v0.5.0: tweak NIBP
This commit is contained in:
parent
e831364e43
commit
ef269099bd
12 changed files with 2900 additions and 109 deletions
1526
patient-monitor-simulation-v0.4.4-to-v0.5.0.patch
Normal file
1526
patient-monitor-simulation-v0.4.4-to-v0.5.0.patch
Normal file
File diff suppressed because it is too large
Load diff
2
patient-monitor-simulation/Cargo.lock
generated
2
patient-monitor-simulation/Cargo.lock
generated
|
|
@ -438,7 +438,7 @@ dependencies = [
|
||||||
|
|
||||||
[[package]]
|
[[package]]
|
||||||
name = "patient-monitor-simulation"
|
name = "patient-monitor-simulation"
|
||||||
version = "0.4.4"
|
version = "0.5.0"
|
||||||
dependencies = [
|
dependencies = [
|
||||||
"gtk4",
|
"gtk4",
|
||||||
]
|
]
|
||||||
|
|
|
||||||
|
|
@ -1,6 +1,6 @@
|
||||||
[package]
|
[package]
|
||||||
name = "patient-monitor-simulation"
|
name = "patient-monitor-simulation"
|
||||||
version = "0.4.4"
|
version = "0.5.0"
|
||||||
edition = "2021"
|
edition = "2021"
|
||||||
license = "MIT"
|
license = "MIT"
|
||||||
description = "Synthetic patient-monitor simulation for teaching (not for clinical use)"
|
description = "Synthetic patient-monitor simulation for teaching (not for clinical use)"
|
||||||
|
|
|
||||||
306
patient-monitor-simulation/README.de.md
Normal file
306
patient-monitor-simulation/README.de.md
Normal file
|
|
@ -0,0 +1,306 @@
|
||||||
|
# Patient Monitor Simulation (PaMSim) — v0.4.4
|
||||||
|
|
||||||
|
Ein mit Rust und GTK4 entwickelter Patient*innenmonitor-Simulator mit zwei Fenstern für die Lehre unter Fedora Linux.
|
||||||
|
|
||||||
|
> **Ausschließlich synthetische Trainingssignale — nicht für die klinische Anwendung.**
|
||||||
|
> EKG, invasive arterielle Druckkurve, Plethysmogramm und Kapnogramm sind schematische mathematische Annäherungen.
|
||||||
|
> Die Simulation wurde nicht klinisch validiert und ist kein Medizinprodukt.
|
||||||
|
|
||||||
|
## Installation, Kompilierung und Start unter Fedora
|
||||||
|
|
||||||
|
```bash
|
||||||
|
sudo dnf install rust cargo gcc pkgconf-pkg-config gtk4-devel
|
||||||
|
cargo test
|
||||||
|
cargo run --release
|
||||||
|
```
|
||||||
|
|
||||||
|
Die Befehle sind im entpackten Verzeichnis `patient-monitor-simulation` auszuführen.
|
||||||
|
Die Fenstertitel zeigen die Anwendungsversion an.
|
||||||
|
GTK4 benötigt eine funktionsfähige grafische Sitzung, beispielsweise Fedora KDE unter Wayland.
|
||||||
|
|
||||||
|
## Fenster
|
||||||
|
|
||||||
|
**Admin-Bereiche:** Links neben jeder Parametergruppe befindet sich ein schmaler Farbstreifen, dessen Farbe der jeweiligen Darstellung am Monitor entspricht: EKG **grün**, SpO₂ **gelb**, invasiver arterieller Blutdruck **rot**, Kapnographie **hellgrau** und NIBP **hellgrau**.
|
||||||
|
Der Bereich für Patientendaten bleibt neutral.
|
||||||
|
Die Farbstreifen werden von GTK dargestellt und sind unabhängig vom hellen bzw. dunklen Design sichtbar.
|
||||||
|
Die Änderung betrifft ausschließlich die Darstellung; die Funktion der Bedienelemente bleibt unverändert.
|
||||||
|
|
||||||
|
**Admin-Fenster:** Hier werden Patientenname, EKG-Rhythmus und Herzfrequenz, mechanische Pulsübertragung, SpO₂, Signalqualität und Sensoranschluss, invasiver arterieller Blutdruck, Kurvenform und Pulsdruckvariation, NIBP sowie Kapnographie eingestellt.
|
||||||
|
Numerische Eingabefelder und Schieberegler sind bidirektional gekoppelt: Änderungen am einen Bedienelement werden unmittelbar im anderen übernommen.
|
||||||
|
Jeder der fünf Monitorbereiche (EKG, SpO₂/Plethysmographie, ART, CO₂, NIBP) verfügt über ein eigenes Kontrollkästchen **Show on monitor**.
|
||||||
|
|
||||||
|
**Monitorfenster:** Schwarzer Hintergrund mit grünem EKG, gelbem Plethysmogramm, roter arterieller Druckkurve und hellgrauem Kapnogramm.
|
||||||
|
Der im Admin-Fenster eingegebene Patientenname ersetzt sofort die Überschrift **PATIENT MONITOR**.
|
||||||
|
Bei leerem Namensfeld wird wieder die allgemeine Überschrift angezeigt.
|
||||||
|
Lange Namen werden an die verfügbare Breite angepasst oder abgeschnitten.
|
||||||
|
Wird die Sichtbarkeit eines Parameters deaktiviert, verschwinden sowohl seine Kurve als auch die zugehörigen Messwerte.
|
||||||
|
Die verbleibenden Kurvenbereiche vergrößern sich entsprechend.
|
||||||
|
Das Ausblenden eines Monitorbereichs unterbricht **nicht** die Signalerzeugung oder physiologische Kopplung: Wird beispielsweise das EKG ausgeblendet, können arterielle und plethysmographische Pulse weiterhin auftreten.
|
||||||
|
NIBP kann unabhängig ausgeblendet werden; dabei verschwindet auch der zugehörige Bereich am unteren Fensterrand.
|
||||||
|
|
||||||
|
Das Monitorfenster lässt sich in der Größe verändern.
|
||||||
|
Mit **F11** wird der Vollbildmodus aktiviert bzw. umgeschaltet, mit **Esc** wird er verlassen.
|
||||||
|
Unter Wayland sollte das Fenster vor dem Wechsel in den Vollbildmodus auf den gewünschten Präsentationsbildschirm verschoben werden.
|
||||||
|
Der Vollbildmodus sperrt den Computer nicht gegen andere Eingaben.
|
||||||
|
|
||||||
|
## Numerische Alarmgrenzen (seit v0.4.0; Anordnung und Voreinstellungen seit v0.4.1)
|
||||||
|
|
||||||
|
Für jeden angezeigten numerischen Messwert können im zugehörigen Admin-Bereich **unabhängige optionale untere (↓) und obere (↑) Alarmgrenzen** festgelegt werden.
|
||||||
|
Die Eingabefelder für die Grenzwerte befinden sich **in derselben Zeile wie der entsprechende Schieberegler**.
|
||||||
|
Abgeleitete Werte ohne eigenen Schieberegler (PR, ART-MAP, NIBP-MAP) haben kompakte separate Alarmzeilen.
|
||||||
|
Das Admin-Fenster ist für diese zusätzlichen Bedienelemente breiter ausgelegt.
|
||||||
|
|
||||||
|
Die Grenzwerte werden als Text eingegeben.
|
||||||
|
Ein **leeres Feld** (angezeigt als `off`) deaktiviert nur die betreffende Grenze.
|
||||||
|
Sind beide Felder leer, ist der numerische Alarm für diesen Messwert vollständig deaktiviert.
|
||||||
|
Ein Messwert, der genau auf einer Grenze liegt, löst keinen Alarm aus; nur Werte **unterhalb** der unteren bzw. **oberhalb** der oberen Grenze gelten als außerhalb des erlaubten Bereichs.
|
||||||
|
Sind beide Grenzen eingetragen, darf die untere Grenze die obere nicht überschreiten.
|
||||||
|
Ungültige Eingaben werden hervorgehoben; die letzte gültige Einstellung bleibt wirksam.
|
||||||
|
|
||||||
|
| Monitorbereich | Unabhängig einstellbare Alarmgrenzen |
|
||||||
|
| --- | --- |
|
||||||
|
| EKG | Herzfrequenz (HR) |
|
||||||
|
| SpO₂ | Sauerstoffsättigung (SpO₂), abgeleitete Pulsfrequenz (PR) |
|
||||||
|
| Invasiver arterieller Blutdruck (ART) | Systolischer (SYS), mittlerer (MAP), diastolischer Druck (DIA), PPV |
|
||||||
|
| NIBP | Systolischer (SYS), mittlerer (MAP), diastolischer Druck (DIA) |
|
||||||
|
| Kapnographie | Endtidales CO₂ (EtCO₂), Atemfrequenz (RR) |
|
||||||
|
|
||||||
|
Die aktuell eingestellten Grenzwerte erscheinen in kleiner Schrift **rechts oben** im jeweiligen Monitorbereich.
|
||||||
|
Pfeile kennzeichnen die Richtung der Grenze.
|
||||||
|
Eine deaktivierte Grenze wird als `---` dargestellt, beispielsweise:
|
||||||
|
|
||||||
|
```text
|
||||||
|
⚠ SYS ↓80 ↑180
|
||||||
|
MAP ↓60 ↑---
|
||||||
|
DIA ↓--- ↑---
|
||||||
|
```
|
||||||
|
|
||||||
|
### Alarmvoreinstellungen (Alert presets)
|
||||||
|
|
||||||
|
Das Auswahlmenü **Alert presets** oben im Admin-Fenster bietet die Einträge **Custom** (manuelle Einstellung) und **Adult** (Erwachsene).
|
||||||
|
Die Auswahl **Adult** übernimmt sofort alle zugehörigen Alarmgrenzen und aktualisiert die Eingabefelder neben den Schiebereglern.
|
||||||
|
**Nur die Alarmgrenzen ändern sich**: Herzfrequenz, Blutdruck, Sichtbarkeit der Monitorbereiche und andere simulierte physiologische Parameter bleiben unverändert.
|
||||||
|
Wird nach Auswahl von Adult eine Alarmgrenze manuell verändert, wechselt das Menü automatisch zu **Custom**, ohne die übrigen Grenzen zu verändern.
|
||||||
|
Durch erneute Auswahl von **Adult** wird die vollständige Voreinstellung wiederhergestellt.
|
||||||
|
|
||||||
|
| Parameter | Untere Grenze | Obere Grenze |
|
||||||
|
| --- | ---: | ---: |
|
||||||
|
| HR (bpm) | 60 | 100 |
|
||||||
|
| SpO₂ (%) | 90 | --- |
|
||||||
|
| PR (bpm) | --- | --- |
|
||||||
|
| ART SYS (mmHg) | 80 | 180 |
|
||||||
|
| ART MAP (mmHg) | 60 | 100 |
|
||||||
|
| ART DIA (mmHg) | --- | --- |
|
||||||
|
| PPV (%) | --- | 10 |
|
||||||
|
| NIBP SYS (mmHg) | 80 | 180 |
|
||||||
|
| NIBP MAP (mmHg) | 60 | 100 |
|
||||||
|
| NIBP DIA (mmHg) | --- | --- |
|
||||||
|
| EtCO₂ (mmHg) | 30 | 50 |
|
||||||
|
| RR (/min) | 10 | 20 |
|
||||||
|
|
||||||
|
`---` bedeutet, dass die jeweilige Alarmgrenze deaktiviert ist.
|
||||||
|
Die Voreinstellung Adult dient **ausschließlich der Lehre** und stellt keine klinisch validierte Grenzwertkonfiguration dar.
|
||||||
|
Beim Programmstart ist **Custom** ausgewählt; sämtliche Grenzen sind zunächst deaktiviert (wie in v0.4.0).
|
||||||
|
|
||||||
|
Verletzt ein Messwert eine aktivierte Alarmgrenze, **blinkt ausschließlich der betroffene Zahlenwert durch abwechselnde Invertierung von Vorder- und Hintergrundfarbe** (500 ms invertiert / 500 ms normal).
|
||||||
|
SYS, DIA, MAP und die PPV-Anzeige blinken jeweils unabhängig voneinander.
|
||||||
|
Die Kurve selbst bleibt unverändert.
|
||||||
|
Standardmäßig sind alle numerischen Alarme deaktiviert, damit bestehende Unterrichtsszenarien nicht unerwartet blinken.
|
||||||
|
|
||||||
|
Numerische Grenzwertalarme werden nur für tatsächlich verfügbare Messwerte ausgewertet.
|
||||||
|
`--`, `NO SENSOR` und andere nicht verfügbare Anzeigen lösen keine numerischen Untergrenzenalarme aus.
|
||||||
|
Die aus dem EKG abgeleitete Pulsfrequenz und die Sichtbarkeit der Signale funktionieren weiterhin wie in v0.3.2.
|
||||||
|
Alarme sind derzeit rein visuell: Es gibt **keine akustischen Alarme, Alarmspeicherung bis zur Quittierung, Prioritätsklassifizierung oder klinische Alarmvalidierung**.
|
||||||
|
Die Einstellungen bleiben nur während der laufenden Programmsitzung erhalten und werden beim Neustart zurückgesetzt.
|
||||||
|
|
||||||
|
## Patientenname und Signalstatus des Pulsoxymeters (seit v0.3.2)
|
||||||
|
|
||||||
|
Das Feld **Patient name** oben im Admin-Fenster ersetzt die Monitorüberschrift unmittelbar durch den eingegebenen Namen.
|
||||||
|
Das Feld ist optional; bei leerer oder ausschließlich aus Leerzeichen bestehender Eingabe erscheint **PATIENT MONITOR**.
|
||||||
|
Der Name dient nur zur Kennzeichnung des Unterrichtsszenarios; es handelt sich nicht um eine Patientenakte.
|
||||||
|
|
||||||
|
Unter Admin → **Pulse oximetry** stehen zwei zusätzliche Einstellungen zur Verfügung:
|
||||||
|
|
||||||
|
- **Sensor not attached** (Kontrollkästchen): Entfernt unmittelbar das Plethysmogramm, unterdrückt SpO₂- und Pulsfrequenzwerte und zeigt **NO SENSOR** anstelle der numerischen Sättigung.
|
||||||
|
Dieser Zustand hat Vorrang vor der eingestellten Signalqualität.
|
||||||
|
- **Signal quality** (Auswahlmenü): Verändert die sichtbare Plethysmogrammform und den Qualitätsindikator unabhängig vom eingestellten SpO₂-Prozentwert.
|
||||||
|
|
||||||
|
| Einstellung | Plethysmogramm | Monitoranzeige |
|
||||||
|
| --- | --- | --- |
|
||||||
|
| **0 — None** | Keine Kurve | Blinkendes **NO READING**, PR `--`; keine Sterne |
|
||||||
|
| **1 — Poor** | Kleine, unregelmäßig verzerrte Pulse mit zeitweiligen Signalausfällen | 1 Stern (★), solange ein Signal vorhanden ist; blinkendes **NO READING** während des Ausfalls |
|
||||||
|
| **2 — Adequate** | Mittlere Amplitude, geglättete und gedämpfte Pulse | 2 Sterne (★★) |
|
||||||
|
| **3 — Good** | Volle nominelle Amplitude, geglättete und gedämpfte Pulse | 3 Sterne (★★★) |
|
||||||
|
|
||||||
|
Standardeinstellung: Sensor angeschlossen und Signalqualität **3 — Good**.
|
||||||
|
Bei den Qualitätsstufen 1–3 wird der eingestellte SpO₂-Wert nur angezeigt, wenn mechanische Pulse erkannt werden.
|
||||||
|
|
||||||
|
Bei **Poor** treten zusätzlich wiederholte vollständige Signalausfälle auf: Zwischen den Unterbrechungen liegen **30–180 Sekunden** mit verwertbarem, aber qualitativ schlechtem Signal; jede Unterbrechung dauert **5–20 Sekunden**.
|
||||||
|
Während eines Ausfalls verschwindet die Plethysmogrammkurve, SpO₂ und PR sind nicht verfügbar und **NO READING** blinkt.
|
||||||
|
Nach Ende des Ausfalls kehren das Poor-Signal und die numerischen Werte automatisch zurück.
|
||||||
|
Die Intervalle werden pseudozufällig anhand der Simulationszeit bestimmt und sind unabhängig von der Bildwiederholrate.
|
||||||
|
Beim erneuten Auswählen von Poor beginnt die Intervallfolge von vorn.
|
||||||
|
|
||||||
|
Ein Signalausfall beeinflusst weder die eingestellte Sauerstoffsättigung noch das EKG, die Erzeugung mechanischer Pulse oder die arterielle Druckkurve.
|
||||||
|
Die simulierte Pulsfrequenz wird weiterhin aus mechanisch wirksamen QRS-Komplexen abgeleitet.
|
||||||
|
Das gestörte Plethysmogramm verwendet deterministisches, weich interpoliertes Pseudorauschen, das ausschließlich bereits vorhandene Pulse moduliert.
|
||||||
|
Es erzeugt daher keine künstlichen Pulse bei PEA, PVT, Kammerflimmern oder Asystolie.
|
||||||
|
Bei abgezogenem Sensor oder Signalqualität 0 werden auch zuvor gepufferte Plethysmogrammwerte sofort ausgeblendet.
|
||||||
|
EKG und ART bleiben unbeeinflusst.
|
||||||
|
Das Kontrollkästchen **Show on monitor** blendet weiterhin den vollständigen SpO₂-Monitorbereich aus; Sensor- und Qualitätszustände lassen den Bereich dagegen sichtbar, damit die Statusmeldungen im Unterricht demonstriert werden können.
|
||||||
|
|
||||||
|
## EKG und mechanische Pulskopplung
|
||||||
|
|
||||||
|
- **EKG-Rhythmen:** Sinusrhythmus, Vorhofflimmern, monomorphe ventrikuläre Tachykardie (VT; potenziell mit mechanischer Perfusion), pulslose ventrikuläre Tachykardie (PVT), Kammerflimmern (VF) und Asystolie.
|
||||||
|
- **Mechanische Pulsübertragung:** **1:1**, **2:1**, **3:1**, **None (PEA)** oder deterministisch pseudozufällige Übertragung (ca. 65 %).
|
||||||
|
Die Pulsfrequenz (PR) wird aus mechanisch wirksamen QRS-Ereignissen abgeleitet; ein eigener Pulsfrequenz-Schieberegler existiert nicht.
|
||||||
|
- Ein mechanisch wirksamer QRS-Komplex löst nach modellhaften **120 ms** einen arteriellen Druckanstieg und nach **300 ms** einen peripheren Plethysmogrammpuls aus.
|
||||||
|
Das Plethysmogramm wird stark gedämpft und gefiltert dargestellt.
|
||||||
|
- Bei Auswahl von VT oder PVT wird die Herzfrequenz zunächst auf **160 bpm** gesetzt und sowohl im Schieberegler als auch im numerischen Feld aktualisiert.
|
||||||
|
Eine anschließende manuelle Änderung ist möglich.
|
||||||
|
- PVT, VF, Asystolie und PEA unterdrücken mechanische Pulse.
|
||||||
|
Die ART-Kurve schwankt dann langsam zwischen **0 und 5 mmHg**, statt pulsatile Drücke darzustellen.
|
||||||
|
Der ART-**SYS**-Wert zeigt den gerundeten niedrigen Transducerdruck (0–5 mmHg).
|
||||||
|
DIA und MAP zeigen `--`, weil sie nicht zuverlässig bestimmt werden können.
|
||||||
|
Frühere Druckwerte laufen mit dem Signalverlauf aus dem Sichtfenster.
|
||||||
|
NIBP ist ein unabhängig eingestellter, statischer Manschettenmesswert.
|
||||||
|
|
||||||
|
## Invasiver arterieller Blutdruck und PPV (seit v0.3)
|
||||||
|
|
||||||
|
Die arterielle Druckkurve hat eine feste Skala von **0–200 mmHg** mit Markierungen bei **0, 50, 100, 150 und 200 mmHg**.
