moce patches
This commit is contained in:
parent
2c0dc760d9
commit
5665d68db0
37 changed files with 1472 additions and 570 deletions
|
|
@ -1,526 +0,0 @@
|
|||
--- a/Cargo.toml
|
||||
+++ b/Cargo.toml
|
||||
@@ -1,6 +1,6 @@
|
||||
[package]
|
||||
name = "patient-monitor-simulation"
|
||||
-version = "0.3.1"
|
||||
+version = "0.3.2"
|
||||
edition = "2021"
|
||||
license = "MIT"
|
||||
description = "Synthetic patient-monitor simulation for teaching (not for clinical use)"
|
||||
--- a/README.md
|
||||
+++ b/README.md
|
||||
@@ -1,4 +1,4 @@
|
||||
-# Patient Monitor Simulation (PaMSim) — v0.3.1
|
||||
+# Patient Monitor Simulation (PaMSim) — v0.3.2
|
||||
|
||||
A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux.
|
||||
|
||||
@@ -20,14 +20,17 @@
|
||||
|
||||
## Windows
|
||||
|
||||
-**Admin:** Controls ECG rhythm and rate; mechanical capture; SpO₂; invasive
|
||||
-arterial pressure, waveform shape and pulse-pressure variation; NIBP; and
|
||||
-capnography. Numeric inputs have bidirectionally linked sliders and text fields.
|
||||
+**Admin:** Controls patient name; ECG rhythm and rate; mechanical capture;
|
||||
+SpO₂, signal quality and sensor connection; invasive arterial pressure,
|
||||
+waveform shape and pulse-pressure variation; NIBP; and capnography. Numeric inputs have bidirectionally linked sliders and text fields.
|
||||
Each of the five monitor parameters (ECG, SpO₂/pleth, ART, CO₂, NIBP) has its
|
||||
own **Show on monitor** checkbox.
|
||||
|
||||
**Monitor:** Black background; ECG green, pleth yellow, ART red and capnogram
|
||||
-light grey. Waveforms and vital signs disappear together when their respective
|
||||
+light grey. The patient name entered in Admin replaces **PATIENT MONITOR** in
|
||||
+the header immediately; leaving the name blank restores the generic title.
|
||||
+Long names are automatically resized or clipped to fit the header.
|
||||
+Waveforms and vital signs disappear together when their respective
|
||||
visibility checkbox is cleared. Remaining waveform rows expand to use the space.
|
||||
Hiding a display channel does **not** stop signal generation or physiological
|
||||
coupling: for example, hiding ECG does not stop ART or pleth pulses. NIBP can
|
||||
@@ -36,6 +39,41 @@
|
||||
The monitor can be resized and toggled fullscreen with **F11**; **Esc** exits
|
||||
fullscreen. On Wayland, move the monitor to the presentation screen before
|
||||
activating fullscreen. Fullscreen does not lock down the computer.
|
||||
+
|
||||
+## Patient name and pulse oximeter signal state (new in v0.3.2)
|
||||
+
|
||||
+The new **Patient name** text field at the top of Admin immediately replaces the
|
||||
+monitor headline. It is optional; an empty or whitespace-only name displays
|
||||
+**PATIENT MONITOR**. This is a local teaching label, not a patient record.
|
||||
+
|
||||
+Admin → **Pulse oximetry** has two additional controls:
|
||||
+
|
||||
+- **Sensor not attached** (checkbox): immediately removes the pleth waveform,
|
||||
+ suppresses SpO₂ and pulse-rate readings, and displays **NO SENSOR** instead
|
||||
+ of the numeric saturation. This takes precedence over signal quality.
