v0.5.4: Chest compressions
This commit is contained in:
parent
fcd8c1146f
commit
483a3c3d61
12 changed files with 1288 additions and 47 deletions
|
|
@ -35,7 +35,6 @@ pub fn level(p: &Parameters, sim: &Simulator) -> AlarmLevel {
|
|||
let captured = p.ecg_rhythm.can_generate_pulse()
|
||||
&& p.heart_rate > 0
|
||||
&& p.pulse_conduction != PulseConduction::None;
|
||||
let pr = if captured { sim.pulse_rate() } else { None };
|
||||
|
||||
if p.show_ecg {
|
||||
if p.ecg_rhythm.rhythm_alarm().is_some() {
|
||||
|
|
@ -47,10 +46,10 @@ pub fn level(p: &Parameters, sim: &Simulator) -> AlarmLevel {
|
|||
}
|
||||
|
||||
if p.show_spo2 {
|
||||
let status = p.spo2_status_at_quality(pr, sim.poor_signal_lost(), sim.spo2_quality(p));
|
||||
let status = sim.spo2_status(p);
|
||||
if status != Spo2Status::Available
|
||||
|| outside(p.alarms.spo2, Some(p.spo2))
|
||||
|| outside(p.alarms.pr, pr)
|
||||
|| outside(p.alarms.pr, sim.spo2_pulse_rate(p))
|
||||
{
|
||||
result = AlarmLevel::Standard;
|
||||
}
|
||||
|
|
|
|||
Loading…
Reference in a new issue