|
||||||
|
Die eingestellten nominellen systolischen und diastolischen ART-Werte sind auf 0–200 mmHg begrenzt.
|
||||||
|
|
||||||
|
Die **Pulsdruckvariation (PPV)** ist im Bereich **0–60 %** in Schritten von 1 % über einen gekoppelten Schieberegler und ein Textfeld einstellbar (Admin → Invasive arterial blood pressure).
|
||||||
|
Standardwert ist **0 %**, also keine respiratorische Modulation.
|
||||||
|
Der Atemzyklus wird aus demselben Atemfrequenzparameter wie das Kapnogramm erzeugt.
|
||||||
|
**RR = 0** deaktiviert die respiratorische Modulation (Apnoe).
|
||||||
|
|
||||||
|
Die synthetische PPV-Definition lautet:
|
||||||
|
|
||||||
|
```text
|
||||||
|
PPV (%) = 100 × (PPmax − PPmin) / ((PPmax + PPmin) / 2)
|
||||||
|
```
|
||||||
|
|
||||||
|
Das Modell moduliert den **Pulsdruck** sinusförmig; die Modulation wird für jeden mechanisch wirksamen Herzschlag gesondert bestimmt.
|
||||||
|
Der diastolische Ausgangsdruck bleibt nominell konstant.
|
||||||
|
Es entsteht somit vor allem eine **atemabhängige systolische Schwankung von Schlag zu Schlag** und keine beliebige vertikale Verschiebung der gesamten Druckkurve.
|
||||||
|
Die Modulation beeinflusst weder das EKG noch die mechanische Pulsübertragung oder die Amplitude des Plethysmogramms.
|
||||||
|
Es handelt sich um ein Anschauungsmodell und nicht um ein validiertes Verfahren zur Vorhersage der Volumenreagibilität.
|
||||||
|
|
||||||
|
**Beispiel:** Ein arterieller Druck von 120/75 mmHg entspricht einem nominellen Pulsdruck von 45 mmHg.
|
||||||
|
Bei einer PPV von 20 % liegen die idealisierten Pulsdruckextrema bei 40,5 und 49,5 mmHg.
|
||||||
|
Bei unverändertem diastolischem Druck von 75 mmHg ergeben sich systolische Spitzen von etwa 115,5 bis 124,5 mmHg.
|
||||||
|
Aufgrund der Kurvenform und der endlichen Anzahl von Herzschlägen innerhalb eines Atemzyklus müssen die tatsächlich dargestellten Maxima die rechnerischen Extremwerte nicht exakt erreichen.
|
||||||
|
|
||||||
|
Der ART-Anzeigebereich zeigt die **nominellen** systolischen und diastolischen Druckwerte sowie den MAP und bei PPV über 0 den **eingestellten** PPV-Wert.
|
||||||
|
Die PPV wird nicht aus den abgetasteten Druckwerten berechnet.
|
||||||
|
Bei sehr hohen nominellen systolischen Drücken können modulierte Spitzen die Grenze von 200 mmHg überschreiten.
|
||||||
|
Die Kurve wird dann **am oberen Skalenende abgeschnitten**, ohne dass die Skala automatisch angepasst wird.
|
||||||
|
|
||||||
|
## Anzeigeoptionen (seit v0.3)
|
||||||
|
|
||||||
|
Die fünf Kontrollkästchen **Show on monitor** beeinflussen ausschließlich die Darstellung:
|
||||||
|
|
||||||
|
| Kontrollkästchen | Ausgeblendete Monitorinhalte |
|
||||||
|
| --- | --- |
|
||||||
|
| ECG | EKG-Kurve, Herzfrequenz und ggf. Rhythmusalarm |
|
||||||
|
| Pulse oximetry | Plethysmogramm, SpO₂ und PR |
|
||||||
|
| Invasive arterial blood pressure | ART-Kurve, Druckwerte, MAP und PPV-Anzeige |
|
||||||
|
| Capnography | CO₂-Kurve, EtCO₂ und Atemfrequenz |
|
||||||
|
| NIBP | Statische Manschettendruckwerte und NIBP-Anzeige am unteren Fensterrand |
|
||||||
|
|
||||||
|
Die verbleibenden Kurven behalten ihre Reihenfolge bei und teilen sich die verfügbare Höhe gleichmäßig.
|
||||||
|
Auch eine Anzeige ohne sichtbare Kurvenbereiche wird unterstützt.
|
||||||
|
|
||||||
|
## Korrektur der EKG-Morphologie (v0.3.1)
|
||||||
|
|
||||||
|
In der früheren EKG-Simulation wurde die QRS-Breite als fester Anteil des RR-Intervalls definiert und mit 100 Hz abgetastet.
|
||||||
|
Bei hohen Herzfrequenzen konnten schmale R-Zacken zwischen die Abtastpunkte fallen.
|
||||||
|
Dadurch schwankte die dargestellte QRS-Amplitude von Schlag zu Schlag stark, obwohl ein regelmäßiger Sinusrhythmus vorlag.
|
||||||
|
|
||||||
|
- Die Breiten der synthetischen P-, QRS- und T-Komponenten werden jetzt in **Millisekunden** und nicht als fixe Anteile des Herzzyklus definiert.
|
||||||
|
Lage und Breite von P- und T-Wellen passen sich dem RR-Intervall an, während die QRS-Dauer weitgehend konstant bleibt.
|
||||||
|
- Die Abtastfrequenz wurde auf **250 Hz** (4-ms-Abstände) erhöht, um R-Zacken auch bei **189–240 bpm** zuverlässiger zu erfassen.
|
||||||
|
- Die EKG-Morphologie ist unabhängig von der respiratorischen PPV-Einstellung.
|
||||||
|
Die Verzögerungen für arterielle und plethysmographische Pulse sowie die Optionen für die mechanische Pulsübertragung bleiben unverändert.
|
||||||
|
- Regressionstests vergleichen die R-Zacken-Amplituden bei 60, 75, 120, 189 und 240 bpm und prüfen, dass Änderungen der PPV das EKG-Signal nicht beeinflussen.
|
||||||
|
|
||||||
|
Das EKG bleibt ein schematisches Lehrsignal.
|
||||||
|
Eine Spannungskalibrierung, ein Modell zur Elektrodenpositionierung, diagnostische Kriterien oder eine patientenspezifische Physiologie werden nicht simuliert.
|
||||||
|
|
||||||
|
## Technische Signalimplementierung
|
||||||
|
|
||||||
|
- Synthetische Signale mit **250 Hz** Abtastfrequenz, **10 Sekunden** gespeichertem Signalverlauf und **8 Sekunden** sichtbarer, fortlaufender Kurve.
|
||||||
|
- Cairo zeichnet in eine GTK4-`DrawingArea`; die Anzeige skaliert mit der Fenstergröße.
|
||||||
|
- Jeder mechanisch wirksame QRS-Komplex erhält beim Ereignis einen eigenen respiratorischen PPV-Multiplikator.
|
||||||
|
Dadurch bleibt die Amplitude des zugehörigen arteriellen Pulsschlags während des gesamten Schlags konsistent.
|
||||||
|
- Änderungen der PPV beeinflussen weder den peripheren Plethysmogrammpuls noch die Anzahl mechanischer Pulse.
|
||||||
|
- Klinisch exakte Physiologie, dynamische NIBP-Messzyklen, akustische bzw. weitergehende Alarmfunktionen, Artefaktmodelle, Kalibrierung und präzise physiologische Signallaufzeiten sind nicht Bestandteil dieses Prototyps.
|
||||||
|
|
||||||
|
## Projektstruktur
|
||||||
|
|
||||||
|
```text
|
||||||
|
src/
|
||||||
|
main.rs Einstiegspunkt der GTK-Anwendung
|
||||||
|
model.rs Parameter, Rhythmus-/Pulsübertragung, Anzeigeoptionen
|
||||||
|
simulation.rs QRS-gesteuerte mechanische Signale, PPV und Atemsimulation
|
||||||
|
render.rs Cairo-Monitordarstellung, dynamische Sichtbarkeit, feste ART-Skala
|
||||||
|
ui.rs Admin-Bedienelemente und Monitorfenster
|
||||||
|
```
|
||||||
|
|
||||||
|
## Änderungen seit v0.2.2
|
||||||
|
|
||||||
|
1. Respiratorische PPV mit einstellbarem Bereich von 0–60 %, gekoppelt an den simulierten Atemzyklus und **pro arteriellem Pulsschlag** angewendet.
|
||||||
|
2. Fünf unabhängige Schalter für die Sichtbarkeit, dynamische Aufteilung der Kurvenbereiche und unabhängiges Ausblenden des NIBP-Bereichs.
|
||||||
|
3. ART-Skala von **0–250** auf **0–200 mmHg** reduziert und Eingabebereiche angepasst.
|
||||||
|
4. Regressionstests für die PPV-Berechnung und ihre Auswirkungen auf ART, das Ausblenden des EKG bei weiterhin vorhandenen mechanischen Pulsen, die Auswahl aktiver Monitorbereiche und die Normierung der arteriellen Druckskala ergänzt.
|
||||||
|
|
||||||
|
**Überprüfung:** Das Archiv wurde aus diesen Quelldateien erstellt.
|
||||||
|
Zur Überprüfung des Rust-/GTK-Builds bitte `cargo test` lokal ausführen.
|
||||||
|
Rust und die GTK4-Entwicklungskomponenten waren in der Umgebung, in der das ZIP-Archiv erstellt wurde, nicht verfügbar.
|
||||||
|
|
||||||
|
## Änderungen in v0.3.2
|
||||||
|
|
||||||
|
1. Patientenname im Admin-Fenster ergänzt, der unmittelbar als Monitorüberschrift erscheint; bei leerem Feld wird die Standardüberschrift verwendet.
|
||||||
|
2. Vier Stufen der SpO₂-Signalqualität mit Qualitätssternen und unregelmäßigem, amplitudenreduziertem Plethysmogramm für Poor ergänzt.
|
||||||
|
3. **Sensor not attached** ergänzt: Anzeige `NO SENSOR` und Unterdrückung von SpO₂, PR und Plethysmogramm.
|
||||||
|
4. Tests für die Skalierung der Signalqualität, die angezeigten Messwerte und das Verhalten bei nicht angeschlossenem Sensor ergänzt.
|
||||||
|
|
||||||
|
**Build-Überprüfung:** ZIP-Integrität und Patch-Anwendung wurden überprüft.
|
||||||
|
Die GTK4-Anwendung und die Rust-Tests wurden in der Paketierungsumgebung nicht kompiliert.
|
||||||
|
Unter Fedora bitte `cargo test` und `cargo run --release` ausführen.
|
||||||
|
|
||||||
|
## v0.4.2 — Rhythmusalarme, Sensoralarme und fehlende Messwerte
|
||||||
|
|
||||||
|
- **VT** kann weiterhin mit mechanischer Perfusion einhergehen.
|
||||||
|
Der neue Rhythmus **PVT** (pulslose ventrikuläre Tachykardie) zeigt organisierte breite QRS-Komplexe, erzeugt jedoch keine arteriellen oder plethysmographischen Pulse.
|
||||||
|
Auch Kammerflimmern und Asystolie sind unabhängig von der gewählten Pulsübertragung pulslos.
|
||||||
|
- **EKG:** Blinkende Meldung **ARRHYTHMIA** bei VT, PVT und VF; blinkende Meldung **ASYSTOLE** bei Asystolie.
|
||||||
|
Diese Ereignisalarme sind unabhängig von den numerischen Herzfrequenzgrenzen.
|
||||||
|
- **SpO₂:** Bei abgezogenem Sensor ersetzt die blinkende Meldung **NO SENSOR** die Sauerstoffsättigung.
|
||||||
|
Signalqualität 0, Ausfall der mechanischen Pulsübertragung oder ein pulsloser Rhythmus führen zur blinkenden Meldung **NO READING** (ohne numerische SpO₂-/PR-Werte).
|
||||||
|
Ein abgezogener Sensor hat Vorrang.
|
||||||
|
In diesen Zuständen wird kein Plethysmogramm angezeigt.
|
||||||
|
- **ART:** Ohne mechanische Pulse (einschließlich PVT, VF, Asystolie und PEA) zeigt die invasive Druckkurve langsame nichtpulsatile Schwankungen zwischen **0 und 5 mmHg**.
|
||||||
|
In v0.4.2 zeigte die numerische Anzeige `--/--`; seit v0.4.3 wird im SYS-Feld der gerundete gemessene Druck von 0–5 mmHg angezeigt, während DIA und MAP `--` zeigen.
|
||||||
|
- Die **Bezeichnung des EKG-Rhythmus** wurde aus der Monitoranzeige entfernt.
|
||||||
|
Sichtbar sind nur Herzfrequenz und gegebenenfalls die zugehörige Alarmmeldung.
|
||||||
|
Der Rhythmus wird weiterhin im Admin-Fenster ausgewählt.
|
||||||
|
- Die numerischen Alarmgrenzen und die Adult-Voreinstellung aus v0.4.1 bleiben unverändert.
|
||||||
|
Sämtliches Verhalten dient ausschließlich der Demonstration und ist nicht für klinische Entscheidungen geeignet.
|
||||||
|
|
||||||
|
## v0.4.3 — Niedriger arterieller Druck, VT-Herzfrequenz und intermittierendes schlechtes SpO₂-Signal
|
||||||
|
|
||||||
|
- Bei pulslosen Rhythmen, PEA oder sonstigem Ausfall mechanischer Pulse zeigt ART SYS den **aktuell gemessenen Druck von 0–5 mmHg** an, zum Beispiel `3/--` und `MAP -- mmHg`.
|
||||||
|
**Nur SYS** wird gegen die konfigurierten ART-SYS-Grenzen geprüft.
|
||||||
|
Aus fehlenden MAP- oder DIA-Werten werden keine irreführenden Grenzwertalarme erzeugt.
|
||||||
|
- Die Auswahl von **VT** oder **PVT** im Admin-Fenster setzt die Herzfrequenz auf **160 bpm** und aktualisiert den zugehörigen Schieberegler und das Textfeld.
|
||||||
|
Danach kann die Frequenz manuell geändert werden.
|
||||||
|
VT mit mechanischer Perfusion erzeugt weiterhin QRS-gekoppelte Pulse entsprechend der eingestellten Pulsübertragung; PVT bleibt pulslos.
|
||||||
|
- Bei **Poor (★)** wechselt das SpO₂-Signal nach pseudozufälligen **30–180 Sekunden** mit nutzbarem, aber qualitativ schlechtem Signal für pseudozufällige **5–20 Sekunden** auf **NO READING**.
|
||||||
|
Der technische Alarm blinkt, SpO₂ und PR werden ausgeblendet und das Plethysmogramm verschwindet.
|
||||||
|
Anschließend kehrt das Signal automatisch zur Qualität Poor zurück.
|
||||||
|
In der simulierten Signalhistorie bleiben sichtbare Lücken für die Ausfälle erhalten.
|
||||||
|
Wird eine andere Signalqualität gewählt, endet der intermittierende Ausfall unmittelbar.
|
||||||
|
- Die Adult-Alarmvoreinstellungen, die Reihenfolge der Alarmgrenzen und die arterielle Skala von 0–200 mmHg bleiben unverändert.
|
||||||
|
Alle Funktionen sind synthetisch und ausschließlich für die Lehre bestimmt.
|
||||||
372
patient-monitor-simulation/README.de.md.rej
Normal file
372
patient-monitor-simulation/README.de.md.rej
Normal file
|
|
@ -0,0 +1,372 @@
|
||||||
|
--- README.de.md
|
||||||
|
+++ README.de.md
|
||||||
|
@@ -1,369 +0,0 @@
|
||||||
|
-# Patient Monitor Simulation (PaMSim) — v0.5.0
|
||||||
|
-
|
||||||
|
-Ein mit Rust und GTK4 entwickelter Patient*innenmonitor-Simulator mit zwei Fenstern für die Lehre unter Fedora Linux.
|
||||||
|
-
|
||||||
|
-> **Ausschließlich synthetische Trainingssignale — nicht für die klinische Anwendung.**
|
||||||
|
-> EKG, invasive arterielle Druckkurve, Plethysmogramm und Kapnogramm sind schematische mathematische Annäherungen.
|
||||||
|
-> Die Simulation wurde nicht klinisch validiert und ist kein Medizinprodukt.
|
||||||
|
-
|
||||||
|
-## Installation, Kompilierung und Start unter Fedora
|
||||||
|
-
|
||||||
|
-```bash
|
||||||
|
-sudo dnf install rust cargo gcc pkgconf-pkg-config gtk4-devel
|
||||||
|
-cargo test
|
||||||
|
-cargo run --release
|
||||||
|
-```
|
||||||
|
-
|
||||||
|
-Die Befehle sind im entpackten Verzeichnis `patient-monitor-simulation` auszuführen.
|
||||||
|
-Die Fenstertitel zeigen die Anwendungsversion an.
|
||||||
|
-GTK4 benötigt eine funktionsfähige grafische Sitzung, beispielsweise Fedora KDE unter Wayland.
|
||||||
|
-
|
||||||
|
-## Fenster
|
||||||
|
-
|
||||||
|
-**Admin-Bereiche:** Links neben jeder Parametergruppe befindet sich ein schmaler Farbstreifen, dessen Farbe der jeweiligen Darstellung am Monitor entspricht: EKG **grün**, SpO₂ **gelb**, invasiver arterieller Blutdruck **rot**, Kapnographie **hellgrau** und NIBP **rot**.
|
||||||
|
-Der Bereich für Patientendaten bleibt neutral.
|
||||||
|
-Die Farbstreifen werden von GTK dargestellt und sind unabhängig vom hellen bzw. dunklen Design sichtbar.
|
||||||
|
-Die Änderung betrifft ausschließlich die Darstellung; die Funktion der Bedienelemente bleibt unverändert.
|
||||||
|
-
|
||||||
|
-**Admin-Fenster:** Hier werden Patientenname, EKG-Rhythmus und Herzfrequenz, mechanische Pulsübertragung, SpO₂, Signalqualität und Sensoranschluss, invasiver arterieller Blutdruck, Kurvenform und Pulsdruckvariation, NIBP sowie Kapnographie eingestellt.
|
||||||
|
-Numerische Eingabefelder und Schieberegler sind bidirektional gekoppelt: Änderungen am einen Bedienelement werden unmittelbar im anderen übernommen.
|
||||||
|
-Jeder der fünf Monitorbereiche (EKG, SpO₂/Plethysmographie, ART, CO₂, NIBP) verfügt über ein eigenes Kontrollkästchen **Show on monitor**.
|
||||||
|
-
|
||||||
|
-**Monitorfenster:** Schwarzer Hintergrund mit grünem EKG, gelbem Plethysmogramm, roter arterieller Druckkurve und hellgrauem Kapnogramm.
|
||||||
|
-Der im Admin-Fenster eingegebene Patientenname ersetzt sofort die Überschrift **PATIENT MONITOR**.
|
||||||
|
-Bei leerem Namensfeld wird wieder die allgemeine Überschrift angezeigt.
|
||||||
|
-Lange Namen werden an die verfügbare Breite angepasst oder abgeschnitten.
|
||||||
|
-Wird die Sichtbarkeit eines Parameters deaktiviert, verschwinden sowohl seine Kurve als auch die zugehörigen Messwerte.
|
||||||
|
-Die verbleibenden Kurvenbereiche vergrößern sich entsprechend.
|
||||||
|
-Das Ausblenden eines Monitorbereichs unterbricht **nicht** die Signalerzeugung oder physiologische Kopplung: Wird beispielsweise das EKG ausgeblendet, können arterielle und plethysmographische Pulse weiterhin auftreten.
|
||||||
|
-NIBP kann unabhängig ausgeblendet werden; dabei verschwindet auch das separate rote Wertefeld in der rechten Monitorspalte.
