This commit is contained in:
GABRIEL Sebastian 2026-11-12 19:31:05 +01:00
commit 54012ab960
9 changed files with 1337 additions and 336 deletions

View file

@ -438,7 +438,7 @@ dependencies = [
[[package]]
name = "patient-monitor-simulation"
version = "0.6.1"
version = "0.6.3"
dependencies = [
"gtk4",
]

View file

@ -1,6 +1,6 @@
[package]
name = "patient-monitor-simulation"
version = "0.6.1"
version = "0.6.3"
edition = "2021"
license = "MIT"
description = "Synthetic patient-monitor simulation for teaching (not for clinical use)"

View file

@ -73,6 +73,19 @@ eine bereits laufende Messung nicht abgebrochen. **Measure now** funktioniert
auch bei ausgeschalteter Automatik. Dann bleibt die Intervallanzeige leer
und der Monitor zeigt `AUTO OFF`.
### Horizontale Matrix für Alarmgrenzen (v0.6.3)
Alle fünf Touchmenüs des Monitors verwenden dieselbe kompakte Matrix.
Jeder Parameter belegt eine Zeile (bei ART: **SYS**, **MAP**, **DIA**,
**PPV**); die **untere (↓)** und **obere (↑)** Alarmgrenze stehen
nebeneinander. Die Schaltflächen jedes Grenzwerts sind von links nach
rechts **+ · Wert · − · OFF/ON** angeordnet. Die Schaltfläche zum
Deaktivieren liegt unmittelbar rechts von Minus. Größe, Gestaltung,
Schrittweite, Wiederherstellung des letzten Werts sowie Apply/Cancel
bleiben erhalten. Bei Platzmangel lässt sich die Matrix scrollen, während
Apply und Cancel zugänglich bleiben. Andere Einstellungen bleiben dem
Admin-Fenster vorbehalten.
## Thoraxkompressionen (v0.5.4)
Im Admin-Bereich **Chest compressions** startet die grüne Schaltfläche

View file

@ -26,80 +26,63 @@ vierten Feldes; die gesamte untere Wertezeile bleibt bestehen.
Beim Ausblenden anderer Parameter werden die verbleibenden Kurvenzeilen wie
bisher dynamisch verteilt.
## EKG-Bedienung direkt am Monitor (v0.5.9)
## Touch-Bedienung am Monitor: ausschließlich Alarmgrenzen (v0.6.1)
Durch Berühren oder Anklicken der **EKG-Zeile** öffnet sich ein eigenes
Einstellfenster mit **hellgrauer Schrift auf schwarzem Hintergrund**. Die gesamte
EKG-Zeile ist aktiv, sowohl die Kurve links (75 %) als auch das numerische
Herzfrequenzfeld rechts (25 %). Die Bedienung ist auch im Vollbildmodus möglich.
Bei ausgeblendetem EKG ist die Interaktionsfläche deaktiviert.
Durch Berühren oder Anklicken der **Kurve oder des numerischen Wertefeldes**
von EKG, SpO₂, ART oder CO₂ öffnet sich das entsprechende Alarmmenü. Bei
NIBP ist das **rechte Viertel der untersten Wertezeile** aktiv. Die übrigen
drei Wertefelder der untersten Zeile bleiben vorerst ohne Touch-Funktion.
Die Menüs funktionieren auch im Vollbildmodus und verwenden **schwarzen
Hintergrund, sehr hellgraue Schrift sowie 0,8 Pixel breite Begrenzungs-
und Trennlinien** wie der Hauptmonitor.
Im Einstellfenster stehen folgende Optionen zur Verfügung:
**Am Monitor können ausschließlich Alarmgrenzen eingestellt werden.**
Für jede untere und obere Alarmgrenze stehen große **−/+**-Tasten sowie
separate **ON/OFF**-Tasten zur Verfügung. Nicht gesetzte Grenzwerte sind
deaktiviert. Ein unterer Grenzwert darf den oberen nicht überschreiten.
Eine Bildschirmtastatur ist nicht erforderlich.
- **ECG lead:** I, II (Voreinstellung), III, aVR, aVL, aVF und V1–V6. Nach
**Apply** ändert sich die Ableitungsbezeichnung im Monitor sowie die
schematische Polarität/Amplitude der Kurve. Es handelt sich **nicht** um
eine klinisch validierte 12-Kanal-EKG-Ableitung. Frequenz, QRS-Zeitpunkte
und mechanische Pulskopplung bleiben unverändert.
