moce patches
This commit is contained in:
parent
2c0dc760d9
commit
5665d68db0
37 changed files with 1472 additions and 570 deletions
|
|
@ -1,189 +0,0 @@
|
|||
diff --git a/Cargo.toml b/Cargo.toml
|
||||
index f3abff3..eda3ddf 100644
|
||||
--- a/Cargo.toml
|
||||
+++ b/Cargo.toml
|
||||
@@ -1,6 +1,6 @@
|
||||
[package]
|
||||
name = "patient-monitor-simulation"
|
||||
-version = "0.6.6"
|
||||
+version = "0.6.7"
|
||||
edition = "2021"
|
||||
license = "MIT"
|
||||
description = "Synthetic patient-monitor simulation for teaching (not for clinical use)"
|
||||
diff --git a/README.de.md b/README.de.md
|
||||
index 605a34f..17890f5 100644
|
||||
--- a/README.de.md
|
||||
+++ b/README.de.md
|
||||
@@ -1,4 +1,4 @@
|
||||
-# Patient Monitor Simulation (PaMSim) — v0.6.6
|
||||
+# Patient Monitor Simulation (PaMSim) — v0.6.7
|
||||
|
||||
Ein mit Rust und GTK4 entwickelter Patient*innenmonitor-Simulator mit zwei Fenstern für die Lehre unter Fedora Linux.
|
||||
|
||||
@@ -6,6 +6,17 @@ Ein mit Rust und GTK4 entwickelter Patient*innenmonitor-Simulator mit zwei Fenst
|
||||
> EKG, invasive arterielle Druckkurve, Plethysmogramm und Kapnogramm sind schematische mathematische Annäherungen.
|
||||
> Die Simulation wurde nicht klinisch validiert und ist kein Medizinprodukt.
|
||||
|
||||
+## Stufenlose Herzfrequenzänderung (v0.6.7)
|
||||
+
|
||||
+Bei Änderungen der Herzfrequenz bleibt die Historie der zuletzt *mechanisch
|
||||
+wirksamen* Herzschläge erhalten. Die angezeigte Pulsfrequenz passt sich über
|
||||
+den gleitenden Mittelwert der letzten drei Pulsintervalle an, ohne
|
||||
+zwischenzeitlich zu verschwinden. SpO₂-Wert, Plethysmogramm und
|
||||
+sättigungsabhängiger Pulston bleiben bei gewöhnlichen Änderungen der
|
||||
+Herzfrequenz erhalten. Ein tatsächlicher Verlust der mechanischen
|
||||
+Pulsüberleitung, ein abgesteckter Sensor und wirkliche Signalausfälle lösen
|
||||
+weiterhin unmittelbar die vorgesehenen Alarme aus.
|
||||
+
|
||||
## Monitoraufteilung (v0.5.7)
|
||||
|
||||
Der nutzbare Monitorbereich wird in einem festen Verhältnis von **75 % für die
|
||||
@@ -175,7 +186,7 @@ Mit **F11** wird der Vollbildmodus aktiviert bzw. umgeschaltet, mit **Esc** wird
|
||||
Unter Wayland sollte das Fenster vor dem Wechsel in den Vollbildmodus auf den gewünschten Präsentationsbildschirm verschoben werden.
|
||||
Der Vollbildmodus sperrt den Computer nicht gegen andere Eingaben.
|
||||
|
||||
-## Akustische Alarme und QRS-Ton (aktualisiert v0.6.6)
|
||||
+## Akustische Alarme und QRS-Ton (aktualisiert v0.6.7)
|
||||
|
||||
Die akustische Alarmierung ist **standardmäßig eingeschaltet**. Im
|
||||
Admin-Fenster lässt sie sich mit **Audible alarms** aktivieren bzw. stummschalten.
|
||||
diff --git a/README.md b/README.md
|
||||
index 250b938..793a3d4 100644
|
||||
--- a/README.md
|
||||
+++ b/README.md
|
||||
@@ -1,4 +1,4 @@
|
||||
-# Patient Monitor Simulation (PaMSim) — v0.6.6
|
||||
+# Patient Monitor Simulation (PaMSim) — v0.6.7
|
||||
|
||||
A Rust/GTK4 patient-monitor simulator with two main windows for teaching on Fedora Linux.
