v0.5.4: Chest compressions
This commit is contained in:
parent
fcd8c1146f
commit
483a3c3d61
12 changed files with 1288 additions and 47 deletions
|
|
@ -1,4 +1,4 @@
|
|||
# Patient Monitor Simulation (PaMSim) — v0.5.3
|
||||
# Patient Monitor Simulation (PaMSim) — v0.5.4
|
||||
|
||||
A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux.
|
||||
|
||||
|
|
@ -6,6 +6,47 @@ A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux.
|
|||
> plethysmography and capnography are schematic mathematical approximations. The
|
||||
> simulation has no clinical validation and is not a medical device.
|
||||
|
||||
## Chest compressions (v0.5.4)
|
||||
|
||||
The **Chest compressions** Admin group provides a large **Start Chest Compressions**
|
||||
button (green background). While active it changes to **Stop Chest Compressions**
|
||||
(red background). **Compression quality** can be changed at any time:
|
||||
**Good**, **Adequate** (default), **Poor**, or **Bad**.
|
||||
|
||||
- Compressions are generated independently of the ECG at **90–110/min**, with
|
||||
a new reproducible pseudo-random compression rate and pressure each stroke.
|
||||
**The ECG rhythm and electrical HR setting are not changed.**
|
||||
- Every compression adds movement artifact to the ECG. In a patient with
|
||||
**existing intrinsic arterial perfusion**, the native arterial waveform is
|
||||
preserved but distorted by compression-synchronous pressure artifact.
|
||||
- With **no intrinsic arterial pulse** (e.g., VF, PVT, asystole or PEA),
|
||||
each effective compression generates a broad, blunt arterial pressure wave:
|
||||
|
||||
| Compression quality | Compression-generated ART systolic peak |
|
||||
| --- | --- |
|
||||
| Good | 90 mmHg ±10% (81–99 mmHg) |
|
||||
| Adequate (default) | 70 mmHg ±10% (63–77 mmHg) |
|
||||
| Poor | 50 mmHg, +10% / −50% (25–55 mmHg) |
|
||||
| Bad | No compression-generated arterial pressure; 0–5 mmHg baseline drift |
|
||||
|
||||
During pulseless CPR, **ART SYS** shows the current compression peak,
|
||||
while **DIA/MAP** remain `--` (not estimable from this synthetic pressure).
|
||||
- SpO₂ numeric saturation and the pleth waveform remain visible **only when
|
||||
compression quality is Good**, provided the sensor is connected and not
|
||||
occluded by an NIBP cuff. Their effective signal quality is forced to
|
||||
**Poor (★)**, irrespective of the normal Admin quality setting. The displayed
|
||||
pleth-derived **PR follows the compression rate (90–110/min)**, not the ECG.
|
||||
Adequate, Poor and Bad CPR display **NO READING**; detached sensors display
|
||||
**NO SENSOR**. Compression-induced Poor quality does not schedule the usual
|
||||
intermittent dropout; that resumes when ordinary Poor signal mode returns.
|
||||
- Existing numerical alarms and rhythm alarms remain active. ART SYS limits
|
||||
apply to compression-generated systolic peaks; NIBP scheduling remains unchanged; its cycle duration still depends on
|
||||
effective SpO₂ quality at the start of a measurement.
|
||||
|
||||
These pressure targets are **didactic assumptions**, not validated CPR
|
||||
hemodynamic criteria. The exercise must not be used to judge real compression
|
||||
quality or clinical perfusion.
|
||||
|
||||