--- a/Cargo.toml
+++ b/Cargo.toml
@@ -1,6 +1,6 @@
[package]
name = "patient-monitor-simulation"
-version = "0.6.3"
+version = "0.6.4"
edition = "2021"
license = "MIT"
description = "Synthetic patient-monitor simulation for teaching (not for clinical use)"
--- a/README.de.md
+++ b/README.de.md
@@ -1,4 +1,4 @@
-# Patient Monitor Simulation (PaMSim) — v0.6.3
+# Patient Monitor Simulation (PaMSim) — v0.6.4
Ein mit Rust und GTK4 entwickelter Patient*innenmonitor-Simulator mit zwei Fenstern für die Lehre unter Fedora Linux.
@@ -26,7 +26,7 @@
Beim Ausblenden anderer Parameter werden die verbleibenden Kurvenzeilen wie
bisher dynamisch verteilt.
-## Touch-Bedienung am Monitor: ausschließlich Alarmgrenzen (v0.6.1)
+## Touch-Bedienung am Monitor: Alarmgrenzen und NIBP-Funktionen (v0.6.4)
Durch Berühren oder Anklicken der **Kurve oder des numerischen Wertefeldes**
von EKG, SpO₂, ART oder CO₂ öffnet sich das entsprechende Alarmmenü. Bei
@@ -36,7 +36,7 @@
Hintergrund, sehr hellgraue Schrift sowie 0,8 Pixel breite Begrenzungs-
und Trennlinien** wie der Hauptmonitor.
-**Am Monitor können ausschließlich Alarmgrenzen eingestellt werden.**
+**In allen Monitor-Menüs können die Alarmgrenzen eingestellt werden.**
Für jede untere und obere Alarmgrenze stehen große **−/+**-Tasten sowie
separate **ON/OFF**-Tasten zur Verfügung. Nicht gesetzte Grenzwerte sind
deaktiviert. Ein unterer Grenzwert darf den oberen nicht überschreiten.
@@ -55,18 +55,20 @@
**Cancel** oder **Esc** werden nicht übernommene Änderungen verworfen.
Die Auswahl der EKG-Ableitung, SpO₂-Signalqualität und Sensorverbindung,
-der arteriellen Kurvenform, der Kapnogrammform sowie **sämtliche NIBP-
-Messfunktionen** sind ausschließlich im **Admin-Fenster** verfügbar. Dazu
-zählen Messintervall, automatische Messung, **Measure now**, simulierter
-Messausfall und Manschettenlokalisation. Diese Parameter können über die
-Alarmmenüs am Monitor nicht verändert werden.
+der arteriellen Kurvenform und der Kapnogrammform bleiben ausschließlich im
+**Admin-Fenster**. Das **NIBP-Touchmenü** bietet zusätzlich **Measure now**,
+**Automatic measurement ON/OFF** und **Measurement interval** (1, 3, 5, 10,
+20, 30 oder 60 Minuten). Intervall und Automatik werden erst mit **Apply**
+übernommen; **Measure now** startet dagegen sofort, auch bei deaktivierter
+Automatik. Eine bereits laufende Messung wird nicht erneut gestartet.
+Simulierter Messausfall und Manschettenlokalisation bleiben Admin-only.
### NIBP beim Programmstart
Die **automatische NIBP-Messung ist beim Start ausgeschaltet**. Anfangs
zeigt der Monitor `---/---` (MAP `---`); es findet keine Messung statt.
-Die erste Messung wird über **Measure now** im Admin-Fenster oder durch
-Aktivieren von **Automatic NIBP measurement** ausgelöst. Beim Einschalten
+Die erste Messung wird über **Measure now** im NIBP-Touchmenü oder Admin-Fenster
+oder durch Aktivieren von **Automatic NIBP measurement** ausgelöst. Beim Einschalten
von Auto beginnt sofort ein Messzyklus; das Intervall zählt anschließend
jeweils ab Ende der vorherigen Messung. Beim Ausschalten von Auto wird
eine bereits laufende Messung nicht abgebrochen. **Measure now** funktioniert
@@ -83,8 +85,8 @@
Deaktivieren liegt unmittelbar rechts von Minus. Größe, Gestaltung,
Schrittweite, Wiederherstellung des letzten Werts sowie Apply/Cancel
bleiben erhalten. Bei Platzmangel lässt sich die Matrix scrollen, während
-Apply und Cancel zugänglich bleiben. Andere Einstellungen bleiben dem
-Admin-Fenster vorbehalten.
