141 lines
6.5 KiB
Markdown
141 lines
6.5 KiB
Markdown
|
|
# Patient Monitor Simulation (PaMSim) — v0.3.0
|
|||
|
|
|
|||
|
|
A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux.
|
|||
|
|
|
|||
|
|
> **Synthetic training signals only — not for clinical use.** ECG, arterial pressure,
|
|||
|
|
> plethysmography and capnography are schematic mathematical approximations. The
|
|||
|
|
> simulation has no clinical validation and is not a medical device.
|
|||
|
|
|
|||
|
|
## Build and run on Fedora
|
|||
|
|
|
|||
|
|
```bash
|
|||
|
|
sudo dnf install rust cargo gcc pkgconf-pkg-config gtk4-devel
|
|||
|
|
cargo test
|
|||
|
|
cargo run --release
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
Run these commands from the extracted `patient-monitor-simulation` folder.
|
|||
|
|
Window titles show the application version. GTK4 requires a functional graphical
|
|||
|
|
session (e.g., Fedora KDE/Wayland).
|
|||
|
|
|
|||
|
|
## Windows
|
|||
|
|
|
|||
|
|
**Admin:** Controls ECG rhythm and rate; mechanical capture; SpO₂; invasive
|
|||
|
|
arterial pressure, waveform shape and pulse-pressure variation; NIBP; and
|
|||
|
|
capnography. Numeric inputs have bidirectionally linked sliders and text fields.
|
|||
|
|
Each of the five monitor parameters (ECG, SpO₂/pleth, ART, CO₂, NIBP) has its
|
|||
|
|
own **Show on monitor** checkbox.
|
|||
|
|
|
|||
|
|
**Monitor:** Black background; ECG green, pleth yellow, ART red and capnogram
|
|||
|
|
light grey. Waveforms and vital signs disappear together when their respective
|
|||
|
|
visibility checkbox is cleared. Remaining waveform rows expand to use the space.
|
|||
|
|
Hiding a display channel does **not** stop signal generation or physiological
|
|||
|
|
coupling: for example, hiding ECG does not stop ART or pleth pulses. NIBP can
|
|||
|
|
be hidden independently; this also removes its footer.
|
|||
|
|
|
|||
|
|
The monitor can be resized and toggled fullscreen with **F11**; **Esc** exits
|
|||
|
|
fullscreen. On Wayland, move the monitor to the presentation screen before
|
|||
|
|
activating fullscreen. Fullscreen does not lock down the computer.
|
|||
|
|
|
|||
|
|
## ECG and mechanical coupling
|
|||
|
|
|
|||
|
|
- ECG rhythms: sinus, atrial fibrillation, monomorphic ventricular tachycardia,
|
|||
|
|
ventricular fibrillation and asystole.
|
|||
|
|
- Mechanical capture: **1:1**, **2:1**, **3:1**, **None (PEA)**, or deterministic
|
|||
|
|
pseudo-random capture (~65%). PR is derived from conducted QRS events, never
|
|||
|
|
controlled by a pulse-rate slider.
|
|||
|
|
- A captured QRS leads to an ART upstroke after a schematic **120 ms**, and a
|
|||
|
|
peripheral pleth pulse after **300 ms**. Pleth is strongly damped/filtered.
|
|||
|
|
- VF, asystole and PEA suppress mechanical pulses; old samples scroll out of
|
|||
|
|
view. NIBP is a static, separately entered cuff reading.
|
|||
|
|
|
|||
|
|
## Invasive arterial pressure and PPV (new in v0.3)
|
|||
|
|
|
|||
|
|
The arterial waveform has a fixed **0–200 mmHg** display axis, with tick marks
|
|||
|
|
at **0, 50, 100, 150 and 200 mmHg**. Nominal ART systolic and diastolic inputs
|
|||
|
|
are limited to 0–200 mmHg.
|
|||
|
|
|
|||
|
|
**Pulse pressure variation (PPV)** is adjustable from **0% to 60%**, in 1%
|
|||
|
|
increments, via synchronized slider and text field (Admin → Invasive arterial
|
|||
|
|
blood pressure). Its default is **0%** (no respiratory modulation). The
|
|||
|
|
respiratory cycle comes from the same respiratory-rate parameter as the
|
|||
|
|
capnogram. **RR = 0** disables the respiratory modulation (apnea).
|
|||
|
|
|
|||
|
|
The synthetic PPV definition is:
|
|||
|
|
|
|||
|
|
```text
|
|||
|
|
PPV (%) = 100 × (PPmax − PPmin) / ((PPmax + PPmin) / 2)
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
The model applies a sinusoidal variation to **pulse pressure**, sampled for
|
|||
|
|
each mechanically conducted beat. The diastolic baseline remains nominally
|
|||
|
|
fixed, so this is primarily a **beat-to-beat systolic swing**, not an arbitrary
|
|||
|
|
vertical translation of the entire arterial trace. It does not affect ECG,
|
|||
|
|
mechanical capture or pleth amplitude. This is a visual teaching model, not a
|
|||
|
|
validated predictor of fluid responsiveness.
