SimPaM/patient-monitor-simulation/src/nibp.rs

368 lines
14 KiB
Rust
Raw Normal View History

2026-11-12 14:07:59 +01:00
//! Synthetic oscillometric NIBP cuff cycle; no physiological or diagnostic validity.
//! All time is measured in simulation seconds so the behavior is independent of FPS.
use crate::model::{Parameters, Spo2Quality};
#[derive(Clone, Copy, Debug, PartialEq, Eq)]
pub struct NibpReading {
pub systolic: i32,
pub diastolic: i32,
}
impl NibpReading {
pub fn mean(self) -> i32 {
crate::model::mean_arterial_pressure(self.systolic, self.diastolic)
}
}
#[derive(Clone, Copy, Debug, PartialEq, Eq)]
pub enum CuffZone {
Free,
Partial,
Occluded,
}
#[derive(Clone, Copy, Debug)]
struct Cycle {
start: f64,
duration: f64,
quality_at_start: Spo2Quality,
first: bool,
first_reading: NibpReading,
}
#[derive(Debug)]
pub struct NibpMachine {
cycle: Option<Cycle>,
ever_started: bool,
auto_enabled_on_last_update: bool,
2026-11-12 14:07:59 +01:00
ever_successful: bool,
last_completed: Option<f64>,
last_reading: Option<NibpReading>,
last_success_at: Option<f64>,
rng: u64,
}
impl NibpMachine {
pub fn new() -> Self {
Self {
cycle: None,
ever_started: false,
auto_enabled_on_last_update: false,
2026-11-12 14:07:59 +01:00
ever_successful: false,
last_completed: None,
last_reading: None,
last_success_at: None,
rng: 0xC4E3_1A86_957B_1D29,
}
}
fn random_unit(&mut self) -> f64 {
self.rng = self.rng.wrapping_mul(6_364_136_223_846_793_005)
.wrapping_add(1_442_695_040_888_963_407);
(self.rng >> 11) as f64 / (1_u64 << 53) as f64
}
fn random_between(&mut self, low: f64, high: f64) -> f64 {
low + self.random_unit() * (high - low)
}
pub fn measuring(&self) -> bool {
self.cycle.is_some()
}
pub fn reading(&self) -> Option<NibpReading> {
self.last_reading
}
/// Time since the last completed measurement as a fraction of the interval.
/// While measuring, the waiting progress resets to zero.
pub fn interval_progress(&self, now: f64, minutes: i32) -> f64 {
if self.cycle.is_some() { return 0.0; }
let Some(last) = self.last_completed else { return 0.0; };
((now - last) / (f64::from(minutes.max(1)) * 60.0)).clamp(0.0, 1.0)
}
/// Five appearances/disappearances over five seconds (no color inversion).
pub fn show_new_value(&self, now: f64) -> bool {
let Some(last) = self.last_success_at else { return true; };
let elapsed = now - last;
!(0.0..5.0).contains(&elapsed) || (elapsed * 2.0).floor() as i32 % 2 == 0
}
pub fn cuff_pressure(&self, now: f64) -> f64 {
let Some(cycle) = self.cycle else { return 0.0; };
let t = ((now - cycle.start) / cycle.duration).clamp(0.0, 1.0);
let poor = matches!(cycle.quality_at_start, Spo2Quality::Poor | Spo2Quality::None);
(if !poor {
if t < 0.13 { 200.0 * t / 0.13 }
else { 200.0 * (1.0 - t) / 0.87 }
} else if t < 0.13 {
200.0 * t / 0.13
} else if t < 0.54 {
// First deflation stops at one third of the maximum pressure.
200.0 - (200.0 - 200.0 / 3.0) * (t - 0.13) / 0.41
} else if t < 0.71 {
// Reinflation to two thirds of maximum pressure.
