diff --git a/Cargo.toml b/Cargo.toml
index 4c97d45..02a5d17 100644
--- a/Cargo.toml
+++ b/Cargo.toml
@@ -1,6 +1,6 @@
[package]
name = "patient-monitor-simulation"
-version = "0.4.1"
+version = "0.4.2"
edition = "2021"
license = "MIT"
description = "Synthetic patient-monitor simulation for teaching (not for clinical use)"
diff --git a/README.md b/README.md
index 4c5b8f0..c693e16 100644
--- a/README.md
+++ b/README.md
@@ -1,4 +1,4 @@
-# Patient Monitor Simulation (PaMSim) — v0.4.1
+# Patient Monitor Simulation (PaMSim) — v0.4.2
A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux.
@@ -130,7 +130,7 @@ Admin → **Pulse oximetry** has two additional controls:
| Setting | Pleth waveform | Monitor display |
| --- | --- | --- |
-| **0 — None** | No waveform | SpO₂ `--`, PR `--`, **NO SIGNAL**; no stars |
+| **0 — None** | No waveform | Flashing **NO READING**, PR `--`; no stars |
| **1 — Poor** | Small, irregularly amplitude-distorted pulse | 1 star (★) |
| **2 — Adequate** | Medium, smoothly damped pulse | 2 stars (★★) |
| **3 — Good** | Full nominal, smoothly damped pulse | 3 stars (★★★) |
@@ -143,7 +143,7 @@ remains derived from mechanically captured QRS complexes.
The degraded waveform uses deterministic, smoothly interpolated pseudo-noise
that scales only existing pleth pulses: it cannot manufacture pulses during
-PEA, ventricular fibrillation or asystole. Unplugging a sensor or selecting
+PEA, PVT, ventricular fibrillation or asystole. Unplugging a sensor or selecting
quality 0 hides even previously buffered pleth samples immediately. ECG and
ART continue unaffected. The **Show on monitor** checkbox still hides the
entire SpO₂ row; sensor/quality controls leave the row visible so the status
@@ -151,15 +151,18 @@ can be taught.
## ECG and mechanical coupling
-- ECG rhythms: sinus, atrial fibrillation, monomorphic ventricular tachycardia,
+- ECG rhythms: sinus, atrial fibrillation, monomorphic ventricular tachycardia
+ (potentially perfusing), pulseless ventricular tachycardia (PVT),
ventricular fibrillation and asystole.
- Mechanical capture: **1:1**, **2:1**, **3:1**, **None (PEA)**, or deterministic
pseudo-random capture (~65%). PR is derived from conducted QRS events, never
controlled by a pulse-rate slider.
- A captured QRS leads to an ART upstroke after a schematic **120 ms**, and a
peripheral pleth pulse after **300 ms**. Pleth is strongly damped/filtered.
-- VF, asystole and PEA suppress mechanical pulses; old samples scroll out of
- view. NIBP is a static, separately entered cuff reading.
+- PVT, VF, asystole and PEA suppress mechanical pulses; the ART trace then
+ drifts smoothly at 0–5 mmHg rather than representing a pulsatile pressure.
+ Previous pressure samples scroll out of view. NIBP is a static,
+ separately entered cuff reading.
## Invasive arterial pressure and PPV (new in v0.3)
@@ -205,7 +208,7 @@ The five **Show on monitor** checkboxes affect the presentation only:
| Checkbox | Hidden monitor content |
| --- | --- |
-| ECG | ECG waveform, HR and rhythm label |
+| ECG | ECG waveform, HR and rhythm alarm (when present) |
| Pulse oximetry | Pleth waveform, SpO₂ and PR |
| Invasive arterial blood pressure | ART waveform, pressure values, MAP and PPV label |
| Capnography | CO₂ waveform, EtCO₂ and RR |
@@ -287,3 +290,13 @@ were not available in the environment where this ZIP was prepared.
