v0.6.11 — Native PulseAudio / PipeWire audio output
Replaced external `pw-play` / `paplay` subprocesses and temporary WAV files with two dedicated Rust playback workers using `libpulse-simple-binding`. The existing two-tone alarm sounds, SpO₂-dependent QRS tones, rhythms, mute controls, alarm priorities and selective alarm-pause logic are retained. A manual test tone remains available with audible alarms switched off. Flatpak requires the PulseAudio socket and `libpulse-simple` in its SDK/runtime.
This commit is contained in:
parent
98bcdb934d
commit
56f9f2e932
12 changed files with 2071 additions and 247 deletions
|
|
@ -1,4 +1,4 @@
|
|||
# SimPaM — Patient Monitor Simulation v0.6.10
|
||||
# SimPaM — Patient Monitor Simulation v0.6.11
|
||||
|
||||
A Rust/GTK4 patient-monitor simulator with two main windows for teaching on Fedora Linux.
|
||||
|
||||
|
|
@ -38,7 +38,7 @@ monitoring.
|
|||
### Build and run on Fedora
|
||||
|
||||
```bash
|
||||
sudo dnf install rust cargo gcc pkgconf-pkg-config gtk4-devel pipewire-utils
|
||||
sudo dnf install rust cargo gcc pkgconf-pkg-config gtk4-devel pulseaudio-libs-devel
|
||||
cargo test
|
||||
cargo run --release
|
||||
```
|
||||
|
|
@ -553,9 +553,9 @@ scenarios do not unexpectedly flash.
|
|||
Numerical threshold alarms only evaluate actual displayed measurements:
|
||||
`--`, `NO SENSOR`, and other unavailable readings do not trigger low-value
|
||||
alarms. ECG-derived PR and signal visibility continue to work as in v0.3.2.
|
||||
Alarms are presentation-only: there is **no audible alarm, alarm latching,
|
||||
priority classification or clinical alarm validation**. Instructor settings
|
||||
are held in memory and reset on restart.
|
||||
Audible alarms with two priorities are supported, but there is **no alarm
|
||||
latching or clinical alarm validation**. Instructor settings are held in
|
||||
memory and reset on restart.
|
||||
|
||||
### Audible alarms and QRS tone (updated v0.6.7)
|
||||
|
||||
|
|
@ -614,12 +614,16 @@ Saturation tone pitches are deliberately simplified teaching tones, not
|
|||
calibrated clinical pulse-oximeter sounds. The QRS beep and two-tone alarm can
|
||||
sound independently; no alarm priority or visual alarm logic was changed.
|
||||
|
||||
On Fedora, sound is played through **`pw-play`** from `pipewire-utils`, with
|
||||
**`paplay`** as a fallback. No additional Rust crates or sound files are needed:
|
||||
the application creates its own short WAV tones at runtime. If neither player
|
||||
is installed, Admin reports that audio is unavailable; the monitor continues
|
||||
to work normally. `Test tone` helps verify the desktop audio output. The
|
||||
application uses the system output device and mixer volume.
|
||||
As of **v0.6.11**, audio uses the Rust `libpulse-simple-binding` backend
|
||||
directly, rather than launching `pw-play` or `paplay`. SimPaM synthesizes
|
||||
the same 44.1 kHz mono PCM16 tones in memory and sends them to two
|
||||
independent PulseAudio streams (alarm and QRS). Each stream has a
|
||||
dedicated playback thread so synchronous audio I/O never blocks GTK.
|
||||
PipeWire supports this through its PulseAudio compatibility server.
|
||||
The system mixer controls output volume. If connecting or writing to
|
||||
the audio server fails, the worker logs an error and can retry on the
|
||||
next sound. `Test tone` verifies playback independently of the mute
|
||||
checkbox. No temporary WAV files or external player programs are used.
|
||||
|
||||
**Important:** These simple teaching tones do not comply with medical-device
|
||||
alarm standards (including IEC 60601-1-8) and must never be relied on for
|
||||
|
|
@ -665,6 +669,8 @@ are simulated.
|
|||
```text
|
||||
src/
|
||||
main.rs GTK application entry point
|
||||
audio_backend.rs Native PulseAudio playback workers
|
||||
alarm.rs Alarm/QRS tone synthesis, scheduling and pause
|
||||
model.rs Parameters, rhythm/capture settings, display flags
|
||||
simulation.rs QRS-timed mechanical signals, PPV and respiratory synthesis
|
||||
render.rs Cairo monitor layout, dynamic visibility, fixed ART axis
|
||||
|
|
@ -672,6 +678,23 @@ src/
|
|||
ui.rs Admin controls and monitor window
|
||||
```
|
||||
|
||||
### Building audio in Flatpak
|
||||
|
||||
For Flatpak, keep `--socket=pulseaudio` in `finish-args` and verify the
|
||||
**target SDK** provides the `libpulse-simple` development library:
|
||||
|
||||
```bash
|
||||
flatpak run --command=sh org.gnome.Sdk//51 \
|
||||
-c 'pkg-config --modversion libpulse-simple'
|
||||
```
|
||||
|
||||
The Flatpak runtime must also ship the corresponding shared libraries.
|
||||
The host's `pipewire-utils` package is no longer required. Update `Cargo.lock`
|
||||
with Cargo after changing dependencies, then regenerate `cargo-sources.json`
|
||||
using `flatpak-cargo-generator` before building offline. The project archive
|
||||
contains application sources; an existing Flatpak manifest is maintained
|
||||
separately and was not modified by this update.
|
||||
|
||||
## Changelog
|
||||
|
||||
### Changes since v0.2.2
|
||||
|
|
@ -855,3 +878,12 @@ same controls are now permanently available. A high-contrast yellow one-tap
|
|||
Defibrillation button with a red lightning symbol triggers only the transient
|
||||
ECG shock artifact; rhythm conversion remains available as a separate action.
|
||||
|
||||
|
||||
### v0.6.11 — Native PulseAudio / PipeWire audio output
|
||||
|
||||
Replaced external `pw-play` / `paplay` subprocesses and temporary WAV files
|
||||
with two dedicated Rust playback workers using `libpulse-simple-binding`.
|
||||
The existing two-tone alarm sounds, SpO₂-dependent QRS tones, rhythms, mute
|
||||
controls, alarm priorities and selective alarm-pause logic are retained.
|
||||
A manual test tone remains available with audible alarms switched off.
|
||||
Flatpak requires the PulseAudio socket and `libpulse-simple` in its SDK/runtime.
|
||||
|
|
|
|||
Loading…