v0.5.4: Chest compressions

This commit is contained in:
GABRIEL Sebastian 2026-11-12 15:11:04 +01:00
commit 483a3c3d61
12 changed files with 1288 additions and 47 deletions

View file

@ -0,0 +1,764 @@
diff --git a/Cargo.toml b/Cargo.toml
index debf638..d2a7098 100644
--- a/Cargo.toml
+++ b/Cargo.toml
@@ -1,6 +1,6 @@
[package]
name = "patient-monitor-simulation"
-version = "0.5.3"
+version = "0.5.4"
edition = "2021"
license = "MIT"
description = "Synthetic patient-monitor simulation for teaching (not for clinical use)"
diff --git a/README.de.md b/README.de.md
index 374281f..f7c5ba2 100644
--- a/README.de.md
+++ b/README.de.md
@@ -1,4 +1,4 @@
-# Patient Monitor Simulation (PaMSim) — v0.5.3
+# Patient Monitor Simulation (PaMSim) — v0.5.4
Ein mit Rust und GTK4 entwickelter Patient*innenmonitor-Simulator mit zwei Fenstern für die Lehre unter Fedora Linux.
@@ -6,6 +6,53 @@ Ein mit Rust und GTK4 entwickelter Patient*innenmonitor-Simulator mit zwei Fenst
> EKG, invasive arterielle Druckkurve, Plethysmogramm und Kapnogramm sind schematische mathematische Annäherungen.
> Die Simulation wurde nicht klinisch validiert und ist kein Medizinprodukt.
+## Thoraxkompressionen (v0.5.4)
+
+Im Admin-Bereich **Chest compressions** startet die grüne Schaltfläche
+**Start Chest Compressions** die Simulation. Während aktiver Kompressionen
+wechselt sie zu **Stop Chest Compressions** mit rotem Hintergrund.
+Die **Compression quality** kann jederzeit auf **Good**, **Adequate**
+(Standard), **Poor** oder **Bad** gestellt werden.
+
+- Die Kompressionsfrequenz schwankt zufällig im Bereich **90–110/min**;
+ für jeden Druckstoß werden Frequenz und Druckhöhe neu festgelegt.
+ Der eingestellte EKG-Rhythmus und die elektrische Herzfrequenz bleiben
+ unverändert.
+- Das EKG wird durch kompressionssynchrone Bewegungsartefakte überlagert.
+ Besteht ein **eigener arterieller Kreislauf**, bleibt die ursprüngliche
+ Druckkurve bestehen, wird jedoch durch Kompressionen verzerrt.
+- **Ohne eigenständige arterielle Pulsation** (beispielsweise bei KF, PVT,
+ Asystolie oder PEA) erzeugen wirksame Kompressionen breite, stumpfe
+ arterielle Druckwellen:
+
+ | Kompressionsqualität | Systolischer ART-Spitzendruck |
+ | --- | --- |
+ | Good | 90 mmHg ±10 % (81–99 mmHg) |
+ | Adequate (Standard) | 70 mmHg ±10 % (63–77 mmHg) |
+ | Poor | 50 mmHg, +10 % / −50 % (25–55 mmHg) |
+ | Bad | Kein durch Kompressionen erzeugter Druck; Grundschwankung von 0–5 mmHg |
+
+ Bei fehlender Eigenpulsation zeigt **ART SYS** den Spitzendruck der
+ aktuellen Kompression; **DIA/MAP** bleiben `--`, da sie aus der synthetischen
+ Kurve nicht verlässlich bestimmt werden.
+- Ein SpO₂-Messwert und ein Plethysmogramm werden während laufender
+ Kompressionen **nur bei Qualität Good** angezeigt, vorausgesetzt, der Sensor
+ ist angeschlossen und nicht durch eine NIBP-Manschette okkludiert.
+ Die angezeigte Signalqualität beträgt unabhängig von der Grundeinstellung
+ **Poor (★)**. Die angezeigte **PR folgt der Kompressionsfrequenz (90–110/min)**,
+ nicht der EKG-Frequenz. Bei Adequate, Poor oder Bad erscheint **NO READING**,
+ bei abgezogenem Sensor **NO SENSOR**. Die durch Kompressionen erzwungene
+ Signalqualität Poor führt nicht zu den sonst üblichen periodischen
+ Aussetzern; bei regulärer Grundeinstellung Poor gelten diese nach Ende
+ der Kompressionen wieder.
+- Die bestehenden Rhythmus- und Grenzwertalarme bleiben aktiv. ART-SYS-Grenzen
+ beziehen sich dabei auf die Kompressionsspitzen. Die NIBP-Messintervalle bleiben unverändert; die Dauer eines Messzyklus
+ richtet sich weiterhin nach der wirksamen SpO₂-Signalqualität beim Start.
