SimPaM/patient-monitor-simulation-v0.4.4-to-v0.5.0.patch

1526 lines
79 KiB
Diff
Raw Normal View History

2026-11-12 14:07:59 +01:00
diff --git a/Cargo.toml b/Cargo.toml
index b9aa888..6ee2389 100644
--- a/Cargo.toml
+++ b/Cargo.toml
@@ -1,6 +1,6 @@
[package]
name = "patient-monitor-simulation"
-version = "0.4.4"
+version = "0.5.0"
edition = "2021"
license = "MIT"
description = "Synthetic patient-monitor simulation for teaching (not for clinical use)"
diff --git a/README.de.md b/README.de.md
new file mode 100644
index 0000000..3c43a45
--- /dev/null
+++ b/README.de.md
@@ -0,0 +1,369 @@
+# Patient Monitor Simulation (PaMSim) — v0.5.0
+
+Ein mit Rust und GTK4 entwickelter Patient*innenmonitor-Simulator mit zwei Fenstern für die Lehre unter Fedora Linux.
+
+> **Ausschließlich synthetische Trainingssignale — nicht für die klinische Anwendung.**
+> EKG, invasive arterielle Druckkurve, Plethysmogramm und Kapnogramm sind schematische mathematische Annäherungen.
+> Die Simulation wurde nicht klinisch validiert und ist kein Medizinprodukt.
+
+## Installation, Kompilierung und Start unter Fedora
+
+```bash
+sudo dnf install rust cargo gcc pkgconf-pkg-config gtk4-devel
+cargo test
+cargo run --release
+```
+
+Die Befehle sind im entpackten Verzeichnis `patient-monitor-simulation` auszuführen.
+Die Fenstertitel zeigen die Anwendungsversion an.
+GTK4 benötigt eine funktionsfähige grafische Sitzung, beispielsweise Fedora KDE unter Wayland.
+
+## Fenster
+
+**Admin-Bereiche:** Links neben jeder Parametergruppe befindet sich ein schmaler Farbstreifen, dessen Farbe der jeweiligen Darstellung am Monitor entspricht: EKG **grün**, SpO₂ **gelb**, invasiver arterieller Blutdruck **rot**, Kapnographie **hellgrau** und NIBP **rot**.
+Der Bereich für Patientendaten bleibt neutral.
+Die Farbstreifen werden von GTK dargestellt und sind unabhängig vom hellen bzw. dunklen Design sichtbar.
+Die Änderung betrifft ausschließlich die Darstellung; die Funktion der Bedienelemente bleibt unverändert.
+
+**Admin-Fenster:** Hier werden Patientenname, EKG-Rhythmus und Herzfrequenz, mechanische Pulsübertragung, SpO₂, Signalqualität und Sensoranschluss, invasiver arterieller Blutdruck, Kurvenform und Pulsdruckvariation, NIBP sowie Kapnographie eingestellt.
+Numerische Eingabefelder und Schieberegler sind bidirektional gekoppelt: Änderungen am einen Bedienelement werden unmittelbar im anderen übernommen.
+Jeder der fünf Monitorbereiche (EKG, SpO₂/Plethysmographie, ART, CO₂, NIBP) verfügt über ein eigenes Kontrollkästchen **Show on monitor**.
+
+**Monitorfenster:** Schwarzer Hintergrund mit grünem EKG, gelbem Plethysmogramm, roter arterieller Druckkurve und hellgrauem Kapnogramm.
+Der im Admin-Fenster eingegebene Patientenname ersetzt sofort die Überschrift **PATIENT MONITOR**.
+Bei leerem Namensfeld wird wieder die allgemeine Überschrift angezeigt.
+Lange Namen werden an die verfügbare Breite angepasst oder abgeschnitten.
+Wird die Sichtbarkeit eines Parameters deaktiviert, verschwinden sowohl seine Kurve als auch die zugehörigen Messwerte.
+Die verbleibenden Kurvenbereiche vergrößern sich entsprechend.
+Das Ausblenden eines Monitorbereichs unterbricht **nicht** die Signalerzeugung oder physiologische Kopplung: Wird beispielsweise das EKG ausgeblendet, können arterielle und plethysmographische Pulse weiterhin auftreten.
+NIBP kann unabhängig ausgeblendet werden; dabei verschwindet auch das separate rote Wertefeld in der rechten Monitorspalte.
+
+Das Monitorfenster lässt sich in der Größe verändern.
+Mit **F11** wird der Vollbildmodus aktiviert bzw. umgeschaltet, mit **Esc** wird er verlassen.
+Unter Wayland sollte das Fenster vor dem Wechsel in den Vollbildmodus auf den gewünschten Präsentationsbildschirm verschoben werden.
+Der Vollbildmodus sperrt den Computer nicht gegen andere Eingaben.
+
+## Numerische Alarmgrenzen (seit v0.4.0; Anordnung und Voreinstellungen seit v0.4.1)
+
+Für jeden angezeigten numerischen Messwert können im zugehörigen Admin-Bereich **unabhängige optionale untere (↓) und obere (↑) Alarmgrenzen** festgelegt werden.
+Die Eingabefelder für die Grenzwerte befinden sich **in derselben Zeile wie der entsprechende Schieberegler**.
+Abgeleitete Werte ohne eigenen Schieberegler (PR, ART-MAP, NIBP-MAP) haben kompakte separate Alarmzeilen.
+Das Admin-Fenster ist für diese zusätzlichen Bedienelemente breiter ausgelegt.
+
+Die Grenzwerte werden als Text eingegeben.
+Ein **leeres Feld** (angezeigt als `off`) deaktiviert nur die betreffende Grenze.
+Sind beide Felder leer, ist der numerische Alarm für diesen Messwert vollständig deaktiviert.
+Ein Messwert, der genau auf einer Grenze liegt, löst keinen Alarm aus; nur Werte **unterhalb** der unteren bzw. **oberhalb** der oberen Grenze gelten als außerhalb des erlaubten Bereichs.
+Sind beide Grenzen eingetragen, darf die untere Grenze die obere nicht überschreiten.
+Ungültige Eingaben werden hervorgehoben; die letzte gültige Einstellung bleibt wirksam.
+
+| Monitorbereich | Unabhängig einstellbare Alarmgrenzen |
+| --- | --- |
+| EKG | Herzfrequenz (HR) |
+| SpO₂ | Sauerstoffsättigung (SpO₂), abgeleitete Pulsfrequenz (PR) |
+| Invasiver arterieller Blutdruck (ART) | Systolischer (SYS), mittlerer (MAP), diastolischer Druck (DIA), PPV |
+| NIBP | Systolischer (SYS), mittlerer (MAP), diastolischer Druck (DIA) |
+| Kapnographie | Endtidales CO₂ (EtCO₂), Atemfrequenz (RR) |
+
+Die aktuell eingestellten Grenzwerte erscheinen in kleiner Schrift **rechts oben** im jeweiligen Monitorbereich.
+Pfeile kennzeichnen die Richtung der Grenze.
+Eine deaktivierte Grenze wird als `---` dargestellt, beispielsweise:
+
+```text
+⚠ SYS ↓80 ↑180
+ MAP ↓60 ↑---
+ DIA ↓--- ↑---
+```
+
+### Alarmvoreinstellungen (Alert presets)
+
+Das Auswahlmenü **Alert presets** oben im Admin-Fenster bietet die Einträge **Custom** (manuelle Einstellung) und **Adult** (Erwachsene).
+Die Auswahl **Adult** übernimmt sofort alle zugehörigen Alarmgrenzen und aktualisiert die Eingabefelder neben den Schiebereglern.
+**Nur die Alarmgrenzen ändern sich**: Herzfrequenz, Blutdruck, Sichtbarkeit der Monitorbereiche und andere simulierte physiologische Parameter bleiben unverändert.
+Wird nach Auswahl von Adult eine Alarmgrenze manuell verändert, wechselt das Menü automatisch zu **Custom**, ohne die übrigen Grenzen zu verändern.
+Durch erneute Auswahl von **Adult** wird die vollständige Voreinstellung wiederhergestellt.
+
+| Parameter | Untere Grenze | Obere Grenze |
+| --- | ---: | ---: |
+| HR (bpm) | 60 | 100 |
+| SpO₂ (%) | 90 | --- |
+| PR (bpm) | --- | --- |
+| ART SYS (mmHg) | 80 | 180 |
+| ART MAP (mmHg) | 60 | 100 |
+| ART DIA (mmHg) | --- | --- |
+| PPV (%) | --- | 10 |
+| NIBP SYS (mmHg) | 80 | 180 |
+| NIBP MAP (mmHg) | 60 | 100 |
+| NIBP DIA (mmHg) | --- | --- |
+| EtCO₂ (mmHg) | 30 | 50 |
+| RR (/min) | 10 | 20 |
+
+`---` bedeutet, dass die jeweilige Alarmgrenze deaktiviert ist.
+Die Voreinstellung Adult dient **ausschließlich der Lehre** und stellt keine klinisch validierte Grenzwertkonfiguration dar.
+Beim Programmstart ist **Custom** ausgewählt; sämtliche Grenzen sind zunächst deaktiviert (wie in v0.4.0).
+
+Verletzt ein Messwert eine aktivierte Alarmgrenze, **blinkt ausschließlich der betroffene Zahlenwert durch abwechselnde Invertierung von Vorder- und Hintergrundfarbe** (500 ms invertiert / 500 ms normal).
+SYS, DIA, MAP und die PPV-Anzeige blinken jeweils unabhängig voneinander.
+Die Kurve selbst bleibt unverändert.
+Standardmäßig sind alle numerischen Alarme deaktiviert, damit bestehende Unterrichtsszenarien nicht unerwartet blinken.
+
+Numerische Grenzwertalarme werden nur für tatsächlich verfügbare Messwerte ausgewertet.
+`--`, `NO SENSOR` und andere nicht verfügbare Anzeigen lösen keine numerischen Untergrenzenalarme aus.
+Die aus dem EKG abgeleitete Pulsfrequenz und die Sichtbarkeit der Signale funktionieren weiterhin wie in v0.3.2.
+Alarme sind derzeit rein visuell: Es gibt **keine akustischen Alarme, Alarmspeicherung bis zur Quittierung, Prioritätsklassifizierung oder klinische Alarmvalidierung**.
+Die Einstellungen bleiben nur während der laufenden Programmsitzung erhalten und werden beim Neustart zurückgesetzt.
+
+## Patientenname und Signalstatus des Pulsoxymeters (seit v0.3.2)
+
+Das Feld **Patient name** oben im Admin-Fenster ersetzt die Monitorüberschrift unmittelbar durch den eingegebenen Namen.
+Das Feld ist optional; bei leerer oder ausschließlich aus Leerzeichen bestehender Eingabe erscheint **PATIENT MONITOR**.
+Der Name dient nur zur Kennzeichnung des Unterrichtsszenarios; es handelt sich nicht um eine Patientenakte.
+
+Unter Admin → **Pulse oximetry** stehen zwei zusätzliche Einstellungen zur Verfügung:
+
+- **Sensor not attached** (Kontrollkästchen): Entfernt unmittelbar das Plethysmogramm, unterdrückt SpO₂- und Pulsfrequenzwerte und zeigt **NO SENSOR** anstelle der numerischen Sättigung.
+ Dieser Zustand hat Vorrang vor der eingestellten Signalqualität.