|
||||||
|
-
|
||||||
|
-Das Monitorfenster lässt sich in der Größe verändern.
|
||||||
|
-Mit **F11** wird der Vollbildmodus aktiviert bzw. umgeschaltet, mit **Esc** wird er verlassen.
|
||||||
|
-Unter Wayland sollte das Fenster vor dem Wechsel in den Vollbildmodus auf den gewünschten Präsentationsbildschirm verschoben werden.
|
||||||
|
-Der Vollbildmodus sperrt den Computer nicht gegen andere Eingaben.
|
||||||
|
-
|
||||||
|
-## Numerische Alarmgrenzen (seit v0.4.0; Anordnung und Voreinstellungen seit v0.4.1)
|
||||||
|
-
|
||||||
|
-Für jeden angezeigten numerischen Messwert können im zugehörigen Admin-Bereich **unabhängige optionale untere (↓) und obere (↑) Alarmgrenzen** festgelegt werden.
|
||||||
|
-Die Eingabefelder für die Grenzwerte befinden sich **in derselben Zeile wie der entsprechende Schieberegler**.
|
||||||
|
-Abgeleitete Werte ohne eigenen Schieberegler (PR, ART-MAP, NIBP-MAP) haben kompakte separate Alarmzeilen.
|
||||||
|
-Das Admin-Fenster ist für diese zusätzlichen Bedienelemente breiter ausgelegt.
|
||||||
|
-
|
||||||
|
-Die Grenzwerte werden als Text eingegeben.
|
||||||
|
-Ein **leeres Feld** (angezeigt als `off`) deaktiviert nur die betreffende Grenze.
|
||||||
|
-Sind beide Felder leer, ist der numerische Alarm für diesen Messwert vollständig deaktiviert.
|
||||||
|
-Ein Messwert, der genau auf einer Grenze liegt, löst keinen Alarm aus; nur Werte **unterhalb** der unteren bzw. **oberhalb** der oberen Grenze gelten als außerhalb des erlaubten Bereichs.
|
||||||
|
-Sind beide Grenzen eingetragen, darf die untere Grenze die obere nicht überschreiten.
|
||||||
|
-Ungültige Eingaben werden hervorgehoben; die letzte gültige Einstellung bleibt wirksam.
|
||||||
|
-
|
||||||
|
-| Monitorbereich | Unabhängig einstellbare Alarmgrenzen |
|
||||||
|
-| --- | --- |
|
||||||
|
-| EKG | Herzfrequenz (HR) |
|
||||||
|
-| SpO₂ | Sauerstoffsättigung (SpO₂), abgeleitete Pulsfrequenz (PR) |
|
||||||
|
-| Invasiver arterieller Blutdruck (ART) | Systolischer (SYS), mittlerer (MAP), diastolischer Druck (DIA), PPV |
|
||||||
|
-| NIBP | Systolischer (SYS), mittlerer (MAP), diastolischer Druck (DIA) |
|
||||||
|
-| Kapnographie | Endtidales CO₂ (EtCO₂), Atemfrequenz (RR) |
|
||||||
|
-
|
||||||
|
-Die aktuell eingestellten Grenzwerte erscheinen in kleiner Schrift **rechts oben** im jeweiligen Monitorbereich.
|
||||||
|
-Pfeile kennzeichnen die Richtung der Grenze.
|
||||||
|
-Eine deaktivierte Grenze wird als `---` dargestellt, beispielsweise:
|
||||||
|
-
|
||||||
|
-```text
|
||||||
|
-⚠ SYS ↓80 ↑180
|
||||||
|
- MAP ↓60 ↑---
|
||||||
|
- DIA ↓--- ↑---
|
||||||
|
-```
|
||||||
|
-
|
||||||
|
-### Alarmvoreinstellungen (Alert presets)
|
||||||
|
-
|
||||||
|
-Das Auswahlmenü **Alert presets** oben im Admin-Fenster bietet die Einträge **Custom** (manuelle Einstellung) und **Adult** (Erwachsene).
|
||||||
|
-Die Auswahl **Adult** übernimmt sofort alle zugehörigen Alarmgrenzen und aktualisiert die Eingabefelder neben den Schiebereglern.
|
||||||
|
-**Nur die Alarmgrenzen ändern sich**: Herzfrequenz, Blutdruck, Sichtbarkeit der Monitorbereiche und andere simulierte physiologische Parameter bleiben unverändert.
|
||||||
|
-Wird nach Auswahl von Adult eine Alarmgrenze manuell verändert, wechselt das Menü automatisch zu **Custom**, ohne die übrigen Grenzen zu verändern.
|
||||||
|
-Durch erneute Auswahl von **Adult** wird die vollständige Voreinstellung wiederhergestellt.
|
||||||
|
-
|
||||||
|
-| Parameter | Untere Grenze | Obere Grenze |
|
||||||
|
-| --- | ---: | ---: |
|
||||||
|
-| HR (bpm) | 60 | 100 |
|
||||||
|
-| SpO₂ (%) | 90 | --- |
|
||||||
|
-| PR (bpm) | --- | --- |
|
||||||
|
-| ART SYS (mmHg) | 80 | 180 |
|
||||||
|
-| ART MAP (mmHg) | 60 | 100 |
|
||||||
|
-| ART DIA (mmHg) | --- | --- |
|
||||||
|
-| PPV (%) | --- | 10 |
|
||||||
|
-| NIBP SYS (mmHg) | 80 | 180 |
|
||||||
|
-| NIBP MAP (mmHg) | 60 | 100 |
|
||||||
|
-| NIBP DIA (mmHg) | --- | --- |
|
||||||
|
-| EtCO₂ (mmHg) | 30 | 50 |
|
||||||
|
-| RR (/min) | 10 | 20 |
|
||||||
|
-
|
||||||
|
-`---` bedeutet, dass die jeweilige Alarmgrenze deaktiviert ist.
|
||||||
|
-Die Voreinstellung Adult dient **ausschließlich der Lehre** und stellt keine klinisch validierte Grenzwertkonfiguration dar.
|
||||||
|
-Beim Programmstart ist **Custom** ausgewählt; sämtliche Grenzen sind zunächst deaktiviert (wie in v0.4.0).
|
||||||
|
-
|
||||||
|
-Verletzt ein Messwert eine aktivierte Alarmgrenze, **blinkt ausschließlich der betroffene Zahlenwert durch abwechselnde Invertierung von Vorder- und Hintergrundfarbe** (500 ms invertiert / 500 ms normal).
|
||||||
|
-SYS, DIA, MAP und die PPV-Anzeige blinken jeweils unabhängig voneinander.
|
||||||
|
-Die Kurve selbst bleibt unverändert.
|
||||||
|
-Standardmäßig sind alle numerischen Alarme deaktiviert, damit bestehende Unterrichtsszenarien nicht unerwartet blinken.
|
||||||
|
-
|
||||||
|
-Numerische Grenzwertalarme werden nur für tatsächlich verfügbare Messwerte ausgewertet.
|
||||||
|
-`--`, `NO SENSOR` und andere nicht verfügbare Anzeigen lösen keine numerischen Untergrenzenalarme aus.
|
||||||
|
-Die aus dem EKG abgeleitete Pulsfrequenz und die Sichtbarkeit der Signale funktionieren weiterhin wie in v0.3.2.
|
||||||
|
-Alarme sind derzeit rein visuell: Es gibt **keine akustischen Alarme, Alarmspeicherung bis zur Quittierung, Prioritätsklassifizierung oder klinische Alarmvalidierung**.
|
||||||
|
-Die Einstellungen bleiben nur während der laufenden Programmsitzung erhalten und werden beim Neustart zurückgesetzt.
|
||||||
|
-
|
||||||
|
-## Patientenname und Signalstatus des Pulsoxymeters (seit v0.3.2)
|
||||||
|
-
|
||||||
|
-Das Feld **Patient name** oben im Admin-Fenster ersetzt die Monitorüberschrift unmittelbar durch den eingegebenen Namen.
|
||||||
|
-Das Feld ist optional; bei leerer oder ausschließlich aus Leerzeichen bestehender Eingabe erscheint **PATIENT MONITOR**.
|
||||||
|
-Der Name dient nur zur Kennzeichnung des Unterrichtsszenarios; es handelt sich nicht um eine Patientenakte.
|
||||||
|
-
|
||||||
|
-Unter Admin → **Pulse oximetry** stehen zwei zusätzliche Einstellungen zur Verfügung:
|
||||||
|
-
|
||||||
|
-- **Sensor not attached** (Kontrollkästchen): Entfernt unmittelbar das Plethysmogramm, unterdrückt SpO₂- und Pulsfrequenzwerte und zeigt **NO SENSOR** anstelle der numerischen Sättigung.
|
||||||
|
- Dieser Zustand hat Vorrang vor der eingestellten Signalqualität.
|
||||||
|
-- **Signal quality** (Auswahlmenü): Verändert die sichtbare Plethysmogrammform und den Qualitätsindikator unabhängig vom eingestellten SpO₂-Prozentwert.
|
||||||
|
-
|
||||||
|
-| Einstellung | Plethysmogramm | Monitoranzeige |
|
||||||
|
-| --- | --- | --- |
|
||||||
|
-| **0 — None** | Keine Kurve | Blinkendes **NO READING**, PR `--`; keine Sterne |
|
||||||
|
-| **1 — Poor** | Kleine, unregelmäßig verzerrte Pulse mit zeitweiligen Signalausfällen | 1 Stern (★), solange ein Signal vorhanden ist; blinkendes **NO READING** während des Ausfalls |
|
||||||
|
-| **2 — Adequate** | Mittlere Amplitude, geglättete und gedämpfte Pulse | 2 Sterne (★★) |
|
||||||
|
-| **3 — Good** | Volle nominelle Amplitude, geglättete und gedämpfte Pulse | 3 Sterne (★★★) |
|
||||||
|
-
|
||||||
|
-Standardeinstellung: Sensor angeschlossen und Signalqualität **3 — Good**.
|
||||||
|
-Bei den Qualitätsstufen 1–3 wird der eingestellte SpO₂-Wert nur angezeigt, wenn mechanische Pulse erkannt werden.
|
||||||
|
-
|
||||||
|
-Bei **Poor** treten zusätzlich wiederholte vollständige Signalausfälle auf: Zwischen den Unterbrechungen liegen **30–180 Sekunden** mit verwertbarem, aber qualitativ schlechtem Signal; jede Unterbrechung dauert **5–20 Sekunden**.
|
||||||
|
-Während eines Ausfalls verschwindet die Plethysmogrammkurve, SpO₂ und PR sind nicht verfügbar und **NO READING** blinkt.
|
||||||
|
-Nach Ende des Ausfalls kehren das Poor-Signal und die numerischen Werte automatisch zurück.
|
||||||
|
-Die Intervalle werden pseudozufällig anhand der Simulationszeit bestimmt und sind unabhängig von der Bildwiederholrate.
|
||||||
|
-Beim erneuten Auswählen von Poor beginnt die Intervallfolge von vorn.
|
||||||
|
-
|
||||||
|
-Ein Signalausfall beeinflusst weder die eingestellte Sauerstoffsättigung noch das EKG, die Erzeugung mechanischer Pulse oder die arterielle Druckkurve.
|
||||||
|
-Die simulierte Pulsfrequenz wird weiterhin aus mechanisch wirksamen QRS-Komplexen abgeleitet.
|
||||||
|
-Das gestörte Plethysmogramm verwendet deterministisches, weich interpoliertes Pseudorauschen, das ausschließlich bereits vorhandene Pulse moduliert.
|
||||||
|
-Es erzeugt daher keine künstlichen Pulse bei PEA, PVT, Kammerflimmern oder Asystolie.
|
||||||
|
-Bei abgezogenem Sensor oder Signalqualität 0 werden auch zuvor gepufferte Plethysmogrammwerte sofort ausgeblendet.
|
||||||
|
-EKG und ART bleiben unbeeinflusst.
|
||||||
|
-Das Kontrollkästchen **Show on monitor** blendet weiterhin den vollständigen SpO₂-Monitorbereich aus; Sensor- und Qualitätszustände lassen den Bereich dagegen sichtbar, damit die Statusmeldungen im Unterricht demonstriert werden können.
|
||||||
|
-
|
||||||
|
-## EKG und mechanische Pulskopplung
|
||||||
|
-
|
||||||
|
-- **EKG-Rhythmen:** Sinusrhythmus, Vorhofflimmern, monomorphe ventrikuläre Tachykardie (VT; potenziell mit mechanischer Perfusion), pulslose ventrikuläre Tachykardie (PVT), Kammerflimmern (VF) und Asystolie.
|
||||||
|
-- **Mechanische Pulsübertragung:** **1:1**, **2:1**, **3:1**, **None (PEA)** oder deterministisch pseudozufällige Übertragung (ca. 65 %).
|
||||||
|
- Die Pulsfrequenz (PR) wird aus mechanisch wirksamen QRS-Ereignissen abgeleitet; ein eigener Pulsfrequenz-Schieberegler existiert nicht.
|
||||||
|
-- Ein mechanisch wirksamer QRS-Komplex löst nach modellhaften **120 ms** einen arteriellen Druckanstieg und nach **300 ms** einen peripheren Plethysmogrammpuls aus.
|
||||||
|
- Das Plethysmogramm wird stark gedämpft und gefiltert dargestellt.
|
||||||
|
-- Bei Auswahl von VT oder PVT wird die Herzfrequenz zunächst auf **160 bpm** gesetzt und sowohl im Schieberegler als auch im numerischen Feld aktualisiert.
|
||||||
|
- Eine anschließende manuelle Änderung ist möglich.
|
||||||
|
-- PVT, VF, Asystolie und PEA unterdrücken mechanische Pulse.
|
||||||
|
- Die ART-Kurve schwankt dann langsam zwischen **0 und 5 mmHg**, statt pulsatile Drücke darzustellen.
|
||||||
|
- Der ART-**SYS**-Wert zeigt den gerundeten niedrigen Transducerdruck (0–5 mmHg).
|
||||||
|
- DIA und MAP zeigen `--`, weil sie nicht zuverlässig bestimmt werden können.
|
||||||
|
- Frühere Druckwerte laufen mit dem Signalverlauf aus dem Sichtfenster.
|
||||||
|
- NIBP folgt einem separaten simulierten Manschettenmesszyklus.
|
||||||
|
-
|
||||||
|
-## Invasiver arterieller Blutdruck und PPV (seit v0.3)
|
||||||
|
-
|
||||||
|
-Die arterielle Druckkurve hat eine feste Skala von **0–200 mmHg** mit Markierungen bei **0, 50, 100, 150 und 200 mmHg**.
|
||||||
|
-Die eingestellten nominellen systolischen und diastolischen ART-Werte sind auf 0–200 mmHg begrenzt.
|
||||||
|
-
|
||||||
|
-Die **Pulsdruckvariation (PPV)** ist im Bereich **0–60 %** in Schritten von 1 % über einen gekoppelten Schieberegler und ein Textfeld einstellbar (Admin → Invasive arterial blood pressure).
|
||||||
|
-Standardwert ist **0 %**, also keine respiratorische Modulation.
|
||||||
|
-Der Atemzyklus wird aus demselben Atemfrequenzparameter wie das Kapnogramm erzeugt.
|
||||||
|
-**RR = 0** deaktiviert die respiratorische Modulation (Apnoe).
|
||||||
|
-
|
||||||
|
-Die synthetische PPV-Definition lautet:
|
||||||
|
-
|
||||||
|
-```text
|
||||||
|
-PPV (%) = 100 × (PPmax − PPmin) / ((PPmax + PPmin) / 2)
|
||||||
|
-```
|
||||||
|
-
|
||||||
|
-Das Modell moduliert den **Pulsdruck** sinusförmig; die Modulation wird für jeden mechanisch wirksamen Herzschlag gesondert bestimmt.
|
||||||
|
-Der diastolische Ausgangsdruck bleibt nominell konstant.
|
||||||
|
-Es entsteht somit vor allem eine **atemabhängige systolische Schwankung von Schlag zu Schlag** und keine beliebige vertikale Verschiebung der gesamten Druckkurve.
|
||||||
|
-Die Modulation beeinflusst weder das EKG noch die mechanische Pulsübertragung oder die Amplitude des Plethysmogramms.
|
||||||
|
-Es handelt sich um ein Anschauungsmodell und nicht um ein validiertes Verfahren zur Vorhersage der Volumenreagibilität.
|
||||||
|
-
|
||||||
|
-**Beispiel:** Ein arterieller Druck von 120/75 mmHg entspricht einem nominellen Pulsdruck von 45 mmHg.
|
||||||
|
-Bei einer PPV von 20 % liegen die idealisierten Pulsdruckextrema bei 40,5 und 49,5 mmHg.
|
||||||
|
-Bei unverändertem diastolischem Druck von 75 mmHg ergeben sich systolische Spitzen von etwa 115,5 bis 124,5 mmHg.
|
||||||
|
-Aufgrund der Kurvenform und der endlichen Anzahl von Herzschlägen innerhalb eines Atemzyklus müssen die tatsächlich dargestellten Maxima die rechnerischen Extremwerte nicht exakt erreichen.
|
||||||
|
-
|
||||||
|
-Der ART-Anzeigebereich zeigt die **nominellen** systolischen und diastolischen Druckwerte sowie den MAP und bei PPV über 0 den **eingestellten** PPV-Wert.
|
||||||
|
-Die PPV wird nicht aus den abgetasteten Druckwerten berechnet.
|
||||||
|
-Bei sehr hohen nominellen systolischen Drücken können modulierte Spitzen die Grenze von 200 mmHg überschreiten.
|
||||||
|
-Die Kurve wird dann **am oberen Skalenende abgeschnitten**, ohne dass die Skala automatisch angepasst wird.
|
||||||
|
-
|
||||||
|
-## Anzeigeoptionen (seit v0.3)
|
||||||
|
-
|
||||||
|
-Die fünf Kontrollkästchen **Show on monitor** beeinflussen ausschließlich die Darstellung:
|
||||||
|
-
|
||||||
|
-| Kontrollkästchen | Ausgeblendete Monitorinhalte |
|
||||||
|
-| --- | --- |
|
||||||
|
-| ECG | EKG-Kurve, Herzfrequenz und ggf. Rhythmusalarm |
|
||||||
|
-| Pulse oximetry | Plethysmogramm, SpO₂ und PR |
|
||||||
|
-| Invasive arterial blood pressure | ART-Kurve, Druckwerte, MAP und PPV-Anzeige |
|
||||||
|
-| Capnography | CO₂-Kurve, EtCO₂ und Atemfrequenz |
|
||||||
|
-| NIBP | Zeitgesteuerte Manschettenmesswerte im roten Wertefeld der rechten Monitorspalte |
|
||||||
|
-
|
||||||
|
-Die verbleibenden Kurven behalten ihre Reihenfolge bei und teilen sich die verfügbare Höhe gleichmäßig.
|
||||||
|
-Auch eine Anzeige ohne sichtbare Kurvenbereiche wird unterstützt.
|
||||||
|
-
|
||||||
|
-## Korrektur der EKG-Morphologie (v0.3.1)
|
||||||
|
-
|
||||||
|
-In der früheren EKG-Simulation wurde die QRS-Breite als fester Anteil des RR-Intervalls definiert und mit 100 Hz abgetastet.
|
||||||
|
-Bei hohen Herzfrequenzen konnten schmale R-Zacken zwischen die Abtastpunkte fallen.
|
||||||
|
-Dadurch schwankte die dargestellte QRS-Amplitude von Schlag zu Schlag stark, obwohl ein regelmäßiger Sinusrhythmus vorlag.
|
||||||
|
-
|
||||||
|
-- Die Breiten der synthetischen P-, QRS- und T-Komponenten werden jetzt in **Millisekunden** und nicht als fixe Anteile des Herzzyklus definiert.