+
+**Hinweis:** Druckwerte und Signalformen sind didaktisch gewählt und nicht
+klinisch validiert. Aus dieser Simulation darf keine reale Wirksamkeit von
+Reanimationsmaßnahmen abgeleitet werden.
+
## Installation, Kompilierung und Start unter Fedora
```bash
diff --git a/README.md b/README.md
index 20d5943..30ec481 100644
--- a/README.md
+++ b/README.md
@@ -1,4 +1,4 @@
-# Patient Monitor Simulation (PaMSim) — v0.5.3
+# Patient Monitor Simulation (PaMSim) — v0.5.4
A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux.
@@ -6,6 +6,47 @@ A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux.
> plethysmography and capnography are schematic mathematical approximations. The
> simulation has no clinical validation and is not a medical device.
+## Chest compressions (v0.5.4)
+
+The **Chest compressions** Admin group provides a large **Start Chest Compressions**
+button (green background). While active it changes to **Stop Chest Compressions**
+(red background). **Compression quality** can be changed at any time:
+**Good**, **Adequate** (default), **Poor**, or **Bad**.
+
+- Compressions are generated independently of the ECG at **90–110/min**, with
+ a new reproducible pseudo-random compression rate and pressure each stroke.
+ **The ECG rhythm and electrical HR setting are not changed.**
+- Every compression adds movement artifact to the ECG. In a patient with
+ **existing intrinsic arterial perfusion**, the native arterial waveform is
+ preserved but distorted by compression-synchronous pressure artifact.
+- With **no intrinsic arterial pulse** (e.g., VF, PVT, asystole or PEA),
+ each effective compression generates a broad, blunt arterial pressure wave:
+
+ | Compression quality | Compression-generated ART systolic peak |
+ | --- | --- |
+ | Good | 90 mmHg ±10% (81–99 mmHg) |
+ | Adequate (default) | 70 mmHg ±10% (63–77 mmHg) |
+ | Poor | 50 mmHg, +10% / −50% (25–55 mmHg) |
+ | Bad | No compression-generated arterial pressure; 0–5 mmHg baseline drift |
+
+ During pulseless CPR, **ART SYS** shows the current compression peak,
+ while **DIA/MAP** remain `--` (not estimable from this synthetic pressure).
+- SpO₂ numeric saturation and the pleth waveform remain visible **only when
+ compression quality is Good**, provided the sensor is connected and not
+ occluded by an NIBP cuff. Their effective signal quality is forced to
+ **Poor (★)**, irrespective of the normal Admin quality setting. The displayed
+ pleth-derived **PR follows the compression rate (90–110/min)**, not the ECG.
+ Adequate, Poor and Bad CPR display **NO READING**; detached sensors display
+ **NO SENSOR**. Compression-induced Poor quality does not schedule the usual
+ intermittent dropout; that resumes when ordinary Poor signal mode returns.
+- Existing numerical alarms and rhythm alarms remain active. ART SYS limits
+ apply to compression-generated systolic peaks; NIBP scheduling remains unchanged; its cycle duration still depends on
+ effective SpO₂ quality at the start of a measurement.
+
+These pressure targets are **didactic assumptions**, not validated CPR
+hemodynamic criteria. The exercise must not be used to judge real compression
+quality or clinical perfusion.
+
## Build and run on Fedora
```bash
diff --git a/src/alarm.rs b/src/alarm.rs
index d368f20..116b7f4 100644
--- a/src/alarm.rs
+++ b/src/alarm.rs
@@ -35,7 +35,6 @@ pub fn level(p: &Parameters, sim: &Simulator) -> AlarmLevel {
let captured = p.ecg_rhythm.can_generate_pulse()
&& p.heart_rate > 0
&& p.pulse_conduction != PulseConduction::None;
- let pr = if captured { sim.pulse_rate() } else { None };
if p.show_ecg {
if p.ecg_rhythm.rhythm_alarm().is_some() {
@@ -47,10 +46,10 @@ pub fn level(p: &Parameters, sim: &Simulator) -> AlarmLevel {
}
if p.show_spo2 {
- let status = p.spo2_status_at_quality(pr, sim.poor_signal_lost(), sim.spo2_quality(p));
+ let status = sim.spo2_status(p);
if status != Spo2Status::Available
|| outside(p.alarms.spo2, Some(p.spo2))
- || outside(p.alarms.pr, pr)
+ || outside(p.alarms.pr, sim.spo2_pulse_rate(p))
{
result = AlarmLevel::Standard;
}
diff --git a/src/model.rs b/src/model.rs
index 996d6ba..009b231 100644
--- a/src/model.rs
+++ b/src/model.rs
@@ -83,6 +83,29 @@ pub enum CapnoShape {
Obstructive,
}
+/// Instructor-selected efficacy of manual chest compressions.
+/// This affects synthetic pressure and pleth signals, not ECG rhythm or HR.
