--- a/Cargo.toml +++ b/Cargo.toml @@ -1,6 +1,6 @@ [package] name = "patient-monitor-simulation" -version = "0.3.1" +version = "0.3.2" edition = "2021" license = "MIT" description = "Synthetic patient-monitor simulation for teaching (not for clinical use)" --- a/README.md +++ b/README.md @@ -1,4 +1,4 @@ -# Patient Monitor Simulation (PaMSim) — v0.3.1 +# Patient Monitor Simulation (PaMSim) — v0.3.2 A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux. @@ -20,14 +20,17 @@ ## Windows -**Admin:** Controls ECG rhythm and rate; mechanical capture; SpO₂; invasive -arterial pressure, waveform shape and pulse-pressure variation; NIBP; and -capnography. Numeric inputs have bidirectionally linked sliders and text fields. +**Admin:** Controls patient name; ECG rhythm and rate; mechanical capture; +SpO₂, signal quality and sensor connection; invasive arterial pressure, +waveform shape and pulse-pressure variation; NIBP; and capnography. Numeric inputs have bidirectionally linked sliders and text fields. Each of the five monitor parameters (ECG, SpO₂/pleth, ART, CO₂, NIBP) has its own **Show on monitor** checkbox. **Monitor:** Black background; ECG green, pleth yellow, ART red and capnogram -light grey. Waveforms and vital signs disappear together when their respective +light grey. The patient name entered in Admin replaces **PATIENT MONITOR** in +the header immediately; leaving the name blank restores the generic title. +Long names are automatically resized or clipped to fit the header. +Waveforms and vital signs disappear together when their respective visibility checkbox is cleared. Remaining waveform rows expand to use the space. Hiding a display channel does **not** stop signal generation or physiological coupling: for example, hiding ECG does not stop ART or pleth pulses. NIBP can @@ -36,6 +39,41 @@ The monitor can be resized and toggled fullscreen with **F11**; **Esc** exits fullscreen. On Wayland, move the monitor to the presentation screen before activating fullscreen. Fullscreen does not lock down the computer. + +## Patient name and pulse oximeter signal state (new in v0.3.2) + +The new **Patient name** text field at the top of Admin immediately replaces the +monitor headline. It is optional; an empty or whitespace-only name displays +**PATIENT MONITOR**. This is a local teaching label, not a patient record. + +Admin → **Pulse oximetry** has two additional controls: + +- **Sensor not attached** (checkbox): immediately removes the pleth waveform, + suppresses SpO₂ and pulse-rate readings, and displays **NO SENSOR** instead + of the numeric saturation. This takes precedence over signal quality. +- **Signal quality** (dropdown), which changes the visible pleth waveform and + quality indicator, independently of the instructor-set SpO₂ percentage: + +| Setting | Pleth waveform | Monitor display | +| --- | --- | --- | +| **0 — None** | No waveform | SpO₂ `--`, PR `--`, **NO SIGNAL**; no stars | +| **1 — Poor** | Small, irregularly amplitude-distorted pulse | 1 star (★) | +| **2 — Adequate** | Medium, smoothly damped pulse | 2 stars (★★) | +| **3 — Good** | Full nominal, smoothly damped pulse | 3 stars (★★★) | + +Default: sensor attached; signal quality **3 — Good**. At levels 1–3, the +instructor-set SpO₂ number is shown only when mechanical pulses are detected. +The