+Apply und Cancel zugänglich bleiben. Andere Einstellungen bleiben dem Admin-Fenster vorbehalten, mit Ausnahme der
+expliziten NIBP-Messfunktionen im Touchmenü.
## Thoraxkompressionen (v0.5.4)
@@ -607,3 +609,13 @@
Kurvenformen sowie NIBP-Messfunktionen wurden aus den Monitor-Menüs entfernt
und bleiben im Admin-Fenster verfügbar. Die Simulationslogik, Alarmprüfung
und das NIBP-Startverhalten wurden nicht verändert.
+
+### v0.6.4 – NIBP-Touchbedienung wiederhergestellt
+
+Das NIBP-Menü enthält wieder **Measure now**, **Automatic measurement ON/OFF**
+und das **Messintervall** (1, 3, 5, 10, 20, 30 oder 60 Minuten) oberhalb der
+SYS/MAP/DIA-Alarmmatrix. Die Einstellungen für Intervall und Automatik werden
+mit **Apply** gespeichert; **Measure now** startet unmittelbar einen Messzyklus,
+auch wenn die Automatik ausgeschaltet ist. Die Admin-Oberfläche wird
+synchronisiert. Die anderen Parametermenüs bleiben auf Alarmgrenzen beschränkt.
+Manschettenzuordnung und simulierter Messausfall verbleiben im Admin-Fenster.
--- a/README.md
+++ b/README.md
@@ -1,4 +1,4 @@
-# Patient Monitor Simulation (PaMSim) — v0.6.3
+# Patient Monitor Simulation (PaMSim) — v0.6.4
A Rust/GTK4 patient-monitor simulator with two main windows for teaching on Fedora Linux.
@@ -23,7 +23,7 @@
bottom measurement row and other three groups remain present. Disabling one
of the four waveform channels still reflows the remaining rows above it.
-## Monitor touchscreen: alarm limits only (v0.6.1)
+## Monitor touchscreen: alarm limits and NIBP controls (v0.6.4)
Tap or click the **waveform or numerical readout** of ECG, SpO₂, ART or CO₂
to open that channel's alarm-limit panel. For NIBP, tap the **rightmost
@@ -32,7 +32,7 @@
are available in fullscreen and retain a **black background, very light-grey
text, and 0.8-pixel borders and dividers**, in the style of the main monitor.
-**Only alarm thresholds can be modified from the monitor-side menus.**
+**Alarm thresholds can be modified from every monitor-side menu.**
No keyboard is required: every lower/upper limit has large **− / +** controls
with a parameter-specific increment and an independent **ON/OFF** control.
Unset limits remain disabled. The lower limit cannot exceed the upper limit.
@@ -49,18 +49,20 @@
Changing a threshold sets the alarm preset to **Custom**. **Cancel** or
**Esc** discards the draft changes.
-ECG lead selection, SpO₂ signal quality and sensor status, ART waveform shape,
-capnogram shape, and all NIBP measurement controls are **Admin-only**. This
-includes NIBP measurement interval, Auto ON/OFF, **Measure now**, simulated
-failed reading, and cuff placement. None of these physiological or technical
-parameters is changed by the monitor-side alarm menus.
+**NIBP is the exception:** its monitor-side menu additionally provides **Measure now**,
+**Automatic measurement ON/OFF**, and the **1/3/5/10/20/30/60-minute interval**.
+Interval and Auto changes take effect with **Apply** (or are discarded with
+Cancel/Esc); **Measure now starts immediately**, even with Auto OFF and before
+Apply. The touch controls synchronize with Admin. A measurement already in
+progress is not restarted. The simulated failure option and cuff placement
+remain Admin-only, as do ECG lead, SpO₂ sensor/quality and waveform choices.
### NIBP startup and automatic measurements
**Auto measurement is OFF by default.** On startup the monitor shows
`---/---` (MAP `---`) and no measurement is initiated. To obtain a reading,
-select **Measure now** in Admin, or enable **Automatic NIBP measurement**
-there. The first automatic cycle begins immediately after enabling Auto;
+select **Measure now** in the NIBP monitor menu (or in Admin), or enable
+**Automatic NIBP measurement** via the menu (or Admin). The first automatic cycle begins immediately after enabling Auto;
subsequent measurement intervals count from completion of the prior cycle.
Disabling Auto stops further scheduled measurements without interrupting a
cycle already in progress. Manual measurement remains possible while Auto
@@ -77,7 +79,8 @@
large button styling, per-parameter increments, last-value restoration,
optional bounds and Apply/Cancel semantics are unchanged. The matrix scrolls
if necessary while Apply and Cancel remain accessible below it. Other
-physiological and NIBP controls remain Admin-only.
