Commit graph SimPaM/patient-monitor-simulation/README.de.md.orig
Author SHA1 Message Date
00dc22b1aa v0.6.4 — NIBP touch controls restored
The monitor-side NIBP settings menu again contains **Measure now**,
**Automatic measurement ON/OFF** and the **measurement interval** (1, 3, 5,
10, 20, 30, 60 minutes). These controls are above the horizontal SYS/MAP/DIA
alarm matrix and share its monochrome touchscreen styling. Auto and interval
are saved with Apply; Measure now starts a cuff cycle immediately regardless
of Auto. Both monitor and Admin display the selected settings. Other monitor
menus remain limited to alarm thresholds; NIBP cuff placement, the simulated
failed-reading option and non-NIBP signal settings remain Admin-only.
2026-11-12 20:07:35 +01:00
54012ab960 v0.6.3 2026-11-12 19:31:05 +01:00
89c1c8f396 v0.6.1 — Alarm-only monitor touch menus
The ECG, SpO₂, ART, CO₂ and NIBP touch menus now edit only lower/upper
alarm limits. Removed ECG lead, signal/sensor, waveform and all NIBP
measurement controls from monitor-side menus. These remain available in
Admin, including manual NIBP measurement and Auto ON/OFF. No physiological
model, alarm evaluation or NIBP startup behavior was changed.
2026-11-12 19:08:11 +01:00
41e1971fae v0.6.0 — Additional touchscreen modules and NIBP manual-first startup
Added touch/click settings panels for SpO₂, ART, CO₂ and the bottom-right
NIBP cell. Their threshold editors use large, unit-specific +/− and ON/OFF
controls; the panels expose relevant waveform/sensor options and stay
synchronized with Admin. NIBP additionally provides interval selection,
manual **Measure now**, Auto ON/OFF and cuff options. Startup no longer
initiates a cuff cycle or shows any NIBP reading; Auto is OFF by default.
Existing NIBP cycle physics and signal quality behavior are unchanged.
2026-11-12 16:40:51 +01:00
3f191e4c46 v0.5.9 — Touch-optimized ECG settings
Restyled the ECG settings window with light-grey text/controls, a neutral
0.8-pixel outer border and thin 0.8-pixel Cairo separators matching the
monitor. Replaced the on-monitor HR limit text entries with large 5-bpm
**−/+** buttons and independent **ON/OFF** controls; the ECG lead remains a
touch-selectable dropdown. Pending changes still require Apply, and Cancel
leaves the shared parameters unchanged. No signal generation was altered.
2026-11-12 16:36:07 +01:00
14ee042a0a v0.5.8 — ECG touchscreen controls 2026-11-12 16:10:57 +01:00
8225ac8e70 v0.5.5: try to fix tests 2026-11-12 15:16:24 +01:00
483a3c3d61 v0.5.4: Chest compressions 2026-11-12 15:11:04 +01:00
3be878804b v0.5.1: fix monitor Layout 2026-11-12 14:10:46 +01:00