moce patches

This commit is contained in:
GABRIEL Sebastian 2026-11-13 10:59:24 +01:00
commit 5665d68db0
37 changed files with 1472 additions and 570 deletions

View file

@ -0,0 +1,311 @@
diff --git a/Cargo.toml b/Cargo.toml
index 13195d0..77b0b47 100644
--- a/Cargo.toml
+++ b/Cargo.toml
@@ -1,6 +1,6 @@
[package]
name = "patient-monitor-simulation"
-version = "0.5.6"
+version = "0.5.7"
edition = "2021"
license = "MIT"
description = "Synthetic patient-monitor simulation for teaching (not for clinical use)"
diff --git a/README.de.md b/README.de.md
index 4082c89..0fdf2d0 100644
--- a/README.de.md
+++ b/README.de.md
@@ -1,4 +1,4 @@
-# Patient Monitor Simulation (PaMSim) — v0.5.4
+# Patient Monitor Simulation (PaMSim) — v0.5.7
Ein mit Rust und GTK4 entwickelter Patient*innenmonitor-Simulator mit zwei Fenstern für die Lehre unter Fedora Linux.
@@ -6,6 +6,26 @@ Ein mit Rust und GTK4 entwickelter Patient*innenmonitor-Simulator mit zwei Fenst
> EKG, invasive arterielle Druckkurve, Plethysmogramm und Kapnogramm sind schematische mathematische Annäherungen.
> Die Simulation wurde nicht klinisch validiert und ist kein Medizinprodukt.
+## Monitoraufteilung (v0.5.7)
+
+Der nutzbare Monitorbereich wird in einem festen Verhältnis von **75 % für die
+Kurvenspalte** und **25 % für die numerische Spalte** aufgeteilt. Dies gilt auch
+bei Änderung der Fenstergröße. Die letzte Zeile besteht aus vier gleich breiten
+Wertefeldern:
+
+| Feld 1 (25 %) | Feld 2 (25 %) | Feld 3 (25 %) | Feld 4 (25 %) |
+| --- | --- | --- | --- |
+| CO / CI | SVRI · GEDI · ELWI | *(leer)* | NIBP |
+
+In den ersten beiden Feldern sind ausschließlich die Beschriftungen sichtbar;
+Messwerte und Berechnungen werden erst in einer späteren Version implementiert.
+Das dritte Feld bleibt vollständig leer. Im vierten Feld bleiben die bestehenden
+NIBP-Messwerte, der Manschettendruckbalken, die Fortschrittsanzeige und die
+Alarme erhalten. Wenn NIBP ausgeblendet wird, verschwindet nur der Inhalt des
+vierten Feldes; die gesamte untere Wertezeile bleibt bestehen.
+Beim Ausblenden anderer Parameter werden die verbleibenden Kurvenzeilen wie
+bisher dynamisch verteilt.
+
## Thoraxkompressionen (v0.5.4)
Im Admin-Bereich **Chest compressions** startet die grüne Schaltfläche
@@ -83,11 +103,10 @@ Lange Namen werden an die verfügbare Breite angepasst oder abgeschnitten.
Wird die Sichtbarkeit eines Parameters deaktiviert, verschwinden sowohl seine Kurve als auch die zugehörigen Messwerte.
Die verbleibenden Kurvenbereiche vergrößern sich entsprechend.
Das Ausblenden eines Monitorbereichs unterbricht **nicht** die Signalerzeugung oder physiologische Kopplung: Wird beispielsweise das EKG ausgeblendet, können arterielle und plethysmographische Pulse weiterhin auftreten.
-Für NIBP wird in der linken Kurvenspalte eine **leere Zelle** freigehalten.
-Damit sind die Kurvenbereiche und die numerischen Wertefelder in der rechten Spalte
-in allen Zeilen exakt aufeinander ausgerichtet.
-NIBP kann unabhängig ausgeblendet werden; dabei verschwindet die gesamte NIBP-Zeile
-und die übrigen Zeilen nutzen den frei werdenden Platz.
+Die unterste Zeile enthält vier gleich breite numerische Wertefelder. Das
+vierte Feld für NIBP ist an der rechten Monitorspalte ausgerichtet.
+NIBP kann unabhängig ausgeblendet werden; dabei bleibt die untere Zeile mit
+den drei noch nicht implementierten Messgruppen bestehen.
Das Monitorfenster lässt sich in der Größe verändern.
Mit **F11** wird der Vollbildmodus aktiviert bzw. umgeschaltet, mit **Esc** wird er verlassen.