|
||||
+- **Signal quality** (dropdown), which changes the visible pleth waveform and
|
||||
+ quality indicator, independently of the instructor-set SpO₂ percentage:
|
||||
+
|
||||
+| Setting | Pleth waveform | Monitor display |
|
||||
+| --- | --- | --- |
|
||||
+| **0 — None** | No waveform | SpO₂ `--`, PR `--`, **NO SIGNAL**; no stars |
|
||||
+| **1 — Poor** | Small, irregularly amplitude-distorted pulse | 1 star (★) |
|
||||
+| **2 — Adequate** | Medium, smoothly damped pulse | 2 stars (★★) |
|
||||
+| **3 — Good** | Full nominal, smoothly damped pulse | 3 stars (★★★) |
|
||||
+
|
||||
+Default: sensor attached; signal quality **3 — Good**. At levels 1–3, the
|
||||
+instructor-set SpO₂ number is shown only when mechanical pulses are detected.
|
||||
+The signal quality does **not** randomly alter that number: it affects the
|
||||
+pleth morphology and the quality indicator only. The simulated pulse rate
|
||||
+remains derived from mechanically captured QRS complexes.
|
||||
+
|
||||
+The degraded waveform uses deterministic, smoothly interpolated pseudo-noise
|
||||
+that scales only existing pleth pulses: it cannot manufacture pulses during
|
||||
+PEA, ventricular fibrillation or asystole. Unplugging a sensor or selecting
|
||||
+quality 0 hides even previously buffered pleth samples immediately. ECG and
|
||||
+ART continue unaffected. The **Show on monitor** checkbox still hides the
|
||||
+entire SpO₂ row; sensor/quality controls leave the row visible so the status
|
||||
+can be taught.
|
||||
|
||||
## ECG and mechanical coupling
|
||||
|
||||
@@ -161,3 +199,17 @@
|
||||
**Verification:** The archive is generated from these sources. Run `cargo test`
|
||||
locally to verify the Rust/GTK build; Rust and GTK4 development components
|
||||
were not available in the environment where this ZIP was prepared.
|
||||
+
|
||||
+## Changes in v0.3.2
|
||||
+
|
||||
+1. Added live patient-name header in Admin/Monitor with blank-name fallback.
|
||||
+2. Added four levels of SpO₂ signal quality, quality stars and an irregular,
|
||||
+ low-amplitude pleth waveform for Poor quality.
|
||||
+3. Added **Sensor not attached** with `NO SENSOR` status and suppression of
|
||||
+ saturation, pulse rate and pleth waveform.
|
||||
+4. Added tests for signal-quality scaling, displayed readings and disconnected
|
||||
+ sensor behavior.
|
||||
+
|
||||
+**Build verification:** ZIP integrity and patch application were checked.
|
||||
+The GTK4 application and Rust tests were not compiled in the packaging
|
||||
+environment; run `cargo test` and `cargo run --release` on Fedora.
|
||||
--- a/src/model.rs
|
||||
+++ b/src/model.rs
|
||||
@@ -58,12 +58,45 @@
|
||||
Obstructive,
|
||||
}
|
||||
|
||||
-#[derive(Clone, Copy, Debug)]
|
||||
+/// Instructor-selected plethysmography signal quality; separate from the
|
||||
+/// physiological oxygen-saturation setting and mechanical pulse capture.