signal quality does **not** randomly alter that number: it affects the +pleth morphology and the quality indicator only. The simulated pulse rate +remains derived from mechanically captured QRS complexes. + +The degraded waveform uses deterministic, smoothly interpolated pseudo-noise +that scales only existing pleth pulses: it cannot manufacture pulses during +PEA, ventricular fibrillation or asystole. Unplugging a sensor or selecting +quality 0 hides even previously buffered pleth samples immediately. ECG and +ART continue unaffected. The **Show on monitor** checkbox still hides the +entire SpO₂ row; sensor/quality controls leave the row visible so the status +can be taught. ## ECG and mechanical coupling @@ -161,3 +199,17 @@ **Verification:** The archive is generated from these sources. Run `cargo test` locally to verify the Rust/GTK build; Rust and GTK4 development components were not available in the environment where this ZIP was prepared. + +## Changes in v0.3.2 + +1. Added live patient-name header in Admin/Monitor with blank-name fallback. +2. Added four levels of SpO₂ signal quality, quality stars and an irregular, + low-amplitude pleth waveform for Poor quality. +3. Added **Sensor not attached** with `NO SENSOR` status and suppression of + saturation, pulse rate and pleth waveform. +4. Added tests for signal-quality scaling, displayed readings and disconnected + sensor behavior. + +**Build verification:** ZIP integrity and patch application were checked. +The GTK4 application and Rust tests were not compiled in the packaging +environment; run `cargo test` and `cargo run --release` on Fedora. --- a/src/model.rs +++ b/src/model.rs @@ -58,12 +58,45 @@ Obstructive, } -#[derive(Clone, Copy, Debug)] +/// Instructor-selected plethysmography signal quality; separate from the +/// physiological oxygen-saturation setting and mechanical pulse capture. +#[derive(Clone, Copy, Debug, PartialEq, Eq)] +pub enum Spo2Quality { + None, + Poor, + Adequate, + Good, +} + +impl Spo2Quality { + pub fn stars(self) -> &'static str { + match self { + Self::None => "", + Self::Poor => "★", + Self::Adequate => "★★", + Self::Good => "★★★", + } + } + + pub fn amplitude_scale(self) -> f64 { + match self { + Self::None => 0.0, + Self::Poor => 0.25, + Self::Adequate => 0.56, + Self::Good => 1.0, + } + } +} + +#[derive(Clone, Debug)] pub struct Parameters { + pub patient_name: String, // displayed in the monitor header, blank = generic title pub ecg_rhythm: EcgRhythm, pub heart_rate: i32, // bpm, organized electrical rate; not mechanical pulse rate pub pulse_conduction: PulseConduction, - pub spo2: i32, // % + pub spo2: i32, // %; instructor-set nominal saturation + pub spo2_quality: Spo2Quality, + pub spo2_sensor_attached: bool, pub art_systolic: i32, // mmHg, nominal pressure; display axis 0..200 pub art_diastolic: i32, // mmHg pub arterial_shape: ArterialShape, @@ -84,10 +117,13 @@ impl Default for Parameters { fn default() -> Self { Self { + patient_name: String::new(), ecg_rhythm: EcgRhythm::Sinus, heart_rate: 75, pulse_conduction: PulseConduction::OneToOne, spo2: 98, + spo2_quality: Spo2Quality::Good, + spo2_sensor_attached: true, art_systolic: 120, art_diastolic: 75, arterial_shape: ArterialShape::Normal, @@ -120,6 +156,17 @@ } #[test] + fn spo2_quality_stars_and_amplitude_progress_monotonically() { + assert_eq!