@@ -479,3 +498,11 @@ Die verzögerte Plethysmographiekurve bei Thoraxkompressionen überlappt nicht m
### v0.5.6 – Persistenz des Pleth-Filters bei Thoraxkompressionen
Die eigentliche Ursache des Testfehlers aus v0.5.5 wurde behoben: Bei pulslosen Rhythmen wurde der Pleth-Tiefpassfilter bislang mit jedem 250-Hz-Abtastwert zurückgesetzt. Während qualitativ guter Thoraxkompressionen bleibt der Filterzustand nun erhalten; QRS-getriggerte mechanische Pulse werden weiterhin verworfen. Nach dem Beenden der Kompressionen bei VF/PVT verschwindet das Pleth-Signal sofort. Ein zusätzlicher Regressionstest deckt PVT ab.
+
+### v0.5.7 – Vier numerische Messgruppen in der unteren Zeile
+
+Feste Aufteilung von 75 % Kurvenspalte und 25 % numerischer Spalte. In der
+untersten Zeile stehen vier gleich breite Bereiche: CO/CI, SVRI/GEDI/ELWI,
+ein vollständig leerer Platzhalter und NIBP. Die ersten beiden Bereiche
+zeigen derzeit nur ihre Bezeichnungen. Wird NIBP ausgeblendet, bleibt die
+untere Zeile bestehen. Das Simulationsverhalten ist unverändert.
diff --git a/README.md b/README.md
index dc19c84..fe6cac3 100644
--- a/README.md
+++ b/README.md
@@ -1,4 +1,4 @@
-# Patient Monitor Simulation (PaMSim) — v0.5.4
+# Patient Monitor Simulation (PaMSim) — v0.5.7
A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux.
@@ -6,6 +6,23 @@ A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux.
> plethysmography and capnography are schematic mathematical approximations. The
> simulation has no clinical validation and is not a medical device.
+## Monitor layout (v0.5.7)
+
+The monitor uses a fixed **3:1 column ratio** over the drawable area:
+**75% waveform column / 25% numeric column**, regardless of window size.
+The last row is reserved for four equal-width numerical measurement groups:
+
+| Group 1 (25%) | Group 2 (25%) | Group 3 (25%) | Group 4 (25%) |
+| --- | --- | --- | --- |
+| CO / CI | SVRI · GEDI · ELWI | *(empty)* | NIBP |
+
+The first two groups currently display only their headings, with no numerical
+values or simulation logic. The third group is completely empty. The fourth
+retains the existing red NIBP readings, cuff gauge, progress bar and alarms.
+The NIBP visibility toggle hides **only the fourth group's content**; the
+bottom measurement row and other three groups remain present. Disabling one
+of the four waveform channels still reflows the remaining rows above it.
+
## Chest compressions (v0.5.4)
The **Chest compressions** Admin group provides a large **Start Chest Compressions**
@@ -80,10 +97,11 @@ Long names are automatically resized or clipped to fit the header.
Waveforms and vital signs disappear together when their respective
visibility checkbox is cleared. Remaining waveform rows expand to use the space.
Hiding a display channel does **not** stop signal generation or physiological
-coupling: for example, hiding ECG does not stop ART or pleth pulses. NIBP occupies a dedicated right-column row with an **empty waveform cell** on the
-left. All waveform rows and their corresponding numeric boxes share the same
-height and horizontal boundaries. NIBP can be hidden independently; its entire
-row is then removed and the remaining rows expand evenly.
+coupling: for example, hiding ECG does not stop ART or pleth pulses.
+The final row is split into four equal-width measurement groups, with **NIBP in
+the fourth group**, aligned beneath the regular numeric column. The first
+three groups are reserved for future measurements. Hiding NIBP only clears
+its own fourth group, without removing the final row.
The monitor can be resized and toggled fullscreen with **F11**; **Esc** exits
fullscreen. On Wayland, move the monitor to the presentation screen before
@@ -236,8 +254,8 @@ can be taught.
## NIBP measurement cycle (v0.5.0)
NIBP is **red**, with a dedicated value box in the **right-hand numeric column**.
-An **empty left-hand waveform cell** occupies the same row, keeping every numeric
-value box horizontally aligned with its waveform region. The previous static
+The bottom measurement row has three placeholder groups to its left, keeping
+NIBP aligned with the standard right-hand numeric column. The previous static
NIBP footer has been removed. In Admin, choose an interval
of **1, 3, 5, 10, 20, 30, or 60 minutes** (default 5). The initial cuff cycle
begins when the simulation starts; subsequent intervals run **from the end of
@@ -366,9 +384,10 @@ The five **Show on monitor** checkboxes affect the presentation only:
| Capnography | CO₂ waveform, EtCO₂ and RR |
| NIBP | Timed cuff-measurement values and red right-column value box |
-Remaining visible waveform rows and the NIBP-only row share an equal
+Remaining visible waveform rows and the bottom measurements row share an equal
portion of the available height and remain aligned across both columns; zero
-waveform channels is supported.