**Build verification:** ZIP integrity and patch application were checked.
The GTK4 application and Rust tests were not compiled in the packaging
environment; run `cargo test` and `cargo run --release` on Fedora.
+
+
+## v0.4.2 — Rhythm, sensor and missing-reading alarms
+
+- **VT** remains potentially perfusing. The new **PVT** (pulseless ventricular tachycardia) rhythm retains organized broad QRS complexes but produces no arterial/pleth pulses. VF and asystole are also pulseless regardless of capture selection.
+- **ECG**: a flashing **ARRHYTHMIA** message for VT, PVT and VF; a flashing **ASYSTOLE** message for asystole. These event alarms do not depend on numerical HR limits.
+- **SpO₂**: when the probe is disconnected, a flashing **NO SENSOR** replaces the saturation reading. Quality 0, loss of mechanical capture or a pulseless rhythm results in flashing **NO READING** (no numerical SpO₂/PR). Sensor disconnection takes precedence. No pleth waveform is displayed in these conditions.
+- **ART**: without mechanical pulses (including PVT/VF/asystole/PEA), the simulated invasive pressure line has slow non-pulsatile drift between **0 and 5 mmHg**. The numerical blood-pressure reading remains unavailable (`--/--`), rather than misrepresenting this baseline as true systolic and diastolic pressures.
+- **ECG rhythm name** has been removed from the monitor; only HR and the associated alarm message, when present, are visible. The instructor continues to select the rhythm in Admin.
+- Numerical alarm thresholds and the Adult preset from v0.4.1 are unchanged. Synthetic demonstration behavior only; not suitable for clinical decisions.
diff --git a/src/model.rs b/src/model.rs
index 2ce532c..6b1f6d1 100644
--- a/src/model.rs
+++ b/src/model.rs
@@ -5,15 +5,40 @@ pub enum EcgRhythm {
Sinus,
AtrialFibrillation,
VentricularTachycardia,
+ PulselessVentricularTachycardia,
VentricularFibrillation,
Asystole,
}
impl EcgRhythm {
- /// VF and asystole have no organized QRS to trigger a mechanical pulse.
+ /// Organized electrical QRS complexes. PVT still has electrical QRS complexes.
pub fn has_qrs(self) -> bool {
!matches!(self, Self::VentricularFibrillation | Self::Asystole)
}
+
+ /// Whether a QRS can trigger a mechanical pulse, depending on capture.
+ /// Perfusing VT is distinct from PVT. VF and asystole have no QRS.
+ pub fn can_generate_pulse(self) -> bool {
+ self.has_qrs() && self != Self::PulselessVentricularTachycardia
+ }
+
+ /// Rhythm alarms are independent of instructor-defined HR thresholds.
+ pub fn rhythm_alarm(self) -> Option<&'static str> {
+ match self {
+ Self::VentricularTachycardia | Self::PulselessVentricularTachycardia
+ | Self::VentricularFibrillation => Some("ARRHYTHMIA"),
+ Self::Asystole => Some("ASYSTOLE"),
+ _ => None,
+ }
+ }
+}
+
+/// Pulse-oximeter availability and technical alarms. Sensor loss takes precedence.
+#[derive(Clone, Copy, Debug, PartialEq, Eq)]
+pub enum Spo2Status {
+ Available,
+ NoSensor,
+ NoReading,
}
#[derive(Clone, Copy, Debug, PartialEq, Eq)]
@@ -195,6 +220,24 @@ pub struct Parameters {
pub show_nibp: bool,
}
+impl Parameters {
+ /// No saturation without an attached sensor, usable signal quality and
+ /// two observed mechanical pulse events. Thresholds do not control this alarm.