- **HR alarm limits:** unabhängig einstellbare untere (↓) und obere (↑)
Herzfrequenzgrenze in /min. Große Tasten **− / +** ändern den jeweiligen
Grenzwert in **5er-Schritten** zwischen 0 und 240. Mit **OFF** lässt sich
jede Grenze einzeln deaktivieren; **ON** aktiviert den vorherigen Wert
erneut (bei anfänglich nicht gesetzten Werten 60 bzw. 100 /min).
Die untere Grenze darf die obere nicht überschreiten.
- **Apply** übernimmt beide Alarmgrenzen und die Ableitung gemeinsam;
**Cancel** oder **Esc** verwirft die noch nicht übernommenen Eingaben.
Die Bedienelemente sind ohne Tastatur verwendbar. Schmale hellgraue
Begrenzungslinien und Trennlinien orientieren sich an der Gestaltung des
Monitors; die EKG-spezifische grüne Textfarbe wird hier nicht verwendet.
Die Einstellungen werden mit der Admin-Oberfläche synchronisiert. Eine am
Monitor geänderte Alarmgrenze schaltet die Alarmvoreinstellung auf **Custom**.
Auch in der Admin-Oberfläche ist die EKG-Ableitung auswählbar. Die anderen
Monitorparameter besitzen ab v0.6.0 ebenfalls berührungsempfindliche Menüs.
## Weitere Touch-Menüs am Monitor (v0.6.0)
Ein Tipp auf die **Kurve oder die numerischen Werte** von SpO₂, ART oder CO₂
öffnet das zugehörige Einstellfenster. Für NIBP ist das **rechte Viertel der
untersten Messwertzeile** aktiv. Die Felder CO/CI, SVRI/GEDI/ELWI und das
unbelegte dritte Feld erhalten noch keine Touch-Bedienung. Alle Menüs
verwenden das Design des EKG-Menüs: **schwarzer Hintergrund, hellgraue Schrift
und 0,8 Pixel breite Trennlinien**. Eine Bildschirmtastatur ist nicht nötig.
| Bereich | Alarmgrenzen | Weitere Einstellungen |
| Monitorbereich | Einstellbare Alarmgrenzen | Schrittweite |
| --- | --- | --- |
| SpO₂ | SpO₂, Pulsfrequenz (PR) | Signalqualität, Sensor angeschlossen/nicht angeschlossen |
| ART | SYS, MAP, DIA, PPV | Form der arteriellen Druckkurve |
| CO₂ | EtCO₂, Atemfrequenz (RR) | Normales oder obstruktives Kapnogramm |
| NIBP | SYS, MAP, DIA | Intervall 1/3/5/10/20/30/60 min, Auto ON/OFF, Messausfall, Manschettenlokalisation und **Measure now** |
| EKG | Herzfrequenz (HR) | 5/min |
| SpO₂ | SpO₂; Pulsfrequenz (PR) | 1 % SpO₂; 5/min PR |
| ART | SYS; MAP; DIA; PPV | 5 mmHg Druck; 1 % PPV |
| CO₂ | EtCO₂; Atemfrequenz (RR) | 1 mmHg EtCO₂; 1/min RR |
| NIBP | SYS; MAP; DIA | 5 mmHg |
Die einzelnen unteren und oberen Alarmgrenzen werden mit großen **−/+**-
und **ON/OFF**-Tasten verändert. Die Schrittweiten betragen 5 /min bei PR,
1 % bei SpO₂ und PPV, 5 mmHg bei ART/NIBP, 1 mmHg bei EtCO₂ und
1 /min bei der Atemfrequenz. Eine untere Grenze darf nicht höher liegen
als die obere.
**Apply** übernimmt die Alarmgrenzen und synchronisiert das Admin-Fenster.
Bei manueller Änderung wechselt das Alarm-Preset zu **Custom**. Mit
**Cancel** oder **Esc** werden nicht übernommene Änderungen verworfen.
Mit **Apply** werden die Änderungen übernommen und zugleich die Admin-
Oberfläche aktualisiert; eine geänderte Alarmgrenze setzt das Preset auf
**Custom**. **Cancel** verwirft die Eingaben, **Esc** schließt das Fenster.
Die Schaltfläche **Measure now** führt dagegen eine sofortige NIBP-Messung
mit den *bereits übernommenen* Einstellungen aus. Änderungen für diese
Messung müssen daher zuerst mit **Apply** bestätigt werden.
Die Auswahl der EKG-Ableitung, SpO₂-Signalqualität und Sensorverbindung,
der arteriellen Kurvenform, der Kapnogrammform sowie **sämtliche NIBP-
Messfunktionen** sind ausschließlich im **Admin-Fenster** verfügbar. Dazu
zählen Messintervall, automatische Messung, **Measure now**, simulierter
Messausfall und Manschettenlokalisation. Diese Parameter können über die
Alarmmenüs am Monitor nicht verändert werden.