+- **Signal quality** (Auswahlmenü): Verändert die sichtbare Plethysmogrammform und den Qualitätsindikator unabhängig vom eingestellten SpO₂-Prozentwert.
+
+| Einstellung | Plethysmogramm | Monitoranzeige |
+| --- | --- | --- |
+| **0 — None** | Keine Kurve | Blinkendes **NO READING**, PR `--`; keine Sterne |
+| **1 — Poor** | Kleine, unregelmäßig verzerrte Pulse mit zeitweiligen Signalausfällen | 1 Stern (★), solange ein Signal vorhanden ist; blinkendes **NO READING** während des Ausfalls |
+| **2 — Adequate** | Mittlere Amplitude, geglättete und gedämpfte Pulse | 2 Sterne (★★) |
+| **3 — Good** | Volle nominelle Amplitude, geglättete und gedämpfte Pulse | 3 Sterne (★★★) |
+
+Standardeinstellung: Sensor angeschlossen und Signalqualität **3 — Good**.
+Bei den Qualitätsstufen 1–3 wird der eingestellte SpO₂-Wert nur angezeigt, wenn mechanische Pulse erkannt werden.
+
+Bei **Poor** treten zusätzlich wiederholte vollständige Signalausfälle auf: Zwischen den Unterbrechungen liegen **30–180 Sekunden** mit verwertbarem, aber qualitativ schlechtem Signal; jede Unterbrechung dauert **5–20 Sekunden**.
+Während eines Ausfalls verschwindet die Plethysmogrammkurve, SpO₂ und PR sind nicht verfügbar und **NO READING** blinkt.
+Nach Ende des Ausfalls kehren das Poor-Signal und die numerischen Werte automatisch zurück.
+Die Intervalle werden pseudozufällig anhand der Simulationszeit bestimmt und sind unabhängig von der Bildwiederholrate.
+Beim erneuten Auswählen von Poor beginnt die Intervallfolge von vorn.
+
+Ein Signalausfall beeinflusst weder die eingestellte Sauerstoffsättigung noch das EKG, die Erzeugung mechanischer Pulse oder die arterielle Druckkurve.
+Die simulierte Pulsfrequenz wird weiterhin aus mechanisch wirksamen QRS-Komplexen abgeleitet.
+Das gestörte Plethysmogramm verwendet deterministisches, weich interpoliertes Pseudorauschen, das ausschließlich bereits vorhandene Pulse moduliert.
+Es erzeugt daher keine künstlichen Pulse bei PEA, PVT, Kammerflimmern oder Asystolie.
+Bei abgezogenem Sensor oder Signalqualität 0 werden auch zuvor gepufferte Plethysmogrammwerte sofort ausgeblendet.
+EKG und ART bleiben unbeeinflusst.
+Das Kontrollkästchen **Show on monitor** blendet weiterhin den vollständigen SpO₂-Monitorbereich aus; Sensor- und Qualitätszustände lassen den Bereich dagegen sichtbar, damit die Statusmeldungen im Unterricht demonstriert werden können.
+
+## EKG und mechanische Pulskopplung
+
+- **EKG-Rhythmen:** Sinusrhythmus, Vorhofflimmern, monomorphe ventrikuläre Tachykardie (VT; potenziell mit mechanischer Perfusion), pulslose ventrikuläre Tachykardie (PVT), Kammerflimmern (VF) und Asystolie.
+- **Mechanische Pulsübertragung:** **1:1**, **2:1**, **3:1**, **None (PEA)** oder deterministisch pseudozufällige Übertragung (ca. 65 %).
+ Die Pulsfrequenz (PR) wird aus mechanisch wirksamen QRS-Ereignissen abgeleitet; ein eigener Pulsfrequenz-Schieberegler existiert nicht.
+- Ein mechanisch wirksamer QRS-Komplex löst nach modellhaften **120 ms** einen arteriellen Druckanstieg und nach **300 ms** einen peripheren Plethysmogrammpuls aus.
+ Das Plethysmogramm wird stark gedämpft und gefiltert dargestellt.
+- Bei Auswahl von VT oder PVT wird die Herzfrequenz zunächst auf **160 bpm** gesetzt und sowohl im Schieberegler als auch im numerischen Feld aktualisiert.
+ Eine anschließende manuelle Änderung ist möglich.
+- PVT, VF, Asystolie und PEA unterdrücken mechanische Pulse.
+ Die ART-Kurve schwankt dann langsam zwischen **0 und 5 mmHg**, statt pulsatile Drücke darzustellen.
+ Der ART-**SYS**-Wert zeigt den gerundeten niedrigen Transducerdruck (0–5 mmHg).
+ DIA und MAP zeigen `--`, weil sie nicht zuverlässig bestimmt werden können.
+ Frühere Druckwerte laufen mit dem Signalverlauf aus dem Sichtfenster.
+ NIBP folgt einem separaten simulierten Manschettenmesszyklus.
+
+## Invasiver arterieller Blutdruck und PPV (seit v0.3)
+
+Die arterielle Druckkurve hat eine feste Skala von **0–200 mmHg** mit Markierungen bei **0, 50, 100, 150 und 200 mmHg**.
+Die eingestellten nominellen systolischen und diastolischen ART-Werte sind auf 0–200 mmHg begrenzt.
+
+Die **Pulsdruckvariation (PPV)** ist im Bereich **0–60 %** in Schritten von 1 % über einen gekoppelten Schieberegler und ein Textfeld einstellbar (Admin → Invasive arterial blood pressure).
+Standardwert ist **0 %**, also keine respiratorische Modulation.
+Der Atemzyklus wird aus demselben Atemfrequenzparameter wie das Kapnogramm erzeugt.
+**RR = 0** deaktiviert die respiratorische Modulation (Apnoe).
+
+Die synthetische PPV-Definition lautet:
+
+```text
+PPV (%) = 100 × (PPmax − PPmin) / ((PPmax + PPmin) / 2)
+```
+
+Das Modell moduliert den **Pulsdruck** sinusförmig; die Modulation wird für jeden mechanisch wirksamen Herzschlag gesondert bestimmt.
+Der diastolische Ausgangsdruck bleibt nominell konstant.
+Es entsteht somit vor allem eine **atemabhängige systolische Schwankung von Schlag zu Schlag** und keine beliebige vertikale Verschiebung der gesamten Druckkurve.
+Die Modulation beeinflusst weder das EKG noch die mechanische Pulsübertragung oder die Amplitude des Plethysmogramms.
+Es handelt sich um ein Anschauungsmodell und nicht um ein validiertes Verfahren zur Vorhersage der Volumenreagibilität.
+
+**Beispiel:** Ein arterieller Druck von 120/75 mmHg entspricht einem nominellen Pulsdruck von 45 mmHg.
+Bei einer PPV von 20 % liegen die idealisierten Pulsdruckextrema bei 40,5 und 49,5 mmHg.
+Bei unverändertem diastolischem Druck von 75 mmHg ergeben sich systolische Spitzen von etwa 115,5 bis 124,5 mmHg.
+Aufgrund der Kurvenform und der endlichen Anzahl von Herzschlägen innerhalb eines Atemzyklus müssen die tatsächlich dargestellten Maxima die rechnerischen Extremwerte nicht exakt erreichen.
+
+Der ART-Anzeigebereich zeigt die **nominellen** systolischen und diastolischen Druckwerte sowie den MAP und bei PPV über 0 den **eingestellten** PPV-Wert.
+Die PPV wird nicht aus den abgetasteten Druckwerten berechnet.
+Bei sehr hohen nominellen systolischen Drücken können modulierte Spitzen die Grenze von 200 mmHg überschreiten.
+Die Kurve wird dann **am oberen Skalenende abgeschnitten**, ohne dass die Skala automatisch angepasst wird.
+
+## Anzeigeoptionen (seit v0.3)
+
+Die fünf Kontrollkästchen **Show on monitor** beeinflussen ausschließlich die Darstellung:
+
+| Kontrollkästchen | Ausgeblendete Monitorinhalte |
+| --- | --- |
+| ECG | EKG-Kurve, Herzfrequenz und ggf. Rhythmusalarm |
+| Pulse oximetry | Plethysmogramm, SpO₂ und PR |
+| Invasive arterial blood pressure | ART-Kurve, Druckwerte, MAP und PPV-Anzeige |
+| Capnography | CO₂-Kurve, EtCO₂ und Atemfrequenz |
+| NIBP | Zeitgesteuerte Manschettenmesswerte im roten Wertefeld der rechten Monitorspalte |
+
+Die verbleibenden Kurven behalten ihre Reihenfolge bei und teilen sich die verfügbare Höhe gleichmäßig.
+Auch eine Anzeige ohne sichtbare Kurvenbereiche wird unterstützt.
+
+## Korrektur der EKG-Morphologie (v0.3.1)
+
+In der früheren EKG-Simulation wurde die QRS-Breite als fester Anteil des RR-Intervalls definiert und mit 100 Hz abgetastet.
+Bei hohen Herzfrequenzen konnten schmale R-Zacken zwischen die Abtastpunkte fallen.
+Dadurch schwankte die dargestellte QRS-Amplitude von Schlag zu Schlag stark, obwohl ein regelmäßiger Sinusrhythmus vorlag.
+
+- Die Breiten der synthetischen P-, QRS- und T-Komponenten werden jetzt in **Millisekunden** und nicht als fixe Anteile des Herzzyklus definiert.
+ Lage und Breite von P- und T-Wellen passen sich dem RR-Intervall an, während die QRS-Dauer weitgehend konstant bleibt.
+- Die Abtastfrequenz wurde auf **250 Hz** (4-ms-Abstände) erhöht, um R-Zacken auch bei **189–240 bpm** zuverlässiger zu erfassen.
+- Die EKG-Morphologie ist unabhängig von der respiratorischen PPV-Einstellung.
+ Die Verzögerungen für arterielle und plethysmographische Pulse sowie die Optionen für die mechanische Pulsübertragung bleiben unverändert.
+- Regressionstests vergleichen die R-Zacken-Amplituden bei 60, 75, 120, 189 und 240 bpm und prüfen, dass Änderungen der PPV das EKG-Signal nicht beeinflussen.
+
+Das EKG bleibt ein schematisches Lehrsignal.
+Eine Spannungskalibrierung, ein Modell zur Elektrodenpositionierung, diagnostische Kriterien oder eine patientenspezifische Physiologie werden nicht simuliert.
+
+## Technische Signalimplementierung
+
+- Synthetische Signale mit **250 Hz** Abtastfrequenz, **10 Sekunden** gespeichertem Signalverlauf und **8 Sekunden** sichtbarer, fortlaufender Kurve.
+- Cairo zeichnet in eine GTK4-`DrawingArea`; die Anzeige skaliert mit der Fenstergröße.
+- Jeder mechanisch wirksame QRS-Komplex erhält beim Ereignis einen eigenen respiratorischen PPV-Multiplikator.
+ Dadurch bleibt die Amplitude des zugehörigen arteriellen Pulsschlags während des gesamten Schlags konsistent.
+- Änderungen der PPV beeinflussen weder den peripheren Plethysmogrammpuls noch die Anzahl mechanischer Pulse.
+- Klinisch exakte Physiologie, akustische bzw. weitergehende Alarmfunktionen, klinisch validierte NIBP-Algorithmen, Kalibrierung und präzise physiologische Signallaufzeiten sind nicht Bestandteil dieses Prototyps.
