SimPaM/patches/patient-monitor-simulation-v0.5.3-to-v0.5.4.patch
2026-11-13 10:59:24 +01:00

764 lines
34 KiB
Diff
Raw Permalink Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

diff --git a/Cargo.toml b/Cargo.toml
index debf638..d2a7098 100644
--- a/Cargo.toml
+++ b/Cargo.toml
@@ -1,6 +1,6 @@
[package]
name = "patient-monitor-simulation"
-version = "0.5.3"
+version = "0.5.4"
edition = "2021"
license = "MIT"
description = "Synthetic patient-monitor simulation for teaching (not for clinical use)"
diff --git a/README.de.md b/README.de.md
index 374281f..f7c5ba2 100644
--- a/README.de.md
+++ b/README.de.md
@@ -1,4 +1,4 @@
-# Patient Monitor Simulation (PaMSim) — v0.5.3
+# Patient Monitor Simulation (PaMSim) — v0.5.4
Ein mit Rust und GTK4 entwickelter Patient*innenmonitor-Simulator mit zwei Fenstern für die Lehre unter Fedora Linux.
@@ -6,6 +6,53 @@ Ein mit Rust und GTK4 entwickelter Patient*innenmonitor-Simulator mit zwei Fenst
> EKG, invasive arterielle Druckkurve, Plethysmogramm und Kapnogramm sind schematische mathematische Annäherungen.
> Die Simulation wurde nicht klinisch validiert und ist kein Medizinprodukt.
+## Thoraxkompressionen (v0.5.4)
+
+Im Admin-Bereich **Chest compressions** startet die grüne Schaltfläche
+**Start Chest Compressions** die Simulation. Während aktiver Kompressionen
+wechselt sie zu **Stop Chest Compressions** mit rotem Hintergrund.
+Die **Compression quality** kann jederzeit auf **Good**, **Adequate**
+(Standard), **Poor** oder **Bad** gestellt werden.
+
+- Die Kompressionsfrequenz schwankt zufällig im Bereich **90–110/min**;
+ für jeden Druckstoß werden Frequenz und Druckhöhe neu festgelegt.
+ Der eingestellte EKG-Rhythmus und die elektrische Herzfrequenz bleiben
+ unverändert.
+- Das EKG wird durch kompressionssynchrone Bewegungsartefakte überlagert.
+ Besteht ein **eigener arterieller Kreislauf**, bleibt die ursprüngliche
+ Druckkurve bestehen, wird jedoch durch Kompressionen verzerrt.
+- **Ohne eigenständige arterielle Pulsation** (beispielsweise bei KF, PVT,
+ Asystolie oder PEA) erzeugen wirksame Kompressionen breite, stumpfe
+ arterielle Druckwellen:
+
+ | Kompressionsqualität | Systolischer ART-Spitzendruck |
+ | --- | --- |
+ | Good | 90 mmHg ±10 % (81–99 mmHg) |
+ | Adequate (Standard) | 70 mmHg ±10 % (63–77 mmHg) |
+ | Poor | 50 mmHg, +10 % / −50 % (25–55 mmHg) |
+ | Bad | Kein durch Kompressionen erzeugter Druck; Grundschwankung von 0–5 mmHg |
+
+ Bei fehlender Eigenpulsation zeigt **ART SYS** den Spitzendruck der
+ aktuellen Kompression; **DIA/MAP** bleiben `--`, da sie aus der synthetischen
+ Kurve nicht verlässlich bestimmt werden.
+- Ein SpO₂-Messwert und ein Plethysmogramm werden während laufender
+ Kompressionen **nur bei Qualität Good** angezeigt, vorausgesetzt, der Sensor
+ ist angeschlossen und nicht durch eine NIBP-Manschette okkludiert.
+ Die angezeigte Signalqualität beträgt unabhängig von der Grundeinstellung
+ **Poor (★)**. Die angezeigte **PR folgt der Kompressionsfrequenz (90–110/min)**,
+ nicht der EKG-Frequenz. Bei Adequate, Poor oder Bad erscheint **NO READING**,
+ bei abgezogenem Sensor **NO SENSOR**. Die durch Kompressionen erzwungene
+ Signalqualität Poor führt nicht zu den sonst üblichen periodischen
+ Aussetzern; bei regulärer Grundeinstellung Poor gelten diese nach Ende
+ der Kompressionen wieder.
+- Die bestehenden Rhythmus- und Grenzwertalarme bleiben aktiv. ART-SYS-Grenzen
+ beziehen sich dabei auf die Kompressionsspitzen. Die NIBP-Messintervalle bleiben unverändert; die Dauer eines Messzyklus
+ richtet sich weiterhin nach der wirksamen SpO₂-Signalqualität beim Start.