|
||||
+#[derive(Clone, Copy, Debug, PartialEq, Eq)]
|
||||
+pub enum Spo2Quality {
|
||||
+ None,
|
||||
+ Poor,
|
||||
+ Adequate,
|
||||
+ Good,
|
||||
+}
|
||||
+
|
||||
+impl Spo2Quality {
|
||||
+ pub fn stars(self) -> &'static str {
|
||||
+ match self {
|
||||
+ Self::None => "",
|
||||
+ Self::Poor => "★",
|
||||
+ Self::Adequate => "★★",
|
||||
+ Self::Good => "★★★",
|
||||
+ }
|
||||
+ }
|
||||
+
|
||||
+ pub fn amplitude_scale(self) -> f64 {
|
||||
+ match self {
|
||||
+ Self::None => 0.0,
|
||||
+ Self::Poor => 0.25,
|
||||
+ Self::Adequate => 0.56,
|
||||
+ Self::Good => 1.0,
|
||||
+ }
|
||||
+ }
|
||||
+}
|
||||
+
|
||||
+#[derive(Clone, Debug)]
|
||||
pub struct Parameters {
|
||||
+ pub patient_name: String, // displayed in the monitor header, blank = generic title
|
||||
pub ecg_rhythm: EcgRhythm,
|
||||
pub heart_rate: i32, // bpm, organized electrical rate; not mechanical pulse rate
|
||||
pub pulse_conduction: PulseConduction,
|
||||
- pub spo2: i32, // %
|
||||
+ pub spo2: i32, // %; instructor-set nominal saturation
|
||||
+ pub spo2_quality: Spo2Quality,
|
||||
+ pub spo2_sensor_attached: bool,
|
||||
pub art_systolic: i32, // mmHg, nominal pressure; display axis 0..200
|
||||
pub art_diastolic: i32, // mmHg
|
||||
pub arterial_shape: ArterialShape,
|
||||
@@ -84,10 +117,13 @@
|
||||
impl Default for Parameters {
|
||||
fn default() -> Self {
|
||||
Self {
|
||||
+ patient_name: String::new(),
|
||||
ecg_rhythm: EcgRhythm::Sinus,
|
||||
heart_rate: 75,
|
||||
pulse_conduction: PulseConduction::OneToOne,
|
||||
spo2: 98,
|
||||
+ spo2_quality: Spo2Quality::Good,
|
||||
+ spo2_sensor_attached: true,
|
||||
art_systolic: 120,
|
||||
art_diastolic: 75,
|
||||
arterial_shape: ArterialShape::Normal,
|
||||
@@ -120,6 +156,17 @@
|
||||
}
|
||||
|
||||
#[test]
|
||||
+ fn spo2_quality_stars_and_amplitude_progress_monotonically() {
|
||||
+ assert_eq!(Spo2Quality::None.stars(), "");
|
||||
+ assert_eq!(Spo2Quality::Poor.stars(), "★");
|
||||
+ assert_eq!(Spo2Quality::Adequate.stars(), "★★");
|
||||
+ assert_eq!(Spo2Quality::Good.stars(), "★★★");
|
||||
+ assert_eq!(Spo2Quality::None.amplitude_scale(), 0.0);
|
||||
+ assert!(Spo2Quality::Poor.amplitude_scale() < Spo2Quality::Adequate.amplitude_scale());
|
||||
+ assert!(Spo2Quality::Adequate.amplitude_scale() < Spo2Quality::Good.amplitude_scale());
|
||||
+ }
|
||||
+
|
||||
+ #[test]
|
||||
fn grouped_mechanical_capture_follows_requested_patterns() {
|
||||
assert_eq!((1..=8).filter(|&b| PulseConduction::TwoToOne.conducts(b)).collect::<Vec<_>>(),
|
||||
vec![1, 3, 5, 7]);
|
||||
--- a/src/render.rs
|
||||
+++ b/src/render.rs
|
||||
@@ -1,7 +1,7 @@
|
||||
//! Size-independent Cairo drawing of the synthetic bedside monitor.