+#[derive(Clone, Copy, Debug, PartialEq, Eq)]
+pub enum ChestCompressionQuality {
+ Good,
+ Adequate,
+ Poor,
+ Bad,
+}
+
+impl ChestCompressionQuality {
+ /// Approximate compression-generated systolic peak pressure (mmHg).
+ /// None means that compressions generate no measurable arterial pressure.
+ pub fn peak_range(self) -> Option<(f64, f64)> {
+ match self {
+ Self::Good => Some((81.0, 99.0)), // 90 +/- 10%
+ Self::Adequate => Some((63.0, 77.0)), // 70 +/- 10%
+ Self::Poor => Some((25.0, 55.0)), // 50 -50% / +10%
+ Self::Bad => None,
+ }
+ }
+}
+
/// Instructor-selected plethysmography signal quality; separate from the
/// physiological oxygen-saturation setting and mechanical pulse capture.
#[derive(Clone, Copy, Debug, PartialEq, Eq)]
@@ -202,6 +225,8 @@ pub struct Parameters {
pub patient_name: String, // displayed in the monitor header, blank = generic title
pub alarms: AlarmSettings,
pub audible_alarms: bool, // mute only the sound, never the visual alarms
+ pub chest_compressions_active: bool,
+ pub chest_compression_quality: ChestCompressionQuality,
pub ecg_rhythm: EcgRhythm,
pub heart_rate: i32, // bpm, organized electrical rate; not mechanical pulse rate
pub pulse_conduction: PulseConduction,
@@ -277,6 +302,8 @@ impl Default for Parameters {
patient_name: String::new(),
alarms: AlarmSettings::default(),
audible_alarms: true,
+ chest_compressions_active: false,
+ chest_compression_quality: ChestCompressionQuality::Adequate,
ecg_rhythm: EcgRhythm::Sinus,
heart_rate: 75,
pulse_conduction: PulseConduction::OneToOne,
@@ -313,6 +340,17 @@ pub fn mean_arterial_pressure(systolic: i32, diastolic: i32) -> i32 {
mod tests {
use super::*;
+ #[test]
+ fn compression_quality_defaults_to_adequate_and_has_requested_pressure_ranges() {
+ let p = Parameters::default();
+ assert!(!p.chest_compressions_active);
+ assert_eq!(p.chest_compression_quality, ChestCompressionQuality::Adequate);
+ assert_eq!(ChestCompressionQuality::Good.peak_range(), Some((81.0, 99.0)));
+ assert_eq!(ChestCompressionQuality::Adequate.peak_range(), Some((63.0, 77.0)));
+ assert_eq!(ChestCompressionQuality::Poor.peak_range(), Some((25.0, 55.0)));
+ assert_eq!(ChestCompressionQuality::Bad.peak_range(), None);
+ }
+
#[test]
fn mean_pressure_uses_one_third_pulse_pressure() {
assert_eq!(mean_arterial_pressure(120, 75), 90);
diff --git a/src/render.rs b/src/render.rs
index 8cce43d..4053fe1 100644
--- a/src/render.rs
+++ b/src/render.rs
@@ -150,6 +150,7 @@ fn draw_nibp_box(cr: &Context, x: f64, top: f64, width: f64, height: f64,
], right, top, height * 0.65, width * 0.72);
}
+#[cfg(test)]
fn pleth_trace_enabled(p: &Parameters) -> bool {
p.spo2_sensor_attached && p.spo2_quality != Spo2Quality::None
}
@@ -160,9 +161,16 @@ fn spo2_vitals(p: &Parameters, pulse_rate: Option<i32>, signal_lost: bool)
spo2_vitals_at_quality(p, pulse_rate, signal_lost, p.spo2_quality)
}
+#[cfg(test)]
fn spo2_vitals_at_quality(p: &Parameters, pulse_rate: Option<i32>, signal_lost: bool,
quality: Spo2Quality) -> (String, String, String) {
- match p.spo2_status_at_quality(pulse_rate, signal_lost, quality) {
+ spo2_vitals_for_status(p, pulse_rate, quality,
+ p.spo2_status_at_quality(pulse_rate, signal_lost, quality))
+}
+
+fn spo2_vitals_for_status(p: &Parameters, pulse_rate: Option<i32>, quality: Spo2Quality,
+ status: Spo2Status) -> (String, String, String) {
+ match status {
Spo2Status::NoSensor => (
"SpO₂".to_owned(), "NO SENSOR".to_owned(), "PR -- bpm".to_owned()),
Spo2Status::NoReading => (
@@ -196,10 +204,11 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64,
&& p.heart_rate > 0
&& p.pulse_conduction != PulseConduction::None;
let pulse_rate = if has_capture { sim.pulse_rate() } else { None };
+ let spo2_rate = sim.spo2_pulse_rate(p);
let ecg_hr = if p.ecg_rhythm.has_qrs() && p.heart_rate > 0 {
Some(p.heart_rate)
} else { None };
- let spo2_status = p.spo2_status_at_quality(pulse_rate, sim.poor_signal_lost(), sim.spo2_quality(p));