200.0 / 3.0 + (200.0 / 3.0) * (t - 0.54) / 0.17
} else {
(400.0 / 3.0) * (1.0 - t) / 0.29
}).clamp(0.0, 200.0)
}
pub fn cuff_zone(&self, now: f64, params: &Parameters) -> CuffZone {
if !self.measuring() { return CuffZone::Free; }
let pressure = self.cuff_pressure(now);
if pressure > f64::from(params.art_systolic) { CuffZone::Occluded }
else if pressure > f64::from(params.art_diastolic) { CuffZone::Partial }
else { CuffZone::Free }
}
pub fn effective_spo2_quality(&self, now: f64, p: &Parameters) -> Spo2Quality {
if !p.nibp_cuff_on_spo2 { return p.spo2_quality; }
match self.cuff_zone(now, p) {
CuffZone::Occluded => Spo2Quality::None,
CuffZone::Partial => p.spo2_quality.min(Spo2Quality::Poor),
CuffZone::Free => p.spo2_quality,
}
}
fn start(&mut self, now: f64, p: &Parameters, quality: Spo2Quality) {
let quality = if p.nibp_no_reading { Spo2Quality::None } else { quality };
let duration = match quality {
Spo2Quality::Good => 20.0,
Spo2Quality::Adequate => 40.0,
Spo2Quality::Poor => self.random_between(60.0, 120.0),
Spo2Quality::None => 120.0,
};
self.cycle = Some(Cycle {
start: now,
duration,
quality_at_start: quality,
first: !self.ever_successful,
first_reading: NibpReading {
systolic: p.nibp_systolic,
diastolic: p.nibp_diastolic,
},
});
self.ever_started = true;
}
/// Automatic cycles only start if the instructor enabled Auto measurement.
/// In-flight manual/automatic cycles complete even after Auto is turned off.
/// When Auto is switched on, a cycle begins immediately (if idle);
/// later cycles start at the interval after the previous completion.
2026-11-12 14:07:59 +01:00
pub fn update(&mut self, now: f64, p: &Parameters, quality_at_start: Spo2Quality) {
if now < 0.0 { return; }
let just_enabled_auto = p.nibp_auto_measurement && !self.auto_enabled_on_last_update;
self.auto_enabled_on_last_update = p.nibp_auto_measurement;
2026-11-12 14:07:59 +01:00
if let Some(cycle) = self.cycle {
if now - cycle.start >= cycle.duration {
self.complete(now, p, cycle);
}
} else if p.nibp_auto_measurement &&
(just_enabled_auto || !self.ever_started || self.last_completed.is_some_and(|last| {
now - last >= f64::from(p.nibp_interval_minutes.max(1)) * 60.0
})) {
2026-11-12 14:07:59 +01:00
self.start(now, p, quality_at_start);
}
}
/// Instructor-triggered measurement; ignored if a cuff cycle is in progress.
pub fn measure_now(&mut self, now: f64, p: &Parameters, quality: Spo2Quality) {
if !self.measuring() { self.start(now.max(0.0), p, quality); }
}
fn complete(&mut self, now: f64, p: &Parameters, cycle: Cycle) {
let successful = match cycle.quality_at_start {
Spo2Quality::None => false,
Spo2Quality::Poor => self.random_unit() < 0.65,
Spo2Quality::Adequate | Spo2Quality::Good => true,
};
self.last_reading = if successful {
let reading = if cycle.first {
cycle.first_reading
} else {
let (low, high) = match cycle.quality_at_start {
Spo2Quality::Good => (-0.05, 0.05),
Spo2Quality::Adequate => (-0.10, 0.05),
Spo2Quality::Poor => (-0.15, -0.05),
Spo2Quality::None => (0.0, 0.0),
};
// Independent random deviation for SYS and DIA; preserve SYS >= DIA.