+
+## Projektstruktur
+
+```text
+src/
+ main.rs Einstiegspunkt der GTK-Anwendung
+ model.rs Parameter, Rhythmus-/Pulsübertragung, Anzeigeoptionen
+ simulation.rs QRS-gesteuerte mechanische Signale, PPV und Atemsimulation
+ render.rs Cairo-Monitordarstellung, dynamische Sichtbarkeit, feste ART-Skala
+ ui.rs Admin-Bedienelemente und Monitorfenster
+```
+
+## Änderungen seit v0.2.2
+
+1. Respiratorische PPV mit einstellbarem Bereich von 0–60 %, gekoppelt an den simulierten Atemzyklus und **pro arteriellem Pulsschlag** angewendet.
+2. Fünf unabhängige Schalter für die Sichtbarkeit, dynamische Aufteilung der Kurvenbereiche und unabhängiges Ausblenden des NIBP-Bereichs.
+3. ART-Skala von **0–250** auf **0–200 mmHg** reduziert und Eingabebereiche angepasst.
+4. Regressionstests für die PPV-Berechnung und ihre Auswirkungen auf ART, das Ausblenden des EKG bei weiterhin vorhandenen mechanischen Pulsen, die Auswahl aktiver Monitorbereiche und die Normierung der arteriellen Druckskala ergänzt.
+
+**Überprüfung:** Das Archiv wurde aus diesen Quelldateien erstellt.
+Zur Überprüfung des Rust-/GTK-Builds bitte `cargo test` lokal ausführen.
+Rust und die GTK4-Entwicklungskomponenten waren in der Umgebung, in der das ZIP-Archiv erstellt wurde, nicht verfügbar.
+
+## Änderungen in v0.3.2
+
+1. Patientenname im Admin-Fenster ergänzt, der unmittelbar als Monitorüberschrift erscheint; bei leerem Feld wird die Standardüberschrift verwendet.
+2. Vier Stufen der SpO₂-Signalqualität mit Qualitätssternen und unregelmäßigem, amplitudenreduziertem Plethysmogramm für Poor ergänzt.
+3. **Sensor not attached** ergänzt: Anzeige `NO SENSOR` und Unterdrückung von SpO₂, PR und Plethysmogramm.
+4. Tests für die Skalierung der Signalqualität, die angezeigten Messwerte und das Verhalten bei nicht angeschlossenem Sensor ergänzt.
+
+**Build-Überprüfung:** ZIP-Integrität und Patch-Anwendung wurden überprüft.
+Die GTK4-Anwendung und die Rust-Tests wurden in der Paketierungsumgebung nicht kompiliert.
+Unter Fedora bitte `cargo test` und `cargo run --release` ausführen.
+
+## v0.4.2 — Rhythmusalarme, Sensoralarme und fehlende Messwerte
+
+- **VT** kann weiterhin mit mechanischer Perfusion einhergehen.
+ Der neue Rhythmus **PVT** (pulslose ventrikuläre Tachykardie) zeigt organisierte breite QRS-Komplexe, erzeugt jedoch keine arteriellen oder plethysmographischen Pulse.
+ Auch Kammerflimmern und Asystolie sind unabhängig von der gewählten Pulsübertragung pulslos.
+- **EKG:** Blinkende Meldung **ARRHYTHMIA** bei VT, PVT und VF; blinkende Meldung **ASYSTOLE** bei Asystolie.
+ Diese Ereignisalarme sind unabhängig von den numerischen Herzfrequenzgrenzen.
+- **SpO₂:** Bei abgezogenem Sensor ersetzt die blinkende Meldung **NO SENSOR** die Sauerstoffsättigung.
+ Signalqualität 0, Ausfall der mechanischen Pulsübertragung oder ein pulsloser Rhythmus führen zur blinkenden Meldung **NO READING** (ohne numerische SpO₂-/PR-Werte).
+ Ein abgezogener Sensor hat Vorrang.
+ In diesen Zuständen wird kein Plethysmogramm angezeigt.
+- **ART:** Ohne mechanische Pulse (einschließlich PVT, VF, Asystolie und PEA) zeigt die invasive Druckkurve langsame nichtpulsatile Schwankungen zwischen **0 und 5 mmHg**.
+ In v0.4.2 zeigte die numerische Anzeige `--/--`; seit v0.4.3 wird im SYS-Feld der gerundete gemessene Druck von 0–5 mmHg angezeigt, während DIA und MAP `--` zeigen.
+- Die **Bezeichnung des EKG-Rhythmus** wurde aus der Monitoranzeige entfernt.
+ Sichtbar sind nur Herzfrequenz und gegebenenfalls die zugehörige Alarmmeldung.
+ Der Rhythmus wird weiterhin im Admin-Fenster ausgewählt.
+- Die numerischen Alarmgrenzen und die Adult-Voreinstellung aus v0.4.1 bleiben unverändert.
+ Sämtliches Verhalten dient ausschließlich der Demonstration und ist nicht für klinische Entscheidungen geeignet.
+
+## v0.4.3 — Niedriger arterieller Druck, VT-Herzfrequenz und intermittierendes schlechtes SpO₂-Signal
+
+- Bei pulslosen Rhythmen, PEA oder sonstigem Ausfall mechanischer Pulse zeigt ART SYS den **aktuell gemessenen Druck von 0–5 mmHg** an, zum Beispiel `3/--` und `MAP -- mmHg`.
+ **Nur SYS** wird gegen die konfigurierten ART-SYS-Grenzen geprüft.
+ Aus fehlenden MAP- oder DIA-Werten werden keine irreführenden Grenzwertalarme erzeugt.
+- Die Auswahl von **VT** oder **PVT** im Admin-Fenster setzt die Herzfrequenz auf **160 bpm** und aktualisiert den zugehörigen Schieberegler und das Textfeld.
+ Danach kann die Frequenz manuell geändert werden.
+ VT mit mechanischer Perfusion erzeugt weiterhin QRS-gekoppelte Pulse entsprechend der eingestellten Pulsübertragung; PVT bleibt pulslos.
+- Bei **Poor (★)** wechselt das SpO₂-Signal nach pseudozufälligen **30–180 Sekunden** mit nutzbarem, aber qualitativ schlechtem Signal für pseudozufällige **5–20 Sekunden** auf **NO READING**.
+ Der technische Alarm blinkt, SpO₂ und PR werden ausgeblendet und das Plethysmogramm verschwindet.
+ Anschließend kehrt das Signal automatisch zur Qualität Poor zurück.
+ In der simulierten Signalhistorie bleiben sichtbare Lücken für die Ausfälle erhalten.
+ Wird eine andere Signalqualität gewählt, endet der intermittierende Ausfall unmittelbar.
+- Die Adult-Alarmvoreinstellungen, die Reihenfolge der Alarmgrenzen und die arterielle Skala von 0–200 mmHg bleiben unverändert.
+ Alle Funktionen sind synthetisch und ausschließlich für die Lehre bestimmt.
+
+## NIBP-Messzyklus (v0.5.0)
+
+Der nichtinvasive Blutdruck (NIBP) wird **rot** in einem eigenen Wertefeld in
+der **rechten Monitorspalte** dargestellt. Der bisherige NIBP-Bereich am
+unteren Fensterrand entfällt. Im Admin-Fenster lässt sich ein Messintervall
+von **1, 3, 5, 10, 20, 30 oder 60 Minuten** auswählen (Standard: 5 Minuten).
+Der erste Messzyklus beginnt beim Simulationsstart. Das Folgeintervall zählt
+jeweils **ab dem Ende der vorangegangenen Messung**. Über **Measure now**
+kann während einer Messpause sofort eine neue Messung gestartet werden.
+Ein **horizontaler Fortschrittsbalken** zeigt den Ablauf des Messintervalls,
+ein **vertikaler Balken** den simulierten Manschettendruck von 0–200 mmHg.
+
+Die Messdauer wird anhand der SpO₂-Signalqualität **zu Messbeginn** bestimmt:
+
+| Signalqualität | Messdauer | Ergebnis |
+| --- | --- | --- |
+| Good (★★★) | 20 s | Messwert vorhanden |
+| Adequate (★★) | 40 s | Messwert vorhanden |
+| Poor (★) | Zufällig 60–120 s | Messwert mit 65 % simulierter Erfolgswahrscheinlichkeit |
+| None / Sensor nicht angeschlossen | 120 s | Kein Messwert |
+| **No reading** aktiviert | 120 s | Unabhängig von der Qualität kein Messwert |
+
+Die Manschette wird bis **200 mmHg** aufgepumpt. Bei guter oder adäquater
+Signalqualität folgt eine kontinuierliche Entleerung. Bei Poor oder None wird
+zunächst bis ungefähr **67 mmHg** entleert, erneut bis ungefähr **133 mmHg**
+aufgepumpt und danach vollständig entleert.
+Nach Abschluss erscheint der neue Messwert und **blinkt fünfmal durch Ein-
+und Ausblenden**, ohne Farbumkehr. Schlägt die Messung fehl, erscheint
+`---/---` (MAP `---`). Während einer laufenden Folgemessung bleibt der bisherige
+Messwert bis zum Messende sichtbar.
+
+Die **erste erfolgreiche Messung** übernimmt die im Admin-Fenster eingestellten
+NIBP-Ausgangswerte. Alle weiteren Ergebnisse werden aus den aktuellen invasiven
+arteriellen SYS-/DIA-Werten mit jeweils unabhängig zufällig gewählten
+prozentuellen Abweichungen erzeugt:
+
+| Signalqualität | Abweichung vom invasiven Blutdruck |
+| --- | --- |
+| Good | −5 % bis +5 % |
+| Adequate | −10 % bis +5 % |
+| Poor | −15 % bis −5 %, sofern die Messung gelingt |
+| None | Kein Messwert |
+
+**Cuff on SpO₂ extremity:** Befindet sich die Manschette an der Extremität
+mit dem SpO₂-Sensor, ist die effektive Signalqualität bei Manschettendruck
+**oberhalb des invasiven systolischen Drucks** None, zwischen systolischem und
+diastolischem Druck Poor und **unterhalb des diastolischen Drucks** wieder
+auf dem eingestellten Niveau. Eine Verbesserung über die eingestellte
+Signalqualität hinaus findet nicht statt.
+
+**Cuff on ART extremity:** Befindet sich die Manschette an der Extremität mit
+dem arteriellen Katheter, wird die invasive Druckkurve oberhalb des invasiven
+systolischen Drucks auf dem zuletzt gemessenen Wert eingefroren. Zwischen
+systolischem und diastolischem Druck schwankt die Kurve zwischen dem
+Manschettendruck und dem NIBP-SYS-Referenzwert. Unterhalb des diastolischen
+Drucks erscheint wieder die ursprüngliche arterielle Kurve. Die numerischen
+SYS-, DIA- und MAP-Anzeigen folgen der jeweils simulierten Kurve.
+Ohne mechanische Pulse bleibt die bisherige 0–5-mmHg-Simulation erhalten.
+Beide Manschetten-Interferenzoptionen sind standardmäßig deaktiviert.
+
+**Die NIBP-Simulation ist ausschließlich ein didaktisches Modell und keine
+klinisch validierte oszillometrische Messung.**
diff --git a/README.md b/README.md
index 21e1f99..66c1469 100644
--- a/README.md
+++ b/README.md
@@ -1,4 +1,4 @@
-# Patient Monitor Simulation (PaMSim) — v0.4.4
+# Patient Monitor Simulation (PaMSim) — v0.5.0
A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux.
@@ -22,7 +22,7 @@ session (e.g., Fedora KDE/Wayland).