+
+**Hinweis:** Druckwerte und Signalformen sind didaktisch gewählt und nicht
+klinisch validiert. Aus dieser Simulation darf keine reale Wirksamkeit von
+Reanimationsmaßnahmen abgeleitet werden.
+
## Installation, Kompilierung und Start unter Fedora
```bash
diff --git a/README.md b/README.md
index 20d5943..30ec481 100644
--- a/README.md
+++ b/README.md
@@ -1,4 +1,4 @@
-# Patient Monitor Simulation (PaMSim) — v0.5.3
+# Patient Monitor Simulation (PaMSim) — v0.5.4
A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux.
@@ -6,6 +6,47 @@ A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux.
> plethysmography and capnography are schematic mathematical approximations. The
> simulation has no clinical validation and is not a medical device.
+## Chest compressions (v0.5.4)
+
+The **Chest compressions** Admin group provides a large **Start Chest Compressions**
+button (green background). While active it changes to **Stop Chest Compressions**
+(red background). **Compression quality** can be changed at any time:
+**Good**, **Adequate** (default), **Poor**, or **Bad**.
+
+- Compressions are generated independently of the ECG at **90–110/min**, with
+ a new reproducible pseudo-random compression rate and pressure each stroke.
+ **The ECG rhythm and electrical HR setting are not changed.**
+- Every compression adds movement artifact to the ECG. In a patient with
+ **existing intrinsic arterial perfusion**, the native arterial waveform is
+ preserved but distorted by compression-synchronous pressure artifact.
+- With **no intrinsic arterial pulse** (e.g., VF, PVT, asystole or PEA),
+ each effective compression generates a broad, blunt arterial pressure wave:
+
+ | Compression quality | Compression-generated ART systolic peak |
+ | --- | --- |
+ | Good | 90 mmHg ±10% (81–99 mmHg) |
+ | Adequate (default) | 70 mmHg ±10% (63–77 mmHg) |
+ | Poor | 50 mmHg, +10% / −50% (25–55 mmHg) |
+ | Bad | No compression-generated arterial pressure; 0–5 mmHg baseline drift |
+
+ During pulseless CPR, **ART SYS** shows the current compression peak,
+ while **DIA/MAP** remain `--` (not estimable from this synthetic pressure).
+- SpO₂ numeric saturation and the pleth waveform remain visible **only when
+ compression quality is Good**, provided the sensor is connected and not
+ occluded by an NIBP cuff. Their effective signal quality is forced to
+ **Poor (★)**, irrespective of the normal Admin quality setting. The displayed
+ pleth-derived **PR follows the compression rate (90–110/min)**, not the ECG.
+ Adequate, Poor and Bad CPR display **NO READING**; detached sensors display
+ **NO SENSOR**. Compression-induced Poor quality does not schedule the usual
+ intermittent dropout; that resumes when ordinary Poor signal mode returns.
+- Existing numerical alarms and rhythm alarms remain active. ART SYS limits
+ apply to compression-generated systolic peaks; NIBP scheduling remains unchanged; its cycle duration still depends on
+ effective SpO₂ quality at the start of a measurement.
+
+These pressure targets are **didactic assumptions**, not validated CPR
+hemodynamic criteria. The exercise must not be used to judge real compression
+quality or clinical perfusion.
+
## Build and run on Fedora
```bash
diff --git a/src/alarm.rs b/src/alarm.rs
index d368f20..116b7f4 100644
--- a/src/alarm.rs
+++ b/src/alarm.rs
@@ -35,7 +35,6 @@ pub fn level(p: &Parameters, sim: &Simulator) -> AlarmLevel {
let captured = p.ecg_rhythm.can_generate_pulse()
&& p.heart_rate > 0
&& p.pulse_conduction != PulseConduction::None;
- let pr = if captured { sim.pulse_rate() } else { None };
if p.show_ecg {
if p.ecg_rhythm.rhythm_alarm().is_some() {
@@ -47,10 +46,10 @@ pub fn level(p: &Parameters, sim: &Simulator) -> AlarmLevel {
}
if p.show_spo2 {
- let status = p.spo2_status_at_quality(pr, sim.poor_signal_lost(), sim.spo2_quality(p));
+ let status = sim.spo2_status(p);
if status != Spo2Status::Available
|| outside(p.alarms.spo2, Some(p.spo2))
- || outside(p.alarms.pr, pr)
+ || outside(p.alarms.pr, sim.spo2_pulse_rate(p))
{
result = AlarmLevel::Standard;
}
diff --git a/src/model.rs b/src/model.rs
index 996d6ba..009b231 100644
--- a/src/model.rs
+++ b/src/model.rs
@@ -83,6 +83,29 @@ pub enum CapnoShape {
Obstructive,
}
+/// Instructor-selected efficacy of manual chest compressions.
+/// This affects synthetic pressure and pleth signals, not ECG rhythm or HR.