+physiological controls remain Admin-only, except for the three explicitly
+requested NIBP measurement controls.
## Chest compressions (v0.5.4)
@@ -620,3 +623,14 @@
measurement controls from monitor-side menus. These remain available in
Admin, including manual NIBP measurement and Auto ON/OFF. No physiological
model, alarm evaluation or NIBP startup behavior was changed.
+
+### v0.6.4 — NIBP touch controls restored
+
+The monitor-side NIBP settings menu again contains **Measure now**,
+**Automatic measurement ON/OFF** and the **measurement interval** (1, 3, 5,
+10, 20, 30, 60 minutes). These controls are above the horizontal SYS/MAP/DIA
+alarm matrix and share its monochrome touchscreen styling. Auto and interval
+are saved with Apply; Measure now starts a cuff cycle immediately regardless
+of Auto. Both monitor and Admin display the selected settings. Other monitor
+menus remain limited to alarm thresholds; NIBP cuff placement, the simulated
+failed-reading option and non-NIBP signal settings remain Admin-only.
--- a/src/simulation.rs
+++ b/src/simulation.rs
@@ -277,6 +277,10 @@
}
p.spo2_status_at_quality(self.pulse_rate(), self.poor_signal_lost(),
self.spo2_quality(p))
+ }
+
+ pub fn nibp_measuring(&self) -> bool {
+ self.nibp.measuring()
}
pub fn start_nibp_now(&mut self, p: &Parameters) {
--- a/src/ui.rs
+++ b/src/ui.rs
@@ -108,8 +108,8 @@
});
window.add_controller(keys);
- // One gesture opens alarm-only panels for visible waveform/numeric rows
- // and NIBP's bottom-right cell. Mouse and Wayland touch share geometry.
+ // Mouse and Wayland touch open the visible module's settings panel.
+ // NIBP alone also includes its explicitly requested measurement controls.
let monitor_menu: MonitorMenuHandle = Rc::new(RefCell::new(None));
let click = gtk::GestureClick::new();
click.connect_released({
@@ -117,13 +117,14 @@
let window = window.clone();
let canvas = canvas.clone();
let params = params.clone();
+ let simulator = simulator.clone();
move |_gesture, _press_count, x, y| {
let touched = {
let p = params.borrow();
render::monitor_hit_test(x, y, canvas.width(), canvas.height(), &p)
};
if let Some(channel) = touched {
- open_module_menu(&app, &window, params.clone(),
+ open_module_menu(&app, &window, params.clone(), simulator.clone(),
admin_changed.clone(), monitor_menu.clone(), channel);
}
}
@@ -133,11 +134,25 @@
window
}
-/// Map an Admin NIBP measurement interval to its dropdown selection.
-/// The touchscreen alarm menus do not expose scheduling controls.
+/// Both Admin and the monitor NIBP menu use the same interval options.
+const NIBP_INTERVALS: [i32; 7] = [1, 3, 5, 10, 20, 30, 60];
+
fn nibp_interval_index(minutes: i32) -> u32 {
- const INTERVALS: [i32; 7] = [1, 3, 5, 10, 20, 30, 60];
- INTERVALS.iter().position(|&value| value == minutes).unwrap_or(2) as u32
+ NIBP_INTERVALS.iter().position(|&value| value == minutes).unwrap_or(2) as u32
+}
+
+fn nibp_interval_minutes(selected: u32) -> i32 {
+ NIBP_INTERVALS.get(selected as usize).copied().unwrap_or(5)
+}
+
+/// Apply only the explicitly requested monitor-side NIBP measurement settings.
+/// Neither cuff settings nor any other module's configuration is changed.