|
||||
use gtk::cairo::{Context, FontSlant, FontWeight, LineCap, LineJoin};
|
||||
|
||||
-use crate::model::{mean_arterial_pressure, EcgRhythm, Parameters, PulseConduction};
|
||||
+use crate::model::{mean_arterial_pressure, EcgRhythm, Parameters, PulseConduction, Spo2Quality};
|
||||
use crate::simulation::{Sample, Simulator};
|
||||
|
||||
type Color = (f64, f64, f64);
|
||||
@@ -43,8 +43,18 @@
|
||||
let trace_right = (split_x - pad).max(trace_left + 40.0);
|
||||
let text_scale = (w.min(h * 1.7) / 850.0).clamp(0.65, 1.5);
|
||||
|
||||
- text(cr, "PATIENT MONITOR", pad + 5.0, header * 0.58, 18.0 * text_scale,
|
||||
- LIGHT_GREY, true);
|
||||
+ let patient_title = if p.patient_name.trim().is_empty() {
|
||||
+ "PATIENT MONITOR"
|
||||
+ } else {
|
||||
+ p.patient_name.trim()
|
||||
+ };
|
||||
+ let title_max_width = if w >= 850.0 {
|
||||
+ split_x - pad * 2.0 - 145.0 * text_scale
|
||||
+ } else {
|
||||
+ split_x - pad * 2.0
|
||||
+ };
|
||||
+ fitted_text(cr, patient_title, pad + 5.0, header * 0.58,
|
||||
+ 18.0 * text_scale, title_max_width.max(25.0), LIGHT_GREY);
|
||||
if w >= 850.0 {
|
||||
text(cr, "SIMULATION", split_x - 128.0 * text_scale, header * 0.58,
|
||||
11.0 * text_scale, MUTED, false);
|
||||
@@ -84,6 +94,24 @@
|
||||
}
|
||||
}
|
||||
|
||||
+fn pleth_trace_enabled(p: &Parameters) -> bool {
|
||||
+ p.spo2_sensor_attached && p.spo2_quality != Spo2Quality::None
|
||||
+}
|
||||
+
|
||||
+fn spo2_vitals(p: &Parameters, pulse_rate: Option<i32>) -> (String, String, String) {
|
||||
+ if !p.spo2_sensor_attached {
|
||||
+ return ("SpO₂".to_owned(), "NO SENSOR".to_owned(), "SpO₂ -- PR -- bpm".to_owned());
|
||||
+ }
|
||||
+ if p.spo2_quality == Spo2Quality::None {
|
||||
+ return ("SpO₂".to_owned(), "--".to_owned(), "NO SIGNAL PR -- bpm".to_owned());
|
||||
+ }
|
||||
+ (
|
||||
+ format!("SpO₂ {}", p.spo2_quality.stars()),
|
||||
+ if pulse_rate.is_some() { p.spo2.to_string() } else { "--".to_owned() },
|
||||
+ format!("% PR {} bpm", pulse_rate.map_or("--".to_owned(), |pr| pr.to_string())),
|
||||
+ )
|
||||
+}
|
||||
+
|
||||
fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64,
|
||||
top: f64, row_h: f64, width: f64, p: &Parameters, sim: &Simulator) {
|
||||
let label_size = (row_h * 0.135).clamp(11.0, 19.0);
|
||||
@@ -95,7 +123,7 @@
|
||||
let pulse_rate = if has_capture { sim.pulse_rate() } else { None };
|
||||
let (label, value, info) = match ch {
|
||||
Channel::Ecg => (
|
||||
- "HR",
|
||||
+ "HR".to_owned(),
|
||||
if !p.ecg_rhythm.has_qrs() || p.heart_rate <= 0 { "--".to_owned() }
|
||||
else { p.heart_rate.to_string() },
|
||||
format!("bpm · {}", match p.ecg_rhythm {
|
||||
@@ -106,13 +134,9 @@
|
||||
EcgRhythm::Asystole => "Asystole",
|
||||
}),
|
||||
),
|
||||
- Channel::Pleth => (
|
||||
- "SpO₂",
|
||||
- if pulse_rate.is_some() { p.spo2.to_string() } else { "--".to_owned() },
|
||||
- format!("% PR {} bpm", pulse_rate.map_or("--".to_owned(), |pr| pr.to_string())),
|
||||
- ),
|
||||
+ Channel::Pleth => spo2_vitals(p, pulse_rate),
|
||||
Channel::Art => (
|
||||
- "ART",
|
||||
+ "ART".to_owned(),
|
||||
if pulse_rate.is_some() {
|
||||
format!("{}/{}", p.art_systolic, p.art_diastolic)
|
||||
} else { "--/--".to_owned() },
|
||||
@@ -126,13 +150,20 @@
|
||||
}
|
||||
} else { "MAP -- mmHg".to_owned() },
|
||||
),
|
||||
- Channel::Capno => ("EtCO₂", p.etco2.to_string(),
|
||||
+ Channel::Capno => ("EtCO₂".to_owned(), p.etco2.to_string(),
|
||||
format!("mmHg RR {} /min", p.respiratory_rate)),
|
||||
};
|
||||
- text(cr, label, x, top + row_h * 0.24, label_size, color, false);
|
||||
- // Reduce wide BP values so they fit within the sidebar.