+ pub fn spo2_status(&self, pulse_rate: Option<i32>) -> Spo2Status {
+ if !self.spo2_sensor_attached {
+ Spo2Status::NoSensor
+ } else if self.spo2_quality == Spo2Quality::None || pulse_rate.is_none()
+ || !self.ecg_rhythm.can_generate_pulse()
+ || self.pulse_conduction == PulseConduction::None
+ || self.heart_rate <= 0
+ {
+ Spo2Status::NoReading
+ } else {
+ Spo2Status::Available
+ }
+ }
+}
+
impl Default for Parameters {
fn default() -> Self {
Self {
@@ -308,6 +351,41 @@ mod tests {
assert!(!p.alarms.pr.enabled());
}
+ #[test]
+ fn vt_stays_perfusing_and_pvt_is_electrically_organized_but_pulseless() {
+ use EcgRhythm::*;
+ assert!(VentricularTachycardia.has_qrs());
+ assert!(VentricularTachycardia.can_generate_pulse());
+ assert!(PulselessVentricularTachycardia.has_qrs());
+ assert!(!PulselessVentricularTachycardia.can_generate_pulse());
+ assert!(!VentricularFibrillation.can_generate_pulse());
+ assert!(!Asystole.can_generate_pulse());
+ for rhythm in [VentricularTachycardia, PulselessVentricularTachycardia, VentricularFibrillation] {
+ assert_eq!(rhythm.rhythm_alarm(), Some("ARRHYTHMIA"));
+ }
+ assert_eq!(Asystole.rhythm_alarm(), Some("ASYSTOLE"));
+ assert_eq!(Sinus.rhythm_alarm(), None);
+ assert_eq!(AtrialFibrillation.rhythm_alarm(), None);
+ }
+
+ #[test]
+ fn sensor_and_no_reading_alarms_override_spo2_thresholds() {
+ let mut p = Parameters::default();
+ assert_eq!(p.spo2_status(Some(80)), Spo2Status::Available);
+ assert_eq!(p.spo2_status(None), Spo2Status::NoReading);
+ p.spo2_quality = Spo2Quality::None;
+ assert_eq!(p.spo2_status(Some(80)), Spo2Status::NoReading);
+ p.spo2_sensor_attached = false;
+ assert_eq!(p.spo2_status(Some(80)), Spo2Status::NoSensor);
+ p.spo2_sensor_attached = true;
+ p.spo2_quality = Spo2Quality::Good;
+ p.ecg_rhythm = EcgRhythm::PulselessVentricularTachycardia;
+ assert_eq!(p.spo2_status(Some(80)), Spo2Status::NoReading);
+ p.ecg_rhythm = EcgRhythm::Sinus;
+ p.pulse_conduction = PulseConduction::None;
+ assert_eq!(p.spo2_status(Some(80)), Spo2Status::NoReading);
+ }
+
#[test]
fn grouped_mechanical_capture_follows_requested_patterns() {
assert_eq!((1..=8).filter(|&b| PulseConduction::TwoToOne.conducts(b)).collect::<Vec<_>>(),
diff --git a/src/render.rs b/src/render.rs
index 8391fe8..c0f8474 100644
--- a/src/render.rs
+++ b/src/render.rs
@@ -1,7 +1,7 @@
//! Size-independent Cairo drawing of the synthetic bedside monitor.