+ let spo2_status = sim.spo2_status(p);
let oxygen = if spo2_status == Spo2Status::Available { Some(p.spo2) } else { None };
let limits: Vec<(&str, AlarmLimits)> = match ch {
@@ -228,8 +237,8 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64,
}
}
Channel::Pleth => {
- let (label, value, info) = spo2_vitals_at_quality(p, pulse_rate,
- sim.poor_signal_lost(), sim.spo2_quality(p));
+ let (label, value, info) = spo2_vitals_for_status(p, spo2_rate,
+ sim.spo2_quality(p), spo2_status);
text(cr, &label, x, top + row_h * 0.24, label_size, color, false);
let technical_alarm = spo2_status != Spo2Status::Available;
let value_size = if technical_alarm {
@@ -239,8 +248,8 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64,
width, color, technical_alarm || alarmed(p.alarms.spo2, oxygen), flash);
if oxygen.is_some() {
draw_alarm_inline(cr, x, info_y, sub_size, width, color,
- "% PR ", &pulse_rate.unwrap_or_default().to_string(), " bpm",
- alarmed(p.alarms.pr, pulse_rate), flash);
+ "% PR ", &spo2_rate.unwrap_or_default().to_string(), " bpm",
+ alarmed(p.alarms.pr, spo2_rate), flash);
} else {
text(cr, &info, x, info_y, sub_size, color, false);
}
@@ -427,9 +436,7 @@ fn draw_trace(cr: &Context, channel: Channel, color: Color,
// Disconnected or absent pleth signal: no curve, including historical pulses.
if matches!(channel, Channel::Pleth)
- && (!pleth_trace_enabled(p)
- || p.spo2_status_at_quality(sim.pulse_rate(), sim.poor_signal_lost(),
- sim.spo2_quality(p)) != Spo2Status::Available)
+ && sim.spo2_status(p) != Spo2Status::Available
{
let _ = cr.restore();
return;
diff --git a/src/simulation.rs b/src/simulation.rs
index c148a30..06fd000 100644
--- a/src/simulation.rs
+++ b/src/simulation.rs
@@ -2,7 +2,8 @@
//! A conducted QRS schedules an arterial pulse and a delayed, smoothed pleth pulse.
use std::collections::VecDeque;
-use crate::model::{ArterialShape, CapnoShape, EcgRhythm, Parameters, PulseConduction, Spo2Quality};
+use crate::model::{ArterialShape, CapnoShape, ChestCompressionQuality, EcgRhythm,
+ Parameters, PulseConduction, Spo2Quality, Spo2Status};
use crate::nibp::{CuffZone, NibpMachine, NibpReading};
const SAMPLE_STEP: f64 = 0.004; // 250 Hz; adequately samples the QRS upstroke
@@ -87,6 +88,91 @@ impl PoorSignalOutages {
}
}
+/// CPR is a separate mechanical clock, independent of intrinsic cardiac rate.
+/// Randomness is sampled once per compression, so peaks and intervals remain
+/// stable during drawing and are reproducible in tests.
+#[derive(Debug)]
+struct ChestCompressions {
+ active: bool,
+ phase: f64,
+ rate_bpm: f64,
+ peak_pressure: f64,
+ quality: ChestCompressionQuality,
+ rng: u64,
+}
+
+impl ChestCompressions {
+ fn new() -> Self {
+ Self { active: false, phase: 0.0, rate_bpm: 100.0,
+ peak_pressure: 0.0, quality: ChestCompressionQuality::Adequate,
+ rng: 0xC0FF_EE12_3456_789A }
+ }
+
+ fn random_unit(&mut self) -> f64 {
+ self.rng = self.rng.wrapping_mul(6_364_136_223_846_793_005)
+ .wrapping_add(1_442_695_040_888_963_407);
+ (self.rng >> 11) as f64 / (1_u64 << 53) as f64
+ }
+
+ fn choose_peak(&mut self) {
+ self.peak_pressure = match self.quality.peak_range() {
+ Some((low, high)) => low + (high - low) * self.random_unit(),
+ None => 0.0,
+ };
+ }
+
+ fn update(&mut self, enabled: bool, quality: ChestCompressionQuality) {
+ if !enabled {
+ self.active = false;
+ self.phase = 0.0;
+ self.peak_pressure = 0.0;
+ return;
+ }
+ if !self.active {
+ self.active = true;
+ self.phase = 0.0;
+ self.rate_bpm = 90.0 + self.random_unit() * 20.0;
+ self.quality = quality;
+ self.choose_peak();
+ } else if self.quality != quality {
+ self.quality = quality;
+ self.choose_peak();
+ }
+ self.phase += SAMPLE_STEP * self.rate_bpm / 60.0;
+ if self.phase >= 1.0 {
+ self.phase = self.phase.fract();
+ self.rate_bpm = 90.0 + self.random_unit() * 20.0;
+ self.choose_peak();
+ }
+ }
+
+ fn pressure_wave(&self) -> f64 {
+ // Rounded, broad compression crest (no narrow physiological upstroke).