**Admin sections** have a narrow colored stripe on their left edge to match the
monitor: ECG **green**, SpO₂ **yellow**, invasive arterial pressure **red**,
-capnography **light grey**, NIBP **light grey**. The Patient section remains
+capnography **light grey**, NIBP **red**. The Patient section remains
neutral. These accents are drawn by GTK and remain visible independently of
light/dark themes. This is a visual-only change; control behavior is unchanged.
@@ -40,7 +40,7 @@ Waveforms and vital signs disappear together when their respective
visibility checkbox is cleared. Remaining waveform rows expand to use the space.
Hiding a display channel does **not** stop signal generation or physiological
coupling: for example, hiding ECG does not stop ART or pleth pulses. NIBP can
-be hidden independently; this also removes its footer.
+be hidden independently; this also removes its value box from the right column.
The monitor can be resized and toggled fullscreen with **F11**; **Esc** exits
fullscreen. On Wayland, move the monitor to the presentation screen before
@@ -161,6 +161,68 @@ ART continue unaffected. The **Show on monitor** checkbox still hides the
entire SpO₂ row; sensor/quality controls leave the row visible so the status
can be taught.
+## NIBP measurement cycle (v0.5.0)
+
+NIBP is **red**, with a dedicated value box in the **right-hand numeric column**.
+The previous static NIBP footer has been removed. In Admin, choose an interval
+of **1, 3, 5, 10, 20, 30, or 60 minutes** (default 5). The initial cuff cycle
+begins when the simulation starts; subsequent intervals run **from the end of
+the last measurement**, not from its beginning. **Measure now** starts an
+additional cycle if none is in progress. The small **horizontal progress bar**
+shows the fraction of the waiting interval elapsed; a **vertical 0–200 mmHg
+gauge** shows the current cuff pressure during measurement.
+
+The duration and success are determined by the signal quality **at the start
+of the cycle** (including an absent sensor or an ongoing Poor-signal dropout).
+Changing quality while a cycle is running does not retroactively change its
+planned duration:
+
+| Starting SpO₂ quality | Cycle duration | Result |
+| --- | --- | --- |
+| Good (★★★) | 20 s | Measured |
+| Adequate (★★) | 40 s | Measured |
+| Poor (★) | Randomly 60–120 s | Simulated 65% chance of a reading |
+| None / no sensor | 120 s | No reading |
+| **No reading** checkbox | 120 s | No reading, regardless of quality |
+
+The cuff inflates to **200 mmHg** then deflates. When the starting signal is
+Poor or None, it deflates to about **67 mmHg**, reinflates to about **133 mmHg**,
+and finally deflates to zero. At the end, the completed value becomes visible
+and **blinks five times by appearing/disappearing** (without the inverted-color
+alarm effect). If the cycle fails, the displayed reading is `---/---`, with
+MAP `---`. Previous NIBP values remain visible while the next cuff cycle is
+in progress, until the new reading is available.
+
+The **first successful** measurement uses the initial NIBP SYS/DIA values from
+Admin. Subsequent successful values derive from the current invasive arterial
+SYS/DIA settings using independently sampled percentage deviations:
+
+| Starting quality | Deviation relative to IBP |
+| --- | --- |
+| Good | −5% to +5% |
+| Adequate | −10% to +5% |
+| Poor | −15% to −5%, if a reading succeeds |
+| None | No reading |
+
+Optional **Cuff on SpO₂ extremity** changes the *effective* pulse-oximeter
+quality while the cuff is inflated: above invasive systolic pressure = None;
+between invasive systolic and diastolic pressure = Poor; below invasive
+diastolic pressure = the configured quality. The quality never becomes better
+than the instructor's setting. **NO READING**, missing pleth waveform and
+restoration of the waveform are handled as before.
+
+Optional **Cuff on ART extremity** modifies the simulated arterial transducer
+trace during cuff inflation: above invasive SYS it freezes at the last measured
+pressure; between invasive SYS and DIA it pulsates between the cuff pressure
+and the currently available NIBP SYS reference; below invasive DIA it returns
+to the normal arterial waveform. The ART numerical SYS/DIA/MAP values also
+reflect this altered trace. With absent mechanical cardiac capture, the
+previous pulseless 0–5 mmHg simulation is retained and no artificial pulses
+are introduced. Both cuff-interference options are off by default.
+
+These cuff and SpO₂ interactions are **deliberately simplified training
+artifacts**; they should not be interpreted as validated cuff oscillometry.
+
## ECG and mechanical coupling
- ECG rhythms: sinus, atrial fibrillation, monomorphic ventricular tachycardia
@@ -177,8 +239,8 @@ can be taught.
drifts smoothly at 0–5 mmHg rather than representing a pulsatile pressure.
The ART **SYS** number shows the rounded low transducer pressure (0–5 mmHg),
while DIA and MAP show `--` because they cannot be reliably estimated.
- Previous pressure samples scroll out of view. NIBP is a static,
- separately entered cuff reading.
+ Previous pressure samples scroll out of view. NIBP follows a separate,
+ time-based simulated cuff-measurement cycle.
## Invasive arterial pressure and PPV (new in v0.3)
@@ -228,7 +290,7 @@ The five **Show on monitor** checkboxes affect the presentation only:
| Pulse oximetry | Pleth waveform, SpO₂ and PR |
| Invasive arterial blood pressure | ART waveform, pressure values, MAP and PPV label |
| Capnography | CO₂ waveform, EtCO₂ and RR |
-| NIBP | Static cuff pressure values and NIBP footer |
+| NIBP | Timed cuff-measurement values and red right-column value box |
Remaining visible waveforms keep their relative order and receive an equal
share of the available area; zero waveform channels is supported.
@@ -263,8 +325,8 @@ are simulated.
The arterial pulse thus retains the same amplitude throughout the beat.
- Varying PPV does not alter the peripheral pleth pulse or the number of
mechanical pulses.
-- Clinical accuracy, dynamic NIBP measurements, alarms, artifacts, calibration,
- precise waveform timing, and patient physiology are outside this prototype.
+- Clinical accuracy, calibration, artifact realism and patient-specific physiology
+ are outside this prototype; its NIBP cycle and alarms are synthetic.
## Project layout
@@ -274,6 +336,7 @@ src/
model.rs Parameters, rhythm/capture settings, display flags
simulation.rs QRS-timed mechanical signals, PPV and respiratory synthesis
render.rs Cairo monitor layout, dynamic visibility, fixed ART axis
+ nibp.rs Scheduled cuff measurements and measurement results
ui.rs Admin controls and monitor window
```
@@ -282,7 +345,7 @@ src/
1. Respiratory PPV with a 0–60% instructor setting, coupled to the simulated
respiratory cycle and applied **per arterial beat**.
2. Five independent display visibility toggles, dynamic waveform row layout,
- and independent NIBP-footer hiding.
+ and independent NIBP value-box hiding.
3. ART axis reduced from **0–250** to **0–200 mmHg**, with inputs adjusted to
the new range.
4. Added regression tests for PPV arithmetic and its effects on ART, for
diff --git a/src/main.rs b/src/main.rs
index 462badd..59eb605 100644
--- a/src/main.rs
+++ b/src/main.rs
@@ -1,4 +1,5 @@
mod model;
+mod nibp;
mod render;
mod simulation;
mod ui;
diff --git a/src/model.rs b/src/model.rs
index 4d0bc9b..47e9b74 100644
--- a/src/model.rs
+++ b/src/model.rs
@@ -94,6 +94,10 @@ pub enum Spo2Quality {
}
impl Spo2Quality {
+ pub fn min(self, other: Self) -> Self {
+ if (self as u8) <= (other as u8) { self } else { other }
+ }
+
pub fn stars(self) -> &'static str {
match self {
Self::None => "",
@@ -207,8 +211,12 @@ pub struct Parameters {
pub art_diastolic: i32, // mmHg
pub arterial_shape: ArterialShape,
pub pulse_pressure_variation: i32, // PPV %, 0 disables respiratory variation
- pub nibp_systolic: i32, // mmHg, historical/static simulated cuff value
- pub nibp_diastolic: i32, // mmHg
+ pub nibp_systolic: i32, // mmHg, initial measured NIBP result
+ pub nibp_diastolic: i32, // mmHg, initial measured NIBP result
+ pub nibp_interval_minutes: i32, // 1 / 3 / 5 / 10 / 20 / 30 / 60
+ pub nibp_no_reading: bool, // force unsuccessful cuff measurement
+ pub nibp_cuff_on_spo2: bool, // simulated probe on cuff extremity
+ pub nibp_cuff_on_art: bool, // simulated arterial catheter on cuff extremity
pub etco2: i32, // mmHg
pub respiratory_rate: i32, // breaths/min
pub capno_shape: CapnoShape,
@@ -237,13 +245,14 @@ impl Parameters {
self.spo2_status_during(pulse_rate, false)
}
- /// Poor-quality signal interruptions are generated by the simulator and
- /// override the normal reading, but not a physically disconnected sensor.
- pub fn spo2_status_during(&self, pulse_rate: Option<i32>, signal_lost: bool) -> Spo2Status {
+ /// Effective quality can be temporarily reduced by an NIBP cuff on the
+ /// same extremity. A detached probe still has highest priority.
+ pub fn spo2_status_at_quality(&self, pulse_rate: Option<i32>, signal_lost: bool,
+ effective_quality: Spo2Quality) -> Spo2Status {
if !self.spo2_sensor_attached {
Spo2Status::NoSensor
} else if (signal_lost && self.spo2_quality == Spo2Quality::Poor)
- || self.spo2_quality == Spo2Quality::None || pulse_rate.is_none()
+ || effective_quality == Spo2Quality::None || pulse_rate.is_none()
|| !self.ecg_rhythm.can_generate_pulse()
|| self.pulse_conduction == PulseConduction::None
|| self.heart_rate <= 0
@@ -253,6 +262,12 @@ impl Parameters {
Spo2Status::Available
}
}
+
+ /// Quality without cuff interference; retained for regression tests.
+ #[cfg(test)]
+ pub fn spo2_status_during(&self, pulse_rate: Option<i32>, signal_lost: bool) -> Spo2Status {
+ self.spo2_status_at_quality(pulse_rate, signal_lost, self.spo2_quality)
+ }
}
impl Default for Parameters {
@@ -272,6 +287,10 @@ impl Default for Parameters {
pulse_pressure_variation: 0,
nibp_systolic: 118,
nibp_diastolic: 74,
+ nibp_interval_minutes: 5,
+ nibp_no_reading: false,
+ nibp_cuff_on_spo2: false,
+ nibp_cuff_on_art: false,
etco2: 38,
respiratory_rate: 14,
capno_shape: CapnoShape::Normal,
diff --git a/src/nibp.rs b/src/nibp.rs
new file mode 100644
index 0000000..4078915
--- /dev/null
+++ b/src/nibp.rs
@@ -0,0 +1,308 @@
+//! Synthetic oscillometric NIBP cuff cycle; no physiological or diagnostic validity.
+//! All time is measured in simulation seconds so the behavior is independent of FPS.