use gtk::cairo::{Context, FontSlant, FontWeight, LineCap, LineJoin};
-use crate::model::{mean_arterial_pressure, AlarmLimits, AlarmState, EcgRhythm, Parameters, PulseConduction, Spo2Quality};
+use crate::model::{mean_arterial_pressure, AlarmLimits, AlarmState, Parameters, PulseConduction, Spo2Quality, Spo2Status};
use crate::simulation::{Sample, Simulator};
type Color = (f64, f64, f64);
@@ -106,17 +106,17 @@ fn pleth_trace_enabled(p: &Parameters) -> bool {
}
fn spo2_vitals(p: &Parameters, pulse_rate: Option<i32>) -> (String, String, String) {
- if !p.spo2_sensor_attached {
- return ("SpO₂".to_owned(), "NO SENSOR".to_owned(), "SpO₂ -- PR -- bpm".to_owned());
+ match p.spo2_status(pulse_rate) {
+ Spo2Status::NoSensor => (
+ "SpO₂".to_owned(), "NO SENSOR".to_owned(), "PR -- bpm".to_owned()),
+ Spo2Status::NoReading => (
+ "SpO₂".to_owned(), "NO READING".to_owned(), "PR -- bpm".to_owned()),
+ Spo2Status::Available => (
+ format!("SpO₂ {}", p.spo2_quality.stars()),
+ p.spo2.to_string(),
+ format!("% PR {} bpm", pulse_rate.unwrap_or_default()),
+ ),
}
- if p.spo2_quality == Spo2Quality::None {
- return ("SpO₂".to_owned(), "--".to_owned(), "NO SIGNAL PR -- bpm".to_owned());
- }
- (
- format!("SpO₂ {}", p.spo2_quality.stars()),
- if pulse_rate.is_some() { p.spo2.to_string() } else { "--".to_owned() },
- format!("% PR {} bpm", pulse_rate.map_or("--".to_owned(), |pr| pr.to_string())),
- )
}
fn alarmed(limits: AlarmLimits, value: Option<i32>) -> bool {
@@ -136,16 +136,15 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64,
let number_size = (row_h * 0.375).min(width * 0.26).clamp(16.0, 59.0);
let sub_size = (row_h * 0.16).clamp(11.0, 22.0) * 0.85;
let flash = alarm_flash_on(sim);
- let has_capture = p.ecg_rhythm.has_qrs()
+ let has_capture = p.ecg_rhythm.can_generate_pulse()
&& p.heart_rate > 0
&& p.pulse_conduction != PulseConduction::None;
let pulse_rate = if has_capture { sim.pulse_rate() } else { None };
let ecg_hr = if p.ecg_rhythm.has_qrs() && p.heart_rate > 0 {
Some(p.heart_rate)
} else { None };
- let oxygen = if pleth_trace_enabled(p) && pulse_rate.is_some() {
- Some(p.spo2)
- } else { None };
+ let spo2_status = p.spo2_status(pulse_rate);
+ let oxygen = if spo2_status == Spo2Status::Available { Some(p.spo2) } else { None };
let art_map = mean_arterial_pressure(p.art_systolic, p.art_diastolic);
let limits: Vec<(&str, AlarmLimits)> = match ch {
@@ -165,23 +164,23 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64,
draw_alarm_number(cr, &ecg_hr.map_or("--".to_owned(), |v| v.to_string()),
x, value_y, number_size, width, color,
alarmed(p.alarms.hr, ecg_hr), flash);
- let rhythm = match p.ecg_rhythm {
- EcgRhythm::Sinus => "Sinus",
- EcgRhythm::AtrialFibrillation => "AF",
- EcgRhythm::VentricularTachycardia => "VT",
- EcgRhythm::VentricularFibrillation => "VF",
- EcgRhythm::Asystole => "Asystole",
- };
- text(cr, &format!("bpm · {}", rhythm), x, info_y, sub_size, color, false);
+ // Show only the clinical alarm message, never the selected ECG rhythm.
+ if let Some(message) = p.ecg_rhythm.rhythm_alarm() {
+ draw_alarm_number(cr, message, x, info_y, sub_size * 1.1,
+ width, color, true, flash);
+ } else {
+ text(cr, "bpm", x, info_y, sub_size, color, false);
+ }
}
Channel::Pleth => {
let (label, value, info) = spo2_vitals(p, pulse_rate);
text(cr, &label, x, top + row_h * 0.24, label_size, color, false);
- let value_size = if value == "NO SENSOR" {
- number_size.min(0.19 * width).min(26.0)
+ let technical_alarm = spo2_status != Spo2Status::Available;
+ let value_size = if technical_alarm {
+ number_size.min(0.17 * width).min(26.0)
} else { number_size };
draw_alarm_number(cr, &value, x, value_y, value_size,
- width, color, alarmed(p.alarms.spo2, oxygen), flash);
+ width, color, technical_alarm || alarmed(p.alarms.spo2, oxygen), flash);
if oxygen.is_some() {
draw_alarm_inline(cr, x, info_y, sub_size, width, color,
"% PR ", &pulse_rate.unwrap_or_default().to_string(), " bpm",
@@ -377,7 +376,9 @@ fn draw_trace(cr: &Context, channel: Channel, color: Color,
}
// Disconnected or absent pleth signal: no curve, including historical pulses.