+#[derive(Clone, Copy, Debug, PartialEq, Eq)]
+pub enum ChestCompressionQuality {
+ Good,
+ Adequate,
+ Poor,
+ Bad,
+}
+
+impl ChestCompressionQuality {
+ /// Approximate compression-generated systolic peak pressure (mmHg).
+ /// None means that compressions generate no measurable arterial pressure.
+ pub fn peak_range(self) -> Option<(f64, f64)> {
+ match self {
+ Self::Good => Some((81.0, 99.0)), // 90 +/- 10%
+ Self::Adequate => Some((63.0, 77.0)), // 70 +/- 10%
+ Self::Poor => Some((25.0, 55.0)), // 50 -50% / +10%
+ Self::Bad => None,
+ }
+ }
+}
+
/// Instructor-selected plethysmography signal quality; separate from the
/// physiological oxygen-saturation setting and mechanical pulse capture.
#[derive(Clone, Copy, Debug, PartialEq, Eq)]
@@ -202,6 +225,8 @@ pub struct Parameters {
pub patient_name: String, // displayed in the monitor header, blank = generic title
pub alarms: AlarmSettings,
pub audible_alarms: bool, // mute only the sound, never the visual alarms
+ pub chest_compressions_active: bool,
+ pub chest_compression_quality: ChestCompressionQuality,
pub ecg_rhythm: EcgRhythm,
pub heart_rate: i32, // bpm, organized electrical rate; not mechanical pulse rate
pub pulse_conduction: PulseConduction,
@@ -277,6 +302,8 @@ impl Default for Parameters {
patient_name: String::new(),
alarms: AlarmSettings::default(),
audible_alarms: true,
+ chest_compressions_active: false,
+ chest_compression_quality: ChestCompressionQuality::Adequate,
ecg_rhythm: EcgRhythm::Sinus,
heart_rate: 75,
pulse_conduction: PulseConduction::OneToOne,
@@ -313,6 +340,17 @@ pub fn mean_arterial_pressure(systolic: i32, diastolic: i32) -> i32 {
mod tests {
use super::*;
+ #[test]
+ fn compression_quality_defaults_to_adequate_and_has_requested_pressure_ranges() {
+ let p = Parameters::default();
+ assert!(!p.chest_compressions_active);
+ assert_eq!(p.chest_compression_quality, ChestCompressionQuality::Adequate);
+ assert_eq!(ChestCompressionQuality::Good.peak_range(), Some((81.0, 99.0)));
+ assert_eq!(ChestCompressionQuality::Adequate.peak_range(), Some((63.0, 77.0)));
+ assert_eq!(ChestCompressionQuality::Poor.peak_range(), Some((25.0, 55.0)));
+ assert_eq!(ChestCompressionQuality::Bad.peak_range(), None);
+ }
+
#[test]
fn mean_pressure_uses_one_third_pulse_pressure() {
assert_eq!(mean_arterial_pressure(120, 75), 90);
diff --git a/src/render.rs b/src/render.rs
index 8cce43d..4053fe1 100644
--- a/src/render.rs
+++ b/src/render.rs
@@ -150,6 +150,7 @@ fn draw_nibp_box(cr: &Context, x: f64, top: f64, width: f64, height: f64,
], right, top, height * 0.65, width * 0.72);
}
+#[cfg(test)]
fn pleth_trace_enabled(p: &Parameters) -> bool {
p.spo2_sensor_attached && p.spo2_quality != Spo2Quality::None
}
@@ -160,9 +161,16 @@ fn spo2_vitals(p: &Parameters, pulse_rate: Option<i32>, signal_lost: bool)
spo2_vitals_at_quality(p, pulse_rate, signal_lost, p.spo2_quality)
}
+#[cfg(test)]
fn spo2_vitals_at_quality(p: &Parameters, pulse_rate: Option<i32>, signal_lost: bool,
quality: Spo2Quality) -> (String, String, String) {
- match p.spo2_status_at_quality(pulse_rate, signal_lost, quality) {
+ spo2_vitals_for_status(p, pulse_rate, quality,
+ p.spo2_status_at_quality(pulse_rate, signal_lost, quality))
+}
+
+fn spo2_vitals_for_status(p: &Parameters, pulse_rate: Option<i32>, quality: Spo2Quality,
+ status: Spo2Status) -> (String, String, String) {
+ match status {
Spo2Status::NoSensor => (
"SpO₂".to_owned(), "NO SENSOR".to_owned(), "PR -- bpm".to_owned()),
Spo2Status::NoReading => (
@@ -196,10 +204,11 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64,
&& p.heart_rate > 0
&& p.pulse_conduction != PulseConduction::None;
let pulse_rate = if has_capture { sim.pulse_rate() } else { None };
+ let spo2_rate = sim.spo2_pulse_rate(p);
let ecg_hr = if p.ecg_rhythm.has_qrs() && p.heart_rate > 0 {
Some(p.heart_rate)
} else { None };
- let spo2_status = p.spo2_status_at_quality(pulse_rate, sim.poor_signal_lost(), sim.spo2_quality(p));