|
||||||
|
- Lage und Breite von P- und T-Wellen passen sich dem RR-Intervall an, während die QRS-Dauer weitgehend konstant bleibt.
|
||||||
|
-- Die Abtastfrequenz wurde auf **250 Hz** (4-ms-Abstände) erhöht, um R-Zacken auch bei **189–240 bpm** zuverlässiger zu erfassen.
|
||||||
|
-- Die EKG-Morphologie ist unabhängig von der respiratorischen PPV-Einstellung.
|
||||||
|
- Die Verzögerungen für arterielle und plethysmographische Pulse sowie die Optionen für die mechanische Pulsübertragung bleiben unverändert.
|
||||||
|
-- Regressionstests vergleichen die R-Zacken-Amplituden bei 60, 75, 120, 189 und 240 bpm und prüfen, dass Änderungen der PPV das EKG-Signal nicht beeinflussen.
|
||||||
|
-
|
||||||
|
-Das EKG bleibt ein schematisches Lehrsignal.
|
||||||
|
-Eine Spannungskalibrierung, ein Modell zur Elektrodenpositionierung, diagnostische Kriterien oder eine patientenspezifische Physiologie werden nicht simuliert.
|
||||||
|
-
|
||||||
|
-## Technische Signalimplementierung
|
||||||
|
-
|
||||||
|
-- Synthetische Signale mit **250 Hz** Abtastfrequenz, **10 Sekunden** gespeichertem Signalverlauf und **8 Sekunden** sichtbarer, fortlaufender Kurve.
|
||||||
|
-- Cairo zeichnet in eine GTK4-`DrawingArea`; die Anzeige skaliert mit der Fenstergröße.
|
||||||
|
-- Jeder mechanisch wirksame QRS-Komplex erhält beim Ereignis einen eigenen respiratorischen PPV-Multiplikator.
|
||||||
|
- Dadurch bleibt die Amplitude des zugehörigen arteriellen Pulsschlags während des gesamten Schlags konsistent.
|
||||||
|
-- Änderungen der PPV beeinflussen weder den peripheren Plethysmogrammpuls noch die Anzahl mechanischer Pulse.
|
||||||
|
-- Klinisch exakte Physiologie, akustische bzw. weitergehende Alarmfunktionen, klinisch validierte NIBP-Algorithmen, Kalibrierung und präzise physiologische Signallaufzeiten sind nicht Bestandteil dieses Prototyps.
|
||||||
|
-
|
||||||
|
-## Projektstruktur
|
||||||
|
-
|
||||||
|
-```text
|
||||||
|
-src/
|
||||||
|
- main.rs Einstiegspunkt der GTK-Anwendung
|
||||||
|
- model.rs Parameter, Rhythmus-/Pulsübertragung, Anzeigeoptionen
|
||||||
|
- simulation.rs QRS-gesteuerte mechanische Signale, PPV und Atemsimulation
|
||||||
|
- render.rs Cairo-Monitordarstellung, dynamische Sichtbarkeit, feste ART-Skala
|
||||||
|
- ui.rs Admin-Bedienelemente und Monitorfenster
|
||||||
|
-```
|
||||||
|
-
|
||||||
|
-## Änderungen seit v0.2.2
|
||||||
|
-
|
||||||
|
-1. Respiratorische PPV mit einstellbarem Bereich von 0–60 %, gekoppelt an den simulierten Atemzyklus und **pro arteriellem Pulsschlag** angewendet.
|
||||||
|
-2. Fünf unabhängige Schalter für die Sichtbarkeit, dynamische Aufteilung der Kurvenbereiche und unabhängiges Ausblenden des NIBP-Bereichs.
|
||||||
|
-3. ART-Skala von **0–250** auf **0–200 mmHg** reduziert und Eingabebereiche angepasst.
|
||||||
|
-4. Regressionstests für die PPV-Berechnung und ihre Auswirkungen auf ART, das Ausblenden des EKG bei weiterhin vorhandenen mechanischen Pulsen, die Auswahl aktiver Monitorbereiche und die Normierung der arteriellen Druckskala ergänzt.
|
||||||
|
-
|
||||||
|
-**Überprüfung:** Das Archiv wurde aus diesen Quelldateien erstellt.
|
||||||
|
-Zur Überprüfung des Rust-/GTK-Builds bitte `cargo test` lokal ausführen.
|
||||||
|
-Rust und die GTK4-Entwicklungskomponenten waren in der Umgebung, in der das ZIP-Archiv erstellt wurde, nicht verfügbar.
|
||||||
|
-
|
||||||
|
-## Änderungen in v0.3.2
|
||||||
|
-
|
||||||
|
-1. Patientenname im Admin-Fenster ergänzt, der unmittelbar als Monitorüberschrift erscheint; bei leerem Feld wird die Standardüberschrift verwendet.
|
||||||
|
-2. Vier Stufen der SpO₂-Signalqualität mit Qualitätssternen und unregelmäßigem, amplitudenreduziertem Plethysmogramm für Poor ergänzt.
|
||||||
|
-3. **Sensor not attached** ergänzt: Anzeige `NO SENSOR` und Unterdrückung von SpO₂, PR und Plethysmogramm.
|
||||||
|
-4. Tests für die Skalierung der Signalqualität, die angezeigten Messwerte und das Verhalten bei nicht angeschlossenem Sensor ergänzt.
|
||||||
|
-
|
||||||
|
-**Build-Überprüfung:** ZIP-Integrität und Patch-Anwendung wurden überprüft.
|
||||||
|
-Die GTK4-Anwendung und die Rust-Tests wurden in der Paketierungsumgebung nicht kompiliert.
|
||||||
|
-Unter Fedora bitte `cargo test` und `cargo run --release` ausführen.
|
||||||
|
-
|
||||||
|
-## v0.4.2 — Rhythmusalarme, Sensoralarme und fehlende Messwerte
|
||||||
|
-
|
||||||
|
-- **VT** kann weiterhin mit mechanischer Perfusion einhergehen.
|
||||||
|
- Der neue Rhythmus **PVT** (pulslose ventrikuläre Tachykardie) zeigt organisierte breite QRS-Komplexe, erzeugt jedoch keine arteriellen oder plethysmographischen Pulse.
|
||||||
|
- Auch Kammerflimmern und Asystolie sind unabhängig von der gewählten Pulsübertragung pulslos.
|
||||||
|
-- **EKG:** Blinkende Meldung **ARRHYTHMIA** bei VT, PVT und VF; blinkende Meldung **ASYSTOLE** bei Asystolie.
|
||||||
|
- Diese Ereignisalarme sind unabhängig von den numerischen Herzfrequenzgrenzen.
|
||||||
|
-- **SpO₂:** Bei abgezogenem Sensor ersetzt die blinkende Meldung **NO SENSOR** die Sauerstoffsättigung.
|
||||||
|
- Signalqualität 0, Ausfall der mechanischen Pulsübertragung oder ein pulsloser Rhythmus führen zur blinkenden Meldung **NO READING** (ohne numerische SpO₂-/PR-Werte).
|
||||||
|
- Ein abgezogener Sensor hat Vorrang.
|
||||||
|
- In diesen Zuständen wird kein Plethysmogramm angezeigt.
|
||||||
|
-- **ART:** Ohne mechanische Pulse (einschließlich PVT, VF, Asystolie und PEA) zeigt die invasive Druckkurve langsame nichtpulsatile Schwankungen zwischen **0 und 5 mmHg**.
|
||||||
|
- In v0.4.2 zeigte die numerische Anzeige `--/--`; seit v0.4.3 wird im SYS-Feld der gerundete gemessene Druck von 0–5 mmHg angezeigt, während DIA und MAP `--` zeigen.
|
||||||
|
-- Die **Bezeichnung des EKG-Rhythmus** wurde aus der Monitoranzeige entfernt.
|
||||||
|
- Sichtbar sind nur Herzfrequenz und gegebenenfalls die zugehörige Alarmmeldung.
|
||||||
|
- Der Rhythmus wird weiterhin im Admin-Fenster ausgewählt.
|
||||||
|
-- Die numerischen Alarmgrenzen und die Adult-Voreinstellung aus v0.4.1 bleiben unverändert.
|
||||||
|
- Sämtliches Verhalten dient ausschließlich der Demonstration und ist nicht für klinische Entscheidungen geeignet.
|
||||||
|
-
|
||||||
|
-## v0.4.3 — Niedriger arterieller Druck, VT-Herzfrequenz und intermittierendes schlechtes SpO₂-Signal
|
||||||
|
-
|
||||||
|
-- Bei pulslosen Rhythmen, PEA oder sonstigem Ausfall mechanischer Pulse zeigt ART SYS den **aktuell gemessenen Druck von 0–5 mmHg** an, zum Beispiel `3/--` und `MAP -- mmHg`.
|
||||||
|
- **Nur SYS** wird gegen die konfigurierten ART-SYS-Grenzen geprüft.
|
||||||
|
- Aus fehlenden MAP- oder DIA-Werten werden keine irreführenden Grenzwertalarme erzeugt.
|
||||||
|
-- Die Auswahl von **VT** oder **PVT** im Admin-Fenster setzt die Herzfrequenz auf **160 bpm** und aktualisiert den zugehörigen Schieberegler und das Textfeld.
|
||||||
|
- Danach kann die Frequenz manuell geändert werden.
|
||||||
|
- VT mit mechanischer Perfusion erzeugt weiterhin QRS-gekoppelte Pulse entsprechend der eingestellten Pulsübertragung; PVT bleibt pulslos.
|
||||||
|
-- Bei **Poor (★)** wechselt das SpO₂-Signal nach pseudozufälligen **30–180 Sekunden** mit nutzbarem, aber qualitativ schlechtem Signal für pseudozufällige **5–20 Sekunden** auf **NO READING**.
|
||||||
|
- Der technische Alarm blinkt, SpO₂ und PR werden ausgeblendet und das Plethysmogramm verschwindet.
|
||||||
|
- Anschließend kehrt das Signal automatisch zur Qualität Poor zurück.
|
||||||
|
- In der simulierten Signalhistorie bleiben sichtbare Lücken für die Ausfälle erhalten.
|
||||||
|
- Wird eine andere Signalqualität gewählt, endet der intermittierende Ausfall unmittelbar.
|
||||||
|
-- Die Adult-Alarmvoreinstellungen, die Reihenfolge der Alarmgrenzen und die arterielle Skala von 0–200 mmHg bleiben unverändert.
|
||||||
|
- Alle Funktionen sind synthetisch und ausschließlich für die Lehre bestimmt.
|
||||||
|
-
|
||||||
|
-## NIBP-Messzyklus (v0.5.0)
|
||||||
|
-
|
||||||
|
-Der nichtinvasive Blutdruck (NIBP) wird **rot** in einem eigenen Wertefeld in
|
||||||
|
-der **rechten Monitorspalte** dargestellt. Der bisherige NIBP-Bereich am
|
||||||
|
-unteren Fensterrand entfällt. Im Admin-Fenster lässt sich ein Messintervall
|
||||||
|
-von **1, 3, 5, 10, 20, 30 oder 60 Minuten** auswählen (Standard: 5 Minuten).
|
||||||
|
-Der erste Messzyklus beginnt beim Simulationsstart. Das Folgeintervall zählt
|
||||||
|
-jeweils **ab dem Ende der vorangegangenen Messung**. Über **Measure now**
|
||||||
|
-kann während einer Messpause sofort eine neue Messung gestartet werden.
|
||||||
|
-Ein **horizontaler Fortschrittsbalken** zeigt den Ablauf des Messintervalls,
|
||||||
|
-ein **vertikaler Balken** den simulierten Manschettendruck von 0–200 mmHg.
|
||||||
|
-
|
||||||
|
-Die Messdauer wird anhand der SpO₂-Signalqualität **zu Messbeginn** bestimmt:
|
||||||
|
-
|
||||||
|
-| Signalqualität | Messdauer | Ergebnis |
|
||||||
|
-| --- | --- | --- |
|
||||||
|
-| Good (★★★) | 20 s | Messwert vorhanden |
|
||||||
|
-| Adequate (★★) | 40 s | Messwert vorhanden |
|
||||||
|
-| Poor (★) | Zufällig 60–120 s | Messwert mit 65 % simulierter Erfolgswahrscheinlichkeit |
|
||||||
|
-| None / Sensor nicht angeschlossen | 120 s | Kein Messwert |
|
||||||
|
-| **No reading** aktiviert | 120 s | Unabhängig von der Qualität kein Messwert |
|
||||||
|
-
|
||||||
|
-Die Manschette wird bis **200 mmHg** aufgepumpt. Bei guter oder adäquater
|
||||||
|
-Signalqualität folgt eine kontinuierliche Entleerung. Bei Poor oder None wird
|
||||||
|
-zunächst bis ungefähr **67 mmHg** entleert, erneut bis ungefähr **133 mmHg**
|
||||||
|
-aufgepumpt und danach vollständig entleert.
|
||||||
|
-Nach Abschluss erscheint der neue Messwert und **blinkt fünfmal durch Ein-
|
||||||
|
-und Ausblenden**, ohne Farbumkehr. Schlägt die Messung fehl, erscheint
|
||||||
|
-`---/---` (MAP `---`). Während einer laufenden Folgemessung bleibt der bisherige
|
||||||
|
-Messwert bis zum Messende sichtbar.
|
||||||
|
-
|
||||||
|
-Die **erste erfolgreiche Messung** übernimmt die im Admin-Fenster eingestellten
|
||||||
|
-NIBP-Ausgangswerte. Alle weiteren Ergebnisse werden aus den aktuellen invasiven
|
||||||
|
-arteriellen SYS-/DIA-Werten mit jeweils unabhängig zufällig gewählten
|
||||||
|
-prozentuellen Abweichungen erzeugt:
|
||||||
|
-
|
||||||
|
-| Signalqualität | Abweichung vom invasiven Blutdruck |
|
||||||
|
-| --- | --- |
|
||||||
|
-| Good | −5 % bis +5 % |
|
||||||
|
-| Adequate | −10 % bis +5 % |
|
||||||
|
-| Poor | −15 % bis −5 %, sofern die Messung gelingt |
|
||||||
|
-| None | Kein Messwert |
|
||||||
|
-
|
||||||
|
-**Cuff on SpO₂ extremity:** Befindet sich die Manschette an der Extremität
|
||||||
|
-mit dem SpO₂-Sensor, ist die effektive Signalqualität bei Manschettendruck
|
||||||
|
-**oberhalb des invasiven systolischen Drucks** None, zwischen systolischem und
|
||||||
|
-diastolischem Druck Poor und **unterhalb des diastolischen Drucks** wieder
|
||||||
|
-auf dem eingestellten Niveau. Eine Verbesserung über die eingestellte
|
||||||
|
-Signalqualität hinaus findet nicht statt.
|
||||||
|
-
|
||||||
|
-**Cuff on ART extremity:** Befindet sich die Manschette an der Extremität mit
|
||||||
|
-dem arteriellen Katheter, wird die invasive Druckkurve oberhalb des invasiven
|
||||||
|
-systolischen Drucks auf dem zuletzt gemessenen Wert eingefroren. Zwischen
|
||||||
|
-systolischem und diastolischem Druck schwankt die Kurve zwischen dem
|
||||||
|
-Manschettendruck und dem NIBP-SYS-Referenzwert. Unterhalb des diastolischen
|
||||||
|
-Drucks erscheint wieder die ursprüngliche arterielle Kurve. Die numerischen
|
||||||
|
-SYS-, DIA- und MAP-Anzeigen folgen der jeweils simulierten Kurve.
|
||||||
|
-Ohne mechanische Pulse bleibt die bisherige 0–5-mmHg-Simulation erhalten.
|
||||||
|
-Beide Manschetten-Interferenzoptionen sind standardmäßig deaktiviert.
|
||||||
|
-
|
||||||
|
-**Die NIBP-Simulation ist ausschließlich ein didaktisches Modell und keine
|
||||||
|
-klinisch validierte oszillometrische Messung.**
|
||||||
|
|
@ -1,4 +1,4 @@
|
||||||
# Patient Monitor Simulation (PaMSim) — v0.4.4
|
# Patient Monitor Simulation (PaMSim) — v0.5.0
|
||||||
|
|
||||||
A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux.
|
A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux.
|
||||||
|
|
||||||
|
|
@ -22,7 +22,7 @@ session (e.g., Fedora KDE/Wayland).
|
||||||
|
|
||||||
**Admin sections** have a narrow colored stripe on their left edge to match the
|
**Admin sections** have a narrow colored stripe on their left edge to match the
|
||||||
monitor: ECG **green**, SpO₂ **yellow**, invasive arterial pressure **red**,
|
monitor: ECG **green**, SpO₂ **yellow**, invasive arterial pressure **red**,
|
||||||
capnography **light grey**, NIBP **light grey**. The Patient section remains
|
capnography **light grey**, NIBP **red**. The Patient section remains
|
||||||
neutral. These accents are drawn by GTK and remain visible independently of
|
neutral. These accents are drawn by GTK and remain visible independently of
|
||||||
light/dark themes. This is a visual-only change; control behavior is unchanged.
|
light/dark themes. This is a visual-only change; control behavior is unchanged.
|
||||||
|
|
||||||
|
|
@ -40,7 +40,7 @@ Waveforms and vital signs disappear together when their respective
|
||||||
visibility checkbox is cleared. Remaining waveform rows expand to use the space.
|
visibility checkbox is cleared. Remaining waveform rows expand to use the space.
|
||||||
Hiding a display channel does **not** stop signal generation or physiological
|
Hiding a display channel does **not** stop signal generation or physiological
|
||||||
coupling: for example, hiding ECG does not stop ART or pleth pulses. NIBP can
|
coupling: for example, hiding ECG does not stop ART or pleth pulses. NIBP can
|
||||||
be hidden independently; this also removes its footer.
|
be hidden independently; this also removes its value box from the right column.
|
||||||
|
|
||||||
The monitor can be resized and toggled fullscreen with **F11**; **Esc** exits
|
The monitor can be resized and toggled fullscreen with **F11**; **Esc** exits
|
||||||
fullscreen. On Wayland, move the monitor to the presentation screen before
|
fullscreen. On Wayland, move the monitor to the presentation screen before
|
||||||
|
|
@ -161,6 +161,68 @@ ART continue unaffected. The **Show on monitor** checkbox still hides the
|
||||||
entire SpO₂ row; sensor/quality controls leave the row visible so the status
|
entire SpO₂ row; sensor/quality controls leave the row visible so the status
|
||||||
can be taught.
|
can be taught.
|
||||||
|
|
||||||
|
## NIBP measurement cycle (v0.5.0)
|
||||||
|
|
||||||
|
NIBP is **red**, with a dedicated value box in the **right-hand numeric column**.
|
||||||
|
The previous static NIBP footer has been removed. In Admin, choose an interval
|
||||||
|
of **1, 3, 5, 10, 20, 30, or 60 minutes** (default 5). The initial cuff cycle
|
||||||
|
begins when the simulation starts; subsequent intervals run **from the end of
|
||||||
|
the last measurement**, not from its beginning. **Measure now** starts an
|
||||||
|
additional cycle if none is in progress. The small **horizontal progress bar**
|
||||||
|
shows the fraction of the waiting interval elapsed; a **vertical 0–200 mmHg
|
||||||
|
gauge** shows the current cuff pressure during measurement.
|
||||||
|
|
||||||
|
The duration and success are determined by the signal quality **at the start
|
||||||
|
of the cycle** (including an absent sensor or an ongoing Poor-signal dropout).