- if matches!(channel, Channel::Pleth) && !pleth_trace_enabled(p)
+ if matches!(channel, Channel::Pleth)
+ && (!pleth_trace_enabled(p)
+ || p.spo2_status(sim.pulse_rate()) != Spo2Status::Available)
{
let _ = cr.restore();
return;
@@ -544,8 +545,7 @@ mod tests {
p.spo2_sensor_attached = true;
p.spo2_quality = Spo2Quality::None;
assert!(!pleth_trace_enabled(&p));
- assert_eq!(spo2_vitals(&p, Some(75)).1, "--");
- assert!(spo2_vitals(&p, Some(75)).2.contains("NO SIGNAL"));
+ assert_eq!(spo2_vitals(&p, Some(75)).1, "NO READING");
assert!(spo2_vitals(&p, Some(75)).2.contains("PR --"));
assert!(p.show_spo2); // no readings, but visible row and status
}
@@ -559,10 +559,20 @@ mod tests {
assert!(spo2_vitals(&p, Some(75)).2.contains("PR 75 bpm"));
p.spo2_quality = Spo2Quality::Good;
assert_eq!(spo2_vitals(&p, Some(75)).0, "SpO₂ ★★★");
- assert_eq!(spo2_vitals(&p, None).1, "--");
+ assert_eq!(spo2_vitals(&p, None).1, "NO READING");
assert!(spo2_vitals(&p, None).2.contains("PR --"));
}
+ #[test]
+ fn no_sensor_precedes_no_reading_and_both_are_spo2_alarms() {
+ let mut p = Parameters::default();
+ assert_eq!(spo2_vitals(&p, None).1, "NO READING");
+ p.ecg_rhythm = crate::model::EcgRhythm::PulselessVentricularTachycardia;
+ assert_eq!(spo2_vitals(&p, Some(100)).1, "NO READING");
+ p.spo2_sensor_attached = false;
+ assert_eq!(spo2_vitals(&p, Some(100)).1, "NO SENSOR");
+ }
+
#[test]
fn arterial_axis_is_absolute_and_fixed_to_200_mmhg() {
let p = Parameters::default();
diff --git a/src/simulation.rs b/src/simulation.rs
index f3d7b01..a9f5c7b 100644
--- a/src/simulation.rs
+++ b/src/simulation.rs
@@ -109,7 +109,7 @@ impl Simulator {
if params.ecg_rhythm != self.previous_rhythm
|| params.pulse_conduction != self.previous_conduction
- || !params.ecg_rhythm.has_qrs()
+ || !params.ecg_rhythm.can_generate_pulse()
|| params.pulse_conduction == PulseConduction::None
|| params.heart_rate <= 0
{
@@ -146,7 +146,8 @@ impl Simulator {
// Interpolate within the 4 ms sample so mechanical onsets stay aligned.
let qrs_time = self.time - SAMPLE_STEP * (next_phase - QRS_PHASE) / increment;
self.ecg_beat_number += 1;
- if params.pulse_conduction.conducts(self.ecg_beat_number) {
+ if params.ecg_rhythm.can_generate_pulse()
+ && params.pulse_conduction.conducts(self.ecg_beat_number) {
let pulse_pressure_scale = if params.respiratory_rate > 0 {
ppv_multiplier(params.pulse_pressure_variation, self.respiratory_phase)
} else {
@@ -208,7 +209,14 @@ impl Simulator {
}
}
- let art = if let Some(age) = latest_art_age {
+ let art = if !params.ecg_rhythm.can_generate_pulse()
+ || params.pulse_conduction == PulseConduction::None
+ || params.heart_rate <= 0
+ {
+ // Low-frequency baseline drift around zero, without pulsations.