+ let spo2_status = sim.spo2_status(p);
let oxygen = if spo2_status == Spo2Status::Available { Some(p.spo2) } else { None };
let limits: Vec<(&str, AlarmLimits)> = match ch {
@@ -228,8 +237,8 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64,
}
}
Channel::Pleth => {
- let (label, value, info) = spo2_vitals_at_quality(p, pulse_rate,
- sim.poor_signal_lost(), sim.spo2_quality(p));
+ let (label, value, info) = spo2_vitals_for_status(p, spo2_rate,
+ sim.spo2_quality(p), spo2_status);
text(cr, &label, x, top + row_h * 0.24, label_size, color, false);
let technical_alarm = spo2_status != Spo2Status::Available;
let value_size = if technical_alarm {
@@ -239,8 +248,8 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64,
width, color, technical_alarm || alarmed(p.alarms.spo2, oxygen), flash);
if oxygen.is_some() {
draw_alarm_inline(cr, x, info_y, sub_size, width, color,
- "% PR ", &pulse_rate.unwrap_or_default().to_string(), " bpm",
- alarmed(p.alarms.pr, pulse_rate), flash);
+ "% PR ", &spo2_rate.unwrap_or_default().to_string(), " bpm",
+ alarmed(p.alarms.pr, spo2_rate), flash);
} else {
text(cr, &info, x, info_y, sub_size, color, false);
}
@@ -427,9 +436,7 @@ fn draw_trace(cr: &Context, channel: Channel, color: Color,
// Disconnected or absent pleth signal: no curve, including historical pulses.
if matches!(channel, Channel::Pleth)
- && (!pleth_trace_enabled(p)
- || p.spo2_status_at_quality(sim.pulse_rate(), sim.poor_signal_lost(),
- sim.spo2_quality(p)) != Spo2Status::Available)
+ && sim.spo2_status(p) != Spo2Status::Available
{
let _ = cr.restore();
return;
diff --git a/src/simulation.rs b/src/simulation.rs
index c148a30..06fd000 100644
--- a/src/simulation.rs
+++ b/src/simulation.rs
@@ -2,7 +2,8 @@
//! A conducted QRS schedules an arterial pulse and a delayed, smoothed pleth pulse.
use std::collections::VecDeque;
-use crate::model::{ArterialShape, CapnoShape, EcgRhythm, Parameters, PulseConduction, Spo2Quality};
+use crate::model::{ArterialShape, CapnoShape, ChestCompressionQuality, EcgRhythm,
+ Parameters, PulseConduction, Spo2Quality, Spo2Status};
use crate::nibp::{CuffZone, NibpMachine, NibpReading};
const SAMPLE_STEP: f64 = 0.004; // 250 Hz; adequately samples the QRS upstroke
@@ -87,6 +88,91 @@ impl PoorSignalOutages {
}
}
+/// CPR is a separate mechanical clock, independent of intrinsic cardiac rate.
+/// Randomness is sampled once per compression, so peaks and intervals remain
+/// stable during drawing and are reproducible in tests.
+#[derive(Debug)]
+struct ChestCompressions {
+ active: bool,
+ phase: f64,
+ rate_bpm: f64,
+ peak_pressure: f64,
+ quality: ChestCompressionQuality,
+ rng: u64,
+}
+
+impl ChestCompressions {
+ fn new() -> Self {
+ Self { active: false, phase: 0.0, rate_bpm: 100.0,
+ peak_pressure: 0.0, quality: ChestCompressionQuality::Adequate,
+ rng: 0xC0FF_EE12_3456_789A }
+ }
+
+ fn random_unit(&mut self) -> f64 {
+ self.rng = self.rng.wrapping_mul(6_364_136_223_846_793_005)
+ .wrapping_add(1_442_695_040_888_963_407);
+ (self.rng >> 11) as f64 / (1_u64 << 53) as f64
+ }
+
+ fn choose_peak(&mut self) {
+ self.peak_pressure = match self.quality.peak_range() {
+ Some((low, high)) => low + (high - low) * self.random_unit(),
+ None => 0.0,
+ };
+ }
+
+ fn update(&mut self, enabled: bool, quality: ChestCompressionQuality) {
+ if !enabled {
+ self.active = false;
+ self.phase = 0.0;
+ self.peak_pressure = 0.0;
+ return;
+ }
+ if !self.active {
+ self.active = true;
+ self.phase = 0.0;
+ self.rate_bpm = 90.0 + self.random_unit() * 20.0;
+ self.quality = quality;
+ self.choose_peak();
+ } else if self.quality != quality {
+ self.quality = quality;
+ self.choose_peak();
+ }
+ self.phase += SAMPLE_STEP * self.rate_bpm / 60.0;
+ if self.phase >= 1.0 {
+ self.phase = self.phase.fract();
+ self.rate_bpm = 90.0 + self.random_unit() * 20.0;
+ self.choose_peak();
+ }
+ }
+
+ fn pressure_wave(&self) -> f64 {
+ // Rounded, broad compression crest (no narrow physiological upstroke).