+ let rise = smooth_step(self.phase / 0.22);
+ let fall = 1.0 - smooth_step((self.phase - 0.36) / 0.43);
+ (rise * fall).clamp(0.0, 1.0)
+ }
+
+ fn pleth_wave(&self) -> f64 {
+ // A delayed, deliberately weak mechanical pleth pulse.
+ let phase = (self.phase - 0.26).rem_euclid(1.0);
+ smooth_step(phase / 0.27) * (1.0 - smooth_step((phase - 0.27) / 0.62))
+ }
+
+ fn ecg_artifact(&self, time: f64) -> f64 {
+ // Compression-synchronous baseline motion and jagged contact artifact.
+ let wave = self.pressure_wave();
+ 0.56 * (wave - 0.30)
+ + 0.12 * (time * 71.0).sin() * wave
+ + 0.08 * (time * 113.0).sin() * wave
+ }
+}
+
+fn smooth_step(value: f64) -> f64 {
+ let t = value.clamp(0.0, 1.0);
+ t * t * (3.0 - 2.0 * t)
+}
+
pub struct Simulator {
samples: VecDeque<Sample>,
time: f64,
@@ -100,6 +186,7 @@ pub struct Simulator {
previous_conduction: PulseConduction,
previous_heart_rate: i32,
poor_signal_outages: PoorSignalOutages,
+ compressions: ChestCompressions,
nibp: NibpMachine,
art_hold_pressure: Option<f64>,
pending_time: f64,
@@ -120,6 +207,7 @@ impl Simulator {
previous_conduction: params.pulse_conduction,
previous_heart_rate: params.heart_rate,
poor_signal_outages: PoorSignalOutages::new(),
+ compressions: ChestCompressions::new(),
nibp: NibpMachine::new(),
art_hold_pressure: None,
pending_time: 0.0,
@@ -149,7 +237,43 @@ impl Simulator {
pub fn time(&self) -> f64 { self.time }
pub fn spo2_quality(&self, p: &Parameters) -> Spo2Quality {
- self.nibp.effective_spo2_quality(self.time, p)
+ if !p.chest_compressions_active {
+ return self.nibp.effective_spo2_quality(self.time, p);
+ }
+ if p.chest_compression_quality != ChestCompressionQuality::Good {
+ return Spo2Quality::None;
+ }
+ // During effective CPR the pleth signal is Poor regardless of Admin's
+ // baseline quality; an occlusive NIBP cuff can still suppress it.
+ if p.nibp_cuff_on_spo2 {
+ match self.nibp.cuff_zone(self.time, p) {
+ CuffZone::Occluded => return Spo2Quality::None,
+ CuffZone::Partial | CuffZone::Free => {}
+ }
+ }
+ Spo2Quality::Poor
+ }
+
+ /// Display-only pulse rate: under effective CPR the peripheral signal
+ /// follows compressions rather than non-perfusing electrical QRS events.
+ pub fn spo2_pulse_rate(&self, p: &Parameters) -> Option<i32> {
+ if p.chest_compressions_active {
+ (p.chest_compression_quality == ChestCompressionQuality::Good)
+ .then_some(self.compressions.rate_bpm.round() as i32)
+ } else {
+ self.pulse_rate()
+ }
+ }
+
+ pub fn spo2_status(&self, p: &Parameters) -> Spo2Status {
+ if !p.spo2_sensor_attached { return Spo2Status::NoSensor; }
+ if p.chest_compressions_active {
+ return if p.chest_compression_quality == ChestCompressionQuality::Good
+ && self.spo2_quality(p) != Spo2Quality::None
+ { Spo2Status::Available } else { Spo2Status::NoReading };
+ }
+ p.spo2_status_at_quality(self.pulse_rate(), self.poor_signal_lost(),
+ self.spo2_quality(p))
}
pub fn start_nibp_now(&mut self, p: &Parameters) {
@@ -161,7 +285,7 @@ impl Simulator {
if !p.spo2_sensor_attached || self.poor_signal_outages.active {
Spo2Quality::None
} else {
- p.spo2_quality
+ self.spo2_quality(p)
}
}
@@ -169,6 +293,11 @@ impl Simulator {
pub fn displayed_art_pressures(&self, p: &Parameters, has_capture: bool)
-> (Option<i32>, Option<i32>, Option<i32>) {
if !has_capture {
+ // During pulseless CPR the upper ART number reflects the peak
+ // compression pressure; DIA/MAP remain intentionally unassessed.