+ // The smooth, deterministic noise stays within 0..5 mmHg.
+ pulseless_arterial_drift(self.time)
+ } else if let Some(age) = latest_art_age {
// Pressure decays after an unperfused interval instead of showing a
// non-existent 75 mmHg baseline during prolonged missed captures.
let baseline = diastolic * (-(age - 0.60).max(0.0) / 1.40).exp();
@@ -220,6 +228,28 @@ impl Simulator {
}
}
+/// Deterministic smooth value noise with a slow, non-cardiac frequency.
+fn smooth_random_unit(time: f64, seconds_per_step: f64, seed: i64) -> f64 {
+ fn hash(index: i64) -> f64 {
+ let mut x = (index as u64).wrapping_add(0x9E37_79B9_7F4A_7C15);
+ x = (x ^ (x >> 30)).wrapping_mul(0xBF58_476D_1CE4_E5B9);
+ x = (x ^ (x >> 27)).wrapping_mul(0x94D0_49BB_1331_11EB);
+ x ^= x >> 31;
+ (x as f64) / (u64::MAX as f64)
+ }
+ let position = time / seconds_per_step;
+ let index = position.floor() as i64;
+ let delta = position - index as f64;
+ let fade = delta * delta * (3.0 - 2.0 * delta);
+ hash(index.wrapping_add(seed)) * (1.0 - fade)
+ + hash(index.wrapping_add(seed).wrapping_add(1)) * fade
+}
+
+fn pulseless_arterial_drift(time: f64) -> f64 {
+ (0.4 + 3.6 * smooth_random_unit(time, 2.4, 12)
+ + 0.65 * smooth_random_unit(time, 0.95, 41)).clamp(0.0, 5.0)
+}
+
fn gaussian(x: f64, center: f64, width: f64) -> f64 {
let d = (x - center) / width;
(-0.5 * d * d).exp()
@@ -281,7 +311,7 @@ fn ecg_amplitude(phase: f64, time: f64, rhythm: EcgRhythm, heart_rate: i32) -> f
- 0.32 * lobe(0.028, 0.012)
+ 0.28 * lobe(t_after_qrs, t_width)
}
- EcgRhythm::VentricularTachycardia => {
+ EcgRhythm::VentricularTachycardia | EcgRhythm::PulselessVentricularTachycardia => {
// Broad monomorphic ventricular complexes, also in milliseconds.
1.06 * lobe(0.0, 0.045)
- 0.49 * lobe(0.068, 0.030)
@@ -389,13 +419,14 @@ mod tests {
for (rhythm, capture) in [
(EcgRhythm::Asystole, PulseConduction::OneToOne),
(EcgRhythm::VentricularFibrillation, PulseConduction::OneToOne),
+ (EcgRhythm::PulselessVentricularTachycardia, PulseConduction::OneToOne),
(EcgRhythm::Sinus, PulseConduction::None),
] {
let p = Parameters { ecg_rhythm: rhythm, pulse_conduction: capture, ..Parameters::default() };
let mut sim = Simulator::new(&p);
for _ in 0..250 { sim.step(&p); }
assert!(sim.pulse_rate().is_none());
- assert!(sim.samples.iter().all(|s| s.art == 0.0 && s.pleth == 0.0));
+ assert!(sim.samples.iter().all(|s| (0.0..=5.0).contains(&s.art) && s.pleth == 0.0));
}
}
@@ -407,10 +438,44 @@ mod tests {
p.pulse_conduction = PulseConduction::None;
sim.step(&p);
assert!(sim.pulse_rate().is_none());
- assert_eq!(sim.samples.back().unwrap().art, 0.0);
+ assert!((0.0..=5.0).contains(&sim.samples.back().unwrap().art));
assert_eq!(sim.samples.back().unwrap().pleth, 0.0);
}
+ #[test]