+ let rise = smooth_step(self.phase / 0.22);
+ let fall = 1.0 - smooth_step((self.phase - 0.36) / 0.43);
+ (rise * fall).clamp(0.0, 1.0)
+ }
+
+ fn pleth_wave(&self) -> f64 {
+ // A delayed, deliberately weak mechanical pleth pulse.
+ let phase = (self.phase - 0.26).rem_euclid(1.0);
+ smooth_step(phase / 0.27) * (1.0 - smooth_step((phase - 0.27) / 0.62))
+ }
+
+ fn ecg_artifact(&self, time: f64) -> f64 {
+ // Compression-synchronous baseline motion and jagged contact artifact.
+ let wave = self.pressure_wave();
+ 0.56 * (wave - 0.30)
+ + 0.12 * (time * 71.0).sin() * wave
+ + 0.08 * (time * 113.0).sin() * wave
+ }
+}
+
+fn smooth_step(value: f64) -> f64 {
+ let t = value.clamp(0.0, 1.0);
+ t * t * (3.0 - 2.0 * t)
+}
+
pub struct Simulator {
samples: VecDeque<Sample>,
time: f64,
@@ -100,6 +186,7 @@ pub struct Simulator {
previous_conduction: PulseConduction,
previous_heart_rate: i32,
poor_signal_outages: PoorSignalOutages,
+ compressions: ChestCompressions,
nibp: NibpMachine,
art_hold_pressure: Option<f64>,
pending_time: f64,
@@ -120,6 +207,7 @@ impl Simulator {
previous_conduction: params.pulse_conduction,
previous_heart_rate: params.heart_rate,
poor_signal_outages: PoorSignalOutages::new(),
+ compressions: ChestCompressions::new(),
nibp: NibpMachine::new(),
art_hold_pressure: None,
pending_time: 0.0,
@@ -149,7 +237,43 @@ impl Simulator {
pub fn time(&self) -> f64 { self.time }
pub fn spo2_quality(&self, p: &Parameters) -> Spo2Quality {
- self.nibp.effective_spo2_quality(self.time, p)
+ if !p.chest_compressions_active {
+ return self.nibp.effective_spo2_quality(self.time, p);
+ }
+ if p.chest_compression_quality != ChestCompressionQuality::Good {
+ return Spo2Quality::None;
+ }
+ // During effective CPR the pleth signal is Poor regardless of Admin's
+ // baseline quality; an occlusive NIBP cuff can still suppress it.
+ if p.nibp_cuff_on_spo2 {
+ match self.nibp.cuff_zone(self.time, p) {
+ CuffZone::Occluded => return Spo2Quality::None,
+ CuffZone::Partial | CuffZone::Free => {}
+ }
+ }
+ Spo2Quality::Poor
+ }
+
+ /// Display-only pulse rate: under effective CPR the peripheral signal
+ /// follows compressions rather than non-perfusing electrical QRS events.
+ pub fn spo2_pulse_rate(&self, p: &Parameters) -> Option<i32> {
+ if p.chest_compressions_active {
+ (p.chest_compression_quality == ChestCompressionQuality::Good)
+ .then_some(self.compressions.rate_bpm.round() as i32)
+ } else {
+ self.pulse_rate()
+ }
+ }
+
+ pub fn spo2_status(&self, p: &Parameters) -> Spo2Status {
+ if !p.spo2_sensor_attached { return Spo2Status::NoSensor; }
+ if p.chest_compressions_active {
+ return if p.chest_compression_quality == ChestCompressionQuality::Good
+ && self.spo2_quality(p) != Spo2Quality::None
+ { Spo2Status::Available } else { Spo2Status::NoReading };
+ }
+ p.spo2_status_at_quality(self.pulse_rate(), self.poor_signal_lost(),
+ self.spo2_quality(p))
}
pub fn start_nibp_now(&mut self, p: &Parameters) {
@@ -161,7 +285,7 @@ impl Simulator {
if !p.spo2_sensor_attached || self.poor_signal_outages.active {
Spo2Quality::None
} else {
- p.spo2_quality
+ self.spo2_quality(p)
}
}
@@ -169,6 +293,11 @@ impl Simulator {
pub fn displayed_art_pressures(&self, p: &Parameters, has_capture: bool)
-> (Option<i32>, Option<i32>, Option<i32>) {
if !has_capture {
+ // During pulseless CPR the upper ART number reflects the peak
+ // compression pressure; DIA/MAP remain intentionally unassessed.