### NIBP beim Programmstart
Die **automatische NIBP-Messung ist beim Start ausgeschaltet**. Anfangs
zeigt der Monitor `---/---` (MAP `---`); es wird keine Messung durchgeführt.
Erst **Measure now** oder das Aktivieren von **Automatic measurement**
im NIBP-Touch-Menü (alternativ im Admin-Fenster) startet eine erste Messung.
Wird Auto eingeschaltet, beginnt der erste Zyklus sofort; danach wird das
eingestellte Intervall jeweils ab Ende der letzten Messung gezählt.
Das Ausschalten von Auto verhindert neue automatische Messungen, bricht
einen bereits begonnenen Zyklus jedoch nicht ab. **Measure now** bleibt
bei ausgeschalteter Automatik nutzbar, solange keine Messung läuft.
Bei Auto OFF ist der Intervallbalken leer und `AUTO OFF` wird angezeigt.
zeigt der Monitor `---/---` (MAP `---`); es findet keine Messung statt.
Die erste Messung wird über **Measure now** im Admin-Fenster oder durch
Aktivieren von **Automatic NIBP measurement** ausgelöst. Beim Einschalten
von Auto beginnt sofort ein Messzyklus; das Intervall zählt anschließend
jeweils ab Ende der vorherigen Messung. Beim Ausschalten von Auto wird
eine bereits laufende Messung nicht abgebrochen. **Measure now** funktioniert
auch bei ausgeschalteter Automatik. Dann bleibt die Intervallanzeige leer
und der Monitor zeigt `AUTO OFF`.
### Anordnung der ART-Alarmgrenzen (v0.6.2)
Das Touchmenü für die invasive arterielle Druckmessung ordnet **SYS, MAP und
DIA** in drei Spalten an. Die obere Bedienzeile enthält die **oberen (↑)**
Alarmgrenzen, die zweite die **unteren (↓)** Alarmgrenzen. **PPV** folgt unter
SYS mit eigenen oberen und unteren Grenzwerten. Die bisherigen großen
**+ / Wert / − / EIN-AUS**-Schaltflächen und ihre Bedienlogik bleiben erhalten.
Die Gestaltung verwendet weiterhin Schwarz, Hellgrau und schmale Rahmenlinien.
Alle anderen Parametermenüs bleiben unverändert. Alarmverarbeitung und
Voreinstellungen sind von dieser Layoutänderung nicht betroffen.
## Thoraxkompressionen (v0.5.4)

View file

@ -1,20 +1,8 @@
--- README.de.md
+++ README.de.md
@@ -1,4 +1,4 @@
-# Patient Monitor Simulation (PaMSim) — v0.6.0
+# Patient Monitor Simulation (PaMSim) — v0.6.1
-# Patient Monitor Simulation (PaMSim) — v0.6.2
+# Patient Monitor Simulation (PaMSim) — v0.6.3
Ein mit Rust und GTK4 entwickelter Patient*innenmonitor-Simulator mit zwei Fenstern für die Lehre unter Fedora Linux.
@@ -586,3 +558,11 @@
kein NIBP-Messwert vorhanden; der erste Zyklus muss manuell oder durch
Aktivieren der Automatik gestartet werden. Die bisherige NIBP-Messlogik
wird ansonsten unverändert weiterverwendet.
+
+### v0.6.1 – Touch-Menüs ausschließlich für Alarmgrenzen
+
+Alle Touch-Menüs für EKG, SpO₂, ART, CO₂ und NIBP enthalten jetzt nur noch
+untere und obere Alarmgrenzen. EKG-Ableitung, Signal- und Sensoreinstellungen,
+Kurvenformen sowie NIBP-Messfunktionen wurden aus den Monitor-Menüs entfernt
+und bleiben im Admin-Fenster verfügbar. Die Simulationslogik, Alarmprüfung
+und das NIBP-Startverhalten wurden nicht verändert.

View file

@ -1,4 +1,4 @@
# Patient Monitor Simulation (PaMSim) — v0.6.1
# Patient Monitor Simulation (PaMSim) — v0.6.3
A Rust/GTK4 patient-monitor simulator with two main windows for teaching on Fedora Linux.
@ -67,6 +67,18 @@ cycle already in progress. Manual measurement remains possible while Auto
is off. The interval bar is empty and the monitor displays `AUTO OFF`
whenever automatic measurements are disabled.
### Horizontal touchscreen alarm matrix (v0.6.3)
All five monitor touch menus now share a compact horizontal alarm-limit matrix.