|
||||
- let value_size = if matches!(ch, Channel::Art) { number_size * 0.78 } else { number_size };
|
||||
- text(cr, &value, x, top + row_h * 0.64, value_size, color, true);
|
||||
+ text(cr, &label, x, top + row_h * 0.24, label_size, color, false);
|
||||
+ // Reduce wide readings so they fit within the sidebar.
|
||||
+ let value_size = if value == "NO SENSOR" {
|
||||
+ number_size.min(0.19 * width).min(26.0)
|
||||
+ } else if matches!(ch, Channel::Art) {
|
||||
+ number_size * 0.78
|
||||
+ } else {
|
||||
+ number_size
|
||||
+ };
|
||||
+ fitted_text(cr, &value, x, top + row_h * 0.64, value_size,
|
||||
+ width.max(20.0), color);
|
||||
text(cr, &info, x, top + row_h * 0.87, sub_size * 0.85, color, false);
|
||||
}
|
||||
|
||||
@@ -175,6 +206,13 @@
|
||||
right, top + trace_height * 0.5, GRID, 0.7);
|
||||
}
|
||||
|
||||
+ // Disconnected or absent pleth signal: no curve, including historical pulses.
|
||||
+ if matches!(channel, Channel::Pleth) && !pleth_trace_enabled(p)
|
||||
+ {
|
||||
+ let _ = cr.restore();
|
||||
+ return;
|
||||
+ }
|
||||
+
|
||||
set_color(cr, color);
|
||||
cr.set_line_width((trace_height * 0.016).clamp(1.2, 2.4));
|
||||
cr.set_line_cap(LineCap::Round);
|
||||
@@ -194,11 +232,66 @@
|
||||
fn normalized(channel: Channel, s: &Sample, p: &Parameters) -> f64 {
|
||||
match channel {
|
||||
Channel::Ecg => (0.40 + s.ecg * 0.38).clamp(0.02, 0.98),
|
||||
- Channel::Pleth => (0.10 + s.pleth * 0.78).clamp(0.02, 0.98),
|
||||
+ Channel::Pleth => (0.10 + pleth_visual_amplitude(s.pleth, s.time, p.spo2_quality) * 0.78)
|
||||
+ .clamp(0.02, 0.98),
|
||||
Channel::Art => (s.art / 200.0).clamp(0.0, 1.0),
|
||||
Channel::Capno => (0.08 + (s.co2 / f64::from(p.etco2.max(1))) * 0.80)
|
||||
.clamp(0.02, 0.98),
|
||||
}
|
||||
+}
|
||||
+
|
||||
+/// Signal degradation is presentation-only: no quality setting can invent
|
||||
+/// pulses or change the ECG/ART generator. The noise is smoothly interpolated
|
||||
+/// and reproducible, so redrawing a sample does not make it flicker.