+ if self.compressions.active && p.chest_compression_quality != ChestCompressionQuality::Bad {
+ return (Some(self.compressions.peak_pressure.round() as i32), None, None);
+ }
return (self.measured_art_pressure(), None, None);
}
if p.nibp_cuff_on_art {
@@ -219,8 +348,11 @@ impl Simulator {
fn step(&mut self, params: &Parameters) {
self.time += SAMPLE_STEP;
+ self.compressions.update(params.chest_compressions_active,
+ params.chest_compression_quality);
self.poor_signal_outages.update(self.time,
- params.spo2_quality == Spo2Quality::Poor && params.spo2_sensor_attached);
+ !params.chest_compressions_active && params.spo2_quality == Spo2Quality::Poor
+ && params.spo2_sensor_attached);
// Snapshot the unoccluded sensor quality at the start of a cuff cycle.
// Cuff-induced signal loss during that cycle must not change its duration.
let start_quality = self.nibp_start_quality(params);
@@ -289,8 +421,25 @@ impl Simulator {
self.rate_qrs.pop_front();
}
- let ecg = ecg_amplitude(self.ecg_phase, self.time, params.ecg_rhythm, params.heart_rate);
- let (normal_art, pleth_target) = self.mechanical_signals(params);
+ let mut ecg = ecg_amplitude(self.ecg_phase, self.time, params.ecg_rhythm, params.heart_rate);
+ let (mut normal_art, mut pleth_target) = self.mechanical_signals(params);
+ if self.compressions.active {
+ ecg += self.compressions.ecg_artifact(self.time);
+ let perfusing = params.ecg_rhythm.can_generate_pulse()
+ && params.pulse_conduction != PulseConduction::None && params.heart_rate > 0;
+ let wave = self.compressions.pressure_wave();
+ if perfusing {
+ // Preserve the patient's intrinsic pressure, with superimposed
+ // compression-synchronous artifact even during bad CPR.
+ normal_art = (normal_art + 22.0 * (wave - 0.32)).clamp(0.0, 250.0);
+ } else if self.compressions.peak_pressure > 0.0 {
+ let baseline = pulseless_arterial_drift(self.time);
+ normal_art = baseline + (self.compressions.peak_pressure - baseline) * wave;
+ }
+ pleth_target = if params.chest_compression_quality == ChestCompressionQuality::Good {
+ 0.85 * self.compressions.pleth_wave()
+ } else { 0.0 };
+ }
let art = self.art_with_cuff(normal_art, params);
let smoothing = 1.0 - (-SAMPLE_STEP / PLETH_FILTER_TAU).exp();
self.filtered_pleth += smoothing * (pleth_target - self.filtered_pleth);
@@ -301,9 +450,7 @@ impl Simulator {
};
let pleth_quality = self.spo2_quality(params);
- let pleth_valid = params.spo2_sensor_attached
- && pleth_quality != Spo2Quality::None
- && !self.poor_signal_outages.active;
+ let pleth_valid = self.spo2_status(params) == Spo2Status::Available;
self.samples.push_back(Sample {
time: self.time, ecg, pleth, pleth_valid, pleth_quality, art, co2,
});
@@ -313,9 +460,10 @@ impl Simulator {
}
fn art_with_cuff(&mut self, normal_art: f64, params: &Parameters) -> f64 {
- if !params.nibp_cuff_on_art || !params.ecg_rhythm.can_generate_pulse()
- || params.pulse_conduction == PulseConduction::None || params.heart_rate <= 0
- {
+ let native_pulse = params.ecg_rhythm.can_generate_pulse()
+ && params.pulse_conduction != PulseConduction::None && params.heart_rate > 0;
+ let compression_pulse = self.compressions.active && self.compressions.peak_pressure > 0.0;
+ if !params.nibp_cuff_on_art || !(native_pulse || compression_pulse) {
self.art_hold_pressure = None;
return normal_art;
}
@@ -545,6 +693,129 @@ mod tests {
sim
}
+ #[test]
+ fn compression_rate_varies_only_between_90_and_110_bpm() {
+ let mut cpr = ChestCompressions::new();
+ let mut observed = Vec::new();
+ for _ in 0..(25.0 / SAMPLE_STEP) as usize {
+ let previous = cpr.phase;
+ cpr.update(true, ChestCompressionQuality::Good);
+ assert!((90.0..=110.0).contains(&cpr.rate_bpm));
+ if cpr.phase < previous { observed.push(cpr.rate_bpm); }
+ }
+ assert!(observed.len() >= 30);
+ assert!(observed.iter().any(|rate| (rate - observed[0]).abs() > 1.0));