let sys = (f64::from(p.art_systolic) * (1.0 + self.random_between(low, high)))
.round().clamp(0.0, 260.0) as i32;
let dia = (f64::from(p.art_diastolic) * (1.0 + self.random_between(low, high)))
.round().clamp(0.0, f64::from(sys)) as i32;
NibpReading { systolic: sys, diastolic: dia }
};
self.last_success_at = Some(now);
self.ever_successful = true;
Some(reading)
} else {
self.last_success_at = None;
None
};
self.cycle = None;
self.last_completed = Some(now);
}
}
#[cfg(test)]
mod tests {
use super::*;
#[test]
fn startup_is_blank_and_auto_is_disabled() {
let p = Parameters::default();
assert!(!p.nibp_auto_measurement);
let mut m = NibpMachine::new();
for t in [0.0, 20.0, 3600.0] {
m.update(t, &p, Spo2Quality::Good);
assert!(!m.measuring());
assert_eq!(m.reading(), None);
}
// The first manual cycle completes even though automatic mode is OFF.
m.measure_now(3601.0, &p, Spo2Quality::Good);
assert!(m.measuring());
m.update(3621.0, &p, Spo2Quality::Good);
assert_eq!(m.reading(), Some(NibpReading { systolic: 118, diastolic: 74 }));
m.update(4400.0, &p, Spo2Quality::Good);
assert!(!m.measuring());
// Enabling Auto starts the next cycle if the selected interval elapsed.
let auto = Parameters { nibp_auto_measurement: true, ..p };
m.update(4400.01, &auto, Spo2Quality::Good);
assert!(m.measuring());
// Disabling Auto again doesn't cancel this running cycle.
m.update(4420.01, &Parameters::default(), Spo2Quality::Good);
assert!(!m.measuring());
}
#[test]
fn turning_auto_on_after_manual_measurement_starts_new_cycle() {
2026-11-12 14:07:59 +01:00
let mut m = NibpMachine::new();
let p = Parameters::default();
m.measure_now(0.0, &p, Spo2Quality::Good);
m.update(20.0, &p, Spo2Quality::Good);
assert!(m.reading().is_some());
assert!(!m.measuring());
// No need to wait five minutes after a manual measurement to enable Auto.
let auto = Parameters { nibp_auto_measurement: true, ..p };
m.update(21.0, &auto, Spo2Quality::Good);
assert!(m.measuring());
}
#[test]
fn enabling_auto_starts_first_measurement_without_preexisting_reading() {
let mut m = NibpMachine::new();
let p = Parameters { nibp_auto_measurement: true, ..Parameters::default() };
m.update(10.0, &p, Spo2Quality::Good);
assert!(m.measuring());
assert_eq!(m.reading(), None);
}
#[test]
fn intervals_and_first_values() {
let mut m = NibpMachine::new();
let p = Parameters { nibp_auto_measurement: true, ..Parameters::default() };
2026-11-12 14:07:59 +01:00
m.update(0.0, &p, Spo2Quality::Good);
assert!(m.measuring());
assert_eq!(m.reading(), None);
assert!((m.cuff_pressure(2.6) - 200.0).abs() < 0.1);
m.update(20.0, &p, Spo2Quality::Good);
assert_eq!(m.reading(), Some(NibpReading { systolic: 118, diastolic: 74 }));
assert!(!m.measuring());
assert!(m.show_new_value(20.1));
assert!(!m.show_new_value(20.6));
assert!(m.show_new_value(25.1));
assert!((m.interval_progress(170.0, 5) - 0.5).abs() < 1e-6);
m.update(319.9, &p, Spo2Quality::Good);
assert!(!m.measuring());
m.update(320.0, &p, Spo2Quality::Good);
assert!(m.measuring());
m.update(340.0, &p, Spo2Quality::Good);
assert!(m.reading().is_some());
let result = m.reading().unwrap();
