v0.6.10: Instructor shortcuts on the Actions tab

This commit is contained in:
GABRIEL Sebastian 2026-11-13 12:10:38 +01:00
commit 436299c1e4
7 changed files with 606 additions and 102 deletions

View file

@ -1,4 +1,4 @@
# Patient Monitor Simulation (PaMSim) — v0.6.9
# SimPaM — Patient Monitor Simulation v0.6.10
A Rust/GTK4 patient-monitor simulator with two main windows for teaching on Fedora Linux.
@ -6,6 +6,22 @@ A Rust/GTK4 patient-monitor simulator with two main windows for teaching on Fedo
> plethysmography and capnography are schematic mathematical approximations. The
> simulation has no clinical validation and is not a medical device.
## Instructor shortcuts on the Actions tab (v0.6.10)
The **Actions & Occurrences** tab keeps **Chest compressions** (Start/Stop button
and quality selector: Good, Adequate, Poor, Bad) permanently visible **above**
the scripted action selector. These are the same controls as on Direct Mode,
backed by the same state; changes in either tab are reflected in the other.
Chest compressions therefore no longer needs a redundant entry in the action
dropdown. Its clinical simulation behavior is unchanged.
A wide **yellow Defibrillation** shortcut with a **red lightning-bolt icon** is
also always available above the scripted actions. One press produces the
**existing transient ECG defibrillation artifact only**. It does not change
rhythm, ART, EtCO₂ or other physiological parameters, and it does not add a
long-running scripted action. For rhythm conversion and hemodynamic targets,
continue to select **Defibrillation + rhythm change** from the dropdown.
## Actions & Occurrences (v0.6.9)
The Admin window now has two tabs: **Direct Mode** (all original controls) and
@ -780,3 +796,12 @@ manual override of individual parameters, overlapping-action ownership and
an explicit baseline reset. Synthetic defibrillation ECG artifact and scripted
invasive pressure/HR/SpO₂/EtCO₂ progressions are independent of NIBP cuff
settings. Existing Direct Mode and monitor menus are retained.
### v0.6.10 — Persistent CPR controls and defibrillation shortcut
Chest-compression Start/Stop and quality selection are always visible in the
Actions & Occurrences tab above the scripted action dropdown and stay
synchronized with Direct Mode. CPR was removed from the dropdown because the
same controls are now permanently available. A high-contrast yellow one-tap
Defibrillation button with a red lightning symbol triggers only the transient
ECG shock artifact; rhythm conversion remains available as a separate action.