+
+use crate::model::{Parameters, Spo2Quality};
+
+#[derive(Clone, Copy, Debug, PartialEq, Eq)]
+pub struct NibpReading {
+ pub systolic: i32,
+ pub diastolic: i32,
+}
+
+impl NibpReading {
+ pub fn mean(self) -> i32 {
+ crate::model::mean_arterial_pressure(self.systolic, self.diastolic)
+ }
+}
+
+#[derive(Clone, Copy, Debug, PartialEq, Eq)]
+pub enum CuffZone {
+ Free,
+ Partial,
+ Occluded,
+}
+
+#[derive(Clone, Copy, Debug)]
+struct Cycle {
+ start: f64,
+ duration: f64,
+ quality_at_start: Spo2Quality,
+ first: bool,
+ first_reading: NibpReading,
+}
+
+#[derive(Debug)]
+pub struct NibpMachine {
+ cycle: Option<Cycle>,
+ ever_started: bool,
+ ever_successful: bool,
+ last_completed: Option<f64>,
+ last_reading: Option<NibpReading>,
+ last_success_at: Option<f64>,
+ rng: u64,
+}
+
+impl NibpMachine {
+ pub fn new() -> Self {
+ Self {
+ cycle: None,
+ ever_started: false,
+ ever_successful: false,
+ last_completed: None,
+ last_reading: None,
+ last_success_at: None,
+ rng: 0xC4E3_1A86_957B_1D29,
+ }
+ }
+
+ fn random_unit(&mut self) -> f64 {
+ self.rng = self.rng.wrapping_mul(6_364_136_223_846_793_005)
+ .wrapping_add(1_442_695_040_888_963_407);
+ (self.rng >> 11) as f64 / (1_u64 << 53) as f64
+ }
+
+ fn random_between(&mut self, low: f64, high: f64) -> f64 {
+ low + self.random_unit() * (high - low)
+ }
+
+ pub fn measuring(&self) -> bool {
+ self.cycle.is_some()
+ }
+
+ pub fn reading(&self) -> Option<NibpReading> {
+ self.last_reading
+ }
+
+ /// Time since the last completed measurement as a fraction of the interval.
+ /// While measuring, the waiting progress resets to zero.
+ pub fn interval_progress(&self, now: f64, minutes: i32) -> f64 {
+ if self.cycle.is_some() { return 0.0; }
+ let Some(last) = self.last_completed else { return 0.0; };
+ ((now - last) / (f64::from(minutes.max(1)) * 60.0)).clamp(0.0, 1.0)
+ }
+
+ /// Five appearances/disappearances over five seconds (no color inversion).
+ pub fn show_new_value(&self, now: f64) -> bool {
+ let Some(last) = self.last_success_at else { return true; };
+ let elapsed = now - last;
+ !(0.0..5.0).contains(&elapsed) || (elapsed * 2.0).floor() as i32 % 2 == 0
+ }
+
+ pub fn cuff_pressure(&self, now: f64) -> f64 {
+ let Some(cycle) = self.cycle else { return 0.0; };
+ let t = ((now - cycle.start) / cycle.duration).clamp(0.0, 1.0);
+ let poor = matches!(cycle.quality_at_start, Spo2Quality::Poor | Spo2Quality::None);
+ (if !poor {
+ if t < 0.13 { 200.0 * t / 0.13 }
+ else { 200.0 * (1.0 - t) / 0.87 }
+ } else if t < 0.13 {
+ 200.0 * t / 0.13
+ } else if t < 0.54 {
+ // First deflation stops at one third of the maximum pressure.
+ 200.0 - (200.0 - 200.0 / 3.0) * (t - 0.13) / 0.41
+ } else if t < 0.71 {
+ // Reinflation to two thirds of maximum pressure.
+ 200.0 / 3.0 + (200.0 / 3.0) * (t - 0.54) / 0.17
+ } else {
+ (400.0 / 3.0) * (1.0 - t) / 0.29
+ }).clamp(0.0, 200.0)
+ }
+
+ pub fn cuff_zone(&self, now: f64, params: &Parameters) -> CuffZone {
+ if !self.measuring() { return CuffZone::Free; }
+ let pressure = self.cuff_pressure(now);
+ if pressure > f64::from(params.art_systolic) { CuffZone::Occluded }
+ else if pressure > f64::from(params.art_diastolic) { CuffZone::Partial }
+ else { CuffZone::Free }
+ }
+
+ pub fn effective_spo2_quality(&self, now: f64, p: &Parameters) -> Spo2Quality {
+ if !p.nibp_cuff_on_spo2 { return p.spo2_quality; }
+ match self.cuff_zone(now, p) {
+ CuffZone::Occluded => Spo2Quality::None,
+ CuffZone::Partial => p.spo2_quality.min(Spo2Quality::Poor),
+ CuffZone::Free => p.spo2_quality,
+ }
+ }
+
+ fn start(&mut self, now: f64, p: &Parameters, quality: Spo2Quality) {
+ let quality = if p.nibp_no_reading { Spo2Quality::None } else { quality };
+ let duration = match quality {
+ Spo2Quality::Good => 20.0,
+ Spo2Quality::Adequate => 40.0,
+ Spo2Quality::Poor => self.random_between(60.0, 120.0),
+ Spo2Quality::None => 120.0,
+ };
+ self.cycle = Some(Cycle {
+ start: now,
+ duration,
+ quality_at_start: quality,
+ first: !self.ever_successful,
+ first_reading: NibpReading {
+ systolic: p.nibp_systolic,
+ diastolic: p.nibp_diastolic,
+ },
+ });
+ self.ever_started = true;
+ }
+
+ /// The initial cycle starts at simulation time zero. Afterwards, the
+ /// interval is counted from the last completed measurement, not cycle start.
+ pub fn update(&mut self, now: f64, p: &Parameters, quality_at_start: Spo2Quality) {
+ if now < 0.0 { return; }
+ if let Some(cycle) = self.cycle {
+ if now - cycle.start >= cycle.duration {
+ self.complete(now, p, cycle);
+ }
+ } else if !self.ever_started || self.last_completed.is_some_and(|last| {
+ now - last >= f64::from(p.nibp_interval_minutes.max(1)) * 60.0
+ }) {
+ self.start(now, p, quality_at_start);
+ }
+ }
+
+ /// Instructor-triggered measurement; ignored if a cuff cycle is in progress.
+ pub fn measure_now(&mut self, now: f64, p: &Parameters, quality: Spo2Quality) {
+ if !self.measuring() { self.start(now.max(0.0), p, quality); }
+ }
+
+ fn complete(&mut self, now: f64, p: &Parameters, cycle: Cycle) {
+ let successful = match cycle.quality_at_start {
+ Spo2Quality::None => false,
+ Spo2Quality::Poor => self.random_unit() < 0.65,
+ Spo2Quality::Adequate | Spo2Quality::Good => true,
+ };
+ self.last_reading = if successful {
+ let reading = if cycle.first {
+ cycle.first_reading
+ } else {
+ let (low, high) = match cycle.quality_at_start {
+ Spo2Quality::Good => (-0.05, 0.05),
+ Spo2Quality::Adequate => (-0.10, 0.05),
+ Spo2Quality::Poor => (-0.15, -0.05),
+ Spo2Quality::None => (0.0, 0.0),
+ };
+ // Independent random deviation for SYS and DIA; preserve SYS >= DIA.
+ let sys = (f64::from(p.art_systolic) * (1.0 + self.random_between(low, high)))
+ .round().clamp(0.0, 260.0) as i32;
+ let dia = (f64::from(p.art_diastolic) * (1.0 + self.random_between(low, high)))
+ .round().clamp(0.0, f64::from(sys)) as i32;
+ NibpReading { systolic: sys, diastolic: dia }
+ };
+ self.last_success_at = Some(now);
+ self.ever_successful = true;
+ Some(reading)
+ } else {
+ self.last_success_at = None;
+ None
+ };
+ self.cycle = None;
+ self.last_completed = Some(now);
+ }
+}
+
+#[cfg(test)]
+mod tests {
+ use super::*;
+
+ #[test]
+ fn intervals_and_first_values() {
+ let mut m = NibpMachine::new();
+ let p = Parameters::default();
+ m.update(0.0, &p, Spo2Quality::Good);
+ assert!(m.measuring());
+ assert_eq!(m.reading(), None);
+ assert!((m.cuff_pressure(2.6) - 200.0).abs() < 0.1);
+ m.update(20.0, &p, Spo2Quality::Good);
+ assert_eq!(m.reading(), Some(NibpReading { systolic: 118, diastolic: 74 }));
+ assert!(!m.measuring());
+ assert!(m.show_new_value(20.1));
+ assert!(!m.show_new_value(20.6));
+ assert!(m.show_new_value(25.1));
+ assert!((m.interval_progress(170.0, 5) - 0.5).abs() < 1e-6);
+ m.update(319.9, &p, Spo2Quality::Good);
+ assert!(!m.measuring());
+ m.update(320.0, &p, Spo2Quality::Good);
+ assert!(m.measuring());
+ m.update(340.0, &p, Spo2Quality::Good);
+ assert!(m.reading().is_some());
+ let result = m.reading().unwrap();
+ assert!((result.systolic - p.art_systolic).abs() <= 6);
+ assert!((result.diastolic - p.art_diastolic).abs() <= 4);
+ }
+
+ #[test]
+ fn failed_measurement_and_retry_cycle() {
+ let p = Parameters { nibp_no_reading: true, ..Parameters::default() };
+ let mut m = NibpMachine::new();
+ m.update(0.0, &p, Spo2Quality::Good);
+ assert!(m.measuring());
+ assert!((m.cuff_pressure(15.6) - 200.0).abs() < 0.1);
+ assert!((m.cuff_pressure(64.8) - 200.0/3.0).abs() < 0.1);
+ assert!((m.cuff_pressure(85.2) - 400.0/3.0).abs() < 0.1);
+ m.update(120.0, &p, Spo2Quality::Good);
+ assert!(m.reading().is_none());
+ }
+
+ #[test]
+ fn cuff_interference_never_improves_quality() {
+ let p = Parameters { nibp_cuff_on_spo2: true, ..Parameters::default() };
+ let mut m = NibpMachine::new();
+ m.update(0.0, &p, Spo2Quality::Good);
+ assert_eq!(m.effective_spo2_quality(2.6, &p), Spo2Quality::None);
+ assert_eq!(m.effective_spo2_quality(10.0, &p), Spo2Quality::Poor);
+ assert_eq!(m.effective_spo2_quality(19.0, &p), Spo2Quality::Good);
+ let p = Parameters { spo2_quality: Spo2Quality::Poor, ..p };
+ assert_eq!(m.effective_spo2_quality(10.0, &p), Spo2Quality::Poor);
+ }
+}
+
+#[cfg(test)]
+mod more_tests {
+ use super::*;
+
+ #[test]
+ fn quality_determines_cycle_duration() {
+ for (quality, seconds) in [
+ (Spo2Quality::Good, 20.0),
+ (Spo2Quality::Adequate, 40.0),
+ (Spo2Quality::None, 120.0),
+ ] {
+ let mut machine = NibpMachine::new();
+ let p = Parameters::default();
+ machine.update(0.0, &p, quality);
+ machine.update(seconds - 0.01, &p, quality);
+ assert!(machine.measuring());
+ machine.update(seconds, &p, quality);
+ assert!(!machine.measuring());
+ assert_eq!(machine.reading().is_some(), quality != Spo2Quality::None);
+ }
+ let mut machine = NibpMachine::new();
+ let p = Parameters::default();
+ machine.update(0.0, &p, Spo2Quality::Poor);
+ assert!((60.0..=120.0).contains(&machine.cycle.unwrap().duration));
+ }
+
+ #[test]
+ fn first_successful_reading_uses_admin_even_after_failed_cycle() {
+ let mut p = Parameters { nibp_no_reading: true, ..Parameters::default() };
+ let mut machine = NibpMachine::new();
+ machine.update(0.0, &p, Spo2Quality::None);
+ machine.update(120.0, &p, Spo2Quality::None);
+ assert!(machine.reading().is_none());
+ p.nibp_no_reading = false;
+ machine.measure_now(121.0, &p, Spo2Quality::Good);
+ machine.update(141.0, &p, Spo2Quality::Good);
+ assert_eq!(machine.reading(), Some(NibpReading { systolic: 118, diastolic: 74 }));
+ }
+
+ #[test]
+ fn partial_pressure_uses_diastic_and_systolic_boundaries() {
+ let p = Parameters { nibp_cuff_on_art: true, ..Parameters::default() };
+ let mut machine = NibpMachine::new();
+ machine.update(0.0, &p, Spo2Quality::Good);
+ assert_eq!(machine.cuff_zone(2.6, &p), CuffZone::Occluded);
+ assert_eq!(machine.cuff_zone(10.0, &p), CuffZone::Partial);
+ assert_eq!(machine.cuff_zone(19.0, &p), CuffZone::Free);
+ }
+}
diff --git a/src/render.rs b/src/render.rs
index 3412859..def9706 100644
--- a/src/render.rs
+++ b/src/render.rs
@@ -1,7 +1,7 @@
//! Size-independent Cairo drawing of the synthetic bedside monitor.