+ fn vt_remains_perfusing_and_pvt_has_qrs_but_no_pulse() {
+ let mut p = Parameters {
+ ecg_rhythm: EcgRhythm::VentricularTachycardia,
+ heart_rate: 160,
+ ..Parameters::default()
+ };
+ let mut sim = Simulator::new(&p);
+ assert_eq!(sim.pulse_rate(), Some(160));
+ assert!(sim.samples().iter().any(|s| s.art > 70.0 && s.pleth > 0.0));
+ p.ecg_rhythm = EcgRhythm::PulselessVentricularTachycardia;
+ sim.step(&p);
+ assert_eq!(sim.pulse_rate(), None);
+ assert!((0.0..=5.0).contains(&sim.samples().back().unwrap().art));
+ assert_eq!(sim.samples().back().unwrap().pleth, 0.0);
+ for _ in 0..500 { sim.step(&p); }
+ assert!(sim.samples().iter().rev().take(500)
+ .all(|s| (0.0..=5.0).contains(&s.art) && s.pleth == 0.0));
+ assert!(sim.samples().iter().rev().take(500)
+ .any(|s| s.ecg.abs() > 0.3));
+ }
+
+ #[test]
+ fn low_pressure_drift_is_smooth_and_never_pulsatile() {
+ let values: Vec<f64> = (0..5000)
+ .map(|n| pulseless_arterial_drift(n as f64 * SAMPLE_STEP))
+ .collect();
+ assert!(values.iter().all(|v| (0.0..=5.0).contains(v)));
+ assert!(values.windows(2).all(|w| (w[1] - w[0]).abs() < 0.10));
+ let spread = values.iter().copied().fold(f64::NEG_INFINITY, f64::max)
+ - values.iter().copied().fold(f64::INFINITY, f64::min);
+ assert!(spread > 0.25);
+ }
+
#[test]
fn pulse_rate_follows_two_to_one_capture() {
let p = Parameters { pulse_conduction: PulseConduction::TwoToOne, ..Parameters::default() };
diff --git a/src/ui.rs b/src/ui.rs
index a36fec3..669c227 100644
--- a/src/ui.rs
+++ b/src/ui.rs
@@ -146,14 +146,15 @@ fn create_admin(app: &Application, params: SharedParams,
let ecg = group(&controls, "ECG");
add_visibility(&ecg, params.borrow().show_ecg, params.clone(), |p, show| p.show_ecg = show);
add_dropdown(&ecg, "ECG rhythm", &[
- "Sinus rhythm", "Atrial fibrillation", "Ventricular tachycardia",
- "Ventricular fibrillation", "Asystole",
+ "Sinus rhythm", "Atrial fibrillation", "Ventricular tachycardia (VT)",
+ "Pulseless ventricular tachycardia (PVT)", "Ventricular fibrillation", "Asystole",
], params.clone(), |p, selected| {
p.ecg_rhythm = match selected {
1 => EcgRhythm::AtrialFibrillation,
2 => EcgRhythm::VentricularTachycardia,
- 3 => EcgRhythm::VentricularFibrillation,
- 4 => EcgRhythm::Asystole,
+ 3 => EcgRhythm::PulselessVentricularTachycardia,
+ 4 => EcgRhythm::VentricularFibrillation,
+ 5 => EcgRhythm::Asystole,
_ => EcgRhythm::Sinus,
};
});
@@ -210,7 +211,7 @@ fn create_admin(app: &Application, params: SharedParams,
});
let conduction_hint = gtk::Label::new(Some(
"Pulse rate is derived from captured QRS events.
-ART and pleth are delayed; VF and asystole always have no pulse."
+ART and pleth are delayed. VT can be perfusing; PVT, VF and asystole are pulseless."
));
conduction_hint.set_xalign(0.0);
conduction_hint.set_wrap(true);