(Spo2Quality::None.stars(), ""); + assert_eq!(Spo2Quality::Poor.stars(), "★"); + assert_eq!(Spo2Quality::Adequate.stars(), "★★"); + assert_eq!(Spo2Quality::Good.stars(), "★★★"); + assert_eq!(Spo2Quality::None.amplitude_scale(), 0.0); + assert!(Spo2Quality::Poor.amplitude_scale() < Spo2Quality::Adequate.amplitude_scale()); + assert!(Spo2Quality::Adequate.amplitude_scale() < Spo2Quality::Good.amplitude_scale()); + } + + #[test] fn grouped_mechanical_capture_follows_requested_patterns() { assert_eq!((1..=8).filter(|&b| PulseConduction::TwoToOne.conducts(b)).collect::>(), vec![1, 3, 5, 7]); --- a/src/render.rs +++ b/src/render.rs @@ -1,7 +1,7 @@ //! Size-independent Cairo drawing of the synthetic bedside monitor. use gtk::cairo::{Context, FontSlant, FontWeight, LineCap, LineJoin}; -use crate::model::{mean_arterial_pressure, EcgRhythm, Parameters, PulseConduction}; +use crate::model::{mean_arterial_pressure, EcgRhythm, Parameters, PulseConduction, Spo2Quality}; use crate::simulation::{Sample, Simulator}; type Color = (f64, f64, f64); @@ -43,8 +43,18 @@ let trace_right = (split_x - pad).max(trace_left + 40.0); let text_scale = (w.min(h * 1.7) / 850.0).clamp(0.65, 1.5); - text(cr, "PATIENT MONITOR", pad + 5.0, header * 0.58, 18.0 * text_scale, - LIGHT_GREY, true); + let patient_title = if p.patient_name.trim().is_empty() { + "PATIENT MONITOR" + } else { + p.patient_name.trim() + }; + let title_max_width = if w >= 850.0 { + split_x - pad * 2.0 - 145.0 * text_scale + } else { + split_x - pad * 2.0 + }; + fitted_text(cr, patient_title, pad + 5.0, header * 0.58, + 18.0 * text_scale, title_max_width.max(25.0), LIGHT_GREY); if w >= 850.0 { text(cr, "SIMULATION", split_x - 128.0 * text_scale, header * 0.58, 11.0 * text_scale, MUTED, false); @@ -84,6 +94,24 @@ } } +fn pleth_trace_enabled(p: &Parameters) -> bool { + p.spo2_sensor_attached && p.spo2_quality != Spo2Quality::None +} + +fn spo2_vitals(p: &Parameters, pulse_rate: Option) -> (String, String, String) { + if !p.spo2_sensor_attached { + return ("SpO₂".to_owned(), "NO SENSOR".to_owned(), "SpO₂ -- PR -- bpm".to_owned()); + } + if p.spo2_quality == Spo2Quality::None { + return ("SpO₂".to_owned(), "--".to_owned(), "NO SIGNAL PR -- bpm".to_owned()); + } + ( + format!("SpO₂ {}", p.spo2_quality.stars()), + if pulse_rate.is_some() { p.spo2.to_string() } else { "--".to_owned() }, + format!("% PR {} bpm", pulse_rate.map_or("--".to_owned(), |pr| pr.to_string())), + ) +} + fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64, top: f64, row_h: f64, width: f64, p: &Parameters, sim: &Simulator) { let label_size = (row_h * 0.135).clamp(11.0, 19.0); @@ -95,7 +123,7 @@ let pulse_rate = if has_capture { sim.pulse_rate() } else { None }; let (label, value, info) = match ch { Channel::Ecg => ( - "HR", + "HR".to_owned(), if !p.ecg_rhythm.has_qrs() || p.heart_rate <= 0 { "--".to_owned() } else { p.heart_rate.to_string() }, format!("bpm · {}", match p.ecg_rhythm { @@ -106,13 +134,9 @@ EcgRhythm::Asystole => "Asystole", }), ), - Channel::Pleth => ( - "SpO₂", - if pulse_rate.is_some() { p.spo2.to_string() } else { "--".to_owned() }, - format!("% PR {} bpm", pulse_rate.map_or("--".to_owned(), |pr| pr.to_string())), - ), + Channel::Pleth => spo2_vitals(p, pulse_rate), Channel::Art => ( - "ART", + "ART".to_owned(), if pulse_rate.is_some() { format!