.spo2, oxygen), flash); + width, color, technical_alarm || alarmed(p.alarms.spo2, oxygen), flash); if oxygen.is_some() { draw_alarm_inline(cr, x, info_y, sub_size, width, color, "% PR ", &pulse_rate.unwrap_or_default().to_string(), " bpm", @@ -377,7 +376,9 @@ fn draw_trace(cr: &Context, channel: Channel, color: Color, } // Disconnected or absent pleth signal: no curve, including historical pulses. - if matches!(channel, Channel::Pleth) && !pleth_trace_enabled(p) + if matches!(channel, Channel::Pleth) + && (!pleth_trace_enabled(p) + || p.spo2_status(sim.pulse_rate()) != Spo2Status::Available) { let _ = cr.restore(); return; @@ -544,8 +545,7 @@ mod tests { p.spo2_sensor_attached = true; p.spo2_quality = Spo2Quality::None; assert!(!pleth_trace_enabled(&p)); - assert_eq!(spo2_vitals(&p, Some(75)).1, "--"); - assert!(spo2_vitals(&p, Some(75)).2.contains("NO SIGNAL")); + assert_eq!(spo2_vitals(&p, Some(75)).1, "NO READING"); assert!(spo2_vitals(&p, Some(75)).2.contains("PR --")); assert!(p.show_spo2); // no readings, but visible row and status } @@ -559,10 +559,20 @@ mod tests { assert!(spo2_vitals(&p, Some(75)).2.contains("PR 75 bpm")); p.spo2_quality = Spo2Quality::Good; assert_eq!(spo2_vitals(&p, Some(75)).0, "SpO₂ ★★★"); - assert_eq!(spo2_vitals(&p, None).1, "--"); + assert_eq!(spo2_vitals(&p, None).1, "NO READING"); assert!(spo2_vitals(&p, None).2.contains("PR --")); } + #[test] + fn no_sensor_precedes_no_reading_and_both_are_spo2_alarms() { + let mut p = Parameters::default(); + assert_eq!(spo2_vitals(&p, None).1, "NO READING"); + p.ecg_rhythm = crate::model::EcgRhythm::PulselessVentricularTachycardia; + assert_eq!(spo2_vitals(&p, Some(100)).1, "NO READING"); + p.spo2_sensor_attached = false; + assert_eq!(spo2_vitals(&p, Some(100)).1, "NO SENSOR"); + } + #[test] fn arterial_axis_is_absolute_and_fixed_to_200_mmhg() { let p = Parameters::default(); diff --git a/patient-monitor-simulation/src/simulation.rs b/patient-monitor-simulation/src/simulation.rs index f3d7b01..a9f5c7b 100644 --- a/patient-monitor-simulation/src/simulation.rs +++ b/patient-monitor-simulation/src/simulation.rs @@ -109,7 +109,7 @@ impl Simulator { if params.ecg_rhythm != self.previous_rhythm || params.pulse_conduction != self.previous_conduction - || !params.ecg_rhythm.has_qrs() + || !params.ecg_rhythm.can_generate_pulse() || params.pulse_conduction == PulseConduction::None || params.heart_rate <= 0 { @@ -146,7 +146,8 @@ impl Simulator { // Interpolate within the 4 ms sample so mechanical onsets stay aligned. let qrs_time = self.time - SAMPLE_STEP * (next_phase - QRS_PHASE) / increment; self.ecg_beat_number += 1; - if params.pulse_conduction.conducts(self.ecg_beat_number) { + if params.ecg_rhythm.can_generate_pulse() + && params.pulse_conduction.conducts(self.ecg_beat_number) { let pulse_pressure_scale = if params.respiratory_rate > 0 { ppv_multiplier(params.pulse_pressure_variation, self.respiratory_phase) } else { @@ -208,7 +209,14 @@ impl Simulator { } } - let art = if let Some(age) = latest_art_age { + let art = if !params.ecg_rhythm.can_generate_pulse() + || params.pulse_conduction == PulseConduction::None + || params.heart_rate <= 0 + { + // Low-frequency baseline drift around zero, without pulsations. + // The smooth, deterministic noise stays within 0..5 mmHg. + pulseless_arterial_drift(self.time) + } else if let Some(age) = latest_art_age { // Pressure decays after an unperfused interval instead of showing a // non-existent 75 mmHg baseline during prolonged missed captures. let baseline = diastolic * (-(age - 0.60).max(0.0) / 1.40).exp(); @@ -220,6 +228,28 @@ impl Simulator { } } +/// Deterministic smooth value noise with a slow, non-cardiac frequency. +fn smooth_random_unit(time: f64, seconds_per_step: f64, seed: i64) -> f64 { + fn hash(index: i64) -> f64 { + let mut x = (index as u64).wrapping_add(0x9E37_79B9_7F4A_7C15); + x = (x ^ (x >> 30)).wrapping_mul(0xBF58_476D_1CE4_E5B9); + x = (x ^ (x >> 27)).wrapping_mul(0x94D0_49BB_1331_11EB); + x ^= x >> 31; + (x as f64) / (u64::MAX as f64) + } + let position = time / seconds_per_step; + let index = position.floor() as i64; + let delta = position - index as f64; + let fade = delta * delta * (3.0 - 2.0 * delta); + hash(index.wrapping_add(seed)) * (1.0 - fade) + + hash(index.wrapping_add(seed).wrapping_add(1)) * fade +} + +fn pulseless_arterial_drift(time: f64) -> f64 { + (0.4 + 3.6 * smooth_random_unit(time, 2.4, 12) + + 0.65 * smooth_random_unit(time, 0.95, 41)).clamp(0.0, 5.0) +} + fn gaussian(x: f64, center: f64, width: f64) -> f64 { let d = (x - center) / width; (-0.5 * d * d).exp() @@ -281,7 +311,7 @@ fn ecg_amplitude(phase: f64, time: f64, rhythm: EcgRhythm, heart_rate: i32) -> f - 0.32 * lobe(0.028, 0.012) + 0.28 * lobe(t_after_qrs, t_width) } - EcgRhythm::VentricularTachycardia => { + EcgRhythm::VentricularTachycardia | EcgRhythm::PulselessVentricularTachycardia => { // Broad monomorphic ventricular complexes, also in milliseconds. 