|
||||||
|
Changing quality while a cycle is running does not retroactively change its
|
||||||
|
planned duration:
|
||||||
|
|
||||||
|
| Starting SpO₂ quality | Cycle duration | Result |
|
||||||
|
| --- | --- | --- |
|
||||||
|
| Good (★★★) | 20 s | Measured |
|
||||||
|
| Adequate (★★) | 40 s | Measured |
|
||||||
|
| Poor (★) | Randomly 60–120 s | Simulated 65% chance of a reading |
|
||||||
|
| None / no sensor | 120 s | No reading |
|
||||||
|
| **No reading** checkbox | 120 s | No reading, regardless of quality |
|
||||||
|
|
||||||
|
The cuff inflates to **200 mmHg** then deflates. When the starting signal is
|
||||||
|
Poor or None, it deflates to about **67 mmHg**, reinflates to about **133 mmHg**,
|
||||||
|
and finally deflates to zero. At the end, the completed value becomes visible
|
||||||
|
and **blinks five times by appearing/disappearing** (without the inverted-color
|
||||||
|
alarm effect). If the cycle fails, the displayed reading is `---/---`, with
|
||||||
|
MAP `---`. Previous NIBP values remain visible while the next cuff cycle is
|
||||||
|
in progress, until the new reading is available.
|
||||||
|
|
||||||
|
The **first successful** measurement uses the initial NIBP SYS/DIA values from
|
||||||
|
Admin. Subsequent successful values derive from the current invasive arterial
|
||||||
|
SYS/DIA settings using independently sampled percentage deviations:
|
||||||
|
|
||||||
|
| Starting quality | Deviation relative to IBP |
|
||||||
|
| --- | --- |
|
||||||
|
| Good | −5% to +5% |
|
||||||
|
| Adequate | −10% to +5% |
|
||||||
|
| Poor | −15% to −5%, if a reading succeeds |
|
||||||
|
| None | No reading |
|
||||||
|
|
||||||
|
Optional **Cuff on SpO₂ extremity** changes the *effective* pulse-oximeter
|
||||||
|
quality while the cuff is inflated: above invasive systolic pressure = None;
|
||||||
|
between invasive systolic and diastolic pressure = Poor; below invasive
|
||||||
|
diastolic pressure = the configured quality. The quality never becomes better
|
||||||
|
than the instructor's setting. **NO READING**, missing pleth waveform and
|
||||||
|
restoration of the waveform are handled as before.
|
||||||
|
|
||||||
|
Optional **Cuff on ART extremity** modifies the simulated arterial transducer
|
||||||
|
trace during cuff inflation: above invasive SYS it freezes at the last measured
|
||||||
|
pressure; between invasive SYS and DIA it pulsates between the cuff pressure
|
||||||
|
and the currently available NIBP SYS reference; below invasive DIA it returns
|
||||||
|
to the normal arterial waveform. The ART numerical SYS/DIA/MAP values also
|
||||||
|
reflect this altered trace. With absent mechanical cardiac capture, the
|
||||||
|
previous pulseless 0–5 mmHg simulation is retained and no artificial pulses
|
||||||
|
are introduced. Both cuff-interference options are off by default.
|
||||||
|
|
||||||
|
These cuff and SpO₂ interactions are **deliberately simplified training
|
||||||
|
artifacts**; they should not be interpreted as validated cuff oscillometry.
|
||||||
|
|
||||||
## ECG and mechanical coupling
|
## ECG and mechanical coupling
|
||||||
|
|
||||||
- ECG rhythms: sinus, atrial fibrillation, monomorphic ventricular tachycardia
|
- ECG rhythms: sinus, atrial fibrillation, monomorphic ventricular tachycardia
|
||||||
|
|
@ -177,8 +239,8 @@ can be taught.
|
||||||
drifts smoothly at 0–5 mmHg rather than representing a pulsatile pressure.
|
drifts smoothly at 0–5 mmHg rather than representing a pulsatile pressure.
|
||||||
The ART **SYS** number shows the rounded low transducer pressure (0–5 mmHg),
|
The ART **SYS** number shows the rounded low transducer pressure (0–5 mmHg),
|
||||||
while DIA and MAP show `--` because they cannot be reliably estimated.
|
while DIA and MAP show `--` because they cannot be reliably estimated.
|
||||||
Previous pressure samples scroll out of view. NIBP is a static,
|
Previous pressure samples scroll out of view. NIBP follows a separate,
|
||||||
separately entered cuff reading.
|
time-based simulated cuff-measurement cycle.
|
||||||
|
|
||||||
## Invasive arterial pressure and PPV (new in v0.3)
|
## Invasive arterial pressure and PPV (new in v0.3)
|
||||||
|
|
||||||
|
|
@ -228,7 +290,7 @@ The five **Show on monitor** checkboxes affect the presentation only:
|
||||||
| Pulse oximetry | Pleth waveform, SpO₂ and PR |
|
| Pulse oximetry | Pleth waveform, SpO₂ and PR |
|
||||||
| Invasive arterial blood pressure | ART waveform, pressure values, MAP and PPV label |
|
| Invasive arterial blood pressure | ART waveform, pressure values, MAP and PPV label |
|
||||||
| Capnography | CO₂ waveform, EtCO₂ and RR |
|
| Capnography | CO₂ waveform, EtCO₂ and RR |
|
||||||
| NIBP | Static cuff pressure values and NIBP footer |
|
| NIBP | Timed cuff-measurement values and red right-column value box |
|
||||||
|
|
||||||
Remaining visible waveforms keep their relative order and receive an equal
|
Remaining visible waveforms keep their relative order and receive an equal
|
||||||
share of the available area; zero waveform channels is supported.
|
share of the available area; zero waveform channels is supported.
|
||||||
|
|
@ -263,8 +325,8 @@ are simulated.
|
||||||
The arterial pulse thus retains the same amplitude throughout the beat.
|
The arterial pulse thus retains the same amplitude throughout the beat.
|
||||||
- Varying PPV does not alter the peripheral pleth pulse or the number of
|
- Varying PPV does not alter the peripheral pleth pulse or the number of
|
||||||
mechanical pulses.
|
mechanical pulses.
|
||||||
- Clinical accuracy, dynamic NIBP measurements, alarms, artifacts, calibration,
|
- Clinical accuracy, calibration, artifact realism and patient-specific physiology
|
||||||
precise waveform timing, and patient physiology are outside this prototype.
|
are outside this prototype; its NIBP cycle and alarms are synthetic.
|
||||||
|
|
||||||
## Project layout
|
## Project layout
|
||||||
|
|
||||||
|
|
@ -274,6 +336,7 @@ src/
|
||||||
model.rs Parameters, rhythm/capture settings, display flags
|
model.rs Parameters, rhythm/capture settings, display flags
|
||||||
simulation.rs QRS-timed mechanical signals, PPV and respiratory synthesis
|
simulation.rs QRS-timed mechanical signals, PPV and respiratory synthesis
|
||||||
render.rs Cairo monitor layout, dynamic visibility, fixed ART axis
|
render.rs Cairo monitor layout, dynamic visibility, fixed ART axis
|
||||||
|
nibp.rs Scheduled cuff measurements and measurement results
|
||||||
ui.rs Admin controls and monitor window
|
ui.rs Admin controls and monitor window
|
||||||
```
|
```
|
||||||
|
|
||||||
|
|
@ -282,7 +345,7 @@ src/
|
||||||
1. Respiratory PPV with a 0–60% instructor setting, coupled to the simulated
|
1. Respiratory PPV with a 0–60% instructor setting, coupled to the simulated
|
||||||
respiratory cycle and applied **per arterial beat**.
|
respiratory cycle and applied **per arterial beat**.
|
||||||
2. Five independent display visibility toggles, dynamic waveform row layout,
|
2. Five independent display visibility toggles, dynamic waveform row layout,
|
||||||
and independent NIBP-footer hiding.
|
and independent NIBP value-box hiding.
|
||||||
3. ART axis reduced from **0–250** to **0–200 mmHg**, with inputs adjusted to
|
3. ART axis reduced from **0–250** to **0–200 mmHg**, with inputs adjusted to
|
||||||
the new range.
|
the new range.
|
||||||
4. Added regression tests for PPV arithmetic and its effects on ART, for
|
4. Added regression tests for PPV arithmetic and its effects on ART, for
|
||||||
|
|
|
||||||
|
|
@ -1,4 +1,5 @@
|
||||||
mod model;
|
mod model;
|
||||||
|
mod nibp;
|
||||||
mod render;
|
mod render;
|
||||||
mod simulation;
|
mod simulation;
|
||||||
mod ui;
|
mod ui;
|
||||||
|
|
|
||||||
|
|
@ -94,6 +94,10 @@ pub enum Spo2Quality {
|
||||||
}
|
}
|
||||||
|
|
||||||
impl Spo2Quality {
|
impl Spo2Quality {
|
||||||
|
pub fn min(self, other: Self) -> Self {
|
||||||
|
if (self as u8) <= (other as u8) { self } else { other }
|
||||||
|
}
|
||||||
|
|
||||||
pub fn stars(self) -> &'static str {
|
pub fn stars(self) -> &'static str {
|
||||||
match self {
|
match self {
|
||||||
Self::None => "",
|
Self::None => "",
|
||||||
|
|
@ -207,8 +211,12 @@ pub struct Parameters {
|
||||||
pub art_diastolic: i32, // mmHg
|
pub art_diastolic: i32, // mmHg
|
||||||
pub arterial_shape: ArterialShape,
|
pub arterial_shape: ArterialShape,
|
||||||
pub pulse_pressure_variation: i32, // PPV %, 0 disables respiratory variation
|
pub pulse_pressure_variation: i32, // PPV %, 0 disables respiratory variation
|
||||||
pub nibp_systolic: i32, // mmHg, historical/static simulated cuff value
|
pub nibp_systolic: i32, // mmHg, initial measured NIBP result
|
||||||
pub nibp_diastolic: i32, // mmHg
|
pub nibp_diastolic: i32, // mmHg, initial measured NIBP result
|
||||||
|
pub nibp_interval_minutes: i32, // 1 / 3 / 5 / 10 / 20 / 30 / 60
|
||||||
|
pub nibp_no_reading: bool, // force unsuccessful cuff measurement
|
||||||
|
pub nibp_cuff_on_spo2: bool, // simulated probe on cuff extremity
|
||||||
|
pub nibp_cuff_on_art: bool, // simulated arterial catheter on cuff extremity
|
||||||
pub etco2: i32, // mmHg
|
pub etco2: i32, // mmHg
|
||||||
pub respiratory_rate: i32, // breaths/min
|
pub respiratory_rate: i32, // breaths/min
|
||||||
pub capno_shape: CapnoShape,
|
pub capno_shape: CapnoShape,
|
||||||
|
|
@ -237,13 +245,14 @@ impl Parameters {
|
||||||
self.spo2_status_during(pulse_rate, false)
|
self.spo2_status_during(pulse_rate, false)
|
||||||
}
|
}
|
||||||
|
|
||||||
/// Poor-quality signal interruptions are generated by the simulator and
|
/// Effective quality can be temporarily reduced by an NIBP cuff on the
|
||||||
/// override the normal reading, but not a physically disconnected sensor.
|
/// same extremity. A detached probe still has highest priority.
|
||||||
pub fn spo2_status_during(&self, pulse_rate: Option<i32>, signal_lost: bool) -> Spo2Status {
|
pub fn spo2_status_at_quality(&self, pulse_rate: Option<i32>, signal_lost: bool,
|
||||||
|
effective_quality: Spo2Quality) -> Spo2Status {
|
||||||
if !self.spo2_sensor_attached {
|
if !self.spo2_sensor_attached {
|
||||||
Spo2Status::NoSensor
|
Spo2Status::NoSensor
|
||||||
} else if (signal_lost && self.spo2_quality == Spo2Quality::Poor)
|
} else if (signal_lost && self.spo2_quality == Spo2Quality::Poor)
|
||||||
|| self.spo2_quality == Spo2Quality::None || pulse_rate.is_none()
|
|| effective_quality == Spo2Quality::None || pulse_rate.is_none()
|
||||||
|| !self.ecg_rhythm.can_generate_pulse()
|
|| !self.ecg_rhythm.can_generate_pulse()
|
||||||
|| self.pulse_conduction == PulseConduction::None
|
|| self.pulse_conduction == PulseConduction::None
|
||||||
|| self.heart_rate <= 0
|
|| self.heart_rate <= 0
|
||||||
|
|
@ -253,6 +262,12 @@ impl Parameters {
|
||||||
Spo2Status::Available
|
Spo2Status::Available
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
/// Quality without cuff interference; retained for regression tests.
|
||||||
|
#[cfg(test)]
|
||||||
|
pub fn spo2_status_during(&self, pulse_rate: Option<i32>, signal_lost: bool) -> Spo2Status {
|
||||||
|
self.spo2_status_at_quality(pulse_rate, signal_lost, self.spo2_quality)
|
||||||
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
impl Default for Parameters {
|
impl Default for Parameters {
|
||||||
|
|
@ -272,6 +287,10 @@ impl Default for Parameters {
|
||||||
pulse_pressure_variation: 0,
|
pulse_pressure_variation: 0,
|
||||||
nibp_systolic: 118,
|
nibp_systolic: 118,
|
||||||
nibp_diastolic: 74,
|
nibp_diastolic: 74,
|
||||||
|
nibp_interval_minutes: 5,
|
||||||
|
nibp_no_reading: false,
|
||||||
|
nibp_cuff_on_spo2: false,
|
||||||
|
nibp_cuff_on_art: false,
|
||||||
etco2: 38,
|
etco2: 38,
|
||||||
respiratory_rate: 14,
|
respiratory_rate: 14,
|
||||||
capno_shape: CapnoShape::Normal,
|
capno_shape: CapnoShape::Normal,
|
||||||
|
|
|
||||||
308
patient-monitor-simulation/src/nibp.rs
Normal file
308
patient-monitor-simulation/src/nibp.rs
Normal file
|
|
@ -0,0 +1,308 @@
|
||||||
|
//! Synthetic oscillometric NIBP cuff cycle; no physiological or diagnostic validity.
|
||||||
|
//! All time is measured in simulation seconds so the behavior is independent of FPS.
|
||||||
|
|
||||||
|
use crate::model::{Parameters, Spo2Quality};
|
||||||
|
|
||||||
|
#[derive(Clone, Copy, Debug, PartialEq, Eq)]
|
||||||
|
pub struct NibpReading {
|
||||||
|
pub systolic: i32,
|
||||||
|
pub diastolic: i32,
|
||||||
|
}
|
||||||
|
|
||||||
|
impl NibpReading {
|
||||||
|
pub fn mean(self) -> i32 {
|
||||||
|
crate::model::mean_arterial_pressure(self.systolic, self.diastolic)
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
#[derive(Clone, Copy, Debug, PartialEq, Eq)]
|
||||||
|
pub enum CuffZone {
|
||||||
|
Free,
|
||||||
|
Partial,
|
||||||
|
Occluded,
|
||||||
|
}
|
||||||
|
|
||||||
|
#[derive(Clone, Copy, Debug)]
|
||||||
|
struct Cycle {
|
||||||
|
start: f64,
|
||||||
|
duration: f64,
|
||||||
|
quality_at_start: Spo2Quality,
|
||||||
|
first: bool,
|
||||||
|
first_reading: NibpReading,
|
||||||
|
}
|
||||||
|
|
||||||
|
#[derive(Debug)]
|
||||||
|
pub struct NibpMachine {
|
||||||
|
cycle: Option<Cycle>,
|
||||||
|
ever_started: bool,
|
||||||
|
ever_successful: bool,
|
||||||
|
last_completed: Option<f64>,
|
||||||
|
last_reading: Option<NibpReading>,
|
||||||
|
last_success_at: Option<f64>,
|
||||||
|
rng: u64,
|
||||||
|
}
|
||||||
|
|
||||||
|
impl NibpMachine {
|
||||||
|
pub fn new() -> Self {
|
||||||
|
Self {
|
||||||
|
cycle: None,
|
||||||
|
ever_started: false,
|
||||||
|
ever_successful: false,
|
||||||
|
last_completed: None,
|
||||||
|
last_reading: None,
|
||||||
|
last_success_at: None,
|
||||||
|
rng: 0xC4E3_1A86_957B_1D29,
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
fn random_unit(&mut self) -> f64 {
|
||||||
|
self.rng = self.rng.wrapping_mul(6_364_136_223_846_793_005)
|
||||||
|
.wrapping_add(1_442_695_040_888_963_407);
|
||||||
|
(self.rng >> 11) as f64 / (1_u64 << 53) as f64
|
||||||
|
}
|
||||||
|
|
||||||
|
fn random_between(&mut self, low: f64, high: f64) -> f64 {
|
||||||
|
low + self.random_unit() * (high - low)
|
||||||
|
}
|
||||||
|
|
||||||
|
pub fn measuring(&self) -> bool {
|
||||||
|
self.cycle.is_some()
|
||||||
|
}
|
||||||
|
|
||||||
|
pub fn reading(&self) -> Option<NibpReading> {
|
||||||
|
self.last_reading
|
||||||
|
}
|
||||||
|
|
||||||
|
/// Time since the last completed measurement as a fraction of the interval.
|
||||||
|
/// While measuring, the waiting progress resets to zero.
|
||||||
|
pub fn interval_progress(&self, now: f64, minutes: i32) -> f64 {
|
||||||
|
if self.cycle.is_some() { return 0.0; }
|
||||||
|
let Some(last) = self.last_completed else { return 0.0; };
|
||||||
|
((now - last) / (f64::from(minutes.max(1)) * 60.0)).clamp(0.0, 1.0)
|
||||||
|
}
|
||||||
|
|
||||||
|
/// Five appearances/disappearances over five seconds (no color inversion).
|
||||||
|
pub fn show_new_value(&self, now: f64) -> bool {
|
||||||
|
let Some(last) = self.last_success_at else { return true; };
|
||||||
|
let elapsed = now - last;
|
||||||
|
!(0.0..5.0).contains(&elapsed) || (elapsed * 2.0).floor() as i32 % 2 == 0
|
||||||
|
}
|
||||||
|
|
||||||
|
pub fn cuff_pressure(&self, now: f64) -> f64 {
|
||||||
|
let Some(cycle) = self.cycle else { return 0.0; };
|
||||||
|
let t = ((now - cycle.start) / cycle.duration).clamp(0.0, 1.0);
|
||||||
|
let poor = matches!(cycle.quality_at_start, Spo2Quality::Poor | Spo2Quality::None);
|
||||||
|
(if !poor {
|
||||||
|
if t < 0.13 { 200.0 * t / 0.13 }
|
||||||
|
else { 200.0 * (1.0 - t) / 0.87 }
|
||||||
|
} else if t < 0.13 {
|
||||||
|
200.0 * t / 0.13
|
||||||
|
} else if t < 0.54 {
|
||||||
|
// First deflation stops at one third of the maximum pressure.
|
||||||
|
200.0 - (200.0 - 200.0 / 3.0) * (t - 0.13) / 0.41
|
||||||
|
} else if t < 0.71 {
|
||||||
|
// Reinflation to two thirds of maximum pressure.