+ if self.compressions.active && p.chest_compression_quality != ChestCompressionQuality::Bad {
+ return (Some(self.compressions.peak_pressure.round() as i32), None, None);
+ }
return (self.measured_art_pressure(), None, None);
}
if p.nibp_cuff_on_art {
@@ -219,8 +348,11 @@ impl Simulator {
fn step(&mut self, params: &Parameters) {
self.time += SAMPLE_STEP;
+ self.compressions.update(params.chest_compressions_active,
+ params.chest_compression_quality);
self.poor_signal_outages.update(self.time,
- params.spo2_quality == Spo2Quality::Poor && params.spo2_sensor_attached);
+ !params.chest_compressions_active && params.spo2_quality == Spo2Quality::Poor
+ && params.spo2_sensor_attached);
// Snapshot the unoccluded sensor quality at the start of a cuff cycle.
// Cuff-induced signal loss during that cycle must not change its duration.
let start_quality = self.nibp_start_quality(params);
@@ -289,8 +421,25 @@ impl Simulator {
self.rate_qrs.pop_front();
}
- let ecg = ecg_amplitude(self.ecg_phase, self.time, params.ecg_rhythm, params.heart_rate);
- let (normal_art, pleth_target) = self.mechanical_signals(params);
+ let mut ecg = ecg_amplitude(self.ecg_phase, self.time, params.ecg_rhythm, params.heart_rate);
+ let (mut normal_art, mut pleth_target) = self.mechanical_signals(params);
+ if self.compressions.active {
+ ecg += self.compressions.ecg_artifact(self.time);
+ let perfusing = params.ecg_rhythm.can_generate_pulse()
+ && params.pulse_conduction != PulseConduction::None && params.heart_rate > 0;
+ let wave = self.compressions.pressure_wave();
+ if perfusing {
+ // Preserve the patient's intrinsic pressure, with superimposed
+ // compression-synchronous artifact even during bad CPR.
+ normal_art = (normal_art + 22.0 * (wave - 0.32)).clamp(0.0, 250.0);
+ } else if self.compressions.peak_pressure > 0.0 {
+ let baseline = pulseless_arterial_drift(self.time);
+ normal_art = baseline + (self.compressions.peak_pressure - baseline) * wave;
+ }
+ pleth_target = if params.chest_compression_quality == ChestCompressionQuality::Good {
+ 0.85 * self.compressions.pleth_wave()
+ } else { 0.0 };
+ }
let art = self.art_with_cuff(normal_art, params);
let smoothing = 1.0 - (-SAMPLE_STEP / PLETH_FILTER_TAU).exp();
self.filtered_pleth += smoothing * (pleth_target - self.filtered_pleth);
@@ -301,9 +450,7 @@ impl Simulator {
};
let pleth_quality = self.spo2_quality(params);
- let pleth_valid = params.spo2_sensor_attached
- && pleth_quality != Spo2Quality::None
- && !self.poor_signal_outages.active;
+ let pleth_valid = self.spo2_status(params) == Spo2Status::Available;
self.samples.push_back(Sample {
time: self.time, ecg, pleth, pleth_valid, pleth_quality, art, co2,
});
@@ -313,9 +460,10 @@ impl Simulator {
}
fn art_with_cuff(&mut self, normal_art: f64, params: &Parameters) -> f64 {
- if !params.nibp_cuff_on_art || !params.ecg_rhythm.can_generate_pulse()
- || params.pulse_conduction == PulseConduction::None || params.heart_rate <= 0
- {
+ let native_pulse = params.ecg_rhythm.can_generate_pulse()
+ && params.pulse_conduction != PulseConduction::None && params.heart_rate > 0;
+ let compression_pulse = self.compressions.active && self.compressions.peak_pressure > 0.0;
+ if !params.nibp_cuff_on_art || !(native_pulse || compression_pulse) {
self.art_hold_pressure = None;
return normal_art;
}
@@ -545,6 +693,129 @@ mod tests {
sim
}
+ #[test]
+ fn compression_rate_varies_only_between_90_and_110_bpm() {
+ let mut cpr = ChestCompressions::new();
+ let mut observed = Vec::new();
+ for _ in 0..(25.0 / SAMPLE_STEP) as usize {
+ let previous = cpr.phase;
+ cpr.update(true, ChestCompressionQuality::Good);
+ assert!((90.0..=110.0).contains(&cpr.rate_bpm));
+ if cpr.phase < previous { observed.push(cpr.rate_bpm); }
+ }
+ assert!(observed.len() >= 30);
+ assert!(observed.iter().any(|rate| (rate - observed[0]).abs() > 1.0));
