v0.6.1 — Alarm-only monitor touch menus
The ECG, SpO₂, ART, CO₂ and NIBP touch menus now edit only lower/upper alarm limits. Removed ECG lead, signal/sensor, waveform and all NIBP measurement controls from monitor-side menus. These remain available in Admin, including manual NIBP measurement and Auto ON/OFF. No physiological model, alarm evaluation or NIBP startup behavior was changed.
This commit is contained in:
parent
41e1971fae
commit
89c1c8f396
9 changed files with 878 additions and 368 deletions
|
|
@ -1,4 +1,4 @@
|
|||
# Patient Monitor Simulation (PaMSim) — v0.6.0
|
||||
# Patient Monitor Simulation (PaMSim) — v0.6.1
|
||||
|
||||
A Rust/GTK4 patient-monitor simulator with two main windows for teaching on Fedora Linux.
|
||||
|
||||
|
|
@ -23,79 +23,49 @@ The NIBP visibility toggle hides **only the fourth group's content**; the
|
|||
bottom measurement row and other three groups remain present. Disabling one
|
||||
of the four waveform channels still reflows the remaining rows above it.
|
||||
|
||||
## ECG touchscreen settings (v0.5.9)
|
||||
## Monitor touchscreen: alarm limits only (v0.6.1)
|
||||
|
||||
Tap or click **anywhere in the ECG row**, on either the **trace (left 75%)** or
|
||||
**heart-rate readout (right 25%)**, to open a modal **black-and-light-grey ECG settings**
|
||||
window above the monitor. The same interaction works when the monitor is in
|
||||
fullscreen mode. The same interaction now applies to the other channels.
|
||||
Hiding
|
||||
the ECG channel also disables its touch target.
|
||||
Tap or click the **waveform or numerical readout** of ECG, SpO₂, ART or CO₂
|
||||
to open that channel's alarm-limit panel. For NIBP, tap the **rightmost
|
||||
quarter of the bottom measurement row**. The other three bottom-row groups
|
||||
are reserved for future measurements and remain non-interactive. The panels
|
||||
are available in fullscreen and retain a **black background, very light-grey
|
||||
text, and 0.8-pixel borders and dividers**, in the style of the main monitor.
|
||||
|
||||
The menu offers:
|
||||
**Only alarm thresholds can be modified from the monitor-side menus.**
|
||||
No keyboard is required: every lower/upper limit has large **− / +** controls
|
||||
with a parameter-specific increment and an independent **ON/OFF** control.
|
||||
Unset limits remain disabled. The lower limit cannot exceed the upper limit.
|
||||
|
||||
- **ECG lead:** I, II (default), III, aVR, aVL, aVF, and V1–V6. The monitor
|
||||
trace label changes immediately after **Apply**, and the waveform undergoes
|
||||
an *illustrative lead-dependent gain/polarity transformation*. This is **not**
|
||||
a diagnostic 12-lead ECG derivation; cardiac timing, HR and mechanical
|
||||
capture do not change when the lead changes.
|
||||
- **HR alarm limits:** optional **↓ Lower** and **↑ Upper**, in bpm.
|
||||
Each limit has large **− / +** touch buttons that adjust the value in
|
||||
**5 bpm steps** (range 0–240), plus an **OFF** button to disable it.
|
||||
When disabled, an **ON** button restores its previous value (or 60 bpm
|
||||
for an unset lower limit and 100 bpm for an unset upper limit).
|
||||
The lower limit must not exceed the upper limit.
|
||||
- **Apply** commits lead and limits together; **Cancel** or **Esc** discards
|
||||
unsaved changes. Both Admin and monitor displays reflect committed changes.
|
||||
Changing limits in the monitor marks the Admin alarm preset as **Custom**.
|
||||
|
||||
The menu uses light-grey text instead of the ECG waveform color and
|
||||
subtle separators matching the main monitor divider thickness. No keyboard
|
||||
is required for the ECG menu; the Admin window retains numeric text inputs.
|
||||
|
||||
The Admin ECG section also includes an ECG-lead selector, synchronized with
|
||||
changes made from the monitor. SpO₂, ART, CO₂ and NIBP now also have
|
||||
neutral, touch-operated settings panels (details below).
|
||||
|
||||
## Additional monitor touchscreen menus (v0.6.0)
|
||||
|
||||
Tap or click the **waveform or numeric readout** of SpO₂, ART or CO₂ to open
|
||||
that channel's settings panel. For NIBP, tap the **rightmost quarter of the
|
||||
bottom measurement row**. The CO/CI, SVRI/GEDI/ELWI and unused third cells
|
||||
remain non-interactive. All menus share the ECG menu's **black background,
|
||||
light-grey text and thin 0.8 px dividers**. No on-monitor keyboard is needed.