|
||||
+fn pleth_visual_amplitude(pleth: f64, time: f64, quality: Spo2Quality) -> f64 {
|
||||
+ let scale = quality.amplitude_scale();
|
||||
+ if scale == 0.0 || pleth <= 0.0 { return 0.0; }
|
||||
+ let distortion = if quality == Spo2Quality::Poor {
|
||||
+ (1.0 + 0.55 * smooth_noise(time * 7.0)
|
||||
+ + 0.20 * smooth_noise(time * 23.0 + 4.0)).clamp(0.15, 1.75)
|
||||
+ } else {
|
||||
+ 1.0
|
||||
+ };
|
||||
+ (pleth * scale * distortion).clamp(0.0, 1.0)
|
||||
+}
|
||||
+
|
||||
+fn smooth_noise(position: f64) -> f64 {
|
||||
+ let index = position.floor() as i64;
|
||||
+ let fraction = position - index as f64;
|
||||
+ let smooth = fraction * fraction * (3.0 - 2.0 * fraction);
|
||||
+ let a = noise_value(index);
|
||||
+ let b = noise_value(index.wrapping_add(1));
|
||||
+ a + (b - a) * smooth
|
||||
+}
|
||||
+
|
||||
+fn noise_value(index: i64) -> f64 {
|
||||
+ let mut x = (index as u64).wrapping_mul(0x9E37_79B9_7F4A_7C15);
|
||||
+ x ^= x >> 30;
|
||||
+ x = x.wrapping_mul(0xBF58_476D_1CE4_E5B9);
|
||||
+ x ^= x >> 27;
|
||||
+ x = x.wrapping_mul(0x94D0_49BB_1331_11EB);
|
||||
+ x ^= x >> 31;
|
||||
+ (x as f64 / u64::MAX as f64) * 2.0 - 1.0
|
||||
+}
|
||||
+
|
||||
+/// Fit a name or numeric/status reading horizontally without changing the
|
||||
+/// other monitor dimensions. For exceptionally long values, clip safely.
|
||||
+fn fitted_text(cr: &Context, value: &str, x: f64, baseline: f64,
|
||||
+ nominal_size: f64, available_width: f64, color: Color) {
|
||||
+ cr.select_font_face("Sans", FontSlant::Normal, FontWeight::Bold);
|
||||
+ cr.set_font_size(nominal_size);
|
||||
+ let actual_width = cr.text_extents(value).map(|ext| ext.x_advance()).unwrap_or(0.0);
|
||||
+ let fitted_size = if actual_width > available_width && actual_width > 0.0 {
|
||||
+ (nominal_size * available_width / actual_width).max(8.0)
|
||||
+ } else {
|
||||
+ nominal_size
|
||||
+ };
|
||||
+ let _ = cr.save();
|
||||
+ cr.rectangle(x, baseline - fitted_size * 1.25,
|
||||
+ available_width.max(1.0), fitted_size * 1.55);
|
||||
+ cr.clip();
|
||||
+ text(cr, value, x, baseline, fitted_size, color, true);
|
||||
+ let _ = cr.restore();
|
||||
}
|
||||
|
||||
fn set_color(cr: &Context, c: Color) {
|
||||
@@ -243,6 +336,53 @@
|
||||
}
|
||||
|
||||
#[test]
|
||||
+ fn pleth_degradation_preserves_capture_timing_and_suppresses_false_pulses() {
|
||||
+ let pulse = 0.6;
|
||||
+ let t = 1.234;
|
||||
+ assert_eq!(pleth_visual_amplitude(pulse, t, Spo2Quality::None), 0.0);
|
||||
+ assert_eq!(pleth_visual_amplitude(0.0, t, Spo2Quality::Poor), 0.0);
|
||||
+ assert!(pleth_visual_amplitude(pulse, t, Spo2Quality::Poor)
|
||||
+ < pleth_visual_amplitude(pulse, t, Spo2Quality::Adequate));
|
||||
+ assert!(pleth_visual_amplitude(pulse, t, Spo2Quality::Adequate)
|
||||
+ < pleth_visual_amplitude(pulse, t, Spo2Quality::Good));
|
||||
+ assert_eq!(pleth_visual_amplitude(pulse, t, Spo2Quality::Good), pulse);
|
||||
+ assert_eq!(pleth_visual_amplitude(pulse, t, Spo2Quality::Poor),
|
||||
+ pleth_visual_amplitude(pulse, t, Spo2Quality::Poor));
|