Each parameter occupies its own row (for ART: **SYS**, **MAP**, **DIA**,
**PPV**), with **↓ Lower** and **↑ Upper** displayed in adjacent columns.
Within each limit cell, the touch controls are ordered **+ · value · − ·
OFF/ON** (the OFF/ON button is immediately right of minus). The original
large button styling, per-parameter increments, last-value restoration,
optional bounds and Apply/Cancel semantics are unchanged. The matrix scrolls
if necessary while Apply and Cancel remain accessible below it. Other
physiological and NIBP controls remain Admin-only.
## Chest compressions (v0.5.4)
The **Chest compressions** Admin group provides a large **Start Chest Compressions**

View file

@ -122,12 +122,9 @@ fn create_monitor(app: &Application, params: SharedParams,
let p = params.borrow();
render::monitor_hit_test(x, y, canvas.width(), canvas.height(), &p)
};
match touched {
Some(render::TouchChannel::Ecg) => open_ecg_menu(&app, &window,
params.clone(), admin_changed.clone(), monitor_menu.clone()),
Some(channel) => open_module_menu(&app, &window, params.clone(),
admin_changed.clone(), monitor_menu.clone(), channel),
None => (),
if let Some(channel) = touched {
open_module_menu(&app, &window, params.clone(),
admin_changed.clone(), monitor_menu.clone(), channel);
}
}
});
@ -608,7 +605,16 @@ fn install_ecg_menu_style() {
window.ecg-settings button.ecg-apply {
color: #000000; background-color: #e5e9eb; font-weight: bold;
}
window.ecg-settings button.ecg-close { background-color: #171717; }"
window.ecg-settings button.ecg-close { background-color: #171717; }
window.ecg-settings box.alarm-limit-frame {
border: 0.8px solid #6b757d; padding: 12px;
}
window.ecg-settings label.alarm-limit-heading {
font-weight: bold; font-size: 17px;
}
window.ecg-settings label.alarm-limit-column-heading {
font-size: 15px; font-weight: bold;
}"
);
gtk::style_context_add_provider_for_display(
&display, &provider, gtk::STYLE_PROVIDER_PRIORITY_APPLICATION);
@ -632,14 +638,12 @@ fn ecg_menu_divider() -> gtk::DrawingArea {
separator
}
const TOUCH_HR_STEP: i32 = 5;
const MAX_HR_ALARM: i32 = 240;
/// When a limit is OFF, either +/- first restores its previous value (or
/// a sensible initial value). Subsequent presses adjust it by 5 bpm.
fn stepped_hr_limit(current: Option<i32>, last_enabled: i32, direction: i32) -> i32 {
current.map_or(last_enabled, |value| {
(value + TOUCH_HR_STEP * direction).clamp(0, MAX_HR_ALARM)
/// Apply a touchscreen step to an alarm value. When the alarm is disabled,
/// either +/- first restores its last enabled value (unchanged behavior).
fn stepped_alarm_limit(current: Option<i32>, previous: i32,
direction: i32, step: i32, maximum: i32) -> i32 {
current.map_or(previous, |value| {
(value + step * direction).clamp(0, maximum)
})
}
@ -649,200 +653,23 @@ fn show_touch_hr_limit(value: Option<i32>, number: &gtk::Label,
toggle.set_label(if value.is_some() { "OFF" } else { "ON" });
}
/// Large, keyboard-free +/- and ON/OFF controls. Returning a Cell permits
/// Apply to read the draft value without changing the shared configuration.
fn ecg_touch_limit(parent: &gtk::Box, caption: &str,
initial: Option<i32>, default: i32) -> Rc<Cell<Option<i32>>> {
let state = Rc::new(Cell::new(initial));
let previous = Rc::new(Cell::new(initial.unwrap_or(default)));
let row = gtk::Box::new(Orientation::Horizontal, 10);
let heading = gtk::Label::new(Some(caption));
heading.set_xalign(0.0);
heading.set_width_chars(10);
row.append(&heading);
let minus = gtk::Button::with_label("−");
minus.set_tooltip_text(Some("Decrease alarm limit by 5 bpm"));
minus.set_size_request(54, 50);
row.append(&minus);
let display = gtk::Label::new(None);
display.add_css_class("ecg-limit-value");
display.set_width_chars(5);
display.set_xalign(0.5);
row.append(&display);
let plus = gtk::Button::with_label("+");
plus.set_tooltip_text(Some("Increase alarm limit by 5 bpm"));
plus.set_size_request(54, 50);
row.append(&plus);
let enable_toggle = gtk::Button::new();
enable_toggle.set_tooltip_text(Some("Enable or disable this alarm limit"));
enable_toggle.set_size_request(78, 50);
row.append(&enable_toggle);
show_touch_hr_limit(initial, &display, &enable_toggle);
for (button, direction) in [(minus, -1), (plus, 1)] {
let state = state.clone();
let previous = previous.clone();
let display = display.clone();
let enable_toggle = enable_toggle.clone();
button.connect_clicked(move |_| {
let next = stepped_hr_limit(state.get(), previous.get(), direction);
state.set(Some(next));
previous.set(next);
show_touch_hr_limit(Some(next), &display, &enable_toggle);
});
}
enable_toggle.connect_clicked({
let state = state.clone();
let previous = previous.clone();
let display = display.clone();
move |button| {
let new_value = match state.get() {
Some(value) => {
previous.set(value);
None
}
None => Some(previous.get()),
};
state.set(new_value);
show_touch_hr_limit(new_value, &display, button);
}
});
parent.append(&row);
state
}
/// Displayed only for touches in the ECG row. The monitor window can remain
/// fullscreen. The dialog is modal to that monitor, including on Wayland.