use gtk::cairo::{Context, FontSlant, FontWeight, LineCap, LineJoin};
-use crate::model::{mean_arterial_pressure, AlarmLimits, AlarmState, Parameters, PulseConduction, Spo2Quality, Spo2Status};
+use crate::model::{AlarmLimits, AlarmState, Parameters, PulseConduction, Spo2Quality, Spo2Status};
use crate::simulation::{Sample, Simulator};
type Color = (f64, f64, f64);
@@ -33,10 +33,14 @@ pub fn draw(cr: &Context, width: i32, height: i32, p: &Parameters, sim: &Simulat
let pad = (w.min(h) * 0.018).clamp(6.0, 20.0);
let header = (h * 0.083).clamp(32.0, 68.0);
- let footer = if p.show_nibp { (h * 0.13).clamp(52.0, 102.0) } else { 0.0 };
let channels = visible_channels(p);
- let row_height = ((h - header - footer - pad).max(20.0))
- / (channels.len().max(1) as f64);
+ let body_height = (h - header - pad).max(20.0);
+ // NIBP occupies a dedicated box at the bottom of the numerical right column.
+ // Trace rows remain full height on the left.
+ let nibp_box_height = if p.show_nibp { (h * 0.24).clamp(135.0, 210.0).min(body_height * 0.55) }
+ else { 0.0 };
+ let trace_row_height = body_height / channels.len().max(1) as f64;
+ let vital_row_height = (body_height - nibp_box_height) / channels.len().max(1) as f64;
let sidebar = (w * 0.235).clamp(125.0, 370.0).min(w * 0.44);
let split_x = w - sidebar - pad;
let trace_left = pad + 6.0;
@@ -60,60 +64,112 @@ pub fn draw(cr: &Context, width: i32, height: i32, p: &Parameters, sim: &Simulat
11.0 * text_scale, MUTED, false);
}
stroke_line(cr, pad, header, w - pad, header, MUTED, 0.8);
- stroke_line(cr, split_x, header, split_x, h - footer, MUTED, 0.9);
+ stroke_line(cr, split_x, header, split_x, h - pad, MUTED, 0.9);
for (index, (channel, title, color)) in channels.iter().copied().enumerate() {
- let top = header + index as f64 * row_height;
- let bottom = top + row_height;
- stroke_line(cr, pad, bottom, w - pad, bottom, MUTED, 0.65);
- text(cr, title, trace_left + 4.0, top + row_height * 0.17,
- (row_height * 0.11).clamp(10.0, 17.0), color, false);
+ let top = header + index as f64 * trace_row_height;
+ let bottom = top + trace_row_height;
+ stroke_line(cr, pad, bottom, split_x, bottom, MUTED, 0.65);
+ text(cr, title, trace_left + 4.0, top + trace_row_height * 0.17,
+ (trace_row_height * 0.11).clamp(10.0, 17.0), color, false);
draw_trace(cr, channel, color, trace_left, trace_right,
- top + row_height * 0.25, bottom - row_height * 0.06, p, sim);
+ top + trace_row_height * 0.25, bottom - trace_row_height * 0.06, p, sim);
+ let vital_top = header + index as f64 * vital_row_height;
+ stroke_line(cr, split_x, vital_top + vital_row_height,
+ w - pad, vital_top + vital_row_height, MUTED, 0.65);
draw_vitals(cr, channel, color, split_x + pad,
- top, row_height, sidebar - 2.0 * pad, p, sim);
+ vital_top, vital_row_height, sidebar - 2.0 * pad, p, sim);
}
if p.show_nibp {
- let footer_top = h - footer;
- let flash = alarm_flash_on(sim);
- let mean = mean_arterial_pressure(p.nibp_systolic, p.nibp_diastolic);
- text(cr, "NIBP", pad + 6.0, footer_top + footer * 0.32,
- (footer * 0.21).clamp(12.0, 20.0), LIGHT_GREY, false);
- draw_pressure_value(cr, p.nibp_systolic, p.nibp_diastolic,
- pad + 6.0, footer_top + footer * 0.77,
- (footer * 0.42).clamp(20.0, 44.0),
- (w * 0.28).min(255.0).max(70.0), LIGHT_GREY,
- alarmed(p.alarms.nibp_sys, Some(p.nibp_systolic)),
- alarmed(p.alarms.nibp_dia, Some(p.nibp_diastolic)), flash);
- if w >= 510.0 {
- draw_alarm_inline(cr, pad + (w * 0.28).min(260.0),
- footer_top + footer * 0.73, (footer * 0.24).clamp(12.0, 23.0),
- (w * 0.25).max(90.0), LIGHT_GREY,
- "MAP ", &mean.to_string(), " mmHg",
- alarmed(p.alarms.nibp_map, Some(mean)), flash);
- }
- draw_alarm_annotations(cr, &[
- ("SYS", p.alarms.nibp_sys),
- ("MAP", p.alarms.nibp_map),
- ("DIA", p.alarms.nibp_dia),
- ], w - pad - 8.0, footer_top, footer, (w * 0.24).max(115.0));
+ draw_nibp_box(cr, split_x + pad, h - pad - nibp_box_height,
+ sidebar - 2.0 * pad, nibp_box_height, p, sim);
}
}
+fn draw_nibp_box(cr: &Context, x: f64, top: f64, width: f64, height: f64,
+ p: &Parameters, sim: &Simulator) {
+ let right = x + width;
+ let pressure = sim.nibp().cuff_pressure(sim.time());
+ let in_progress = sim.nibp().measuring();
+ let reading = sim.nibp().reading();
+ let value_width = (width - 35.0).max(30.0);
+ let small = (height * 0.095).clamp(10.0, 14.0);
+ let number_size = (height * 0.25).clamp(18.0, 41.0);
+ // Subtle red outline distinguishes the independent cuff reading box.
+ let _ = cr.save();
+ cr.set_source_rgb(0.28, 0.09, 0.10);
+ cr.set_line_width(1.0);
+ cr.rectangle(x - 7.0, top, width + 13.0, height - 1.0);
+ let _ = cr.stroke();
+ let _ = cr.restore();
+ text(cr, "NIBP", x, top + height * 0.13, small * 1.15, RED, true);
+ if in_progress {
+ text(cr, "MEASURING", x, top + height * 0.27, small, RED, false);
+ } else {
+ text(cr, "mmHg", x, top + height * 0.27, small, MUTED, false);
+ }
+
+ if sim.nibp().show_new_value(sim.time()) {
+ let (sys, dia) = reading.map_or(("---".to_owned(), "---".to_owned()), |r|
+ (r.systolic.to_string(), r.diastolic.to_string()));
+ draw_pressure_components(cr, &sys, &dia, x, top + height * 0.60,
+ number_size, value_width, RED,
+ alarmed(p.alarms.nibp_sys, reading.map(|r| r.systolic)),
+ alarmed(p.alarms.nibp_dia, reading.map(|r| r.diastolic)), alarm_flash_on(sim));
+ let map = reading.map_or("---".to_owned(), |r| r.mean().to_string());
+ draw_alarm_inline(cr, x, top + height * 0.72, small * 1.15, value_width,
+ RED, "MAP ", &map, " mmHg",
+ alarmed(p.alarms.nibp_map, reading.map(|r| r.mean())), alarm_flash_on(sim));
+ }
+
+ // Horizontal: elapsed fraction of the selected measurement interval.
+ let progress_y = top + height * 0.85;
+ let progress_width = (width - 9.0).max(8.0);
+ stroke_line(cr, x, progress_y, x + progress_width, progress_y, MUTED, 4.0);
+ stroke_line(cr, x, progress_y,
+ x + progress_width * sim.nibp().interval_progress(sim.time(), p.nibp_interval_minutes),
+ progress_y, RED, 4.0);
+ text(cr, &format!("Every {} min", p.nibp_interval_minutes),
+ x, top + height * 0.97, small * 0.85, MUTED, false);
+
+ // Vertical cuff-pressure gauge (0..200 mmHg), always visible when measuring.