+ cpr.update(false, ChestCompressionQuality::Good);
+ assert!(!cpr.active);
+ assert_eq!(cpr.peak_pressure, 0.0);
+ }
+
+ #[test]
+ fn compressions_generate_requested_pulseless_arterial_pressure_by_quality() {
+ for (quality, limits) in [
+ (ChestCompressionQuality::Good, Some((81.0, 99.0))),
+ (ChestCompressionQuality::Adequate, Some((63.0, 77.0))),
+ (ChestCompressionQuality::Poor, Some((25.0, 55.0))),
+ (ChestCompressionQuality::Bad, None),
+ ] {
+ let p = Parameters { ecg_rhythm: EcgRhythm::VentricularFibrillation,
+ chest_compressions_active: true, chest_compression_quality: quality,
+ ..Parameters::default() };
+ let mut sim = Simulator::new(&p);
+ for _ in 0..(2.0 / SAMPLE_STEP) as usize { sim.step(&p); }
+ assert_eq!(sim.pulse_rate(), None, "no intrinsic QRS pulse in VF");
+ let recent: Vec<_> = sim.samples.iter().rev().take(500).collect();
+ let peak = recent.iter().map(|s| s.art).fold(f64::NEG_INFINITY, f64::max);
+ let (sys, dia, map) = sim.displayed_art_pressures(&p, false);
+ assert_eq!((dia, map), (None, None));
+ if let Some((low, high)) = limits {
+ assert!(peak >= low - 1.0 && peak <= high + 1.0,
+ "{quality:?}: waveform peak {peak}");
+ assert!(sys.is_some_and(|v| (low - 1.0..=high + 1.0).contains(&f64::from(v))));
+ } else {
+ assert!(peak <= 5.0, "bad CPR must not create a pulse");
+ assert!(sys.is_some_and(|v| (0..=5).contains(&v)));
+ }
+ }
+ }
+
+ #[test]
+ fn good_cpr_can_create_poor_pleth_in_vf_despite_admin_no_quality() {
+ let p = Parameters { ecg_rhythm: EcgRhythm::VentricularFibrillation,
+ spo2_quality: Spo2Quality::None,
+ chest_compressions_active: true,
+ chest_compression_quality: ChestCompressionQuality::Good,
+ ..Parameters::default() };
+ let mut sim = Simulator::new(&p);
+ for _ in 0..400 { sim.step(&p); }
+ assert_eq!(sim.spo2_quality(&p), Spo2Quality::Poor);
+ assert_eq!(sim.spo2_status(&p), Spo2Status::Available);
+ assert!(sim.spo2_pulse_rate(&p).is_some_and(|v| (90..=110).contains(&v)));
+ assert!(sim.samples.iter().rev().take(400).any(|s| s.pleth > 0.05 && s.pleth_valid));
+ assert!(sim.samples.iter().rev().take(400).all(|s| s.pleth_quality == Spo2Quality::Poor));
+ }
+
+ #[test]
+ fn only_good_cpr_shows_pleth_and_sensor_disconnect_takes_precedence() {
+ for quality in [ChestCompressionQuality::Adequate,
+ ChestCompressionQuality::Poor, ChestCompressionQuality::Bad] {
+ let p = Parameters { chest_compressions_active: true,
+ chest_compression_quality: quality, ..Parameters::default() };
+ let mut sim = Simulator::new(&p);
+ sim.step(&p);
+ assert_eq!(sim.spo2_status(&p), Spo2Status::NoReading);
+ assert_eq!(sim.spo2_pulse_rate(&p), None);
+ assert!(!sim.samples.back().unwrap().pleth_valid);
+ }
+ let mut p = Parameters { chest_compressions_active: true,
+ chest_compression_quality: ChestCompressionQuality::Good, ..Parameters::default() };
+ let mut sim = Simulator::new(&p);
+ p.spo2_sensor_attached = false;
+ sim.step(&p);
+ assert_eq!(sim.spo2_status(&p), Spo2Status::NoSensor);
+ assert!(!sim.samples.back().unwrap().pleth_valid);
+ }
+
+ #[test]
+ fn compressions_distort_ecg_and_preserve_intrinsic_pulses_in_sinus() {
+ let normal = Parameters::default();
+ let with_cpr = Parameters { chest_compressions_active: true,
+ chest_compression_quality: ChestCompressionQuality::Adequate,
+ ..Parameters::default() };
+ let mut base = Simulator::new(&normal);
+ let mut cpr = Simulator::new(&with_cpr);
+ let mut ecg_distortion = false;
+ let mut art_distortion = false;
+ for _ in 0..500 {
+ base.step(&normal);
+ cpr.step(&with_cpr);
+ let native = base.samples.back().unwrap();
+ let compressed = cpr.samples.back().unwrap();
+ ecg_distortion |= (compressed.ecg - native.ecg).abs() > 0.1;
+ art_distortion |= (compressed.art - native.art).abs() > 5.0;
+ }
+ assert!(ecg_distortion);
+ assert!(art_distortion);
+ assert!(cpr.samples.iter().rev().take(500).any(|s| s.art > 60.0));