+waveform channels is supported. Hiding NIBP leaves the three future measurement
+placeholders visible.
## ECG morphology correction (v0.3.1)
@@ -500,3 +519,11 @@ The delayed CPR pleth waveform no longer wraps its trailing portion into the nex
### v0.5.6 — CPR pleth filter persistence
Corrects the underlying cause of the v0.5.5 test failure: in pulseless rhythms, the simulation had reset the pleth low-pass filter at every 250 Hz sample, preventing CPR-induced signals from accumulating. The filter now persists during good-quality chest compressions while QRS-triggered mechanical pulses are still cleared. Stopping CPR in VF/PVT immediately restores no reading. Additional regression coverage includes PVT.
+
+### v0.5.7 — Four-group numerical measurement row
+
+The monitor now uses a 75%/25% waveform/numeric column split. The final
+row has four equally sized measurement groups: CO/CI; SVRI/GEDI/ELWI;
+reserved empty; and the unchanged NIBP readout. Only headings are rendered
+in the first two groups; the third has no content. NIBP can be hidden without
+removing the final row. No physiological simulation behavior was modified.
diff --git a/src/render.rs b/src/render.rs
index 4053fe1..cb62a42 100644
--- a/src/render.rs
+++ b/src/render.rs
@@ -35,13 +35,13 @@ pub fn draw(cr: &Context, width: i32, height: i32, p: &Parameters, sim: &Simulat
let header = (h * 0.083).clamp(32.0, 68.0);
let channels = visible_channels(p);
let body_height = (h - header - pad).max(20.0);
- // A single grid governs both columns. NIBP has an empty waveform cell
- // on the left, so all numeric boxes line up with their waveform rows.
- let (row_height, nibp_top) = monitor_rows(header, body_height, channels.len(), p.show_nibp);
- let sidebar = (w * 0.235).clamp(125.0, 370.0).min(w * 0.44);
- let split_x = w - sidebar - pad;
+ // Waveforms occupy three quarters of the drawable width and numeric
+ // values one quarter. The final row is four equal-sized numeric cells.
+ let (row_height, measurements_top) = monitor_rows(header, body_height, channels.len());
+ let (split_x, quarter_width) = monitor_columns(w, pad);
+ let numeric_width = (quarter_width - 2.0 * pad).max(1.0);
let trace_left = pad + 6.0;
- let trace_right = (split_x - pad).max(trace_left + 40.0);
+ let trace_right = (split_x - pad).max(trace_left + 1.0);
let text_scale = (w.min(h * 1.7) / 850.0).clamp(0.65, 1.5);
let patient_title = if p.patient_name.trim().is_empty() {
@@ -72,25 +72,58 @@ pub fn draw(cr: &Context, width: i32, height: i32, p: &Parameters, sim: &Simulat
draw_trace(cr, channel, color, trace_left, trace_right,
top + row_height * 0.25, bottom - row_height * 0.06, p, sim);
draw_vitals(cr, channel, color, split_x + pad,
- top, row_height, sidebar - 2.0 * pad, p, sim);
+ top, row_height, numeric_width, p, sim);
}
- if let Some(top) = nibp_top {
- // Intentionally blank waveform cell to the left of the NIBP box.
- stroke_line(cr, pad, top + row_height, w - pad, top + row_height, MUTED, 0.65);
- draw_nibp_box(cr, split_x + pad, top,
- sidebar - 2.0 * pad, row_height, p, sim);
- }
+ // The last row contains four adjacent measurement groups, each spanning
+ // exactly one quarter of the drawable width. The fourth is the normal
+ // right-hand NIBP numeric column. The other groups are future placeholders.
+ draw_measurements_row(cr, pad, measurements_top, row_height, quarter_width,
+ numeric_width, p, sim);
+}
+
+/// Left/right split and the width of each bottom-row group. Outer margins
+/// are excluded, so 75% / 25% holds at all window sizes (no width clamping).
+fn monitor_columns(window_width: f64, pad: f64) -> (f64, f64) {
+ let quarter_width = (window_width - 2.0 * pad).max(1.0) / 4.0;
+ (pad + 3.0 * quarter_width, quarter_width)
}
-/// Compute the same row boundaries for the waveform and numeric columns.
-/// NIBP, when visible, occupies the final row and leaves its left cell empty.
-fn monitor_rows(header: f64, body_height: f64, trace_count: usize, show_nibp: bool)
- -> (f64, Option<f64>) {
- let row_count = trace_count + usize::from(show_nibp);
- let row_height = body_height / row_count.max(1) as f64;
- let nibp_top = show_nibp.then_some(header + trace_count as f64 * row_height);
- (row_height, nibp_top)
+/// The bottom measurement row always exists, even when NIBP is hidden: the
+/// remaining three groups are reserved for future parameters. Waveform rows
+/// above it still reflow when individual channels are hidden.