assert!((result.systolic - p.art_systolic).abs() <= 6);
assert!((result.diastolic - p.art_diastolic).abs() <= 4);
}
#[test]
fn failed_measurement_and_retry_cycle() {
let p = Parameters { nibp_no_reading: true, nibp_auto_measurement: true,
..Parameters::default() };
2026-11-12 14:07:59 +01:00
let mut m = NibpMachine::new();
m.update(0.0, &p, Spo2Quality::Good);
assert!(m.measuring());
assert!((m.cuff_pressure(15.6) - 200.0).abs() < 0.1);
assert!((m.cuff_pressure(64.8) - 200.0/3.0).abs() < 0.1);
assert!((m.cuff_pressure(85.2) - 400.0/3.0).abs() < 0.1);
m.update(120.0, &p, Spo2Quality::Good);
assert!(m.reading().is_none());
}
#[test]
fn cuff_interference_never_improves_quality() {
let p = Parameters { nibp_cuff_on_spo2: true, nibp_auto_measurement: true,
..Parameters::default() };
2026-11-12 14:07:59 +01:00
let mut m = NibpMachine::new();
m.update(0.0, &p, Spo2Quality::Good);
assert_eq!(m.effective_spo2_quality(2.6, &p), Spo2Quality::None);
assert_eq!(m.effective_spo2_quality(10.0, &p), Spo2Quality::Poor);
assert_eq!(m.effective_spo2_quality(19.0, &p), Spo2Quality::Good);
let p = Parameters { spo2_quality: Spo2Quality::Poor, ..p };
assert_eq!(m.effective_spo2_quality(10.0, &p), Spo2Quality::Poor);
}
}
#[cfg(test)]
mod more_tests {
use super::*;
#[test]
fn quality_determines_cycle_duration() {
for (quality, seconds) in [
(Spo2Quality::Good, 20.0),
(Spo2Quality::Adequate, 40.0),
(Spo2Quality::None, 120.0),
] {
let mut machine = NibpMachine::new();
let p = Parameters { nibp_auto_measurement: true, ..Parameters::default() };
2026-11-12 14:07:59 +01:00
machine.update(0.0, &p, quality);
machine.update(seconds - 0.01, &p, quality);
assert!(machine.measuring());
machine.update(seconds, &p, quality);
assert!(!machine.measuring());
assert_eq!(machine.reading().is_some(), quality != Spo2Quality::None);
}
let mut machine = NibpMachine::new();
let p = Parameters { nibp_auto_measurement: true, ..Parameters::default() };
2026-11-12 14:07:59 +01:00
machine.update(0.0, &p, Spo2Quality::Poor);
assert!((60.0..=120.0).contains(&machine.cycle.unwrap().duration));
}
#[test]
fn first_successful_reading_uses_admin_even_after_failed_cycle() {
let mut p = Parameters { nibp_no_reading: true, nibp_auto_measurement: true,
..Parameters::default() };
2026-11-12 14:07:59 +01:00
let mut machine = NibpMachine::new();
machine.update(0.0, &p, Spo2Quality::None);
machine.update(120.0, &p, Spo2Quality::None);
assert!(machine.reading().is_none());
p.nibp_no_reading = false;
machine.measure_now(121.0, &p, Spo2Quality::Good);
machine.update(141.0, &p, Spo2Quality::Good);
assert_eq!(machine.reading(), Some(NibpReading { systolic: 118, diastolic: 74 }));
}
#[test]
fn partial_pressure_uses_diastic_and_systolic_boundaries() {
let p = Parameters { nibp_cuff_on_art: true, nibp_auto_measurement: true,
..Parameters::default() };
2026-11-12 14:07:59 +01:00
let mut machine = NibpMachine::new();
machine.update(0.0, &p, Spo2Quality::Good);
assert_eq!(machine.cuff_zone(2.6, &p), CuffZone::Occluded);
assert_eq!(machine.cuff_zone(10.0, &p), CuffZone::Partial);
assert_eq!(machine.cuff_zone(19.0, &p), CuffZone::Free);
}
}