+ cpr.update(false, ChestCompressionQuality::Good);
+ assert!(!cpr.active);
+ assert_eq!(cpr.peak_pressure, 0.0);
+ }
+
+ #[test]
+ fn compressions_generate_requested_pulseless_arterial_pressure_by_quality() {
+ for (quality, limits) in [
+ (ChestCompressionQuality::Good, Some((81.0, 99.0))),
+ (ChestCompressionQuality::Adequate, Some((63.0, 77.0))),
+ (ChestCompressionQuality::Poor, Some((25.0, 55.0))),
+ (ChestCompressionQuality::Bad, None),
+ ] {
+ let p = Parameters { ecg_rhythm: EcgRhythm::VentricularFibrillation,
+ chest_compressions_active: true, chest_compression_quality: quality,
+ ..Parameters::default() };
+ let mut sim = Simulator::new(&p);
+ for _ in 0..(2.0 / SAMPLE_STEP) as usize { sim.step(&p); }
+ assert_eq!(sim.pulse_rate(), None, "no intrinsic QRS pulse in VF");
+ let recent: Vec<_> = sim.samples.iter().rev().take(500).collect();
+ let peak = recent.iter().map(|s| s.art).fold(f64::NEG_INFINITY, f64::max);
+ let (sys, dia, map) = sim.displayed_art_pressures(&p, false);
+ assert_eq!((dia, map), (None, None));
+ if let Some((low, high)) = limits {
+ assert!(peak >= low - 1.0 && peak <= high + 1.0,
+ "{quality:?}: waveform peak {peak}");
+ assert!(sys.is_some_and(|v| (low - 1.0..=high + 1.0).contains(&f64::from(v))));
+ } else {
+ assert!(peak <= 5.0, "bad CPR must not create a pulse");
+ assert!(sys.is_some_and(|v| (0..=5).contains(&v)));
+ }
+ }
+ }
+
+ #[test]
+ fn good_cpr_can_create_poor_pleth_in_vf_despite_admin_no_quality() {
+ let p = Parameters { ecg_rhythm: EcgRhythm::VentricularFibrillation,
+ spo2_quality: Spo2Quality::None,
+ chest_compressions_active: true,
+ chest_compression_quality: ChestCompressionQuality::Good,
+ ..Parameters::default() };
+ let mut sim = Simulator::new(&p);
+ for _ in 0..400 { sim.step(&p); }
+ assert_eq!(sim.spo2_quality(&p), Spo2Quality::Poor);
+ assert_eq!(sim.spo2_status(&p), Spo2Status::Available);
+ assert!(sim.spo2_pulse_rate(&p).is_some_and(|v| (90..=110).contains(&v)));
+ assert!(sim.samples.iter().rev().take(400).any(|s| s.pleth > 0.05 && s.pleth_valid));
+ assert!(sim.samples.iter().rev().take(400).all(|s| s.pleth_quality == Spo2Quality::Poor));
+ }
+
+ #[test]
+ fn only_good_cpr_shows_pleth_and_sensor_disconnect_takes_precedence() {
+ for quality in [ChestCompressionQuality::Adequate,
+ ChestCompressionQuality::Poor, ChestCompressionQuality::Bad] {
+ let p = Parameters { chest_compressions_active: true,
+ chest_compression_quality: quality, ..Parameters::default() };
+ let mut sim = Simulator::new(&p);
+ sim.step(&p);
+ assert_eq!(sim.spo2_status(&p), Spo2Status::NoReading);
+ assert_eq!(sim.spo2_pulse_rate(&p), None);
+ assert!(!sim.samples.back().unwrap().pleth_valid);
+ }
+ let mut p = Parameters { chest_compressions_active: true,
+ chest_compression_quality: ChestCompressionQuality::Good, ..Parameters::default() };
+ let mut sim = Simulator::new(&p);
+ p.spo2_sensor_attached = false;
+ sim.step(&p);
+ assert_eq!(sim.spo2_status(&p), Spo2Status::NoSensor);
+ assert!(!sim.samples.back().unwrap().pleth_valid);
+ }
+
+ #[test]
+ fn compressions_distort_ecg_and_preserve_intrinsic_pulses_in_sinus() {
+ let normal = Parameters::default();
+ let with_cpr = Parameters { chest_compressions_active: true,
+ chest_compression_quality: ChestCompressionQuality::Adequate,
+ ..Parameters::default() };
+ let mut base = Simulator::new(&normal);
+ let mut cpr = Simulator::new(&with_cpr);
+ let mut ecg_distortion = false;
+ let mut art_distortion = false;
+ for _ in 0..500 {
+ base.step(&normal);
+ cpr.step(&with_cpr);
+ let native = base.samples.back().unwrap();
+ let compressed = cpr.samples.back().unwrap();
+ ecg_distortion |= (compressed.ecg - native.ecg).abs() > 0.1;
+ art_distortion |= (compressed.art - native.art).abs() > 5.0;
+ }
+ assert!(ecg_distortion);
+ assert!(art_distortion);
+ assert!(cpr.samples.iter().rev().take(500).any(|s| s.art > 60.0));