+ let gauge_x = right - 15.0;
+ let gauge_top = top + height * 0.31;
+ let gauge_h = height * 0.40;
+ stroke_line(cr, gauge_x, gauge_top, gauge_x, gauge_top + gauge_h, MUTED, 7.0);
+ if in_progress {
+ stroke_line(cr, gauge_x, gauge_top + gauge_h,
+ gauge_x, gauge_top + gauge_h * (1.0 - pressure / 200.0), RED, 6.0);
+ }
+ text(cr, &format!("{:.0}", pressure), gauge_x - 12.0,
+ gauge_top - 3.0, small * 0.75, RED, false);
+ draw_alarm_annotations(cr, &[
+ ("SYS", p.alarms.nibp_sys),
+ ("MAP", p.alarms.nibp_map),
+ ("DIA", p.alarms.nibp_dia),
+ ], right, top, height * 0.65, width * 0.72);
+}
+
fn pleth_trace_enabled(p: &Parameters) -> bool {
p.spo2_sensor_attached && p.spo2_quality != Spo2Quality::None
}
+#[cfg(test)]
fn spo2_vitals(p: &Parameters, pulse_rate: Option<i32>, signal_lost: bool)
-> (String, String, String) {
- match p.spo2_status_during(pulse_rate, signal_lost) {
+ spo2_vitals_at_quality(p, pulse_rate, signal_lost, p.spo2_quality)
+}
+
+fn spo2_vitals_at_quality(p: &Parameters, pulse_rate: Option<i32>, signal_lost: bool,
+ quality: Spo2Quality) -> (String, String, String) {
+ match p.spo2_status_at_quality(pulse_rate, signal_lost, quality) {
Spo2Status::NoSensor => (
"SpO₂".to_owned(), "NO SENSOR".to_owned(), "PR -- bpm".to_owned()),
Spo2Status::NoReading => (
"SpO₂".to_owned(), "NO READING".to_owned(), "PR -- bpm".to_owned()),
Spo2Status::Available => (
- format!("SpO₂ {}", p.spo2_quality.stars()),
+ format!("SpO₂ {}", quality.stars()),
p.spo2.to_string(),
format!("% PR {} bpm", pulse_rate.unwrap_or_default()),
),
@@ -144,9 +200,8 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64,
let ecg_hr = if p.ecg_rhythm.has_qrs() && p.heart_rate > 0 {
Some(p.heart_rate)
} else { None };
- let spo2_status = p.spo2_status_during(pulse_rate, sim.poor_signal_lost());
+ let spo2_status = p.spo2_status_at_quality(pulse_rate, sim.poor_signal_lost(), sim.spo2_quality(p));
let oxygen = if spo2_status == Spo2Status::Available { Some(p.spo2) } else { None };
- let art_map = mean_arterial_pressure(p.art_systolic, p.art_diastolic);
let limits: Vec<(&str, AlarmLimits)> = match ch {
Channel::Ecg => vec![("HR", p.alarms.hr)],
@@ -174,7 +229,8 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64,
}
}
Channel::Pleth => {
- let (label, value, info) = spo2_vitals(p, pulse_rate, sim.poor_signal_lost());
+ let (label, value, info) = spo2_vitals_at_quality(p, pulse_rate,
+ sim.poor_signal_lost(), sim.spo2_quality(p));
text(cr, &label, x, top + row_h * 0.24, label_size, color, false);
let technical_alarm = spo2_status != Spo2Status::Available;
let value_size = if technical_alarm {
@@ -192,36 +248,27 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64,
}
Channel::Art => {
text(cr, "ART", x, top + row_h * 0.24, label_size, color, false);
- if pulse_rate.is_some() {
- draw_pressure_value(cr, p.art_systolic, p.art_diastolic,
- x, value_y, number_size * 0.78, width, color,
- alarmed(p.alarms.art_sys, Some(p.art_systolic)),
- alarmed(p.alarms.art_dia, Some(p.art_diastolic)), flash);
- if p.pulse_pressure_variation > 0 || p.alarms.ppv.enabled() {
- let map_text = art_map.to_string();
- let ppv_text = p.pulse_pressure_variation.to_string();
- draw_alarm_parts(cr, x, info_y, sub_size, width, color, &[
- ("MAP ", false),
- (&map_text, alarmed(p.alarms.art_map, Some(art_map))),
- (" · PPV ", false),
- (&ppv_text, alarmed(p.alarms.ppv, Some(p.pulse_pressure_variation))),
- ("%", false),
- ], flash);
- } else {
- draw_alarm_inline(cr, x, info_y, sub_size, width, color,
- "MAP ", &art_map.to_string(), " mmHg",
- alarmed(p.alarms.art_map, Some(art_map)), flash);
- }
+ let (sys, dia, map) = sim.displayed_art_pressures(p, pulse_rate.is_some());
+ let sys_text = sys.map_or("--".to_owned(), |v| v.to_string());
+ let dia_text = dia.map_or("--".to_owned(), |v| v.to_string());
+ draw_pressure_components(cr, &sys_text, &dia_text,
+ x, value_y, number_size * 0.78, width, color,
+ alarmed(p.alarms.art_sys, sys),
+ alarmed(p.alarms.art_dia, dia), flash);
+ let map_text = map.map_or("--".to_owned(), |v| v.to_string());
+ if p.pulse_pressure_variation > 0 || p.alarms.ppv.enabled() {
+ let ppv_text = p.pulse_pressure_variation.to_string();
+ draw_alarm_parts(cr, x, info_y, sub_size, width, color, &[
+ ("MAP ", false),
+ (&map_text, alarmed(p.alarms.art_map, map)),
+ (" · PPV ", false),
+ (&ppv_text, alarmed(p.alarms.ppv, Some(p.pulse_pressure_variation))),
+ ("%", false),
+ ], flash);
} else {
- // Without mechanical activity the transducer still reads the
- // slowly drifting 0..5 mmHg pressure. DIA/MAP are indeterminate.
- let pulseless = !has_capture;
- let sys = if pulseless { sim.measured_art_pressure() } else { None };
- let displayed_sys = sys.map_or_else(|| "--".to_owned(), |v| v.to_string());
- draw_pressure_components(cr, &displayed_sys, "--", x, value_y,
- number_size * 0.78, width, color,
- alarmed(p.alarms.art_sys, sys), false, flash);
- text(cr, "MAP -- mmHg", x, info_y, sub_size, color, false);
+ draw_alarm_inline(cr, x, info_y, sub_size, width, color,
+ "MAP ", &map_text, " mmHg",
+ alarmed(p.alarms.art_map, map), flash);
}
}
Channel::Capno => {
@@ -270,17 +317,7 @@ fn draw_alarm_number(cr: &Context, value: &str, x: f64, baseline: f64,
let _ = cr.restore();
}
-/// Draw pressure components independently: only SYS or DIA flashes when it
-/// breaches its respective limit. The separator remains the normal color.
-#[allow(clippy::too_many_arguments)]
-fn draw_pressure_value(cr: &Context, systolic: i32, diastolic: i32,
- x: f64, baseline: f64, nominal_size: f64,
- available_width: f64, color: Color,
- sys_alarm: bool, dia_alarm: bool, flash: bool) {
- draw_pressure_components(cr, &systolic.to_string(), &diastolic.to_string(),
- x, baseline, nominal_size, available_width, color, sys_alarm, dia_alarm, flash);
-}
-
+/// Draw SYS and DIA independently; their threshold alarms can invert separately.
#[allow(clippy::too_many_arguments)]
fn draw_pressure_components(cr: &Context, sys: &str, dia: &str,
x: f64, baseline: f64, nominal_size: f64,
@@ -392,7 +429,8 @@ fn draw_trace(cr: &Context, channel: Channel, color: Color,
// Disconnected or absent pleth signal: no curve, including historical pulses.
if matches!(channel, Channel::Pleth)
&& (!pleth_trace_enabled(p)
- || p.spo2_status_during(sim.pulse_rate(), sim.poor_signal_lost()) != Spo2Status::Available)
+ || p.spo2_status_at_quality(sim.pulse_rate(), sim.poor_signal_lost(),
+ sim.spo2_quality(p)) != Spo2Status::Available)
{
let _ = cr.restore();
return;
@@ -421,7 +459,7 @@ fn draw_trace(cr: &Context, channel: Channel, color: Color,
fn normalized(channel: Channel, s: &Sample, p: &Parameters) -> f64 {
match channel {
Channel::Ecg => (0.40 + s.ecg * 0.38).clamp(0.02, 0.98),
- Channel::Pleth => (0.10 + pleth_visual_amplitude(s.pleth, s.time, p.spo2_quality) * 0.78)
+ Channel::Pleth => (0.10 + pleth_visual_amplitude(s.pleth, s.time, s.pleth_quality) * 0.78)
.clamp(0.02, 0.98),
Channel::Art => (s.art / 200.0).clamp(0.0, 1.0),
Channel::Capno => (0.08 + (s.co2 / f64::from(p.etco2.max(1))) * 0.80)
@@ -602,7 +640,7 @@ mod tests {
#[test]
fn arterial_axis_is_absolute_and_fixed_to_200_mmhg() {
let p = Parameters::default();
- let mut s = Sample { time: 0.0, ecg: 0.0, pleth: 0.0, pleth_valid: true, art: 100.0, co2: 0.0 };
+ let mut s = Sample { time: 0.0, ecg: 0.0, pleth: 0.0, pleth_valid: true, pleth_quality: Spo2Quality::Good, art: 100.0, co2: 0.0 };
assert_eq!(normalized(Channel::Art, &s, &p), 0.5);
s.art = 200.0;
assert_eq!(normalized(Channel::Art, &s, &p), 1.0);
diff --git a/src/simulation.rs b/src/simulation.rs
index a2b7bc5..c148a30 100644
--- a/src/simulation.rs
+++ b/src/simulation.rs
@@ -3,6 +3,7 @@
use std::collections::VecDeque;
use crate::model::{ArterialShape, CapnoShape, EcgRhythm, Parameters, PulseConduction, Spo2Quality};
+use crate::nibp::{CuffZone, NibpMachine, NibpReading};
const SAMPLE_STEP: f64 = 0.004; // 250 Hz; adequately samples the QRS upstroke
const HISTORY_SECONDS: f64 = 10.0;
@@ -33,6 +34,7 @@ pub struct Sample {
pub ecg: f64, // arbitrary amplitude
pub pleth: f64, // attenuated, low-pass-filtered amplitude 0..1
pub pleth_valid: bool, // gaps during intermittent signal dropout
+ pub pleth_quality: Spo2Quality, // effective quality at sample time
pub art: f64, // absolute pressure in mmHg; display clips above 200
pub co2: f64, // mmHg
}
@@ -98,6 +100,8 @@ pub struct Simulator {
previous_conduction: PulseConduction,
previous_heart_rate: i32,
poor_signal_outages: PoorSignalOutages,
+ nibp: NibpMachine,
+ art_hold_pressure: Option<f64>,
pending_time: f64,
}
@@ -116,6 +120,8 @@ impl Simulator {
previous_conduction: params.pulse_conduction,
previous_heart_rate: params.heart_rate,
poor_signal_outages: PoorSignalOutages::new(),
+ nibp: NibpMachine::new(),
+ art_hold_pressure: None,
pending_time: 0.0,
};
// Prepopulate the trace and pulse history, including the initial pulse rate.
@@ -138,6 +144,53 @@ impl Simulator {
self.poor_signal_outages.active
}
+ pub fn nibp(&self) -> &NibpMachine { &self.nibp }
+
+ pub fn time(&self) -> f64 { self.time }
+
+ pub fn spo2_quality(&self, p: &Parameters) -> Spo2Quality {
+ self.nibp.effective_spo2_quality(self.time, p)
+ }
+
+ pub fn start_nibp_now(&mut self, p: &Parameters) {
+ let quality = self.nibp_start_quality(p);
+ self.nibp.measure_now(self.time, p, quality);
+ }
+
+ fn nibp_start_quality(&self, p: &Parameters) -> Spo2Quality {
+ if !p.spo2_sensor_attached || self.poor_signal_outages.active {
+ Spo2Quality::None
+ } else {
+ p.spo2_quality
+ }
+ }
+
+ /// Three displayed arterial values track the cuff-altered transducer curve.
+ pub fn displayed_art_pressures(&self, p: &Parameters, has_capture: bool)
+ -> (Option<i32>, Option<i32>, Option<i32>) {
+ if !has_capture {
+ return (self.measured_art_pressure(), None, None);
+ }
+ if p.nibp_cuff_on_art {
+ match self.nibp.cuff_zone(self.time, p) {
+ CuffZone::Occluded => {
+ let v = self.measured_art_pressure();
+ return (v, v, v);
+ }
+ CuffZone::Partial => {
+ let target = self.nibp.reading().map_or(p.nibp_systolic, |r| r.systolic) as f64;
+ let cuff = self.nibp.cuff_pressure(self.time);
+ let sys = target.max(cuff).round() as i32;
+ let dia = target.min(cuff).round() as i32;
+ return (Some(sys), Some(dia), Some(crate::model::mean_arterial_pressure(sys, dia)));
+ }
+ CuffZone::Free => {}
+ }
+ }
+ (Some(p.art_systolic), Some(p.art_diastolic),
+ Some(crate::model::mean_arterial_pressure(p.art_systolic, p.art_diastolic)))
+ }
+
/// Last arterial transducer sample, in mmHg (including slow 0..5 drift).
pub fn measured_art_pressure(&self) -> Option<i32> {
self.samples.back().map(|sample| sample.art.round() as i32)
@@ -168,6 +221,10 @@ impl Simulator {
self.time += SAMPLE_STEP;
self.poor_signal_outages.update(self.time,
params.spo2_quality == Spo2Quality::Poor && params.spo2_sensor_attached);
+ // Snapshot the unoccluded sensor quality at the start of a cuff cycle.