+ assert_eq!(cpr.pulse_rate(), Some(75), "CPR must not change underlying HR/PR capture");
+ }
+
+ #[test]
+ fn stopping_compressions_restores_pulseless_drift_and_normal_pleth_rules() {
+ let mut p = Parameters { ecg_rhythm: EcgRhythm::Asystole,
+ chest_compressions_active: true,
+ chest_compression_quality: ChestCompressionQuality::Good,
+ ..Parameters::default() };
+ let mut sim = Simulator::new(&p);
+ assert_eq!(sim.spo2_status(&p), Spo2Status::Available);
+ p.chest_compressions_active = false;
+ sim.step(&p);
+ assert!((0.0..=5.0).contains(&sim.samples.back().unwrap().art));
+ assert_eq!(sim.spo2_status(&p), Spo2Status::NoReading);
+ assert!(!sim.samples.back().unwrap().pleth_valid);
+ assert_eq!(sim.spo2_pulse_rate(&p), None);
+ }
+
#[test]
fn signals_remain_in_expected_ranges() {
let p = Parameters::default();
diff --git a/src/ui.rs b/src/ui.rs
index 7e6fd0a..ffb8579 100644
--- a/src/ui.rs
+++ b/src/ui.rs
@@ -9,7 +9,8 @@ use gtk::prelude::*;
use gtk::{Application, ApplicationWindow, Orientation};
use crate::alarm::{self, AlarmAudio};
-use crate::model::{AlarmLimits, AlarmSettings, ArterialShape, CapnoShape, EcgRhythm, Parameters, PulseConduction, Spo2Quality};
+use crate::model::{AlarmLimits, AlarmSettings, ArterialShape, CapnoShape,
+ ChestCompressionQuality, EcgRhythm, Parameters, PulseConduction, Spo2Quality};
use crate::render;
use crate::simulation::Simulator;
@@ -186,6 +187,60 @@ fn create_admin(app: &Application, params: SharedParams,
patient_row.append(&name_entry);
patient.append(&patient_row);
+ // Resuscitation controls are deliberately near the top of the Admin panel.
+ // CSS sets the *button background*, not just its text color.
+ if let Some(display) = gdk::Display::default() {
+ let provider = gtk::CssProvider::new();
+ provider.load_from_data(
+ "button.cpr-start { background-image: none; background-color: #158742; color: #ffffff; font-weight: bold; }
+ button.cpr-stop { background-image: none; background-color: #c53035; color: #ffffff; font-weight: bold; }"
+ );
+ gtk::style_context_add_provider_for_display(
+ &display, &provider, gtk::STYLE_PROVIDER_PRIORITY_APPLICATION);
+ }
+ let cpr = group(&controls, "Chest compressions", None);
+ let compression_button = gtk::Button::with_label("Start Chest Compressions");
+ compression_button.set_hexpand(true);
+ compression_button.add_css_class("cpr-start");
+ compression_button.connect_clicked({
+ let params = params.clone();
+ move |button| {
+ let mut p = params.borrow_mut();
+ p.chest_compressions_active = !p.chest_compressions_active;
+ if p.chest_compressions_active {
+ button.set_label("Stop Chest Compressions");
+ button.remove_css_class("cpr-start");
+ button.add_css_class("cpr-stop");
+ } else {
+ button.set_label("Start Chest Compressions");
+ button.remove_css_class("cpr-stop");
+ button.add_css_class("cpr-start");
+ }
+ }
+ });
+ cpr.append(&compression_button);
+ let _quality = add_dropdown_at(&cpr, "Compression quality",
+ &["Good", "Adequate", "Poor", "Bad"], 1, params.clone(), |p, selected| {
+ p.chest_compression_quality = match selected {
+ 0 => ChestCompressionQuality::Good,
+ 2 => ChestCompressionQuality::Poor,
+ 3 => ChestCompressionQuality::Bad,
+ _ => ChestCompressionQuality::Adequate,
+ };
+ });
+ let cpr_hint = gtk::Label::new(Some(
+ "CPR: 90–110 compressions/min. ECG is distorted; ART receives compression waves. "
+ ));
+ cpr_hint.set_xalign(0.0);
+ cpr_hint.set_wrap(true);
+ cpr.append(&cpr_hint);
+ let cpr_hint2 = gtk::Label::new(Some(
+ "Only Good compressions generate a Poor-quality SpO₂/pleth signal (if the sensor is attached)."
+ ));
+ cpr_hint2.set_xalign(0.0);
+ cpr_hint2.set_wrap(true);
+ cpr.append(&cpr_hint2);
+
let ecg = group(&controls, "ECG", Some(ECG_GREEN));
add_visibility(&ecg, params.borrow().show_ecg, params.clone(), |p, show| p.show_ecg = show);
let rhythm_dropdown = add_dropdown_at(&ecg, "ECG rhythm", &[