|
||||||
|
200.0 / 3.0 + (200.0 / 3.0) * (t - 0.54) / 0.17
|
||||||
|
} else {
|
||||||
|
(400.0 / 3.0) * (1.0 - t) / 0.29
|
||||||
|
}).clamp(0.0, 200.0)
|
||||||
|
}
|
||||||
|
|
||||||
|
pub fn cuff_zone(&self, now: f64, params: &Parameters) -> CuffZone {
|
||||||
|
if !self.measuring() { return CuffZone::Free; }
|
||||||
|
let pressure = self.cuff_pressure(now);
|
||||||
|
if pressure > f64::from(params.art_systolic) { CuffZone::Occluded }
|
||||||
|
else if pressure > f64::from(params.art_diastolic) { CuffZone::Partial }
|
||||||
|
else { CuffZone::Free }
|
||||||
|
}
|
||||||
|
|
||||||
|
pub fn effective_spo2_quality(&self, now: f64, p: &Parameters) -> Spo2Quality {
|
||||||
|
if !p.nibp_cuff_on_spo2 { return p.spo2_quality; }
|
||||||
|
match self.cuff_zone(now, p) {
|
||||||
|
CuffZone::Occluded => Spo2Quality::None,
|
||||||
|
CuffZone::Partial => p.spo2_quality.min(Spo2Quality::Poor),
|
||||||
|
CuffZone::Free => p.spo2_quality,
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
fn start(&mut self, now: f64, p: &Parameters, quality: Spo2Quality) {
|
||||||
|
let quality = if p.nibp_no_reading { Spo2Quality::None } else { quality };
|
||||||
|
let duration = match quality {
|
||||||
|
Spo2Quality::Good => 20.0,
|
||||||
|
Spo2Quality::Adequate => 40.0,
|
||||||
|
Spo2Quality::Poor => self.random_between(60.0, 120.0),
|
||||||
|
Spo2Quality::None => 120.0,
|
||||||
|
};
|
||||||
|
self.cycle = Some(Cycle {
|
||||||
|
start: now,
|
||||||
|
duration,
|
||||||
|
quality_at_start: quality,
|
||||||
|
first: !self.ever_successful,
|
||||||
|
first_reading: NibpReading {
|
||||||
|
systolic: p.nibp_systolic,
|
||||||
|
diastolic: p.nibp_diastolic,
|
||||||
|
},
|
||||||
|
});
|
||||||
|
self.ever_started = true;
|
||||||
|
}
|
||||||
|
|
||||||
|
/// The initial cycle starts at simulation time zero. Afterwards, the
|
||||||
|
/// interval is counted from the last completed measurement, not cycle start.
|
||||||
|
pub fn update(&mut self, now: f64, p: &Parameters, quality_at_start: Spo2Quality) {
|
||||||
|
if now < 0.0 { return; }
|
||||||
|
if let Some(cycle) = self.cycle {
|
||||||
|
if now - cycle.start >= cycle.duration {
|
||||||
|
self.complete(now, p, cycle);
|
||||||
|
}
|
||||||
|
} else if !self.ever_started || self.last_completed.is_some_and(|last| {
|
||||||
|
now - last >= f64::from(p.nibp_interval_minutes.max(1)) * 60.0
|
||||||
|
}) {
|
||||||
|
self.start(now, p, quality_at_start);
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
/// Instructor-triggered measurement; ignored if a cuff cycle is in progress.
|
||||||
|
pub fn measure_now(&mut self, now: f64, p: &Parameters, quality: Spo2Quality) {
|
||||||
|
if !self.measuring() { self.start(now.max(0.0), p, quality); }
|
||||||
|
}
|
||||||
|
|
||||||
|
fn complete(&mut self, now: f64, p: &Parameters, cycle: Cycle) {
|
||||||
|
let successful = match cycle.quality_at_start {
|
||||||
|
Spo2Quality::None => false,
|
||||||
|
Spo2Quality::Poor => self.random_unit() < 0.65,
|
||||||
|
Spo2Quality::Adequate | Spo2Quality::Good => true,
|
||||||
|
};
|
||||||
|
self.last_reading = if successful {
|
||||||
|
let reading = if cycle.first {
|
||||||
|
cycle.first_reading
|
||||||
|
} else {
|
||||||
|
let (low, high) = match cycle.quality_at_start {
|
||||||
|
Spo2Quality::Good => (-0.05, 0.05),
|
||||||
|
Spo2Quality::Adequate => (-0.10, 0.05),
|
||||||
|
Spo2Quality::Poor => (-0.15, -0.05),
|
||||||
|
Spo2Quality::None => (0.0, 0.0),
|
||||||
|
};
|
||||||
|
// Independent random deviation for SYS and DIA; preserve SYS >= DIA.
|
||||||
|
let sys = (f64::from(p.art_systolic) * (1.0 + self.random_between(low, high)))
|
||||||
|
.round().clamp(0.0, 260.0) as i32;
|
||||||
|
let dia = (f64::from(p.art_diastolic) * (1.0 + self.random_between(low, high)))
|
||||||
|
.round().clamp(0.0, f64::from(sys)) as i32;
|
||||||
|
NibpReading { systolic: sys, diastolic: dia }
|
||||||
|
};
|
||||||
|
self.last_success_at = Some(now);
|
||||||
|
self.ever_successful = true;
|
||||||
|
Some(reading)
|
||||||
|
} else {
|
||||||
|
self.last_success_at = None;
|
||||||
|
None
|
||||||
|
};
|
||||||
|
self.cycle = None;
|
||||||
|
self.last_completed = Some(now);
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
#[cfg(test)]
|
||||||
|
mod tests {
|
||||||
|
use super::*;
|
||||||
|
|
||||||
|
#[test]
|
||||||
|
fn intervals_and_first_values() {
|
||||||
|
let mut m = NibpMachine::new();
|
||||||
|
let p = Parameters::default();
|
||||||
|
m.update(0.0, &p, Spo2Quality::Good);
|
||||||
|
assert!(m.measuring());
|
||||||
|
assert_eq!(m.reading(), None);
|
||||||
|
assert!((m.cuff_pressure(2.6) - 200.0).abs() < 0.1);
|
||||||
|
m.update(20.0, &p, Spo2Quality::Good);
|
||||||
|
assert_eq!(m.reading(), Some(NibpReading { systolic: 118, diastolic: 74 }));
|
||||||
|
assert!(!m.measuring());
|
||||||
|
assert!(m.show_new_value(20.1));
|
||||||
|
assert!(!m.show_new_value(20.6));
|
||||||
|
assert!(m.show_new_value(25.1));
|
||||||
|
assert!((m.interval_progress(170.0, 5) - 0.5).abs() < 1e-6);
|
||||||
|
m.update(319.9, &p, Spo2Quality::Good);
|
||||||
|
assert!(!m.measuring());
|
||||||
|
m.update(320.0, &p, Spo2Quality::Good);
|
||||||
|
assert!(m.measuring());
|
||||||
|
m.update(340.0, &p, Spo2Quality::Good);
|
||||||
|
assert!(m.reading().is_some());
|
||||||
|
let result = m.reading().unwrap();
|
||||||
|
assert!((result.systolic - p.art_systolic).abs() <= 6);
|
||||||
|
assert!((result.diastolic - p.art_diastolic).abs() <= 4);
|
||||||
|
}
|
||||||
|
|
||||||
|
#[test]
|
||||||
|
fn failed_measurement_and_retry_cycle() {
|
||||||
|
let p = Parameters { nibp_no_reading: true, ..Parameters::default() };
|
||||||
|
let mut m = NibpMachine::new();
|
||||||
|
m.update(0.0, &p, Spo2Quality::Good);
|
||||||
|
assert!(m.measuring());
|
||||||
|
assert!((m.cuff_pressure(15.6) - 200.0).abs() < 0.1);
|
||||||
|
assert!((m.cuff_pressure(64.8) - 200.0/3.0).abs() < 0.1);
|
||||||
|
assert!((m.cuff_pressure(85.2) - 400.0/3.0).abs() < 0.1);
|
||||||
|
m.update(120.0, &p, Spo2Quality::Good);
|
||||||
|
assert!(m.reading().is_none());
|
||||||
|
}
|
||||||
|
|
||||||
|
#[test]
|
||||||
|
fn cuff_interference_never_improves_quality() {
|
||||||
|
let p = Parameters { nibp_cuff_on_spo2: true, ..Parameters::default() };
|
||||||
|
let mut m = NibpMachine::new();
|
||||||
|
m.update(0.0, &p, Spo2Quality::Good);
|
||||||
|
assert_eq!(m.effective_spo2_quality(2.6, &p), Spo2Quality::None);
|
||||||
|
assert_eq!(m.effective_spo2_quality(10.0, &p), Spo2Quality::Poor);
|
||||||
|
assert_eq!(m.effective_spo2_quality(19.0, &p), Spo2Quality::Good);
|
||||||
|
let p = Parameters { spo2_quality: Spo2Quality::Poor, ..p };
|
||||||
|
assert_eq!(m.effective_spo2_quality(10.0, &p), Spo2Quality::Poor);
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
#[cfg(test)]
|
||||||
|
mod more_tests {
|
||||||
|
use super::*;
|
||||||
|
|
||||||
|
#[test]
|
||||||
|
fn quality_determines_cycle_duration() {
|
||||||
|
for (quality, seconds) in [
|
||||||
|
(Spo2Quality::Good, 20.0),
|
||||||
|
(Spo2Quality::Adequate, 40.0),
|
||||||
|
(Spo2Quality::None, 120.0),
|
||||||
|
] {
|
||||||
|
let mut machine = NibpMachine::new();
|
||||||
|
let p = Parameters::default();
|
||||||
|
machine.update(0.0, &p, quality);
|
||||||
|
machine.update(seconds - 0.01, &p, quality);
|
||||||
|
assert!(machine.measuring());
|
||||||
|
machine.update(seconds, &p, quality);
|
||||||
|
assert!(!machine.measuring());
|
||||||
|
assert_eq!(machine.reading().is_some(), quality != Spo2Quality::None);
|
||||||
|
}
|
||||||
|
let mut machine = NibpMachine::new();
|
||||||
|
let p = Parameters::default();
|
||||||
|
machine.update(0.0, &p, Spo2Quality::Poor);
|
||||||
|
assert!((60.0..=120.0).contains(&machine.cycle.unwrap().duration));
|
||||||
|
}
|
||||||
|
|
||||||
|
#[test]
|
||||||
|
fn first_successful_reading_uses_admin_even_after_failed_cycle() {
|
||||||
|
let mut p = Parameters { nibp_no_reading: true, ..Parameters::default() };
|
||||||
|
let mut machine = NibpMachine::new();
|
||||||
|
machine.update(0.0, &p, Spo2Quality::None);
|
||||||
|
machine.update(120.0, &p, Spo2Quality::None);
|
||||||
|
assert!(machine.reading().is_none());
|
||||||
|
p.nibp_no_reading = false;
|
||||||
|
machine.measure_now(121.0, &p, Spo2Quality::Good);
|
||||||
|
machine.update(141.0, &p, Spo2Quality::Good);
|
||||||
|
assert_eq!(machine.reading(), Some(NibpReading { systolic: 118, diastolic: 74 }));
|
||||||
|
}
|
||||||
|
|
||||||
|
#[test]
|
||||||
|
fn partial_pressure_uses_diastic_and_systolic_boundaries() {
|
||||||
|
let p = Parameters { nibp_cuff_on_art: true, ..Parameters::default() };
|
||||||
|
let mut machine = NibpMachine::new();
|
||||||
|
machine.update(0.0, &p, Spo2Quality::Good);
|
||||||
|
assert_eq!(machine.cuff_zone(2.6, &p), CuffZone::Occluded);
|
||||||
|
assert_eq!(machine.cuff_zone(10.0, &p), CuffZone::Partial);
|
||||||
|
assert_eq!(machine.cuff_zone(19.0, &p), CuffZone::Free);
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
@ -1,7 +1,7 @@
|
||||||
//! Size-independent Cairo drawing of the synthetic bedside monitor.
|
//! Size-independent Cairo drawing of the synthetic bedside monitor.
|
||||||
use gtk::cairo::{Context, FontSlant, FontWeight, LineCap, LineJoin};
|
use gtk::cairo::{Context, FontSlant, FontWeight, LineCap, LineJoin};
|
||||||
|
|
||||||
use crate::model::{mean_arterial_pressure, AlarmLimits, AlarmState, Parameters, PulseConduction, Spo2Quality, Spo2Status};
|
use crate::model::{AlarmLimits, AlarmState, Parameters, PulseConduction, Spo2Quality, Spo2Status};
|
||||||
use crate::simulation::{Sample, Simulator};
|
use crate::simulation::{Sample, Simulator};
|
||||||
|
|
||||||
type Color = (f64, f64, f64);
|
type Color = (f64, f64, f64);
|
||||||
|
|
@ -33,10 +33,14 @@ pub fn draw(cr: &Context, width: i32, height: i32, p: &Parameters, sim: &Simulat
|
||||||
|
|
||||||
let pad = (w.min(h) * 0.018).clamp(6.0, 20.0);
|
let pad = (w.min(h) * 0.018).clamp(6.0, 20.0);
|
||||||
let header = (h * 0.083).clamp(32.0, 68.0);
|
let header = (h * 0.083).clamp(32.0, 68.0);
|
||||||
let footer = if p.show_nibp { (h * 0.13).clamp(52.0, 102.0) } else { 0.0 };
|
|
||||||
let channels = visible_channels(p);
|
let channels = visible_channels(p);
|
||||||
let row_height = ((h - header - footer - pad).max(20.0))
|
let body_height = (h - header - pad).max(20.0);
|
||||||
/ (channels.len().max(1) as f64);
|
// NIBP occupies a dedicated box at the bottom of the numerical right column.
|
||||||
|
// Trace rows remain full height on the left.
|
||||||
|
let nibp_box_height = if p.show_nibp { (h * 0.24).clamp(135.0, 210.0).min(body_height * 0.55) }
|
||||||
|
else { 0.0 };
|
||||||
|
let trace_row_height = body_height / channels.len().max(1) as f64;
|
||||||
|
let vital_row_height = (body_height - nibp_box_height) / channels.len().max(1) as f64;
|
||||||
let sidebar = (w * 0.235).clamp(125.0, 370.0).min(w * 0.44);
|
let sidebar = (w * 0.235).clamp(125.0, 370.0).min(w * 0.44);
|
||||||
let split_x = w - sidebar - pad;
|
let split_x = w - sidebar - pad;
|
||||||
let trace_left = pad + 6.0;
|
let trace_left = pad + 6.0;
|
||||||
|
|
@ -60,60 +64,112 @@ pub fn draw(cr: &Context, width: i32, height: i32, p: &Parameters, sim: &Simulat
|
||||||
11.0 * text_scale, MUTED, false);
|
11.0 * text_scale, MUTED, false);
|
||||||
}
|
}
|
||||||
stroke_line(cr, pad, header, w - pad, header, MUTED, 0.8);
|
stroke_line(cr, pad, header, w - pad, header, MUTED, 0.8);
|
||||||
stroke_line(cr, split_x, header, split_x, h - footer, MUTED, 0.9);
|
stroke_line(cr, split_x, header, split_x, h - pad, MUTED, 0.9);
|
||||||
|
|
||||||
for (index, (channel, title, color)) in channels.iter().copied().enumerate() {
|
for (index, (channel, title, color)) in channels.iter().copied().enumerate() {
|
||||||
let top = header + index as f64 * row_height;
|
let top = header + index as f64 * trace_row_height;
|
||||||
let bottom = top + row_height;
|
let bottom = top + trace_row_height;
|
||||||
stroke_line(cr, pad, bottom, w - pad, bottom, MUTED, 0.65);
|
stroke_line(cr, pad, bottom, split_x, bottom, MUTED, 0.65);
|
||||||
text(cr, title, trace_left + 4.0, top + row_height * 0.17,
|
text(cr, title, trace_left + 4.0, top + trace_row_height * 0.17,
|
||||||
(row_height * 0.11).clamp(10.0, 17.0), color, false);
|
(trace_row_height * 0.11).clamp(10.0, 17.0), color, false);
|
||||||
draw_trace(cr, channel, color, trace_left, trace_right,
|
draw_trace(cr, channel, color, trace_left, trace_right,
|
||||||
top + row_height * 0.25, bottom - row_height * 0.06, p, sim);
|
top + trace_row_height * 0.25, bottom - trace_row_height * 0.06, p, sim);
|
||||||
|
let vital_top = header + index as f64 * vital_row_height;
|
||||||
|
stroke_line(cr, split_x, vital_top + vital_row_height,
|
||||||
|
w - pad, vital_top + vital_row_height, MUTED, 0.65);
|
||||||
draw_vitals(cr, channel, color, split_x + pad,
|
draw_vitals(cr, channel, color, split_x + pad,
|
||||||
top, row_height, sidebar - 2.0 * pad, p, sim);
|
vital_top, vital_row_height, sidebar - 2.0 * pad, p, sim);
|
||||||
}
|
}
|
||||||
|
|
||||||
if p.show_nibp {
|
if p.show_nibp {
|
||||||
let footer_top = h - footer;
|
draw_nibp_box(cr, split_x + pad, h - pad - nibp_box_height,
|
||||||
let flash = alarm_flash_on(sim);
|
sidebar - 2.0 * pad, nibp_box_height, p, sim);
|
||||||
let mean = mean_arterial_pressure(p.nibp_systolic, p.nibp_diastolic);
|
|
||||||
text(cr, "NIBP", pad + 6.0, footer_top + footer * 0.32,
|
|
||||||
(footer * 0.21).clamp(12.0, 20.0), LIGHT_GREY, false);
|
|
||||||
draw_pressure_value(cr, p.nibp_systolic, p.nibp_diastolic,
|
|
||||||
pad + 6.0, footer_top + footer * 0.77,
|
|
||||||
(footer * 0.42).clamp(20.0, 44.0),
|
|
||||||
(w * 0.28).min(255.0).max(70.0), LIGHT_GREY,
|
|
||||||
alarmed(p.alarms.nibp_sys, Some(p.nibp_systolic)),
|
|
||||||
alarmed(p.alarms.nibp_dia, Some(p.nibp_diastolic)), flash);
|
|
||||||
if w >= 510.0 {
|
|
||||||
draw_alarm_inline(cr, pad + (w * 0.28).min(260.0),
|
|
||||||
footer_top + footer * 0.73, (footer * 0.24).clamp(12.0, 23.0),
|
|
||||||
(w * 0.25).max(90.0), LIGHT_GREY,
|
|
||||||
"MAP ", &mean.to_string(), " mmHg",
|
|
||||||
alarmed(p.alarms.nibp_map, Some(mean)), flash);
|
|
||||||
}
|
|
||||||
draw_alarm_annotations(cr, &[
|
|
||||||
("SYS", p.alarms.nibp_sys),
|
|
||||||
("MAP", p.alarms.nibp_map),
|
|
||||||
("DIA", p.alarms.nibp_dia),
|
|
||||||
], w - pad - 8.0, footer_top, footer, (w * 0.24).max(115.0));
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
fn draw_nibp_box(cr: &Context, x: f64, top: f64, width: f64, height: f64,
|
||||||
|
p: &Parameters, sim: &Simulator) {
|
||||||
|
let right = x + width;
|
||||||
|
let pressure = sim.nibp().cuff_pressure(sim.time());
|
||||||
|
let in_progress = sim.nibp().measuring();
|
||||||
|
let reading = sim.nibp().reading();
|
||||||
|
let value_width = (width - 35.0).max(30.0);
|
||||||
|
let small = (height * 0.095).clamp(10.0, 14.0);
|
||||||
|
let number_size = (height * 0.25).clamp(18.0, 41.0);
|
||||||
|
// Subtle red outline distinguishes the independent cuff reading box.
|
||||||
|
let _ = cr.save();
|
||||||
|
cr.set_source_rgb(0.28, 0.09, 0.10);
|
||||||
|
cr.set_line_width(1.0);
|
||||||
|
cr.rectangle(x - 7.0, top, width + 13.0, height - 1.0);
|
||||||
|
let _ = cr.stroke();
|
||||||
|
let _ = cr.restore();
|
||||||
|
text(cr, "NIBP", x, top + height * 0.13, small * 1.15, RED, true);
|
||||||
|
if in_progress {
|
||||||
|
text(cr, "MEASURING", x, top + height * 0.27, small, RED, false);
|
||||||
|
} else {
|
||||||
|
text(cr, "mmHg", x, top + height * 0.27, small, MUTED, false);
|
||||||
|
}
|
||||||
|
|
||||||
|
if sim.nibp().show_new_value(sim.time()) {
|
||||||
|
let (sys, dia) = reading.map_or(("---".to_owned(), "---".to_owned()), |r|
|
||||||
|
(r.systolic.to_string(), r.diastolic.to_string()));
|
||||||
|
draw_pressure_components(cr, &sys, &dia, x, top + height * 0.60,
|
||||||
|
number_size, value_width, RED,
|
||||||
|
alarmed(p.alarms.nibp_sys, reading.map(|r| r.systolic)),
|
||||||
|
alarmed(p.alarms.nibp_dia, reading.map(|r| r.diastolic)), alarm_flash_on(sim));
|
||||||
|
let map = reading.map_or("---".to_owned(), |r| r.mean().to_string());
|
||||||
|
draw_alarm_inline(cr, x, top + height * 0.72, small * 1.15, value_width,
|
||||||
|
RED, "MAP ", &map, " mmHg",
|
||||||
|
alarmed(p.alarms.nibp_map, reading.map(|r| r.mean())), alarm_flash_on(sim));
|
||||||
|
}
|
||||||
|
|
||||||
|
// Horizontal: elapsed fraction of the selected measurement interval.