||||
+ assert_ne!(pleth_visual_amplitude(pulse, t, Spo2Quality::Poor),
|
||||
+ pleth_visual_amplitude(pulse, t + 0.5, Spo2Quality::Poor));
|
||||
+ }
|
||||
+
|
||||
+ #[test]
|
||||
+ fn disconnected_or_no_quality_means_no_pleth_or_spo2_reading() {
|
||||
+ let mut p = Parameters::default();
|
||||
+ assert!(pleth_trace_enabled(&p));
|
||||
+ p.spo2_sensor_attached = false;
|
||||
+ assert!(!pleth_trace_enabled(&p));
|
||||
+ assert_eq!(spo2_vitals(&p, Some(75)).1, "NO SENSOR");
|
||||
+ assert!(spo2_vitals(&p, Some(75)).2.contains("PR --"));
|
||||
+ p.spo2_sensor_attached = true;
|
||||
+ p.spo2_quality = Spo2Quality::None;
|
||||
+ assert!(!pleth_trace_enabled(&p));
|
||||
+ assert_eq!(spo2_vitals(&p, Some(75)).1, "--");
|
||||
+ assert!(spo2_vitals(&p, Some(75)).2.contains("NO SIGNAL"));
|
||||
+ assert!(spo2_vitals(&p, Some(75)).2.contains("PR --"));
|
||||
+ assert!(p.show_spo2); // no readings, but visible row and status
|
||||
+ }
|
||||
+
|
||||
+ #[test]
|
||||
+ fn poor_and_good_quality_keep_derived_pr_and_quality_indicators() {
|
||||
+ let mut p = Parameters::default();
|
||||
+ p.spo2_quality = Spo2Quality::Poor;
|
||||
+ assert_eq!(spo2_vitals(&p, Some(75)).0, "SpO₂ ★");
|
||||
+ assert_eq!(spo2_vitals(&p, Some(75)).1, "98");
|
||||
+ assert!(spo2_vitals(&p, Some(75)).2.contains("PR 75 bpm"));
|
||||
+ p.spo2_quality = Spo2Quality::Good;
|
||||
+ assert_eq!(spo2_vitals(&p, Some(75)).0, "SpO₂ ★★★");
|
||||
+ assert_eq!(spo2_vitals(&p, None).1, "--");
|
||||
+ assert!(spo2_vitals(&p, None).2.contains("PR --"));
|
||||
+ }
|
||||
+
|
||||
+ #[test]
|
||||
fn arterial_axis_is_absolute_and_fixed_to_200_mmhg() {
|
||||
let p = Parameters::default();
|
||||
let mut s = Sample { time: 0.0, ecg: 0.0, pleth: 0.0, art: 100.0, co2: 0.0 };
|
||||
--- a/src/ui.rs
|
||||
+++ b/src/ui.rs
|
||||
@@ -8,7 +8,7 @@
|
||||
use gtk::prelude::*;
|
||||
use gtk::{Application, ApplicationWindow, Orientation};
|
||||
|
||||
-use crate::model::{ArterialShape, CapnoShape, EcgRhythm, Parameters, PulseConduction};
|
||||
+use crate::model::{ArterialShape, CapnoShape, EcgRhythm, Parameters, PulseConduction, Spo2Quality};
|
||||
use crate::render;
|
||||
use crate::simulation::Simulator;
|
||||
|
||||
@@ -41,7 +41,7 @@
|
||||
let params = params.clone();
|
||||
let simulator = simulator.clone();
|
||||
move |_area, cr, width, height| {
|
||||
- let config = *params.borrow();
|
||||
+ let config = params.borrow();
|
||||
render::draw(cr, width, height, &config, &simulator.borrow());
|
||||
}
|
||||
});
|
||||
@@ -54,7 +54,7 @@
|
||||
let now = Instant::now();
|
||||
let elapsed = now.saturating_duration_since(previous.get()).as_secs_f64();
|
||||
previous.set(now);
|
||||
- let config = *params.borrow();
|
||||
+ let config = params.borrow();
|
||||
simulator.borrow_mut().advance(elapsed, &config);
|
||||
area.queue_draw();
|
||||
glib::ControlFlow::Continue
|
||||
@@ -104,6 +104,24 @@
|
||||
scroller.set_vexpand(true);
|
||||
scroller.set_policy(gtk::PolicyType::Never, gtk::PolicyType::Automatic);
|
||||
let controls = gtk::Box::new(Orientation::Vertical, 12);