+ assert_eq!(cpr.pulse_rate(), Some(75), "CPR must not change underlying HR/PR capture");
+ }
+
+ #[test]
+ fn stopping_compressions_restores_pulseless_drift_and_normal_pleth_rules() {
+ let mut p = Parameters { ecg_rhythm: EcgRhythm::Asystole,
+ chest_compressions_active: true,
+ chest_compression_quality: ChestCompressionQuality::Good,
+ ..Parameters::default() };
+ let mut sim = Simulator::new(&p);
+ assert_eq!(sim.spo2_status(&p), Spo2Status::Available);
+ p.chest_compressions_active = false;
+ sim.step(&p);
+ assert!((0.0..=5.0).contains(&sim.samples.back().unwrap().art));
+ assert_eq!(sim.spo2_status(&p), Spo2Status::NoReading);
+ assert!(!sim.samples.back().unwrap().pleth_valid);
+ assert_eq!(sim.spo2_pulse_rate(&p), None);
+ }
+
#[test]
fn signals_remain_in_expected_ranges() {
let p = Parameters::default();
diff --git a/src/ui.rs b/src/ui.rs
index 7e6fd0a..ffb8579 100644
--- a/src/ui.rs
+++ b/src/ui.rs
@@ -9,7 +9,8 @@ use gtk::prelude::*;
use gtk::{Application, ApplicationWindow, Orientation};
use crate::alarm::{self, AlarmAudio};
-use crate::model::{AlarmLimits, AlarmSettings, ArterialShape, CapnoShape, EcgRhythm, Parameters, PulseConduction, Spo2Quality};
+use crate::model::{AlarmLimits, AlarmSettings, ArterialShape, CapnoShape,
+ ChestCompressionQuality, EcgRhythm, Parameters, PulseConduction, Spo2Quality};
use crate::render;
use crate::simulation::Simulator;
@@ -186,6 +187,60 @@ fn create_admin(app: &Application, params: SharedParams,
patient_row.append(&name_entry);
patient.append(&patient_row);
+ // Resuscitation controls are deliberately near the top of the Admin panel.
+ // CSS sets the *button background*, not just its text color.
+ if let Some(display) = gdk::Display::default() {
+ let provider = gtk::CssProvider::new();
+ provider.load_from_data(
+ "button.cpr-start { background-image: none; background-color: #158742; color: #ffffff; font-weight: bold; }
+ button.cpr-stop { background-image: none; background-color: #c53035; color: #ffffff; font-weight: bold; }"
+ );
+ gtk::style_context_add_provider_for_display(
+ &display, &provider, gtk::STYLE_PROVIDER_PRIORITY_APPLICATION);
+ }
+ let cpr = group(&controls, "Chest compressions", None);
+ let compression_button = gtk::Button::with_label("Start Chest Compressions");
+ compression_button.set_hexpand(true);
+ compression_button.add_css_class("cpr-start");
+ compression_button.connect_clicked({
+ let params = params.clone();
+ move |button| {
+ let mut p = params.borrow_mut();
+ p.chest_compressions_active = !p.chest_compressions_active;
+ if p.chest_compressions_active {
+ button.set_label("Stop Chest Compressions");
+ button.remove_css_class("cpr-start");
+ button.add_css_class("cpr-stop");
+ } else {
+ button.set_label("Start Chest Compressions");
+ button.remove_css_class("cpr-stop");
+ button.add_css_class("cpr-start");
+ }
+ }
+ });
+ cpr.append(&compression_button);
+ let _quality = add_dropdown_at(&cpr, "Compression quality",
+ &["Good", "Adequate", "Poor", "Bad"], 1, params.clone(), |p, selected| {
+ p.chest_compression_quality = match selected {
+ 0 => ChestCompressionQuality::Good,
+ 2 => ChestCompressionQuality::Poor,
+ 3 => ChestCompressionQuality::Bad,
+ _ => ChestCompressionQuality::Adequate,
+ };
+ });
+ let cpr_hint = gtk::Label::new(Some(
+ "CPR: 90–110 compressions/min. ECG is distorted; ART receives compression waves. "
+ ));
+ cpr_hint.set_xalign(0.0);
+ cpr_hint.set_wrap(true);
+ cpr.append(&cpr_hint);
+ let cpr_hint2 = gtk::Label::new(Some(
+ "Only Good compressions generate a Poor-quality SpO₂/pleth signal (if the sensor is attached)."
+ ));
+ cpr_hint2.set_xalign(0.0);
+ cpr_hint2.set_wrap(true);
+ cpr.append(&cpr_hint2);
+
let ecg = group(&controls, "ECG", Some(ECG_GREEN));
add_visibility(&ecg, params.borrow().show_ecg, params.clone(), |p, show| p.show_ecg = show);
let rhythm_dropdown = add_dropdown_at(&ecg, "ECG rhythm", &[