fn open_ecg_menu(app: &Application, monitor: &ApplicationWindow,
params: SharedParams, on_change: AdminChanged,
open_menu: MonitorMenuHandle) {
if let Some(existing) = open_menu.borrow().as_ref().and_then(|weak| weak.upgrade()) {
existing.present();
return;
}
let limits = params.borrow().alarms.hr;
let dialog = gtk::Window::builder()
.application(app)
.title("ECG settings")
.transient_for(monitor)
.modal(true)
.resizable(false)
.default_width(550)
.default_height(345)
.build();
dialog.add_css_class("ecg-settings");
dialog.set_decorated(false);
*open_menu.borrow_mut() = Some(dialog.downgrade());
let content = gtk::Box::new(Orientation::Vertical, 12);
content.add_css_class("ecg-panel");
content.set_margin_top(1);
content.set_margin_bottom(1);
content.set_margin_start(1);
content.set_margin_end(1);
// Inner padding keeps controls away from the thin panel border.
let inner = gtk::Box::new(Orientation::Vertical, 12);
inner.set_margin_top(20);
inner.set_margin_bottom(20);
inner.set_margin_start(20);
inner.set_margin_end(20);
content.append(&inner);
let title = gtk::Label::new(Some("ECG / SETTINGS"));
title.set_xalign(0.0);
title.add_css_class("title-2");
inner.append(&title);
inner.append(&ecg_menu_divider());
let limits_header = gtk::Label::new(Some("HR alarm limits · bpm"));
limits_header.set_xalign(0.0);
inner.append(&limits_header);
let lower = ecg_touch_limit(&inner, "↓ Lower", limits.lower, 60);
let upper = ecg_touch_limit(&inner, "↑ Upper", limits.upper, 100);
let hint = gtk::Label::new(Some(
"+/− adjusts by 5 bpm. OFF disables the limit; ON restores it."
));
hint.set_wrap(true);
hint.set_xalign(0.0);
inner.append(&hint);
inner.append(&ecg_menu_divider());
let error = gtk::Label::new(None);
error.add_css_class("menu-error");
error.set_xalign(0.0);
error.set_wrap(true);
inner.append(&error);
let buttons = gtk::Box::new(Orientation::Horizontal, 12);
buttons.set_halign(gtk::Align::End);
let cancel = gtk::Button::with_label("Cancel");
cancel.add_css_class("ecg-close");
cancel.connect_clicked({
let weak = dialog.downgrade();
move |_| { if let Some(window) = weak.upgrade() { window.close(); } }
});
let apply = gtk::Button::with_label("Apply");
apply.add_css_class("ecg-apply");
apply.connect_clicked({
let weak = dialog.downgrade();
move |_| {
let new_limits = AlarmLimits { lower: lower.get(), upper: upper.get() };
if !new_limits.valid() {
error.set_text("The lower limit must not exceed the upper limit.");
return;
}
let alarm_changed = {
let mut p = params.borrow_mut();
let changed = p.alarms.hr != new_limits;
p.alarms.hr = new_limits;
changed
};
if let Some(callback) = on_change.borrow().as_ref() {
callback(alarm_changed);
}
if let Some(window) = weak.upgrade() { window.close(); }
}
});
buttons.append(&cancel);
buttons.append(&apply);
inner.append(&buttons);
dialog.set_child(Some(&content));
let escape = gtk::EventControllerKey::new();
escape.connect_key_pressed({
let weak = dialog.downgrade();
move |_, key, _, _| {
if key == gdk::Key::Escape {
if let Some(window) = weak.upgrade() { window.close(); }
glib::Propagation::Stop
} else { glib::Propagation::Proceed }
}
});
dialog.add_controller(escape);
dialog.present();
}
#[cfg(test)]
mod ecg_touch_menu_tests {
use super::*;
#[test]
fn touch_step_uses_five_bpm_and_respects_bounds() {
assert_eq!(stepped_hr_limit(Some(60), 60, 1), 65);
assert_eq!(stepped_hr_limit(Some(60), 60, -1), 55);