("{}/{}", p.art_systolic, p.art_diastolic) } else { "--/--".to_owned() }, @@ -126,13 +150,20 @@ } } else { "MAP -- mmHg".to_owned() }, ), - Channel::Capno => ("EtCO₂", p.etco2.to_string(), + Channel::Capno => ("EtCO₂".to_owned(), p.etco2.to_string(), format!("mmHg RR {} /min", p.respiratory_rate)), }; - text(cr, label, x, top + row_h * 0.24, label_size, color, false); - // Reduce wide BP values so they fit within the sidebar. - let value_size = if matches!(ch, Channel::Art) { number_size * 0.78 } else { number_size }; - text(cr, &value, x, top + row_h * 0.64, value_size, color, true); + text(cr, &label, x, top + row_h * 0.24, label_size, color, false); + // Reduce wide readings so they fit within the sidebar. + let value_size = if value == "NO SENSOR" { + number_size.min(0.19 * width).min(26.0) + } else if matches!(ch, Channel::Art) { + number_size * 0.78 + } else { + number_size + }; + fitted_text(cr, &value, x, top + row_h * 0.64, value_size, + width.max(20.0), color); text(cr, &info, x, top + row_h * 0.87, sub_size * 0.85, color, false); } @@ -175,6 +206,13 @@ right, top + trace_height * 0.5, GRID, 0.7); } + // Disconnected or absent pleth signal: no curve, including historical pulses. + if matches!(channel, Channel::Pleth) && !pleth_trace_enabled(p) + { + let _ = cr.restore(); + return; + } + set_color(cr, color); cr.set_line_width((trace_height * 0.016).clamp(1.2, 2.4)); cr.set_line_cap(LineCap::Round); @@ -194,11 +232,66 @@ fn normalized(channel: Channel, s: &Sample, p: &Parameters) -> f64 { match channel { Channel::Ecg => (0.40 + s.ecg * 0.38).clamp(0.02, 0.98), - Channel::Pleth => (0.10 + s.pleth * 0.78).clamp(0.02, 0.98), + Channel::Pleth => (0.10 + pleth_visual_amplitude(s.pleth, s.time, p.spo2_quality) * 0.78) + .clamp(0.02, 0.98), Channel::Art => (s.art / 200.0).clamp(0.0, 1.0), Channel::Capno => (0.08 + (s.co2 / f64::from(p.etco2.max(1))) * 0.80) .clamp(0.02, 0.98), } +} + +/// Signal degradation is presentation-only: no quality setting can invent +/// pulses or change the ECG/ART generator. The noise is smoothly interpolated +/// and reproducible, so redrawing a sample does not make it flicker. +fn pleth_visual_amplitude(pleth: f64, time: f64, quality: Spo2Quality) -> f64 { + let scale = quality.amplitude_scale(); + if scale == 0.0 || pleth <= 0.0 { return 0.0; } + let distortion = if quality == Spo2Quality::Poor { + (1.0 + 0.55 * smooth_noise(time * 7.0) + + 0.20 * smooth_noise(time * 23.0 + 4.0)).clamp(0.15, 1.75) + } else { + 1.0 + }; + (pleth * scale * distortion).clamp(0.0, 1.0) +} + +fn smooth_noise(position: f64) -> f64 { + let index = position.floor() as i64; + let fraction = position - index as f64; + let smooth = fraction * fraction * (3.0 - 2.0 * fraction); + let a = noise_value(index); + let b = noise_value(index.wrapping_add(1)); + a + (b - a) * smooth +} + +fn noise_value(index: i64) -> f64 { + let mut x = (index as u64).wrapping_mul(0x9E37_79B9_7F4A_7C15); + x ^= x >> 30; + x = x.wrapping_mul(0xBF58_476D_1CE4_E5B9); + x ^= x >> 27; + x = x.wrapping_mul(0x94D0_49BB_1331_11EB); + x ^= x >> 31; + (x as f64 / u64::MAX as f64) * 2.0 - 1.0 +} + +/// Fit a name or numeric/status reading horizontally without changing the +/// other monitor dimensions. For exceptionally long values, clip