+fn apply_nibp_measurement_settings(p: &mut Parameters, selected: u32, auto: bool) -> bool {
+ let minutes = nibp_interval_minutes(selected);
+ let changed = p.nibp_interval_minutes != minutes || p.nibp_auto_measurement != auto;
+ p.nibp_interval_minutes = minutes;
+ p.nibp_auto_measurement = auto;
+ changed
}
fn create_admin(app: &Application, params: SharedParams,
@@ -437,10 +452,9 @@
let nibp_interval_dropdown = add_dropdown_at(&nibp, "Measurement interval",
&["1 min", "3 min", "5 min", "10 min", "20 min", "30 min", "60 min"],
- 2, params.clone(), |p, selected| {
- p.nibp_interval_minutes = match selected {
- 0 => 1, 1 => 3, 2 => 5, 3 => 10, 4 => 20, 5 => 30, _ => 60,
- };
+ nibp_interval_index(params.borrow().nibp_interval_minutes),
+ params.clone(), |p, selected| {
+ p.nibp_interval_minutes = nibp_interval_minutes(selected);
});
let nibp_auto = gtk::CheckButton::with_label("Automatic NIBP measurement");
nibp_auto.set_active(params.borrow().nibp_auto_measurement);
@@ -602,6 +616,10 @@
min-height: 48px; min-width: 52px;
}
window.ecg-settings button:hover { background-color: #303437; }
+ window.ecg-settings dropdown {
+ color: #e5e9eb; background-color: #171717;
+ border: 1px solid #6b757d; min-height: 48px;
+ }
window.ecg-settings button.ecg-apply {
color: #000000; background-color: #e5e9eb; font-weight: bold;
}
@@ -866,8 +884,85 @@
frame
}
-/// A monitor-side menu may change only alarm limits. All patient and
-/// measurement configuration (including NIBP scheduling) stays Admin-only.
+/// Add the three explicitly requested NIBP actions to the monitor menu.
+/// Alarm limits, interval and Auto are staged until Apply. "Measure now" is
+/// an immediate command, independent of Auto and of the staged settings.
+fn nibp_touch_measurement_controls(
+ current: &Parameters,
+ params: SharedParams,
+ simulator: Rc<RefCell<Simulator>>,
+) -> (gtk::Box, gtk::DropDown, gtk::ToggleButton) {
+ let section = gtk::Box::new(Orientation::Vertical, 12);
+ section.add_css_class("alarm-limit-frame");
+ section.set_hexpand(true);
+
+ let heading = gtk::Label::new(Some("NIBP measurement"));
+ heading.add_css_class("alarm-limit-heading");
+ heading.set_xalign(0.0);
+ section.append(&heading);
+
+ let row = gtk::Box::new(Orientation::Horizontal, 12);
+ let label = gtk::Label::new(Some("Measurement interval"));
+ label.set_hexpand(true);
+ label.set_xalign(0.0);
+ let interval = gtk::DropDown::from_strings(&[
+ "1 min", "3 min", "5 min", "10 min", "20 min", "30 min", "60 min",
+ ]);
+ interval.set_selected(nibp_interval_index(current.nibp_interval_minutes));
+ interval.set_size_request(160, 52);
+ row.append(&label);
+ row.append(&interval);
+ section.append(&row);
+
+ let action_row = gtk::Box::new(Orientation::Horizontal, 12);
+ action_row.set_homogeneous(true);
+ let auto = gtk::ToggleButton::new();
+ auto.set_active(current.nibp_auto_measurement);
+ auto.set_label(if auto.is_active() {
+ "Automatic measurement: ON"
+ } else {
+ "Automatic measurement: OFF"
+ });
+ auto.connect_toggled(|button| {
+ button.set_label(if button.is_active() {
+ "Automatic measurement: ON"
+ } else {
+ "Automatic measurement: OFF"
+ });
+ });
+ action_row.append(&auto);
+
+ let measure_now = gtk::Button::with_label("Measure now");
+ measure_now.set_tooltip_text(Some("Start an NIBP cuff measurement immediately"));
+ action_row.append(&measure_now);
+ section.append(&action_row);
+
+ let feedback = gtk::Label::new(Some(
+ "Measure now acts immediately. Interval and Auto are saved with Apply."
+ ));
+ feedback.set_xalign(0.0);
+ feedback.set_wrap(true);
+ measure_now.connect_clicked({
+ let feedback = feedback.clone();
+ move |_| {
+ // Drop the immutable Ref before borrowing the simulator mutably.
+ let measuring = { simulator.borrow().nibp_measuring() };
+ if measuring {
+ feedback.set_text("NIBP measurement already in progress.");
+ } else {
+ simulator.borrow_mut().start_nibp_now(&params.borrow());
+ feedback.set_text("NIBP measurement started.");
+ }
+ }
+ });
+ // Keep the explanatory label visible while the button changes its status.
+ // It is owned by the section, not by the button callback.
+ section.append(&feedback);
+ (section, interval, auto)
+}
+
+/// All monitor modules can edit alarm limits. Only NIBP additionally offers
+/// the explicitly requested interval, Auto and immediate measurement controls.
fn apply_module_alarm_changes(
p: &mut Parameters,
limits: &[(fn(&mut AlarmSettings, AlarmLimits), AlarmLimits)],
@@ -879,12 +974,13 @@
p.alarms != previous
}
-/// Open a modal alarm-limit panel with the same black, grey, 0.8 px divider
-/// and border design as the ECG panel. Other parameters are Admin-only.