|
||||
|
||||
@@ -6,6 +6,16 @@ A Rust/GTK4 patient-monitor simulator with two main windows for teaching on Fedo
|
||||
> plethysmography and capnography are schematic mathematical approximations. The
|
||||
> simulation has no clinical validation and is not a medical device.
|
||||
|
||||
+## Smooth HR transitions (v0.6.7)
|
||||
+
|
||||
+Changing the HR slider now preserves the recent history of *mechanically
|
||||
+captured* beats. PR converges to the new rate using the existing rolling
|
||||
+three-interval average instead of temporarily disappearing. The SpO₂ value,
|
||||
+plethysmography and saturation-dependent QRS tone remain available during
|
||||
+ordinary HR adjustments. Actual loss of mechanical capture, disconnected
|
||||
+sensors, deliberate signal dropout and low-quality/absent signals still
|
||||
+produce their intended alarms immediately.
|
||||
+
|
||||
## Monitor layout (v0.5.7)
|
||||
|
||||
The monitor uses a fixed **3:1 column ratio** over the drawable area:
|
||||
@@ -166,7 +176,7 @@ The monitor can be resized and toggled fullscreen with **F11**; **Esc** exits
|
||||
fullscreen. On Wayland, move the monitor to the presentation screen before
|
||||
activating fullscreen. Fullscreen does not lock down the computer.
|
||||
|
||||
-## Audible alarms and QRS tone (updated v0.6.6)
|
||||
+## Audible alarms and QRS tone (updated v0.6.7)
|
||||
|
||||
Sound is **enabled by default**. The Admin window has an **Audible alarms**
|
||||
checkbox for muting and a **Test tone** button (works even while muted).
|
||||
diff --git a/src/simulation.rs b/src/simulation.rs
|
||||
index ec88a5a..800293f 100644
|
||||
--- a/src/simulation.rs
|
||||
+++ b/src/simulation.rs
|
||||
@@ -197,12 +197,11 @@ pub struct Simulator {
|
||||
respiratory_phase: f64,
|
||||
ecg_beat_number: u64,
|
||||
conducted_qrs: VecDeque<ConductedBeat>, // captured QRS with respiratory beat amplitude
|
||||
- rate_qrs: VecDeque<f64>, // captured beats for measured PR; reset after rate changes
|
||||
+ rate_qrs: VecDeque<f64>, // captured beats for measured PR; rolling history smooths HR changes
|
||||
audio_events: VecDeque<BeatEvent>, // consumed by the 100-ms UI audio timer
|
||||
filtered_pleth: f64,
|
||||
previous_rhythm: EcgRhythm,
|
||||
previous_conduction: PulseConduction,
|
||||
- previous_heart_rate: i32,
|
||||
poor_signal_outages: PoorSignalOutages,
|
||||
compressions: ChestCompressions,
|
||||
nibp: NibpMachine,
|
||||
@@ -224,7 +223,6 @@ impl Simulator {
|
||||
filtered_pleth: 0.0,
|
||||
previous_rhythm: params.ecg_rhythm,
|
||||
previous_conduction: params.pulse_conduction,
|
||||
- previous_heart_rate: params.heart_rate,
|
||||
poor_signal_outages: PoorSignalOutages::new(),
|
||||
compressions: ChestCompressions::new(),
|
||||
nibp: NibpMachine::new(),
|
||||
@@ -427,12 +425,12 @@ impl Simulator {
|
||||
self.previous_rhythm = params.ecg_rhythm;
|
||||
self.previous_conduction = params.pulse_conduction;
|
||||
}
|
||||
- if params.heart_rate != self.previous_heart_rate {
|
||||
- // Old captured events remain in the *waveforms* until they pass.
|
||||
- // They must not bias the pulse rate after an HR slider change.
|
||||
- self.rate_qrs.clear();
|
||||
- self.previous_heart_rate = params.heart_rate;
|
||||
- }
|
||||
+ // Keep recent mechanically captured beats when only HR changes.