assert_eq!(stepped_hr_limit(Some(240), 240, 1), 240);
assert_eq!(stepped_hr_limit(Some(0), 0, -1), 0);
fn touch_step_preserves_per_parameter_increment_and_bounds() {
assert_eq!(stepped_alarm_limit(Some(60), 60, 1, 5, 240), 65);
assert_eq!(stepped_alarm_limit(Some(60), 60, -1, 5, 240), 55);
assert_eq!(stepped_alarm_limit(Some(240), 240, 1, 5, 240), 240);
assert_eq!(stepped_alarm_limit(Some(0), 0, -1, 5, 240), 0);
assert_eq!(stepped_alarm_limit(Some(90), 90, 1, 1, 100), 91);
}
#[test]
fn disabled_alarm_reenables_at_last_saved_value() {
assert_eq!(stepped_hr_limit(None, 60, 1), 60);
assert_eq!(stepped_hr_limit(None, 100, -1), 100);
assert_eq!(stepped_alarm_limit(None, 60, 1, 5, 240), 60);
assert_eq!(stepped_alarm_limit(None, 100, -1, 5, 240), 100);
}
#[test]
@ -887,6 +714,9 @@ fn module_alarm_specs(channel: render::TouchChannel, p: &Parameters) -> Vec<Touc
};
}
match channel {
render::TouchChannel::Ecg => {
limits!("HR", "bpm", hr, 240, 5, 60, 100);
}
render::TouchChannel::Spo2 => {
limits!("SpO₂", "%", spo2, 100, 1, 90, 100);
limits!("Pulse rate", "bpm", pr, 240, 5, 50, 120);
@ -906,50 +736,53 @@ fn module_alarm_specs(channel: render::TouchChannel, p: &Parameters) -> Vec<Touc
limits!("NIBP MAP", "mmHg", nibp_map, 260, 5, 60, 100);
limits!("NIBP diastolic", "mmHg", nibp_dia, 260, 5, 40, 100);
}
render::TouchChannel::Ecg => {}
}
specs
}
/// Generic unit-aware limit control with large +/- and ON/OFF touch buttons.
/// Unlike the ECG-only helper, the increment and permitted range are per value.
/// A compact alarm-limit cell: [+] value [−] [OFF/ON]. Its buttons retain
/// the old size/style, step size, last-value restoration and draft semantics.
#[allow(clippy::too_many_arguments)]
fn module_touch_limit(parent: &gtk::Box, caption: &str, initial: Option<i32>,
fallback: i32, step: i32, maximum: i32) -> Rc<Cell<Option<i32>>> {
fn alarm_matrix_cell(initial: Option<i32>, fallback: i32, step: i32,
maximum: i32) -> (gtk::Box, Rc<Cell<Option<i32>>>) {
let state = Rc::new(Cell::new(initial));
let previous = Rc::new(Cell::new(initial.unwrap_or(fallback)));
let row = gtk::Box::new(Orientation::Horizontal, 10);
let caption_label = gtk::Label::new(Some(caption));
caption_label.set_width_chars(10);
caption_label.set_xalign(0.0);
row.append(&caption_label);
let minus = gtk::Button::with_label("−");
minus.set_size_request(54, 50);
let display = gtk::Label::new(None);
display.add_css_class("ecg-limit-value");
display.set_xalign(0.5);
display.set_width_chars(5);
let controls = gtk::Box::new(Orientation::Horizontal, 5);
controls.set_hexpand(true);
controls.set_halign(gtk::Align::Center);
let plus = gtk::Button::with_label("+");
plus.set_size_request(54, 50);
plus.set_tooltip_text(Some("Increase alarm limit"));
let display = gtk::Label::new(None);
display.add_css_class("ecg-limit-value");
display.set_width_chars(5);
display.set_xalign(0.5);
let minus = gtk::Button::with_label("−");
minus.set_size_request(54, 50);
minus.set_tooltip_text(Some("Decrease alarm limit"));
let toggle = gtk::Button::new();
toggle.set_size_request(78, 50);
toggle.set_tooltip_text(Some("Enable or disable this alarm limit"));
show_touch_hr_limit(initial, &display, &toggle);
row.append(&minus);
row.append(&display);
row.append(&plus);
row.append(&toggle);
for (button, direction) in [(minus, -1), (plus, 1)] {
// Requested left-to-right order: plus, value, minus, OFF.