+/// Open a modal monitor settings panel in neutral black/grey styling.
+/// All modules edit alarm limits; NIBP also retains its explicit controls.
#[allow(clippy::too_many_arguments)]
fn open_module_menu(app: &Application, monitor: &ApplicationWindow,
- params: SharedParams, on_change: AdminChanged,
- open_menu: MonitorMenuHandle, channel: render::TouchChannel) {
+ params: SharedParams, simulator: Rc<RefCell<Simulator>>,
+ on_change: AdminChanged, open_menu: MonitorMenuHandle,
+ channel: render::TouchChannel) {
if let Some(existing) = open_menu.borrow().as_ref().and_then(|weak| weak.upgrade()) {
existing.present();
return;
@@ -906,7 +1002,7 @@
.default_width(800)
.default_height(match channel {
render::TouchChannel::Art => 560,
- render::TouchChannel::Nibp => 490,
+ render::TouchChannel::Nibp => 640,
render::TouchChannel::Ecg => 310,
_ => 420,
})
@@ -937,6 +1033,18 @@
heading.add_css_class("title-2");
inner.append(&heading);
inner.append(&ecg_menu_divider());
+
+ // NIBP is the explicit exception to the alarm-only monitor menu policy.
+ // Put the manual measurement action above the limit matrix for easy access.
+ let nibp_controls = if channel == render::TouchChannel::Nibp {
+ let (section, interval, auto) = nibp_touch_measurement_controls(
+ &current, params.clone(), simulator);
+ inner.append(&section);
+ inner.append(&ecg_menu_divider());
+ Some((interval, auto))
+ } else {
+ None
+ };
// A shared horizontal matrix is used in every monitor-side touch menu.
let specs = module_alarm_specs(channel, &current);
@@ -983,7 +1091,12 @@
}
let changed_alarms = {
let mut p = params.borrow_mut();
- apply_module_alarm_changes(&mut p, &selected_limits)
+ let changed = apply_module_alarm_changes(&mut p, &selected_limits);
+ if let Some((interval, auto)) = &nibp_controls {
+ apply_nibp_measurement_settings(&mut p,
+ interval.selected(), auto.is_active());
+ }
+ changed
};
if let Some(callback) = on_change.borrow().as_ref() {
callback(changed_alarms);
@@ -1064,7 +1177,7 @@
}
#[test]
- fn touchscreen_applies_only_alarm_limits_and_preserves_other_controls() {
+ fn monitor_alarm_edits_preserve_other_controls() {
let mut p = Parameters::default();
p.ecg_lead = EcgLead::V1;
p.spo2_quality = Spo2Quality::Poor;
@@ -1093,6 +1206,40 @@
assert!(p.nibp_cuff_on_art);
}
+ #[test]
+ fn nibp_touch_interval_roundtrip_and_startup_off() {
+ let p = Parameters::default();
+ assert!(!p.nibp_auto_measurement);
+ assert_eq!(p.nibp_interval_minutes, 5);
+ for (index, minutes) in NIBP_INTERVALS.into_iter().enumerate() {
+ assert_eq!(nibp_interval_index(minutes), index as u32);
+ assert_eq!(nibp_interval_minutes(index as u32), minutes);
+ }
+ assert_eq!(nibp_interval_minutes(99), 5);
+ }
+
+ #[test]
+ fn nibp_touch_apply_changes_only_interval_and_auto() {
+ let mut p = Parameters::default();
+ p.nibp_no_reading = true;
+ p.nibp_cuff_on_spo2 = true;
+ p.nibp_cuff_on_art = true;
+ p.show_nibp = false;
+ p.alarms.nibp_sys.lower = Some(80);
+ assert!(apply_nibp_measurement_settings(&mut p, 5, true));
+ assert_eq!(p.nibp_interval_minutes, 30);
+ assert!(p.nibp_auto_measurement);
+ assert!(!apply_nibp_measurement_settings(&mut p, 5, true));
+ assert!(apply_nibp_measurement_settings(&mut p, 0, false));
+ assert_eq!(p.nibp_interval_minutes, 1);
+ assert!(!p.nibp_auto_measurement);
+ assert!(p.nibp_no_reading);
+ assert!(p.nibp_cuff_on_spo2);
+ assert!(p.nibp_cuff_on_art);
+ assert!(!p.show_nibp);
+ assert_eq!(p.alarms.nibp_sys.lower, Some(80));
+ }
+
}
/// Frame a parameter section with an optional monitor-colored left sidebar.