|
|||
|
|
|
|||
|
|
**Example:** ART 120/75 mmHg has nominal pulse pressure 45 mmHg. At PPV 20%,
|
|||
|
|
the ideal pulse-pressure extrema are 40.5 and 49.5 mmHg, corresponding to
|
|||
|
|
systolic peaks of approximately 115.5 and 124.5 mmHg (assuming the diastolic
|
|||
|
|
baseline stays at 75 mmHg). The rendered waveform shape and finite number of
|
|||
|
|
beats per respiratory cycle mean the visible maxima may not reach the ideal
|
|||
|
|
extrema exactly.
|
|||
|
|
|
|||
|
|
The ART sidebar displays the **nominal** systolic/diastolic pressures and MAP,
|
|||
|
|
plus the **configured** PPV percentage when PPV is greater than 0. It does not
|
|||
|
|
measure PPV from sampled arterial data. At very high nominal systolic pressure,
|
|||
|
|
the highest modulated pulses can exceed the 200 mmHg scale; the displayed
|
|||
|
|
curve is then **clipped** at the top, without rescaling the axis.
|
|||
|
|
|
|||
|
|
## Display options (new in v0.3)
|
|||
|
|
|
|||
|
|
The five **Show on monitor** checkboxes affect the presentation only:
|
|||
|
|
|
|||
|
|
| Checkbox | Hidden monitor content |
|
|||
|
|
| --- | --- |
|
|||
|
|
| ECG | ECG waveform, HR and rhythm label |
|
|||
|
|
| Pulse oximetry | Pleth waveform, SpO₂ and PR |
|
|||
|
|
| Invasive arterial blood pressure | ART waveform, pressure values, MAP and PPV label |
|
|||
|
|
| Capnography | CO₂ waveform, EtCO₂ and RR |
|
|||
|
|
| NIBP | Static cuff pressure values and NIBP footer |
|
|||
|
|
|
|||
|
|
Remaining visible waveforms keep their relative order and receive an equal
|
|||
|
|
share of the available area; zero waveform channels is supported.
|
|||
|
|
|
|||
|
|
## Signal implementation
|
|||
|
|
|
|||
|
|
- 100 Hz synthetic signal samples, 10 s retained history, 8 s scrolling trace.
|
|||
|
|
- Cairo draws into the GTK4 `DrawingArea` and scales with the window.
|
|||
|
|
- A conducted QRS records its own respiratory PPV multiplier at event time.
|
|||
|
|
The arterial pulse thus retains the same amplitude throughout the beat.
|
|||
|
|
- Varying PPV does not alter the peripheral pleth pulse or the number of
|
|||
|
|
mechanical pulses.
|
|||
|
|
- Clinical accuracy, dynamic NIBP measurements, alarms, artifacts, calibration,
|
|||
|
|
precise waveform timing, and patient physiology are outside this prototype.
|
|||
|
|
|
|||
|
|
## Project layout
|
|||
|
|
|
|||
|
|
```text
|
|||
|
|
src/
|
|||
|
|
main.rs GTK application entry point
|
|||
|
|
model.rs Parameters, rhythm/capture settings, display flags
|
|||
|
|
simulation.rs QRS-timed mechanical signals, PPV and respiratory synthesis
|
|||
|
|
render.rs Cairo monitor layout, dynamic visibility, fixed ART axis
|
|||
|
|
ui.rs Admin controls and monitor window
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
## Changes since v0.2.2
|
|||
|
|
|
|||
|
|
1. Respiratory PPV with a 0–60% instructor setting, coupled to the simulated
|
|||
|
|
respiratory cycle and applied **per arterial beat**.
|
|||
|
|
2. Five independent display visibility toggles, dynamic waveform row layout,
|
|||
|
|
and independent NIBP-footer hiding.
|
|||
|
|
3. ART axis reduced from **0–250** to **0–200 mmHg**, with inputs adjusted to
|
|||
|
|
the new range.
|
|||
|
|
4. Added regression tests for PPV arithmetic and its effects on ART, for
|
|||
|
|
hiding ECG while retaining mechanical pulses, for active channel selection,
|
|||
|
|
and for arterial-axis normalization.
|
|||
|
|
|
|||
|
|
**Verification:** The archive is generated from these sources. Run `cargo test`
|
|||
|
|
locally to verify the Rust/GTK build; Rust and GTK4 development components
|
|||
|
|
were not available in the environment where this ZIP was prepared.
|