|
||||
+ // The rolling three-interval PR calculation then converges naturally
|
||||
+ // to the new rate as new pulses arrive. Clearing this history on every
|
||||
+ // slider update would briefly make PR unavailable and falsely trigger
|
||||
+ // SpO2 NO READING, even though perfusion and the sensor are intact.
|
||||
+ // Actual loss of capture is still handled above, immediately.
|
||||
|
||||
// Respiratory phase drives both the capnogram and arterial PPV.
|
||||
let respiratory_rate = params.respiratory_rate.max(0) as f64 / 60.0;
|
||||
@@ -1181,12 +1179,55 @@ mod tests {
|
||||
assert_eq!(sim.pulse_rate(), Some(75));
|
||||
p.heart_rate = 189;
|
||||
sim.step(&p);
|
||||
- // No old 75 bpm PR is displayed while the new beat interval is measured.
|
||||
- assert_eq!(sim.pulse_rate(), None);
|
||||
- for _ in 0..200 { sim.step(&p); }
|
||||
+ // A new HR must not invalidate existing mechanical pulse history.
|
||||
+ // The displayed PR is smoothed from actual conducted QRS intervals.
|
||||
+ assert_eq!(sim.pulse_rate(), Some(75));
|
||||
+ assert_eq!(sim.spo2_status(&p), Spo2Status::Available);
|
||||
+ for _ in 0..800 {
|
||||
+ sim.step(&p);
|
||||
+ assert!(sim.pulse_rate().is_some(), "PR must remain available");
|
||||
+ assert_eq!(sim.spo2_status(&p), Spo2Status::Available);
|
||||
+ assert!(sim.samples.back().unwrap().pleth_valid,
|
||||
+ "no artificial gap in the pleth trace during HR adjustment");
|
||||
+ }
|
||||
assert_eq!(sim.pulse_rate(), Some(189));
|
||||
}
|
||||
|
||||
+ #[test]
|
||||
+ fn repeated_heart_rate_slider_moves_do_not_trigger_spo2_no_reading() {
|
||||
+ let mut p = Parameters::default();
|
||||
+ let mut sim = Simulator::new(&p);
|
||||
+ for rate in [90, 105, 120, 140, 110, 80, 75] {
|
||||
+ p.heart_rate = rate;
|
||||
+ for _ in 0..40 { // only 160 ms between successive slider updates
|
||||
+ sim.step(&p);
|
||||
+ assert!(sim.pulse_rate().is_some());
|
||||
+ assert_eq!(sim.spo2_status(&p), Spo2Status::Available);
|
||||
+ assert!(sim.samples.back().unwrap().pleth_valid);
|
||||
+ }
|
||||
+ }
|
||||
+ }
|
||||
+
|
||||
+ #[test]
|
||||
+ fn conducted_two_to_one_pulses_remain_available_during_hr_change() {
|
||||
+ let mut p = Parameters { pulse_conduction: PulseConduction::TwoToOne,
|
||||
+ ..Parameters::default() };
|
||||
+ let mut sim = Simulator::new(&p);
|
||||
+ assert_eq!(sim.pulse_rate(), Some(38));
|
||||
+ p.heart_rate = 150;
|
||||
+ for _ in 0..1200 {
|
||||
+ sim.step(&p);
|
||||
+ assert!(sim.pulse_rate().is_some());
|
||||
+ assert_eq!(sim.spo2_status(&p), Spo2Status::Available);
|
||||
+ }
|
||||
+ assert_eq!(sim.pulse_rate(), Some(75));
|
||||
+ // Genuine mechanical capture loss still produces NO READING immediately.
|
||||
+ p.pulse_conduction = PulseConduction::None;
|
||||
+ sim.step(&p);
|
||||
+ assert_eq!(sim.pulse_rate(), None);
|
||||
+ assert_eq!(sim.spo2_status(&p), Spo2Status::NoReading);
|
||||
+ }
|
||||
+
|
||||
#[test]
|
||||
fn new_rate_respects_two_to_one_mechanical_capture() {
|
||||
let mut p = Parameters::default();
|
||||
Loading…
Reference in a new issue