safely. +fn fitted_text(cr: &Context, value: &str, x: f64, baseline: f64, + nominal_size: f64, available_width: f64, color: Color) { + cr.select_font_face("Sans", FontSlant::Normal, FontWeight::Bold); + cr.set_font_size(nominal_size); + let actual_width = cr.text_extents(value).map(|ext| ext.x_advance()).unwrap_or(0.0); + let fitted_size = if actual_width > available_width && actual_width > 0.0 { + (nominal_size * available_width / actual_width).max(8.0) + } else { + nominal_size + }; + let _ = cr.save(); + cr.rectangle(x, baseline - fitted_size * 1.25, + available_width.max(1.0), fitted_size * 1.55); + cr.clip(); + text(cr, value, x, baseline, fitted_size, color, true); + let _ = cr.restore(); } fn set_color(cr: &Context, c: Color) { @@ -243,6 +336,53 @@ } #[test] + fn pleth_degradation_preserves_capture_timing_and_suppresses_false_pulses() { + let pulse = 0.6; + let t = 1.234; + assert_eq!(pleth_visual_amplitude(pulse, t, Spo2Quality::None), 0.0); + assert_eq!(pleth_visual_amplitude(0.0, t, Spo2Quality::Poor), 0.0); + assert!(pleth_visual_amplitude(pulse, t, Spo2Quality::Poor) + < pleth_visual_amplitude(pulse, t, Spo2Quality::Adequate)); + assert!(pleth_visual_amplitude(pulse, t, Spo2Quality::Adequate) + < pleth_visual_amplitude(pulse, t, Spo2Quality::Good)); + assert_eq!(pleth_visual_amplitude(pulse, t, Spo2Quality::Good), pulse); + assert_eq!(pleth_visual_amplitude(pulse, t, Spo2Quality::Poor), + pleth_visual_amplitude(pulse, t, Spo2Quality::Poor)); + assert_ne!(pleth_visual_amplitude(pulse, t, Spo2Quality::Poor), + pleth_visual_amplitude(pulse, t + 0.5, Spo2Quality::Poor)); + } + + #[test] + fn disconnected_or_no_quality_means_no_pleth_or_spo2_reading() { + let mut p = Parameters::default(); + assert!(pleth_trace_enabled(&p)); + p.spo2_sensor_attached = false; + assert!(!pleth_trace_enabled(&p)); + assert_eq!(spo2_vitals(&p, Some(75)).1, "NO SENSOR"); + assert!(spo2_vitals(&p, Some(75)).2.contains("PR --")); + p.spo2_sensor_attached = true; + p.spo2_quality = Spo2Quality::None; + assert!(!pleth_trace_enabled(&p)); + assert_eq!(spo2_vitals(&p, Some(75)).1, "--"); + assert!(spo2_vitals(&p, Some(75)).2.contains("NO SIGNAL")); + assert!(spo2_vitals(&p, Some(75)).2.contains("PR --")); + assert!(p.show_spo2); // no readings, but visible row and status + } + + #[test] + fn poor_and_good_quality_keep_derived_pr_and_quality_indicators() { + let mut p = Parameters::default(); + p.spo2_quality = Spo2Quality::Poor; + assert_eq!(spo2_vitals(&p, Some(75)).0, "SpO₂ ★"); + assert_eq!(spo2_vitals(&p, Some(75)).1, "98"); + assert!(spo2_vitals(&p, Some(75)).2.contains("PR 75 bpm")); + p.spo2_quality = Spo2Quality::Good; + assert_eq!(spo2_vitals(&p, Some(75)).0, "SpO₂ ★★★"); + assert_eq!(spo2_vitals(&p, None).1, "--"); + assert!(spo2_vitals(&p, None).2.contains("PR --")); + } + + #[test] fn arterial_axis_is_absolute_and_fixed_to_200_mmhg() { let p = Parameters::default(); let mut s = Sample { time: 0.0, ecg: 0.0, pleth: 0.0, art: 100.0, co2: 0.0 }; --- a/src/ui.rs +++ b/src/ui.rs @@ -8,7 +8,7 @@ use gtk::prelude::*; use gtk::{Application, ApplicationWindow, Orientation}; -use crate::model::{ArterialShape, CapnoShape, EcgRhythm, Parameters, PulseConduction}; +use crate::model::{ArterialShape, CapnoShape, EcgRhythm, Parameters, PulseConduction, Spo2Quality}; use