|
||||||
|
let progress_y = top + height * 0.85;
|
||||||
|
let progress_width = (width - 9.0).max(8.0);
|
||||||
|
stroke_line(cr, x, progress_y, x + progress_width, progress_y, MUTED, 4.0);
|
||||||
|
stroke_line(cr, x, progress_y,
|
||||||
|
x + progress_width * sim.nibp().interval_progress(sim.time(), p.nibp_interval_minutes),
|
||||||
|
progress_y, RED, 4.0);
|
||||||
|
text(cr, &format!("Every {} min", p.nibp_interval_minutes),
|
||||||
|
x, top + height * 0.97, small * 0.85, MUTED, false);
|
||||||
|
|
||||||
|
// Vertical cuff-pressure gauge (0..200 mmHg), always visible when measuring.
|
||||||
|
let gauge_x = right - 15.0;
|
||||||
|
let gauge_top = top + height * 0.31;
|
||||||
|
let gauge_h = height * 0.40;
|
||||||
|
stroke_line(cr, gauge_x, gauge_top, gauge_x, gauge_top + gauge_h, MUTED, 7.0);
|
||||||
|
if in_progress {
|
||||||
|
stroke_line(cr, gauge_x, gauge_top + gauge_h,
|
||||||
|
gauge_x, gauge_top + gauge_h * (1.0 - pressure / 200.0), RED, 6.0);
|
||||||
|
}
|
||||||
|
text(cr, &format!("{:.0}", pressure), gauge_x - 12.0,
|
||||||
|
gauge_top - 3.0, small * 0.75, RED, false);
|
||||||
|
draw_alarm_annotations(cr, &[
|
||||||
|
("SYS", p.alarms.nibp_sys),
|
||||||
|
("MAP", p.alarms.nibp_map),
|
||||||
|
("DIA", p.alarms.nibp_dia),
|
||||||
|
], right, top, height * 0.65, width * 0.72);
|
||||||
|
}
|
||||||
|
|
||||||
fn pleth_trace_enabled(p: &Parameters) -> bool {
|
fn pleth_trace_enabled(p: &Parameters) -> bool {
|
||||||
p.spo2_sensor_attached && p.spo2_quality != Spo2Quality::None
|
p.spo2_sensor_attached && p.spo2_quality != Spo2Quality::None
|
||||||
}
|
}
|
||||||
|
|
||||||
|
#[cfg(test)]
|
||||||
fn spo2_vitals(p: &Parameters, pulse_rate: Option<i32>, signal_lost: bool)
|
fn spo2_vitals(p: &Parameters, pulse_rate: Option<i32>, signal_lost: bool)
|
||||||
-> (String, String, String) {
|
-> (String, String, String) {
|
||||||
match p.spo2_status_during(pulse_rate, signal_lost) {
|
spo2_vitals_at_quality(p, pulse_rate, signal_lost, p.spo2_quality)
|
||||||
|
}
|
||||||
|
|
||||||
|
fn spo2_vitals_at_quality(p: &Parameters, pulse_rate: Option<i32>, signal_lost: bool,
|
||||||
|
quality: Spo2Quality) -> (String, String, String) {
|
||||||
|
match p.spo2_status_at_quality(pulse_rate, signal_lost, quality) {
|
||||||
Spo2Status::NoSensor => (
|
Spo2Status::NoSensor => (
|
||||||
"SpO₂".to_owned(), "NO SENSOR".to_owned(), "PR -- bpm".to_owned()),
|
"SpO₂".to_owned(), "NO SENSOR".to_owned(), "PR -- bpm".to_owned()),
|
||||||
Spo2Status::NoReading => (
|
Spo2Status::NoReading => (
|
||||||
"SpO₂".to_owned(), "NO READING".to_owned(), "PR -- bpm".to_owned()),
|
"SpO₂".to_owned(), "NO READING".to_owned(), "PR -- bpm".to_owned()),
|
||||||
Spo2Status::Available => (
|
Spo2Status::Available => (
|
||||||
format!("SpO₂ {}", p.spo2_quality.stars()),
|
format!("SpO₂ {}", quality.stars()),
|
||||||
p.spo2.to_string(),
|
p.spo2.to_string(),
|
||||||
format!("% PR {} bpm", pulse_rate.unwrap_or_default()),
|
format!("% PR {} bpm", pulse_rate.unwrap_or_default()),
|
||||||
),
|
),
|
||||||
|
|
@ -144,9 +200,8 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64,
|
||||||
let ecg_hr = if p.ecg_rhythm.has_qrs() && p.heart_rate > 0 {
|
let ecg_hr = if p.ecg_rhythm.has_qrs() && p.heart_rate > 0 {
|
||||||
Some(p.heart_rate)
|
Some(p.heart_rate)
|
||||||
} else { None };
|
} else { None };
|
||||||
let spo2_status = p.spo2_status_during(pulse_rate, sim.poor_signal_lost());
|
let spo2_status = p.spo2_status_at_quality(pulse_rate, sim.poor_signal_lost(), sim.spo2_quality(p));
|
||||||
let oxygen = if spo2_status == Spo2Status::Available { Some(p.spo2) } else { None };
|
let oxygen = if spo2_status == Spo2Status::Available { Some(p.spo2) } else { None };
|
||||||
let art_map = mean_arterial_pressure(p.art_systolic, p.art_diastolic);
|
|
||||||
|
|
||||||
let limits: Vec<(&str, AlarmLimits)> = match ch {
|
let limits: Vec<(&str, AlarmLimits)> = match ch {
|
||||||
Channel::Ecg => vec![("HR", p.alarms.hr)],
|
Channel::Ecg => vec![("HR", p.alarms.hr)],
|
||||||
|
|
@ -174,7 +229,8 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64,
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
Channel::Pleth => {
|
Channel::Pleth => {
|
||||||
let (label, value, info) = spo2_vitals(p, pulse_rate, sim.poor_signal_lost());
|
let (label, value, info) = spo2_vitals_at_quality(p, pulse_rate,
|
||||||
|
sim.poor_signal_lost(), sim.spo2_quality(p));
|
||||||
text(cr, &label, x, top + row_h * 0.24, label_size, color, false);
|
text(cr, &label, x, top + row_h * 0.24, label_size, color, false);
|
||||||
let technical_alarm = spo2_status != Spo2Status::Available;
|
let technical_alarm = spo2_status != Spo2Status::Available;
|
||||||
let value_size = if technical_alarm {
|
let value_size = if technical_alarm {
|
||||||
|
|
@ -192,36 +248,27 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64,
|
||||||
}
|
}
|
||||||
Channel::Art => {
|
Channel::Art => {
|
||||||
text(cr, "ART", x, top + row_h * 0.24, label_size, color, false);
|
text(cr, "ART", x, top + row_h * 0.24, label_size, color, false);
|
||||||
if pulse_rate.is_some() {
|
let (sys, dia, map) = sim.displayed_art_pressures(p, pulse_rate.is_some());
|
||||||
draw_pressure_value(cr, p.art_systolic, p.art_diastolic,
|
let sys_text = sys.map_or("--".to_owned(), |v| v.to_string());
|
||||||
x, value_y, number_size * 0.78, width, color,
|
let dia_text = dia.map_or("--".to_owned(), |v| v.to_string());
|
||||||
alarmed(p.alarms.art_sys, Some(p.art_systolic)),
|
draw_pressure_components(cr, &sys_text, &dia_text,
|
||||||
alarmed(p.alarms.art_dia, Some(p.art_diastolic)), flash);
|
x, value_y, number_size * 0.78, width, color,
|
||||||
if p.pulse_pressure_variation > 0 || p.alarms.ppv.enabled() {
|
alarmed(p.alarms.art_sys, sys),
|
||||||
let map_text = art_map.to_string();
|
alarmed(p.alarms.art_dia, dia), flash);
|
||||||
let ppv_text = p.pulse_pressure_variation.to_string();
|
let map_text = map.map_or("--".to_owned(), |v| v.to_string());
|
||||||
draw_alarm_parts(cr, x, info_y, sub_size, width, color, &[
|
if p.pulse_pressure_variation > 0 || p.alarms.ppv.enabled() {
|
||||||
("MAP ", false),
|
let ppv_text = p.pulse_pressure_variation.to_string();
|
||||||
(&map_text, alarmed(p.alarms.art_map, Some(art_map))),
|
draw_alarm_parts(cr, x, info_y, sub_size, width, color, &[
|
||||||
(" · PPV ", false),
|
("MAP ", false),
|
||||||
(&ppv_text, alarmed(p.alarms.ppv, Some(p.pulse_pressure_variation))),
|
(&map_text, alarmed(p.alarms.art_map, map)),
|
||||||
("%", false),
|
(" · PPV ", false),
|
||||||
], flash);
|
(&ppv_text, alarmed(p.alarms.ppv, Some(p.pulse_pressure_variation))),
|
||||||
} else {
|
("%", false),
|
||||||
draw_alarm_inline(cr, x, info_y, sub_size, width, color,
|
], flash);
|
||||||
"MAP ", &art_map.to_string(), " mmHg",
|
|
||||||
alarmed(p.alarms.art_map, Some(art_map)), flash);
|
|
||||||
}
|
|
||||||
} else {
|
} else {
|
||||||
// Without mechanical activity the transducer still reads the
|
draw_alarm_inline(cr, x, info_y, sub_size, width, color,
|
||||||
// slowly drifting 0..5 mmHg pressure. DIA/MAP are indeterminate.
|
"MAP ", &map_text, " mmHg",
|
||||||
let pulseless = !has_capture;
|
alarmed(p.alarms.art_map, map), flash);
|
||||||
let sys = if pulseless { sim.measured_art_pressure() } else { None };
|
|
||||||
let displayed_sys = sys.map_or_else(|| "--".to_owned(), |v| v.to_string());
|
|
||||||
draw_pressure_components(cr, &displayed_sys, "--", x, value_y,
|
|
||||||
number_size * 0.78, width, color,
|
|
||||||
alarmed(p.alarms.art_sys, sys), false, flash);
|
|
||||||
text(cr, "MAP -- mmHg", x, info_y, sub_size, color, false);
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
Channel::Capno => {
|
Channel::Capno => {
|
||||||
|
|
@ -270,17 +317,7 @@ fn draw_alarm_number(cr: &Context, value: &str, x: f64, baseline: f64,
|
||||||
let _ = cr.restore();
|
let _ = cr.restore();
|
||||||
}
|
}
|
||||||
|
|
||||||
/// Draw pressure components independently: only SYS or DIA flashes when it
|
/// Draw SYS and DIA independently; their threshold alarms can invert separately.
|
||||||
/// breaches its respective limit. The separator remains the normal color.
|
|
||||||
#[allow(clippy::too_many_arguments)]
|
|
||||||
fn draw_pressure_value(cr: &Context, systolic: i32, diastolic: i32,
|
|
||||||
x: f64, baseline: f64, nominal_size: f64,
|
|
||||||
available_width: f64, color: Color,
|
|
||||||
sys_alarm: bool, dia_alarm: bool, flash: bool) {
|
|
||||||
draw_pressure_components(cr, &systolic.to_string(), &diastolic.to_string(),
|
|
||||||
x, baseline, nominal_size, available_width, color, sys_alarm, dia_alarm, flash);
|
|
||||||
}
|
|
||||||
|
|
||||||
#[allow(clippy::too_many_arguments)]
|
#[allow(clippy::too_many_arguments)]
|
||||||
fn draw_pressure_components(cr: &Context, sys: &str, dia: &str,
|
fn draw_pressure_components(cr: &Context, sys: &str, dia: &str,
|
||||||
x: f64, baseline: f64, nominal_size: f64,
|
x: f64, baseline: f64, nominal_size: f64,
|
||||||
|
|
@ -392,7 +429,8 @@ fn draw_trace(cr: &Context, channel: Channel, color: Color,
|
||||||
// Disconnected or absent pleth signal: no curve, including historical pulses.
|
// Disconnected or absent pleth signal: no curve, including historical pulses.
|
||||||
if matches!(channel, Channel::Pleth)
|
if matches!(channel, Channel::Pleth)
|
||||||
&& (!pleth_trace_enabled(p)
|
&& (!pleth_trace_enabled(p)
|
||||||
|| p.spo2_status_during(sim.pulse_rate(), sim.poor_signal_lost()) != Spo2Status::Available)
|
|| p.spo2_status_at_quality(sim.pulse_rate(), sim.poor_signal_lost(),
|
||||||
|
sim.spo2_quality(p)) != Spo2Status::Available)
|
||||||
{
|
{
|
||||||
let _ = cr.restore();
|
let _ = cr.restore();
|
||||||
return;
|
return;
|
||||||
|
|
@ -421,7 +459,7 @@ fn draw_trace(cr: &Context, channel: Channel, color: Color,
|
||||||
fn normalized(channel: Channel, s: &Sample, p: &Parameters) -> f64 {
|
fn normalized(channel: Channel, s: &Sample, p: &Parameters) -> f64 {
|
||||||
match channel {
|
match channel {
|
||||||
Channel::Ecg => (0.40 + s.ecg * 0.38).clamp(0.02, 0.98),
|
Channel::Ecg => (0.40 + s.ecg * 0.38).clamp(0.02, 0.98),
|
||||||
Channel::Pleth => (0.10 + pleth_visual_amplitude(s.pleth, s.time, p.spo2_quality) * 0.78)
|
Channel::Pleth => (0.10 + pleth_visual_amplitude(s.pleth, s.time, s.pleth_quality) * 0.78)
|
||||||
.clamp(0.02, 0.98),
|
.clamp(0.02, 0.98),
|
||||||
Channel::Art => (s.art / 200.0).clamp(0.0, 1.0),
|
Channel::Art => (s.art / 200.0).clamp(0.0, 1.0),
|
||||||
Channel::Capno => (0.08 + (s.co2 / f64::from(p.etco2.max(1))) * 0.80)
|
Channel::Capno => (0.08 + (s.co2 / f64::from(p.etco2.max(1))) * 0.80)
|
||||||
|
|
@ -602,7 +640,7 @@ mod tests {
|
||||||
#[test]
|
#[test]
|
||||||
fn arterial_axis_is_absolute_and_fixed_to_200_mmhg() {
|
fn arterial_axis_is_absolute_and_fixed_to_200_mmhg() {
|
||||||
let p = Parameters::default();
|
let p = Parameters::default();
|
||||||
let mut s = Sample { time: 0.0, ecg: 0.0, pleth: 0.0, pleth_valid: true, art: 100.0, co2: 0.0 };
|
let mut s = Sample { time: 0.0, ecg: 0.0, pleth: 0.0, pleth_valid: true, pleth_quality: Spo2Quality::Good, art: 100.0, co2: 0.0 };
|
||||||
assert_eq!(normalized(Channel::Art, &s, &p), 0.5);
|
assert_eq!(normalized(Channel::Art, &s, &p), 0.5);
|
||||||
s.art = 200.0;
|
s.art = 200.0;
|
||||||
assert_eq!(normalized(Channel::Art, &s, &p), 1.0);
|
assert_eq!(normalized(Channel::Art, &s, &p), 1.0);
|
||||||
|
|
|
||||||
|
|
@ -3,6 +3,7 @@
|
||||||
use std::collections::VecDeque;
|
use std::collections::VecDeque;
|
||||||
|
|
||||||
use crate::model::{ArterialShape, CapnoShape, EcgRhythm, Parameters, PulseConduction, Spo2Quality};
|
use crate::model::{ArterialShape, CapnoShape, EcgRhythm, Parameters, PulseConduction, Spo2Quality};
|
||||||
|
use crate::nibp::{CuffZone, NibpMachine, NibpReading};
|
||||||
|
|
||||||
const SAMPLE_STEP: f64 = 0.004; // 250 Hz; adequately samples the QRS upstroke
|
const SAMPLE_STEP: f64 = 0.004; // 250 Hz; adequately samples the QRS upstroke
|
||||||
const HISTORY_SECONDS: f64 = 10.0;
|
const HISTORY_SECONDS: f64 = 10.0;
|
||||||
|
|
@ -33,6 +34,7 @@ pub struct Sample {
|
||||||
pub ecg: f64, // arbitrary amplitude
|
pub ecg: f64, // arbitrary amplitude
|
||||||
pub pleth: f64, // attenuated, low-pass-filtered amplitude 0..1
|
pub pleth: f64, // attenuated, low-pass-filtered amplitude 0..1
|
||||||
pub pleth_valid: bool, // gaps during intermittent signal dropout
|
pub pleth_valid: bool, // gaps during intermittent signal dropout
|
||||||
|
pub pleth_quality: Spo2Quality, // effective quality at sample time
|
||||||
pub art: f64, // absolute pressure in mmHg; display clips above 200
|
pub art: f64, // absolute pressure in mmHg; display clips above 200
|
||||||
pub co2: f64, // mmHg
|
pub co2: f64, // mmHg
|
||||||
}
|
}
|
||||||
|
|
@ -98,6 +100,8 @@ pub struct Simulator {
|
||||||
previous_conduction: PulseConduction,
|
previous_conduction: PulseConduction,
|
||||||
previous_heart_rate: i32,
|
previous_heart_rate: i32,
|
||||||
poor_signal_outages: PoorSignalOutages,
|
poor_signal_outages: PoorSignalOutages,
|
||||||
|
nibp: NibpMachine,
|
||||||
|
art_hold_pressure: Option<f64>,
|
||||||
pending_time: f64,
|
pending_time: f64,
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
@ -116,6 +120,8 @@ impl Simulator {
|
||||||
previous_conduction: params.pulse_conduction,
|
previous_conduction: params.pulse_conduction,
|
||||||
previous_heart_rate: params.heart_rate,
|
previous_heart_rate: params.heart_rate,
|
||||||
poor_signal_outages: PoorSignalOutages::new(),
|
poor_signal_outages: PoorSignalOutages::new(),
|
||||||
|
nibp: NibpMachine::new(),
|
||||||
|
art_hold_pressure: None,
|
||||||
pending_time: 0.0,
|
pending_time: 0.0,
|
||||||
};
|
};
|
||||||
// Prepopulate the trace and pulse history, including the initial pulse rate.
|
// Prepopulate the trace and pulse history, including the initial pulse rate.
|
||||||
|
|
@ -138,6 +144,53 @@ impl Simulator {
|
||||||
self.poor_signal_outages.active
|
self.poor_signal_outages.active
|
||||||
}
|
}
|
||||||
|
|
||||||
|
pub fn nibp(&self) -> &NibpMachine { &self.nibp }
|
||||||
|
|
||||||
|
pub fn time(&self) -> f64 { self.time }
|
||||||
|
|
||||||
|
pub fn spo2_quality(&self, p: &Parameters) -> Spo2Quality {
|
||||||
|
self.nibp.effective_spo2_quality(self.time, p)
|
||||||
|
}
|
||||||
|
|
||||||
|
pub fn start_nibp_now(&mut self, p: &Parameters) {
|
||||||
|
let quality = self.nibp_start_quality(p);
|
||||||
|
self.nibp.measure_now(self.time, p, quality);
|
||||||
|
}
|
||||||
|
|
||||||
|
fn nibp_start_quality(&self, p: &Parameters) -> Spo2Quality {
|
||||||
|
if !p.spo2_sensor_attached || self.poor_signal_outages.active {
|
||||||
|
Spo2Quality::None
|
||||||
|
} else {
|
||||||
|
p.spo2_quality
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
/// Three displayed arterial values track the cuff-altered transducer curve.