|
||||
+
|
||||
+ let patient = group(&controls, "Patient");
|
||||
+ let patient_row = gtk::Box::new(Orientation::Horizontal, 8);
|
||||
+ let patient_label = gtk::Label::new(Some("Patient name"));
|
||||
+ patient_label.set_xalign(0.0);
|
||||
+ patient_label.set_width_chars(17);
|
||||
+ let name_entry = gtk::Entry::new();
|
||||
+ name_entry.set_hexpand(true);
|
||||
+ name_entry.set_max_length(80);
|
||||
+ name_entry.set_placeholder_text(Some("Name displayed on monitor"));
|
||||
+ name_entry.set_text(¶ms.borrow().patient_name);
|
||||
+ name_entry.connect_changed({
|
||||
+ let params = params.clone();
|
||||
+ move |entry| params.borrow_mut().patient_name = entry.text().to_string()
|
||||
+ });
|
||||
+ patient_row.append(&patient_label);
|
||||
+ patient_row.append(&name_entry);
|
||||
+ patient.append(&patient_row);
|
||||
|
||||
let ecg = group(&controls, "ECG");
|
||||
add_visibility(&ecg, params.borrow().show_ecg, params.clone(), |p, show| p.show_ecg = show);
|
||||
@@ -126,6 +144,26 @@
|
||||
add_visibility(&spo2, params.borrow().show_spo2, params.clone(), |p, show| p.show_spo2 = show);
|
||||
add_numeric(&spo2, "SpO₂", "%", 0, 100, params.borrow().spo2,
|
||||
params.clone(), |p, v| p.spo2 = v);
|
||||
+ let sensor = gtk::CheckButton::with_label("Sensor not attached");
|
||||
+ sensor.set_active(!params.borrow().spo2_sensor_attached);
|
||||
+ sensor.connect_toggled({
|
||||
+ let params = params.clone();
|
||||
+ move |button| params.borrow_mut().spo2_sensor_attached = !button.is_active()
|
||||
+ });
|
||||
+ spo2.append(&sensor);
|
||||
+ add_dropdown_at(&spo2, "Signal quality", &[
|
||||
+ "0 — None (no reading)",
|
||||
+ "1 — Poor (*)",
|
||||
+ "2 — Adequate (**)",
|
||||
+ "3 — Good (***)",
|
||||
+ ], params.borrow().spo2_quality as u32, params.clone(), |p, selected| {
|
||||
+ p.spo2_quality = match selected {
|
||||
+ 1 => Spo2Quality::Poor,
|
||||
+ 2 => Spo2Quality::Adequate,
|
||||
+ 3 => Spo2Quality::Good,
|
||||
+ _ => Spo2Quality::None,
|
||||
+ };
|
||||
+ });
|
||||
add_dropdown(&spo2, "Mechanical capture", &[
|
||||
"1:1 (every QRS)",
|
||||
"2:1 (one pulse in two)",
|
||||
@@ -243,11 +281,18 @@
|
||||
fn add_dropdown<F>(parent: >k::Box, label: &str, items: &[&str],
|
||||
params: SharedParams, setter: F)
|
||||
where F: Fn(&mut Parameters, u32) + 'static {
|
||||
+ add_dropdown_at(parent, label, items, 0, params, setter);
|
||||
+}
|
||||
+
|
||||
+fn add_dropdown_at<F>(parent: >k::Box, label: &str, items: &[&str],
|
||||
+ initial: u32, params: SharedParams, setter: F)
|
||||
+where F: Fn(&mut Parameters, u32) + 'static {
|
||||
let row = gtk::Box::new(Orientation::Horizontal, 8);
|
||||
let caption = gtk::Label::new(Some(label));
|
||||
caption.set_xalign(0.0);
|
||||
caption.set_width_chars(17);
|
||||
let combo = gtk::DropDown::from_strings(items);
|
||||
+ combo.set_selected(initial);
|
||||
combo.set_hexpand(true);
|
||||
combo.connect_selected_notify(move |combo| {
|
||||
setter(&mut params.borrow_mut(), combo.selected());
|
||||
Loading…
Reference in a new issue