|
||||
|
||||
| Touched channel | Alarm thresholds | Other touch settings |
|
||||
| Touch area | Available alarm limits | Increment |
|
||||
| --- | --- | --- |
|
||||
| SpO₂ | SpO₂, PR | Signal quality; sensor attached/detached |
|
||||
| ART | SYS, MAP, DIA, PPV | Arterial waveform shape |
|
||||
| CO₂ | EtCO₂, RR | Normal or obstructive capnogram |
|
||||
| NIBP | SYS, MAP, DIA | 1/3/5/10/20/30/60-minute interval, Auto ON/OFF, simulated failed reading, cuff extremity, **Measure now** |
|
||||
| ECG | HR | 5 bpm |
|
||||
| SpO₂ | SpO₂; pulse rate (PR) | 1% SpO₂; 5 bpm PR |
|
||||
| ART | SYS; MAP; DIA; PPV | 5 mmHg pressure; 1% PPV |
|
||||
| CO₂ | EtCO₂; respiratory rate (RR) | 1 mmHg EtCO₂; 1 breath/min RR |
|
||||
| NIBP | SYS; MAP; DIA | 5 mmHg |
|
||||
|
||||
Each independent alarm bound is changed via large **−/+** buttons and
|
||||
**ON/OFF**. Touch increments are appropriate for the measurement: 5 bpm for
|
||||
PR; 1% for SpO₂ and PPV; 5 mmHg for ART and NIBP; 1 mmHg for EtCO₂; and
|
||||
1 breath/min for RR. Lower bounds must not exceed upper bounds.
|
||||
**Apply** commits the threshold changes and synchronizes the Admin window.
|
||||
Changing a threshold sets the alarm preset to **Custom**. **Cancel** or
|
||||
**Esc** discards the draft changes.
|
||||
|
||||
**Apply** commits the settings and updates the Admin controls and selected
|
||||
alarm preset (**Custom** if limits were changed). **Cancel** discards edits;
|
||||
**Esc** closes the panel. **Measure now** is an immediate action and starts
|
||||
an NIBP cuff cycle independently of Apply, using the currently active
|
||||
simulation settings. Apply other changed settings first if they should affect
|
||||
the next manual measurement.
|
||||
ECG lead selection, SpO₂ signal quality and sensor status, ART waveform shape,
|
||||
capnogram shape, and all NIBP measurement controls are **Admin-only**. This
|
||||
includes NIBP measurement interval, Auto ON/OFF, **Measure now**, simulated
|
||||
failed reading, and cuff placement. None of these physiological or technical
|
||||
parameters is changed by the monitor-side alarm menus.
|
||||
|
||||
### NIBP startup and automatic measurements
|
||||
|
||||
**Auto measurement is OFF by default.** The monitor displays `---/---`
|
||||
(MAP `---`) on startup, and there is **no automatic first measurement**.
|
||||
A first result appears only after selecting **Measure now**, or after
|
||||
activating **Automatic measurement** from the NIBP touch menu (also available
|
||||
in Admin). When Auto is first enabled, a measurement starts immediately;
|
||||
thereafter the selected interval counts from completion of the previous cycle.
|
||||
Switching Auto off prevents future scheduled cycles but **does not interrupt
|
||||
a cycle already under way**. Manual measurements can always be initiated
|
||||
when no cycle is running, even with Auto OFF. While Auto is OFF, the NIBP
|
||||
interval bar is empty and the display says `AUTO OFF`.
|
||||
**Auto measurement is OFF by default.** On startup the monitor shows
|
||||
`---/---` (MAP `---`) and no measurement is initiated. To obtain a reading,
|
||||
select **Measure now** in Admin, or enable **Automatic NIBP measurement**
|
||||
there. The first automatic cycle begins immediately after enabling Auto;
|
||||
subsequent measurement intervals count from completion of the prior cycle.
|
||||
Disabling Auto stops further scheduled measurements without interrupting a
|
||||
cycle already in progress. Manual measurement remains possible while Auto
|
||||
is off. The interval bar is empty and the monitor displays `AUTO OFF`
|
||||
whenever automatic measurements are disabled.
|
||||
|
||||
## Chest compressions (v0.5.4)
|
||||
|
||||
|
|
@ -630,3 +600,11 @@ synchronized with Admin. NIBP additionally provides interval selection,
|
|||
manual **Measure now**, Auto ON/OFF and cuff options. Startup no longer
|
||||
initiates a cuff cycle or shows any NIBP reading; Auto is OFF by default.
|
||||
Existing NIBP cycle physics and signal quality behavior are unchanged.
|
||||
|
||||
### v0.6.1 — Alarm-only monitor touch menus
|
||||
|
||||
The ECG, SpO₂, ART, CO₂ and NIBP touch menus now edit only lower/upper
|
||||
alarm limits. Removed ECG lead, signal/sensor, waveform and all NIBP
|
||||
measurement controls from monitor-side menus. These remain available in
|
||||
Admin, including manual NIBP measurement and Auto ON/OFF. No physiological
|
||||
model, alarm evaluation or NIBP startup behavior was changed.
|
||||
|
|
|
|||