Commit graph SimPaM/patient-monitor-simulation/Cargo.lock
Author SHA1 Message Date
c366c4f1d7 v0.6.9: Actions & Occurrences 2026-11-13 11:56:44 +01:00
5665d68db0 moce patches 2026-11-13 10:59:24 +01:00
2c0dc760d9 v0.6.7: fix: Smooth HR transitions 2026-11-12 22:49:12 +01:00
f98fc7412f v0.6.6 — Optional QRS/pulse beep
Added a separate **QRS tone** checkbox (enabled by default). An 85 ms
single-note beep follows actual ECG or mechanical beat events. With a valid
SpO₂ reading, the delayed pleth pulse determines the timing and the oxygen
saturation determines the pitch in eleven steps from 740 to 87 Hz; otherwise
ECG QRS or ART pulses trigger a fixed 500 Hz tone. The two-tone alarm sounds
remain unchanged. Added regression tests for band boundaries, event selection
and single-tone WAV output.
2026-11-12 22:36:24 +01:00
196ed03a3d v0.6.5 — Two-tone audible alarms
Both standard/technical and critical alarm sounds now consist of two distinct
successive pitches. Critical alarms retain their priority and faster repeat
interval; standard alarms retain their slower cadence. The Admin test button
plays the standard two-tone alert. A single QRS beep is reserved for a later
release and is not generated yet. No visual alarm or simulation logic changed.
2026-11-12 21:04:35 +01:00
00dc22b1aa v0.6.4 — NIBP touch controls restored
The monitor-side NIBP settings menu again contains **Measure now**,
**Automatic measurement ON/OFF** and the **measurement interval** (1, 3, 5,
10, 20, 30, 60 minutes). These controls are above the horizontal SYS/MAP/DIA
alarm matrix and share its monochrome touchscreen styling. Auto and interval
are saved with Apply; Measure now starts a cuff cycle immediately regardless
of Auto. Both monitor and Admin display the selected settings. Other monitor
menus remain limited to alarm thresholds; NIBP cuff placement, the simulated
failed-reading option and non-NIBP signal settings remain Admin-only.
2026-11-12 20:07:35 +01:00
54012ab960 v0.6.3 2026-11-12 19:31:05 +01:00
89c1c8f396 v0.6.1 — Alarm-only monitor touch menus
The ECG, SpO₂, ART, CO₂ and NIBP touch menus now edit only lower/upper
alarm limits. Removed ECG lead, signal/sensor, waveform and all NIBP
measurement controls from monitor-side menus. These remain available in
Admin, including manual NIBP measurement and Auto ON/OFF. No physiological
model, alarm evaluation or NIBP startup behavior was changed.
2026-11-12 19:08:11 +01:00
41e1971fae v0.6.0 — Additional touchscreen modules and NIBP manual-first startup
Added touch/click settings panels for SpO₂, ART, CO₂ and the bottom-right
NIBP cell. Their threshold editors use large, unit-specific +/− and ON/OFF
controls; the panels expose relevant waveform/sensor options and stay
synchronized with Admin. NIBP additionally provides interval selection,
manual **Measure now**, Auto ON/OFF and cuff options. Startup no longer
initiates a cuff cycle or shows any NIBP reading; Auto is OFF by default.
Existing NIBP cycle physics and signal quality behavior are unchanged.
2026-11-12 16:40:51 +01:00
3f191e4c46 v0.5.9 — Touch-optimized ECG settings
Restyled the ECG settings window with light-grey text/controls, a neutral
0.8-pixel outer border and thin 0.8-pixel Cairo separators matching the
monitor. Replaced the on-monitor HR limit text entries with large 5-bpm
**−/+** buttons and independent **ON/OFF** controls; the ECG lead remains a
touch-selectable dropdown. Pending changes still require Apply, and Cancel
leaves the shared parameters unchanged. No signal generation was altered.
2026-11-12 16:36:07 +01:00
14ee042a0a v0.5.8 — ECG touchscreen controls 2026-11-12 16:10:57 +01:00
a09cd2c4ee v0.5.7 — Four-group numerical measurement row 2026-11-12 16:02:08 +01:00
c9a5e14567 v0.5.6 — CPR pleth filter persistence
Corrects the underlying cause of the v0.5.5 test failure: in pulseless rhythms, the simulation had reset the pleth low-pass filter at every 250 Hz sample, preventing CPR-induced signals from accumulating. The filter now persists during good-quality chest compressions while QRS-triggered mechanical pulses are still cleared. Stopping CPR in VF/PVT immediately restores no reading. Additional regression coverage includes PVT.
2026-11-12 15:21:34 +01:00
8225ac8e70 v0.5.5: try to fix tests 2026-11-12 15:16:24 +01:00
483a3c3d61 v0.5.4: Chest compressions 2026-11-12 15:11:04 +01:00
fcd8c1146f v0.5.3: add alarm sounds 2026-11-12 14:34:31 +01:00
4eb67a76ec v0.5.2: monitor layout change 2026-11-12 14:21:33 +01:00
3be878804b v0.5.1: fix monitor Layout 2026-11-12 14:10:46 +01:00
ef269099bd v0.5.0: tweak NIBP 2026-11-12 14:07:59 +01:00
e831364e43 admin interface: design tweaks 2026-11-12 12:47:47 +01:00
d4162c49e8 v0.4.3: Debug and optimize alarms and rhythms 2026-11-12 12:30:54 +01:00
5e397019fc v0.4.2: add PVT 2026-11-12 12:08:46 +01:00
5b6fbb8766 v0.4.1: optimize alarms 2026-11-12 11:47:38 +01:00
49c25bf5bb v0.4.0: add alarms 2026-11-12 11:30:50 +01:00
35a380b808 v0.3.2 2026-11-12 10:43:11 +01:00
788c68a1d8 Initial commit 2026-11-12 09:36:13 +01:00