+ // Cuff-induced signal loss during that cycle must not change its duration.
+ let start_quality = self.nibp_start_quality(params);
+ self.nibp.update(self.time, params, start_quality);
if params.ecg_rhythm != self.previous_rhythm
|| params.pulse_conduction != self.previous_conduction
@@ -233,7 +290,8 @@ impl Simulator {
}
let ecg = ecg_amplitude(self.ecg_phase, self.time, params.ecg_rhythm, params.heart_rate);
- let (art, pleth_target) = self.mechanical_signals(params);
+ let (normal_art, pleth_target) = self.mechanical_signals(params);
+ let art = self.art_with_cuff(normal_art, params);
let smoothing = 1.0 - (-SAMPLE_STEP / PLETH_FILTER_TAU).exp();
self.filtered_pleth += smoothing * (pleth_target - self.filtered_pleth);
let pleth = self.filtered_pleth.clamp(0.0, 1.0);
@@ -242,15 +300,52 @@ impl Simulator {
capno_amplitude(self.respiratory_phase, params.capno_shape)
};
+ let pleth_quality = self.spo2_quality(params);
let pleth_valid = params.spo2_sensor_attached
- && params.spo2_quality != Spo2Quality::None
+ && pleth_quality != Spo2Quality::None
&& !self.poor_signal_outages.active;
- self.samples.push_back(Sample { time: self.time, ecg, pleth, pleth_valid, art, co2 });
+ self.samples.push_back(Sample {
+ time: self.time, ecg, pleth, pleth_valid, pleth_quality, art, co2,
+ });
while self.samples.front().is_some_and(|first| first.time < self.time - HISTORY_SECONDS) {
self.samples.pop_front();
}
}
+ fn art_with_cuff(&mut self, normal_art: f64, params: &Parameters) -> f64 {
+ if !params.nibp_cuff_on_art || !params.ecg_rhythm.can_generate_pulse()
+ || params.pulse_conduction == PulseConduction::None || params.heart_rate <= 0
+ {
+ self.art_hold_pressure = None;
+ return normal_art;
+ }
+ match self.nibp.cuff_zone(self.time, params) {
+ CuffZone::Free => {
+ self.art_hold_pressure = None;
+ normal_art
+ }
+ CuffZone::Occluded => {
+ if let Some(held) = self.art_hold_pressure {
+ held
+ } else {
+ let held = self.samples.back().map_or(normal_art, |s| s.art);
+ self.art_hold_pressure = Some(held);
+ held
+ }
+ }
+ CuffZone::Partial => {
+ self.art_hold_pressure = None;
+ let cuff = self.nibp.cuff_pressure(self.time);
+ let target = f64::from(self.nibp.reading().map_or(
+ params.nibp_systolic, |r: NibpReading| r.systolic));
+ let original_span = f64::from((params.art_systolic - params.art_diastolic).max(1));
+ let shape = ((normal_art - f64::from(params.art_diastolic)) / original_span)
+ .clamp(0.0, 1.0);
+ (cuff + (target - cuff) * shape).clamp(0.0, 260.0)
+ }
+ }
+ }
+
fn mechanical_signals(&self, params: &Parameters) -> (f64, f64) {
let systolic = params.art_systolic.clamp(0, 200) as f64;
let diastolic = params.art_diastolic.clamp(0, 200).min(params.art_systolic.clamp(0, 200)) as f64;
@@ -603,6 +698,31 @@ mod tests {
assert!(sim.samples.back().unwrap().pleth_valid);
}
+ #[test]
+ fn nibp_cuff_can_occlude_art_and_reduce_spo2_quality() {
+ let p = Parameters {
+ nibp_cuff_on_spo2: true,
+ nibp_cuff_on_art: true,
+ ..Parameters::default()
+ };
+ let mut sim = Simulator::new(&p);
+ while sim.time < 3.0 { sim.step(&p); }
+ assert_eq!(sim.nibp.cuff_zone(sim.time, &p), CuffZone::Occluded);
+ assert_eq!(sim.spo2_quality(&p), Spo2Quality::None);
+ let held = sim.samples.back().unwrap().art;
+ for _ in 0..50 { sim.step(&p); }
+ assert!((sim.samples.back().unwrap().art - held).abs() < 1e-9);
+ assert!(!sim.samples.back().unwrap().pleth_valid);
+ let (sys, dia, map) = sim.displayed_art_pressures(&p, true);
+ assert!(sys.is_some() && sys == dia && dia == map);
+ while sim.time < 10.0 { sim.step(&p); }
+ assert_eq!(sim.nibp.cuff_zone(sim.time, &p), CuffZone::Partial);
+ assert_eq!(sim.spo2_quality(&p), Spo2Quality::Poor);
+ while sim.time < 19.0 { sim.step(&p); }
+ assert_eq!(sim.nibp.cuff_zone(sim.time, &p), CuffZone::Free);
+ assert_eq!(sim.spo2_quality(&p), Spo2Quality::Good);
+ }
+
#[test]
fn pulse_rate_follows_two_to_one_capture() {
let p = Parameters { pulse_conduction: PulseConduction::TwoToOne, ..Parameters::default() };
diff --git a/src/ui.rs b/src/ui.rs
index 7000833..e77facc 100644
--- a/src/ui.rs
+++ b/src/ui.rs
@@ -15,7 +15,7 @@ use crate::simulation::Simulator;
type SharedParams = Rc<RefCell<Parameters>>;
// Match the RGB colors of the monitor traces (see render.rs).
-// NIBP uses the same light grey as the NIBP footer and capnography.
+// NIBP shares the arterial-pressure red; capnography is light grey.
type AccentColor = (f64, f64, f64);
const ECG_GREEN: AccentColor = (0.26, 1.0, 0.39);
const SPO2_YELLOW: AccentColor = (1.0, 0.85, 0.17);
@@ -25,8 +25,8 @@ const MONITOR_GREY: AccentColor = (0.80, 0.84, 0.87);
pub fn create_windows(app: &Application) {
let parameters = Rc::new(RefCell::new(Parameters::default()));
let simulator = Rc::new(RefCell::new(Simulator::new(&parameters.borrow())));
- let monitor = create_monitor(app, parameters.clone(), simulator);
- let admin = create_admin(app, parameters, &monitor);
+ let monitor = create_monitor(app, parameters.clone(), simulator.clone());
+ let admin = create_admin(app, parameters, simulator, &monitor);
// Present monitor first, then leave controls in the foreground.
monitor.present();
@@ -89,6 +89,7 @@ fn create_monitor(app: &Application, params: SharedParams,
}
fn create_admin(app: &Application, params: SharedParams,
+ simulator: Rc<RefCell<Simulator>>,
monitor: &ApplicationWindow) -> ApplicationWindow {
let window = ApplicationWindow::builder()
.application(app)
@@ -283,9 +284,9 @@ ART and pleth are delayed. VT can be perfusing; PVT, VF and asystole are pulsele
};
});
- let nibp = group(&controls, "Non-invasive blood pressure (NIBP)", Some(MONITOR_GREY));
+ let nibp = group(&controls, "Non-invasive blood pressure (NIBP)", Some(ART_RED));
add_visibility(&nibp, params.borrow().show_nibp, params.clone(), |p, show| p.show_nibp = show);
- let (nibp_sys_row, _, _) = add_numeric(&nibp, "Systolic", "mmHg", 0, 260, params.borrow().nibp_systolic,
+ let (nibp_sys_row, _, _) = add_numeric(&nibp, "Initial systolic", "mmHg", 0, 260, params.borrow().nibp_systolic,
params.clone(), |p, v| p.nibp_systolic = v);
alarm_editors.push((add_alarm_limits(&nibp_sys_row, "", "", 260,
params.borrow().alarms.nibp_sys, params.clone(), |p, v| p.alarms.nibp_sys = v,
@@ -293,12 +294,49 @@ ART and pleth are delayed. VT can be perfusing; PVT, VF and asystole are pulsele
alarm_editors.push((add_alarm_limits(&nibp, "MAP (derived)", "mmHg", 260,
params.borrow().alarms.nibp_map, params.clone(), |p, v| p.alarms.nibp_map = v,
&preset_dropdown, &updating_preset), |s| s.nibp_map));
- let (nibp_dia_row, _, _) = add_numeric(&nibp, "Diastolic", "mmHg", 0, 200, params.borrow().nibp_diastolic,
+ let (nibp_dia_row, _, _) = add_numeric(&nibp, "Initial diastolic", "mmHg", 0, 200, params.borrow().nibp_diastolic,
params.clone(), |p, v| p.nibp_diastolic = v);
alarm_editors.push((add_alarm_limits(&nibp_dia_row, "", "", 200,
params.borrow().alarms.nibp_dia, params.clone(), |p, v| p.alarms.nibp_dia = v,
&preset_dropdown, &updating_preset), |s| s.nibp_dia));
+ let _nibp_interval = add_dropdown_at(&nibp, "Measurement interval",
+ &["1 min", "3 min", "5 min", "10 min", "20 min", "30 min", "60 min"],
+ 2, params.clone(), |p, selected| {
+ p.nibp_interval_minutes = match selected {
+ 0 => 1, 1 => 3, 2 => 5, 3 => 10, 4 => 20, 5 => 30, _ => 60,
+ };
+ });
+ for (caption, current, update) in [
+ ("No reading (simulate failure)", params.borrow().nibp_no_reading,
+ (|p: &mut Parameters, on| p.nibp_no_reading = on) as fn(&mut Parameters, bool)),
+ ("Cuff on SpO₂ extremity", params.borrow().nibp_cuff_on_spo2,
+ (|p: &mut Parameters, on| p.nibp_cuff_on_spo2 = on) as fn(&mut Parameters, bool)),
+ ("Cuff on ART extremity", params.borrow().nibp_cuff_on_art,
+ (|p: &mut Parameters, on| p.nibp_cuff_on_art = on) as fn(&mut Parameters, bool)),
+ ] {
+ let checkbox = gtk::CheckButton::with_label(caption);
+ checkbox.set_active(current);
+ checkbox.connect_toggled({
+ let params = params.clone();
+ move |button| update(&mut params.borrow_mut(), button.is_active())
+ });
+ nibp.append(&checkbox);
+ }
+ let measure_now = gtk::Button::with_label("Measure now");
+ measure_now.connect_clicked({
+ let params = params.clone();
+ let simulator = simulator.clone();
+ move |_| simulator.borrow_mut().start_nibp_now(&params.borrow())
+ });
+ nibp.append(&measure_now);
+ let nibp_hint = gtk::Label::new(Some(
+ "First successful NIBP: instructor SYS/DIA above. Later values: simulated IBP-dependent readings."
+ ));
+ nibp_hint.set_xalign(0.0);
+ nibp_hint.set_wrap(true);
+ nibp.append(&nibp_hint);
+
let capno = group(&controls, "Capnography", Some(MONITOR_GREY));
add_visibility(&capno, params.borrow().show_capno, params.clone(), |p, show| p.show_capno = show);
add_dropdown(&capno, "Capnogram", &["Normal", "Obstructive / shark fin"],