+fn monitor_rows(header: f64, body_height: f64, trace_count: usize) -> (f64, f64) {
+ let row_height = body_height / (trace_count + 1) as f64;
+ let measurements_top = header + trace_count as f64 * row_height;
+ (row_height, measurements_top)
+}
+
+const FUTURE_MEASUREMENT_LABELS: [&str; 3] = ["CO / CI", "SVRI · GEDI · ELWI", ""];
+
+#[allow(clippy::too_many_arguments)]
+fn draw_measurements_row(cr: &Context, left: f64, top: f64, height: f64,
+ quarter_width: f64, numeric_width: f64,
+ p: &Parameters, sim: &Simulator) {
+ let bottom = top + height;
+ stroke_line(cr, left, bottom, left + 4.0 * quarter_width, bottom, MUTED, 0.65);
+ let label_size = (height * 0.135).clamp(11.0, 19.0);
+ for (index, label) in FUTURE_MEASUREMENT_LABELS.iter().enumerate() {
+ let cell_left = left + index as f64 * quarter_width;
+ if index > 0 {
+ stroke_line(cr, cell_left, top, cell_left, bottom, MUTED, 0.65);
+ }
+ if !label.is_empty() {
+ // Placeholder labels only: no numerical values or simulated data.
+ fitted_text(cr, label, cell_left + quarter_width * 0.06,
+ top + height * 0.24, label_size,
+ quarter_width * 0.88, LIGHT_GREY);
+ }
+ }
+ // The existing global column separator supplies the fourth divider.
+ if p.show_nibp {
+ draw_nibp_box(cr, left + 3.0 * quarter_width + (quarter_width - numeric_width) * 0.5, top,
+ numeric_width, height, p, sim);
+ }
}
fn draw_nibp_box(cr: &Context, x: f64, top: f64, width: f64, height: f64,
@@ -555,26 +588,41 @@ mod tests {
use super::*;
#[test]
- fn monitor_rows_align_waveforms_and_numbers_with_blank_nibp_left_cell() {
+ fn monitor_rows_align_waveforms_and_bottom_measurements() {
let header = 60.0;
let body_height = 700.0;
- let (height, nibp_top) = monitor_rows(header, body_height, 4, true);
+ let (height, measurements_top) = monitor_rows(header, body_height, 4);
assert_eq!(height, 140.0);
- assert_eq!(nibp_top, Some(620.0));
+ assert_eq!(measurements_top, 620.0);
// Every waveform row and its corresponding numeric row share boundaries.
for index in 0..4 {
let top = header + index as f64 * height;
let bottom = top + height;
assert_eq!(bottom, header + (index + 1) as f64 * height);
}
- assert_eq!(nibp_top.unwrap() + height, header + body_height);
+ assert_eq!(measurements_top + height, header + body_height);
}
#[test]
- fn monitor_rows_reflow_when_nibp_or_waveforms_are_hidden() {
- assert_eq!(monitor_rows(60.0, 700.0, 4, false), (175.0, None));
- assert_eq!(monitor_rows(60.0, 700.0, 0, true), (700.0, Some(60.0)));
- assert_eq!(monitor_rows(60.0, 700.0, 0, false), (700.0, None));
+ fn bottom_measurements_remain_when_nibp_or_waveforms_are_hidden() {
+ // Hiding NIBP only clears the fourth cell; the placeholders stay.
+ assert_eq!(monitor_rows(60.0, 700.0, 4), (140.0, 620.0));
+ assert_eq!(monitor_rows(60.0, 700.0, 2), (700.0 / 3.0, 60.0 + 2.0 * (700.0 / 3.0)));
+ assert_eq!(monitor_rows(60.0, 700.0, 0), (700.0, 60.0));
+ }
+
+ #[test]
+ fn waveform_split_is_three_quarters_and_bottom_groups_are_equal() {
+ for (width, pad) in [(800.0, 10.0), (1280.0, 20.0), (2560.0, 20.0)] {
+ let (split, group) = monitor_columns(width, pad);
+ let usable = width - 2.0 * pad;
+ assert!((split - (pad + 0.75 * usable)).abs() < 1e-9);
+ assert!((group - 0.25 * usable).abs() < 1e-9);
+ assert!((split - (pad + 3.0 * group)).abs() < 1e-9);
+ assert!((pad + 4.0 * group - (width - pad)).abs() < 1e-9);
+ }
+ assert_eq!(FUTURE_MEASUREMENT_LABELS,
+ ["CO / CI", "SVRI · GEDI · ELWI", ""]);
}
#[test]