controls.append(&plus);
controls.append(&display);
controls.append(&minus);
controls.append(&toggle);
for (button, direction) in [(plus, 1), (minus, -1)] {
let state = state.clone();
let previous = previous.clone();
let display = display.clone();
let toggle = toggle.clone();
button.connect_clicked(move |_| {
let new_value = state.get().map_or(previous.get(), |current| {
(current + direction * step).clamp(0, maximum)
});
state.set(Some(new_value));
previous.set(new_value);
show_touch_hr_limit(Some(new_value), &display, &toggle);
let next = stepped_alarm_limit(state.get(), previous.get(),
direction, step, maximum);
state.set(Some(next));
previous.set(next);
show_touch_hr_limit(Some(next), &display, &toggle);
});
}
toggle.connect_clicked({
@ -957,16 +790,80 @@ fn module_touch_limit(parent: &gtk::Box, caption: &str, initial: Option<i32>,
let previous = previous.clone();
let display = display.clone();
move |button| {
let new_value = match state.get() {
let next = match state.get() {
Some(value) => { previous.set(value); None }
None => Some(previous.get()),
};
state.set(new_value);
show_touch_hr_limit(new_value, &display, button);
state.set(next);
show_touch_hr_limit(next, &display, button);
}
});
parent.append(&row);
state
(controls, state)
}
/// Short names in the alarm matrix; full labels remain available as tooltips.
fn alarm_matrix_label(name: &str) -> &str {
match name {
"ART systolic" | "NIBP systolic" => "SYS",
"ART MAP" | "NIBP MAP" => "MAP",
"ART diastolic" | "NIBP diastolic" => "DIA",
"Pulse rate" => "PR",
"Respiratory rate" => "RR",
other => other,
}
}
/// Common touchscreen matrix for ECG, SpO2, ART, CO2 and NIBP.
/// Each parameter occupies one horizontal row; lower and upper limits have
/// identical columns and the action order [+] value [−] [OFF/ON].
fn alarm_limit_matrix(specs: Vec<TouchAlarmSpec>,
drafts: &mut Vec<TouchAlarmDraft>) -> gtk::Box {
let frame = gtk::Box::new(Orientation::Vertical, 8);
frame.add_css_class("alarm-limit-frame");
frame.set_hexpand(true);
let heading = gtk::Label::new(Some("Alarm Limits"));
heading.add_css_class("alarm-limit-heading");
heading.set_xalign(0.0);
frame.append(&heading);
let grid = gtk::Grid::new();
grid.set_hexpand(true);
grid.set_column_spacing(8);
grid.set_row_spacing(8);
for (column, text) in [(1, "↓ Lower"), (2, "↑ Upper")] {
let label = gtk::Label::new(Some(text));
label.add_css_class("alarm-limit-column-heading");
label.set_halign(gtk::Align::Center);
grid.attach(&label, column, 0, 1, 1);
}
for (index, spec) in specs.into_iter().enumerate() {
// An empty narrow divider row keeps each parameter visually distinct.
let base = 1 + (index as i32) * 2;
if index > 0 {
grid.attach(&ecg_menu_divider(), 0, base - 1, 3, 1);
}
let label = gtk::Label::new(Some(alarm_matrix_label(spec.name)));
label.set_xalign(0.0);
label.set_tooltip_text(Some(&format!("{} ({})", spec.name, spec.unit)));
label.add_css_class("alarm-limit-heading");
label.set_width_chars(5);
grid.attach(&label, 0, base, 1, 1);
let (lower_controls, lower) = alarm_matrix_cell(spec.limits.lower,
spec.restore_lower, spec.step, spec.maximum);
let (upper_controls, upper) = alarm_matrix_cell(spec.limits.upper,
spec.restore_upper, spec.step, spec.maximum);
grid.attach(&lower_controls, 1, base, 1, 1);
grid.attach(&upper_controls, 2, base, 1, 1);
drafts.push(TouchAlarmDraft {
name: spec.name, lower, upper, apply: spec.apply,
});
}
frame.append(&grid);
frame
}
/// A monitor-side menu may change only alarm limits. All patient and
@ -998,7 +895,7 @@ fn open_module_menu(app: &Application, monitor: &ApplicationWindow,
render::TouchChannel::Art => "ART / SETTINGS",
render::TouchChannel::Capno => "CO₂ / SETTINGS",
render::TouchChannel::Nibp => "NIBP / SETTINGS",
render::TouchChannel::Ecg => return,
render::TouchChannel::Ecg => "ECG / SETTINGS",
};
let dialog = gtk::Window::builder()
.application(app)
@ -1006,8 +903,13 @@ fn open_module_menu(app: &Application, monitor: &ApplicationWindow,
.transient_for(monitor)
.modal(true)
.resizable(true)
.default_width(560)
.default_height(if channel == render::TouchChannel::Art { 720 } else { 610 })
.default_width(800)
.default_height(match channel {
render::TouchChannel::Art => 560,
render::TouchChannel::Nibp => 490,
render::TouchChannel::Ecg => 310,
_ => 420,
})
.build();
dialog.add_css_class("ecg-settings");
dialog.set_decorated(false);
@ -1036,28 +938,22 @@ fn open_module_menu(app: &Application, monitor: &ApplicationWindow,
inner.append(&heading);
inner.append(&ecg_menu_divider());
// Every numeric alarm has two optional bounds, editable without a keyboard.