1.06 * lobe(0.0, 0.045) - 0.49 * lobe(0.068, 0.030) @@ -389,13 +419,14 @@ mod tests { for (rhythm, capture) in [ (EcgRhythm::Asystole, PulseConduction::OneToOne), (EcgRhythm::VentricularFibrillation, PulseConduction::OneToOne), + (EcgRhythm::PulselessVentricularTachycardia, PulseConduction::OneToOne), (EcgRhythm::Sinus, PulseConduction::None), ] { let p = Parameters { ecg_rhythm: rhythm, pulse_conduction: capture, ..Parameters::default() }; let mut sim = Simulator::new(&p); for _ in 0..250 { sim.step(&p); } assert!(sim.pulse_rate().is_none()); - assert!(sim.samples.iter().all(|s| s.art == 0.0 && s.pleth == 0.0)); + assert!(sim.samples.iter().all(|s| (0.0..=5.0).contains(&s.art) && s.pleth == 0.0)); } } @@ -407,10 +438,44 @@ mod tests { p.pulse_conduction = PulseConduction::None; sim.step(&p); assert!(sim.pulse_rate().is_none()); - assert_eq!(sim.samples.back().unwrap().art, 0.0); + assert!((0.0..=5.0).contains(&sim.samples.back().unwrap().art)); assert_eq!(sim.samples.back().unwrap().pleth, 0.0); } + #[test] + fn vt_remains_perfusing_and_pvt_has_qrs_but_no_pulse() { + let mut p = Parameters { + ecg_rhythm: EcgRhythm::VentricularTachycardia, + heart_rate: 160, + ..Parameters::default() + }; + let mut sim = Simulator::new(&p); + assert_eq!(sim.pulse_rate(), Some(160)); + assert!(sim.samples().iter().any(|s| s.art > 70.0 && s.pleth > 0.0)); + p.ecg_rhythm = EcgRhythm::PulselessVentricularTachycardia; + sim.step(&p); + assert_eq!(sim.pulse_rate(), None); + assert!((0.0..=5.0).contains(&sim.samples().back().unwrap().art)); + assert_eq!(sim.samples().back().unwrap().pleth, 0.0); + for _ in 0..500 { sim.step(&p); } + assert!(sim.samples().iter().rev().take(500) + .all(|s| (0.0..=5.0).contains(&s.art) && s.pleth == 0.0)); + assert!(sim.samples().iter().rev().take(500) + .any(|s| s.ecg.abs() > 0.3)); + } + + #[test] + fn low_pressure_drift_is_smooth_and_never_pulsatile() { + let values: Vec = (0..5000) + .map(|n| pulseless_arterial_drift(n as f64 * SAMPLE_STEP)) + .collect(); + assert!(values.iter().all(|v| (0.0..=5.0).contains(v))); + assert!(values.windows(2).all(|w| (w[1] - w[0]).abs() < 0.10)); + let spread = values.iter().copied().fold(f64::NEG_INFINITY, f64::max) + - values.iter().copied().fold(f64::INFINITY, f64::min); + assert!(spread > 0.25); + } + #[test] fn pulse_rate_follows_two_to_one_capture() { let p = Parameters { pulse_conduction: PulseConduction::TwoToOne, ..Parameters::default() }; diff --git a/patient-monitor-simulation/src/ui.rs b/patient-monitor-simulation/src/ui.rs index a36fec3..669c227 100644 --- a/patient-monitor-simulation/src/ui.rs +++ b/patient-monitor-simulation/src/ui.rs @@ -146,14 +146,15 @@ fn create_admin(app: &Application, params: SharedParams, let ecg = group(&controls, "ECG"); add_visibility(&ecg, params.borrow().show_ecg, params.clone(), |p, show| p.show_ecg = show); add_dropdown(&ecg, "ECG rhythm", &[ - "Sinus rhythm", "Atrial fibrillation", "Ventricular tachycardia", - "Ventricular fibrillation", "Asystole", + "Sinus rhythm", "Atrial fibrillation", "Ventricular tachycardia (VT)", + "Pulseless ventricular tachycardia (PVT)", "Ventricular fibrillation", "Asystole", ], params.clone(), |p, selected| { p.ecg_rhythm = match selected { 1 => EcgRhythm::AtrialFibrillation, 2 => EcgRhythm::VentricularTachycardia, - 3 => EcgRhythm::VentricularFibrillation, - 4 => EcgRhythm::Asystole, + 3 => EcgRhythm::PulselessVentricularTachycardia, + 4 => EcgRhythm::VentricularFibrillation, + 5 => EcgRhythm::Asystole, _ => EcgRhythm::Sinus, }; }); @@ -210,7 +211,7 @@ fn create_admin(app: &Application, params: SharedParams, }); let conduction_hint = gtk::Label::new(Some( "Pulse rate is derived from captured QRS events. -ART and pleth are delayed; VF and asystole always have no pulse." +ART and pleth are delayed. VT can be perfusing; PVT, VF and asystole are pulseless." )); conduction_hint.set_xalign(0.0); conduction_hint.set_wrap(true);