crate::render; use crate::simulation::Simulator; @@ -41,7 +41,7 @@ let params = params.clone(); let simulator = simulator.clone(); move |_area, cr, width, height| { - let config = *params.borrow(); + let config = params.borrow(); render::draw(cr, width, height, &config, &simulator.borrow()); } }); @@ -54,7 +54,7 @@ let now = Instant::now(); let elapsed = now.saturating_duration_since(previous.get()).as_secs_f64(); previous.set(now); - let config = *params.borrow(); + let config = params.borrow(); simulator.borrow_mut().advance(elapsed, &config); area.queue_draw(); glib::ControlFlow::Continue @@ -104,6 +104,24 @@ scroller.set_vexpand(true); scroller.set_policy(gtk::PolicyType::Never, gtk::PolicyType::Automatic); let controls = gtk::Box::new(Orientation::Vertical, 12); + + let patient = group(&controls, "Patient"); + let patient_row = gtk::Box::new(Orientation::Horizontal, 8); + let patient_label = gtk::Label::new(Some("Patient name")); + patient_label.set_xalign(0.0); + patient_label.set_width_chars(17); + let name_entry = gtk::Entry::new(); + name_entry.set_hexpand(true); + name_entry.set_max_length(80); + name_entry.set_placeholder_text(Some("Name displayed on monitor")); + name_entry.set_text(¶ms.borrow().patient_name); + name_entry.connect_changed({ + let params = params.clone(); + move |entry| params.borrow_mut().patient_name = entry.text().to_string() + }); + patient_row.append(&patient_label); + patient_row.append(&name_entry); + patient.append(&patient_row); let ecg = group(&controls, "ECG"); add_visibility(&ecg, params.borrow().show_ecg, params.clone(), |p, show| p.show_ecg = show); @@ -126,6 +144,26 @@ add_visibility(&spo2, params.borrow().show_spo2, params.clone(), |p, show| p.show_spo2 = show); add_numeric(&spo2, "SpO₂", "%", 0, 100, params.borrow().spo2, params.clone(), |p, v| p.spo2 = v); + let sensor = gtk::CheckButton::with_label("Sensor not attached"); + sensor.set_active(!params.borrow().spo2_sensor_attached); + sensor.connect_toggled({ + let params = params.clone(); + move |button| params.borrow_mut().spo2_sensor_attached = !button.is_active() + }); + spo2.append(&sensor); + add_dropdown_at(&spo2, "Signal quality", &[ + "0 — None (no reading)", + "1 — Poor (*)", + "2 — Adequate (**)", + "3 — Good (***)", + ], params.borrow().spo2_quality as u32, params.clone(), |p, selected| { + p.spo2_quality = match selected { + 1 => Spo2Quality::Poor, + 2 => Spo2Quality::Adequate, + 3 => Spo2Quality::Good, + _ => Spo2Quality::None, + }; + }); add_dropdown(&spo2, "Mechanical capture", &[ "1:1 (every QRS)", "2:1 (one pulse in two)", @@ -243,11 +281,18 @@ fn add_dropdown(parent: >k::Box, label: &str, items: &[&str], params: SharedParams, setter: F) where F: Fn(&mut Parameters, u32) + 'static { + add_dropdown_at(parent, label, items, 0, params, setter); +} + +fn add_dropdown_at(parent: >k::Box, label: &str, items: &[&str], + initial: u32, params: SharedParams, setter: F) +where F: Fn(&mut Parameters, u32) + 'static { let row = gtk::Box::new(Orientation::Horizontal, 8); let caption = gtk::Label::new(Some(label)); caption.set_xalign(0.0); caption.set_width_chars(17); let combo = gtk::DropDown::from_strings(items); + combo.set_selected(initial); combo.set_hexpand(true); combo.connect_selected_notify(move |combo| { setter(&mut params.borrow_mut(), combo.selected());