// A shared horizontal matrix is used in every monitor-side touch menu.
let specs = module_alarm_specs(channel, &current);
let mut alarm_drafts = Vec::new();
for spec in specs {
let label = gtk::Label::new(Some(&format!("{} alarm limits · {}", spec.name, spec.unit)));
label.set_xalign(0.0);
inner.append(&label);
let lower = module_touch_limit(&inner, "↓ Lower", spec.limits.lower,
spec.restore_lower, spec.step, spec.maximum);
let upper = module_touch_limit(&inner, "↑ Upper", spec.limits.upper,
spec.restore_upper, spec.step, spec.maximum);
alarm_drafts.push(TouchAlarmDraft {
name: spec.name, lower, upper, apply: spec.apply,
});
inner.append(&ecg_menu_divider());
}
inner.append(&alarm_limit_matrix(specs, &mut alarm_drafts));
let error = gtk::Label::new(None);
error.set_xalign(0.0);
error.add_css_class("menu-error");
error.set_wrap(true);
inner.append(&error);
// Validation and Apply/Cancel stay fixed when the matrix scrolls.
let footer = gtk::Box::new(Orientation::Vertical, 8);
footer.set_margin_start(20);
footer.set_margin_end(20);
footer.set_margin_top(8);
footer.set_margin_bottom(12);
footer.append(&error);
let buttons = gtk::Box::new(Orientation::Horizontal, 12);
buttons.set_halign(gtk::Align::End);
let cancel = gtk::Button::with_label("Cancel");
@ -1097,7 +993,8 @@ fn open_module_menu(app: &Application, monitor: &ApplicationWindow,
});
buttons.append(&cancel);
buttons.append(&apply);
inner.append(&buttons);
footer.append(&buttons);
content.append(&footer);
dialog.set_child(Some(&content));
let escape = gtk::EventControllerKey::new();
@ -1133,6 +1030,39 @@ mod module_touch_menu_tests {
}
}
#[test]
fn alarm_matrix_order_and_labels() {
let p = Parameters::default();
for (channel, names) in [
(render::TouchChannel::Ecg, vec!["HR"]),
(render::TouchChannel::Spo2, vec!["SpO₂", "PR"]),
(render::TouchChannel::Art, vec!["SYS", "MAP", "DIA", "PPV"]),
(render::TouchChannel::Capno, vec!["EtCO₂", "RR"]),
(render::TouchChannel::Nibp, vec!["SYS", "MAP", "DIA"]),
] {
let specs = module_alarm_specs(channel, &p);
let actual: Vec<_> = specs.iter()
.map(|spec| alarm_matrix_label(spec.name)).collect();
assert_eq!(actual, names);
}
// Same underlying ART alarm setters are retained after rearrangement.
let specs = module_alarm_specs(render::TouchChannel::Art, &p);
let limits = [
AlarmLimits { lower: Some(80), upper: Some(180) },
AlarmLimits { lower: Some(60), upper: Some(100) },
AlarmLimits { lower: None, upper: None },
AlarmLimits { lower: None, upper: Some(10) },
];
let mut alarms = AlarmSettings::default();
for (spec, value) in specs.into_iter().zip(limits.iter().copied()) {
(spec.apply)(&mut alarms, value);
}
assert_eq!(alarms.art_sys, limits[0]);
assert_eq!(alarms.art_map, limits[1]);
assert_eq!(alarms.art_dia, limits[2]);
assert_eq!(alarms.ppv, limits[3]);
}
#[test]
fn touchscreen_applies_only_alarm_limits_and_preserves_other_controls() {
let mut p = Parameters::default();