|
||||||
|
pub fn displayed_art_pressures(&self, p: &Parameters, has_capture: bool)
|
||||||
|
-> (Option<i32>, Option<i32>, Option<i32>) {
|
||||||
|
if !has_capture {
|
||||||
|
return (self.measured_art_pressure(), None, None);
|
||||||
|
}
|
||||||
|
if p.nibp_cuff_on_art {
|
||||||
|
match self.nibp.cuff_zone(self.time, p) {
|
||||||
|
CuffZone::Occluded => {
|
||||||
|
let v = self.measured_art_pressure();
|
||||||
|
return (v, v, v);
|
||||||
|
}
|
||||||
|
CuffZone::Partial => {
|
||||||
|
let target = self.nibp.reading().map_or(p.nibp_systolic, |r| r.systolic) as f64;
|
||||||
|
let cuff = self.nibp.cuff_pressure(self.time);
|
||||||
|
let sys = target.max(cuff).round() as i32;
|
||||||
|
let dia = target.min(cuff).round() as i32;
|
||||||
|
return (Some(sys), Some(dia), Some(crate::model::mean_arterial_pressure(sys, dia)));
|
||||||
|
}
|
||||||
|
CuffZone::Free => {}
|
||||||
|
}
|
||||||
|
}
|
||||||
|
(Some(p.art_systolic), Some(p.art_diastolic),
|
||||||
|
Some(crate::model::mean_arterial_pressure(p.art_systolic, p.art_diastolic)))
|
||||||
|
}
|
||||||
|
|
||||||
/// Last arterial transducer sample, in mmHg (including slow 0..5 drift).
|
/// Last arterial transducer sample, in mmHg (including slow 0..5 drift).
|
||||||
pub fn measured_art_pressure(&self) -> Option<i32> {
|
pub fn measured_art_pressure(&self) -> Option<i32> {
|
||||||
self.samples.back().map(|sample| sample.art.round() as i32)
|
self.samples.back().map(|sample| sample.art.round() as i32)
|
||||||
|
|
@ -168,6 +221,10 @@ impl Simulator {
|
||||||
self.time += SAMPLE_STEP;
|
self.time += SAMPLE_STEP;
|
||||||
self.poor_signal_outages.update(self.time,
|
self.poor_signal_outages.update(self.time,
|
||||||
params.spo2_quality == Spo2Quality::Poor && params.spo2_sensor_attached);
|
params.spo2_quality == Spo2Quality::Poor && params.spo2_sensor_attached);
|
||||||
|
// Snapshot the unoccluded sensor quality at the start of a cuff cycle.
|
||||||
|
// Cuff-induced signal loss during that cycle must not change its duration.
|
||||||
|
let start_quality = self.nibp_start_quality(params);
|
||||||
|
self.nibp.update(self.time, params, start_quality);
|
||||||
|
|
||||||
if params.ecg_rhythm != self.previous_rhythm
|
if params.ecg_rhythm != self.previous_rhythm
|
||||||
|| params.pulse_conduction != self.previous_conduction
|
|| params.pulse_conduction != self.previous_conduction
|
||||||
|
|
@ -233,7 +290,8 @@ impl Simulator {
|
||||||
}
|
}
|
||||||
|
|
||||||
let ecg = ecg_amplitude(self.ecg_phase, self.time, params.ecg_rhythm, params.heart_rate);
|
let ecg = ecg_amplitude(self.ecg_phase, self.time, params.ecg_rhythm, params.heart_rate);
|
||||||
let (art, pleth_target) = self.mechanical_signals(params);
|
let (normal_art, pleth_target) = self.mechanical_signals(params);
|
||||||
|
let art = self.art_with_cuff(normal_art, params);
|
||||||
let smoothing = 1.0 - (-SAMPLE_STEP / PLETH_FILTER_TAU).exp();
|
let smoothing = 1.0 - (-SAMPLE_STEP / PLETH_FILTER_TAU).exp();
|
||||||
self.filtered_pleth += smoothing * (pleth_target - self.filtered_pleth);
|
self.filtered_pleth += smoothing * (pleth_target - self.filtered_pleth);
|
||||||
let pleth = self.filtered_pleth.clamp(0.0, 1.0);
|
let pleth = self.filtered_pleth.clamp(0.0, 1.0);
|
||||||
|
|
@ -242,15 +300,52 @@ impl Simulator {
|
||||||
capno_amplitude(self.respiratory_phase, params.capno_shape)
|
capno_amplitude(self.respiratory_phase, params.capno_shape)
|
||||||
};
|
};
|
||||||
|
|
||||||
|
let pleth_quality = self.spo2_quality(params);
|
||||||
let pleth_valid = params.spo2_sensor_attached
|
let pleth_valid = params.spo2_sensor_attached
|
||||||
&& params.spo2_quality != Spo2Quality::None
|
&& pleth_quality != Spo2Quality::None
|
||||||
&& !self.poor_signal_outages.active;
|
&& !self.poor_signal_outages.active;
|
||||||
self.samples.push_back(Sample { time: self.time, ecg, pleth, pleth_valid, art, co2 });
|
self.samples.push_back(Sample {
|
||||||
|
time: self.time, ecg, pleth, pleth_valid, pleth_quality, art, co2,
|
||||||
|
});
|
||||||
while self.samples.front().is_some_and(|first| first.time < self.time - HISTORY_SECONDS) {
|
while self.samples.front().is_some_and(|first| first.time < self.time - HISTORY_SECONDS) {
|
||||||
self.samples.pop_front();
|
self.samples.pop_front();
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
fn art_with_cuff(&mut self, normal_art: f64, params: &Parameters) -> f64 {
|
||||||
|
if !params.nibp_cuff_on_art || !params.ecg_rhythm.can_generate_pulse()
|
||||||
|
|| params.pulse_conduction == PulseConduction::None || params.heart_rate <= 0
|
||||||
|
{
|
||||||
|
self.art_hold_pressure = None;
|
||||||
|
return normal_art;
|
||||||
|
}
|
||||||
|
match self.nibp.cuff_zone(self.time, params) {
|
||||||
|
CuffZone::Free => {
|
||||||
|
self.art_hold_pressure = None;
|
||||||
|
normal_art
|
||||||
|
}
|
||||||
|
CuffZone::Occluded => {
|
||||||
|
if let Some(held) = self.art_hold_pressure {
|
||||||
|
held
|
||||||
|
} else {
|
||||||
|
let held = self.samples.back().map_or(normal_art, |s| s.art);
|
||||||
|
self.art_hold_pressure = Some(held);
|
||||||
|
held
|
||||||
|
}
|
||||||
|
}
|
||||||
|
CuffZone::Partial => {
|
||||||
|
self.art_hold_pressure = None;
|
||||||
|
let cuff = self.nibp.cuff_pressure(self.time);
|
||||||
|
let target = f64::from(self.nibp.reading().map_or(
|
||||||
|
params.nibp_systolic, |r: NibpReading| r.systolic));
|
||||||
|
let original_span = f64::from((params.art_systolic - params.art_diastolic).max(1));
|
||||||
|
let shape = ((normal_art - f64::from(params.art_diastolic)) / original_span)
|
||||||
|
.clamp(0.0, 1.0);
|
||||||
|
(cuff + (target - cuff) * shape).clamp(0.0, 260.0)
|
||||||
|
}
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
fn mechanical_signals(&self, params: &Parameters) -> (f64, f64) {
|
fn mechanical_signals(&self, params: &Parameters) -> (f64, f64) {
|
||||||
let systolic = params.art_systolic.clamp(0, 200) as f64;
|
let systolic = params.art_systolic.clamp(0, 200) as f64;
|
||||||
let diastolic = params.art_diastolic.clamp(0, 200).min(params.art_systolic.clamp(0, 200)) as f64;
|
let diastolic = params.art_diastolic.clamp(0, 200).min(params.art_systolic.clamp(0, 200)) as f64;
|
||||||
|
|
@ -603,6 +698,31 @@ mod tests {
|
||||||
assert!(sim.samples.back().unwrap().pleth_valid);
|
assert!(sim.samples.back().unwrap().pleth_valid);
|
||||||
}
|
}
|
||||||
|
|
||||||
|
#[test]
|
||||||
|
fn nibp_cuff_can_occlude_art_and_reduce_spo2_quality() {
|
||||||
|
let p = Parameters {
|
||||||
|
nibp_cuff_on_spo2: true,
|
||||||
|
nibp_cuff_on_art: true,
|
||||||
|
..Parameters::default()
|
||||||
|
};
|
||||||
|
let mut sim = Simulator::new(&p);
|
||||||
|
while sim.time < 3.0 { sim.step(&p); }
|
||||||
|
assert_eq!(sim.nibp.cuff_zone(sim.time, &p), CuffZone::Occluded);
|
||||||
|
assert_eq!(sim.spo2_quality(&p), Spo2Quality::None);
|
||||||
|
let held = sim.samples.back().unwrap().art;
|
||||||
|
for _ in 0..50 { sim.step(&p); }
|
||||||
|
assert!((sim.samples.back().unwrap().art - held).abs() < 1e-9);
|
||||||
|
assert!(!sim.samples.back().unwrap().pleth_valid);
|
||||||
|
let (sys, dia, map) = sim.displayed_art_pressures(&p, true);
|
||||||
|
assert!(sys.is_some() && sys == dia && dia == map);
|
||||||
|
while sim.time < 10.0 { sim.step(&p); }
|
||||||
|
assert_eq!(sim.nibp.cuff_zone(sim.time, &p), CuffZone::Partial);
|
||||||
|
assert_eq!(sim.spo2_quality(&p), Spo2Quality::Poor);
|
||||||
|
while sim.time < 19.0 { sim.step(&p); }
|
||||||
|
assert_eq!(sim.nibp.cuff_zone(sim.time, &p), CuffZone::Free);
|
||||||
|
assert_eq!(sim.spo2_quality(&p), Spo2Quality::Good);
|
||||||
|
}
|
||||||
|
|
||||||
#[test]
|
#[test]
|
||||||
fn pulse_rate_follows_two_to_one_capture() {
|
fn pulse_rate_follows_two_to_one_capture() {
|
||||||
let p = Parameters { pulse_conduction: PulseConduction::TwoToOne, ..Parameters::default() };
|
let p = Parameters { pulse_conduction: PulseConduction::TwoToOne, ..Parameters::default() };
|
||||||
|
|
|
||||||
|
|
@ -15,7 +15,7 @@ use crate::simulation::Simulator;
|
||||||
type SharedParams = Rc<RefCell<Parameters>>;
|
type SharedParams = Rc<RefCell<Parameters>>;
|
||||||
|
|
||||||
// Match the RGB colors of the monitor traces (see render.rs).
|
// Match the RGB colors of the monitor traces (see render.rs).
|
||||||
// NIBP uses the same light grey as the NIBP footer and capnography.
|
// NIBP shares the arterial-pressure red; capnography is light grey.
|
||||||
type AccentColor = (f64, f64, f64);
|
type AccentColor = (f64, f64, f64);
|
||||||
const ECG_GREEN: AccentColor = (0.26, 1.0, 0.39);
|
const ECG_GREEN: AccentColor = (0.26, 1.0, 0.39);
|
||||||
const SPO2_YELLOW: AccentColor = (1.0, 0.85, 0.17);
|
const SPO2_YELLOW: AccentColor = (1.0, 0.85, 0.17);
|
||||||
|
|
@ -25,8 +25,8 @@ const MONITOR_GREY: AccentColor = (0.80, 0.84, 0.87);
|
||||||
pub fn create_windows(app: &Application) {
|
pub fn create_windows(app: &Application) {
|
||||||
let parameters = Rc::new(RefCell::new(Parameters::default()));
|
let parameters = Rc::new(RefCell::new(Parameters::default()));
|
||||||
let simulator = Rc::new(RefCell::new(Simulator::new(¶meters.borrow())));
|
let simulator = Rc::new(RefCell::new(Simulator::new(¶meters.borrow())));
|
||||||
let monitor = create_monitor(app, parameters.clone(), simulator);
|
let monitor = create_monitor(app, parameters.clone(), simulator.clone());
|
||||||
let admin = create_admin(app, parameters, &monitor);
|
let admin = create_admin(app, parameters, simulator, &monitor);
|
||||||
|
|
||||||
// Present monitor first, then leave controls in the foreground.
|
// Present monitor first, then leave controls in the foreground.
|
||||||
monitor.present();
|
monitor.present();
|
||||||
|
|
@ -89,6 +89,7 @@ fn create_monitor(app: &Application, params: SharedParams,
|
||||||
}
|
}
|
||||||
|
|
||||||
fn create_admin(app: &Application, params: SharedParams,
|
fn create_admin(app: &Application, params: SharedParams,
|
||||||
|
simulator: Rc<RefCell<Simulator>>,
|
||||||
monitor: &ApplicationWindow) -> ApplicationWindow {
|
monitor: &ApplicationWindow) -> ApplicationWindow {
|
||||||
let window = ApplicationWindow::builder()
|
let window = ApplicationWindow::builder()
|
||||||
.application(app)
|
.application(app)
|
||||||
|
|
@ -283,9 +284,9 @@ ART and pleth are delayed. VT can be perfusing; PVT, VF and asystole are pulsele
|
||||||
};
|
};
|
||||||
});
|
});
|
||||||
|
|
||||||
let nibp = group(&controls, "Non-invasive blood pressure (NIBP)", Some(MONITOR_GREY));
|
let nibp = group(&controls, "Non-invasive blood pressure (NIBP)", Some(ART_RED));
|
||||||
add_visibility(&nibp, params.borrow().show_nibp, params.clone(), |p, show| p.show_nibp = show);
|
add_visibility(&nibp, params.borrow().show_nibp, params.clone(), |p, show| p.show_nibp = show);
|
||||||
let (nibp_sys_row, _, _) = add_numeric(&nibp, "Systolic", "mmHg", 0, 260, params.borrow().nibp_systolic,
|
let (nibp_sys_row, _, _) = add_numeric(&nibp, "Initial systolic", "mmHg", 0, 260, params.borrow().nibp_systolic,
|
||||||
params.clone(), |p, v| p.nibp_systolic = v);
|
params.clone(), |p, v| p.nibp_systolic = v);
|
||||||
alarm_editors.push((add_alarm_limits(&nibp_sys_row, "", "", 260,
|
alarm_editors.push((add_alarm_limits(&nibp_sys_row, "", "", 260,
|
||||||
params.borrow().alarms.nibp_sys, params.clone(), |p, v| p.alarms.nibp_sys = v,
|
params.borrow().alarms.nibp_sys, params.clone(), |p, v| p.alarms.nibp_sys = v,
|
||||||
|
|
@ -293,12 +294,49 @@ ART and pleth are delayed. VT can be perfusing; PVT, VF and asystole are pulsele
|
||||||
alarm_editors.push((add_alarm_limits(&nibp, "MAP (derived)", "mmHg", 260,
|
alarm_editors.push((add_alarm_limits(&nibp, "MAP (derived)", "mmHg", 260,
|
||||||
params.borrow().alarms.nibp_map, params.clone(), |p, v| p.alarms.nibp_map = v,
|
params.borrow().alarms.nibp_map, params.clone(), |p, v| p.alarms.nibp_map = v,
|
||||||
&preset_dropdown, &updating_preset), |s| s.nibp_map));
|
&preset_dropdown, &updating_preset), |s| s.nibp_map));
|
||||||
let (nibp_dia_row, _, _) = add_numeric(&nibp, "Diastolic", "mmHg", 0, 200, params.borrow().nibp_diastolic,
|
let (nibp_dia_row, _, _) = add_numeric(&nibp, "Initial diastolic", "mmHg", 0, 200, params.borrow().nibp_diastolic,
|
||||||
params.clone(), |p, v| p.nibp_diastolic = v);
|
params.clone(), |p, v| p.nibp_diastolic = v);
|
||||||
alarm_editors.push((add_alarm_limits(&nibp_dia_row, "", "", 200,
|
alarm_editors.push((add_alarm_limits(&nibp_dia_row, "", "", 200,
|
||||||
params.borrow().alarms.nibp_dia, params.clone(), |p, v| p.alarms.nibp_dia = v,
|
params.borrow().alarms.nibp_dia, params.clone(), |p, v| p.alarms.nibp_dia = v,
|
||||||
&preset_dropdown, &updating_preset), |s| s.nibp_dia));
|
&preset_dropdown, &updating_preset), |s| s.nibp_dia));
|
||||||
|
|
||||||
|
let _nibp_interval = add_dropdown_at(&nibp, "Measurement interval",
|
||||||
|
&["1 min", "3 min", "5 min", "10 min", "20 min", "30 min", "60 min"],
|
||||||
|
2, params.clone(), |p, selected| {
|
||||||
|
p.nibp_interval_minutes = match selected {
|
||||||
|
0 => 1, 1 => 3, 2 => 5, 3 => 10, 4 => 20, 5 => 30, _ => 60,
|
||||||
|
};
|
||||||
|
});
|
||||||
|
for (caption, current, update) in [
|
||||||
|
("No reading (simulate failure)", params.borrow().nibp_no_reading,
|
||||||
|
(|p: &mut Parameters, on| p.nibp_no_reading = on) as fn(&mut Parameters, bool)),
|
||||||
|
("Cuff on SpO₂ extremity", params.borrow().nibp_cuff_on_spo2,
|
||||||
|
(|p: &mut Parameters, on| p.nibp_cuff_on_spo2 = on) as fn(&mut Parameters, bool)),
|
||||||
|
("Cuff on ART extremity", params.borrow().nibp_cuff_on_art,
|
||||||
|
(|p: &mut Parameters, on| p.nibp_cuff_on_art = on) as fn(&mut Parameters, bool)),
|
||||||
|
] {
|
||||||
|
let checkbox = gtk::CheckButton::with_label(caption);
|
||||||
|
checkbox.set_active(current);
|
||||||
|
checkbox.connect_toggled({
|
||||||
|
let params = params.clone();
|
||||||
|
move |button| update(&mut params.borrow_mut(), button.is_active())
|
||||||
|
});
|
||||||
|
nibp.append(&checkbox);
|
||||||
|
}
|
||||||
|
let measure_now = gtk::Button::with_label("Measure now");
|
||||||
|
measure_now.connect_clicked({
|
||||||
|
let params = params.clone();
|
||||||
|
let simulator = simulator.clone();
|
||||||
|
move |_| simulator.borrow_mut().start_nibp_now(¶ms.borrow())
|
||||||
|
});
|
||||||
|
nibp.append(&measure_now);
|
||||||
|
let nibp_hint = gtk::Label::new(Some(
|
||||||
|
"First successful NIBP: instructor SYS/DIA above. Later values: simulated IBP-dependent readings."
|
||||||
|
));
|
||||||
|
nibp_hint.set_xalign(0.0);
|
||||||
|
nibp_hint.set_wrap(true);
|
||||||
|
nibp.append(&nibp_hint);
|
||||||
|
|
||||||
let capno = group(&controls, "Capnography", Some(MONITOR_GREY));
|
let capno = group(&controls, "Capnography", Some(MONITOR_GREY));
|
||||||
add_visibility(&capno, params.borrow().show_capno, params.clone(), |p, show| p.show_capno = show);
|
add_visibility(&capno, params.borrow().show_capno, params.clone(), |p, show| p.show_capno = show);
|
||||||
add_dropdown(&capno, "Capnogram", &["Normal", "Obstructive / shark fin"],
|
add_dropdown(&capno, "Capnogram", &["Normal", "Obstructive / shark fin"],
|
||||||
|
|
|
||||||
Loading…
Reference in a new issue