diff --git a/Cargo.toml b/Cargo.toml
|
||
index 46b979b..8087e1c 100644
|
||
--- a/Cargo.toml
|
||
+++ b/Cargo.toml
|
||
@@ -1,6 +1,6 @@
|
||
[package]
|
||
name = "patient-monitor-simulation"
|
||
-version = "0.6.4"
|
||
+version = "0.6.5"
|
||
edition = "2021"
|
||
license = "MIT"
|
||
description = "Synthetic patient-monitor simulation for teaching (not for clinical use)"
|
||
diff --git a/README.de.md b/README.de.md
|
||
index d9f1101..3a42b91 100644
|
||
--- a/README.de.md
|
||
+++ b/README.de.md
|
||
@@ -1,4 +1,4 @@
|
||
-# Patient Monitor Simulation (PaMSim) — v0.6.4
|
||
+# Patient Monitor Simulation (PaMSim) — v0.6.5
|
||
|
||
Ein mit Rust und GTK4 entwickelter Patient*innenmonitor-Simulator mit zwei Fenstern für die Lehre unter Fedora Linux.
|
||
|
||
@@ -175,7 +175,7 @@ Mit **F11** wird der Vollbildmodus aktiviert bzw. umgeschaltet, mit **Esc** wird
|
||
Unter Wayland sollte das Fenster vor dem Wechsel in den Vollbildmodus auf den gewünschten Präsentationsbildschirm verschoben werden.
|
||
Der Vollbildmodus sperrt den Computer nicht gegen andere Eingaben.
|
||
|
||
-## Akustische Alarme (v0.5.3)
|
||
+## Akustische Alarme (aktualisiert v0.6.5)
|
||
|
||
Die akustische Alarmierung ist **standardmäßig eingeschaltet**. Im
|
||
Admin-Fenster lässt sie sich mit **Audible alarms** aktivieren bzw. stummschalten.
|
||
@@ -183,11 +183,14 @@ Mit **Test tone** kann die Tonausgabe unabhängig von der Stummschaltung geprüf
|
||
werden. Die optischen Alarme blinken bei stummgeschalteter Tonausgabe weiterhin.
|
||
|
||
- **Kritische Rhythmusalarme:** VT, PVT, Kammerflimmern und Asystolie lösen
|
||
- einen Doppelton aus (zweimal kurz 880 Hz), der ungefähr alle 1,5 Sekunden
|
||
- wiederholt wird.
|
||
+ einen **Zweiklang aus aufeinanderfolgenden, unterschiedlichen Tönen** aus
|
||
+ (880 Hz gefolgt von 1160 Hz), der ungefähr alle 1,5 Sekunden wiederholt wird.
|
||
- **Numerische und technische Alarme:** Grenzwertüberschreitungen sowie
|
||
- **NO SENSOR** und **NO READING** lösen einen kurzen Ton mit 700 Hz aus,
|
||
- der ungefähr alle 2,5 Sekunden wiederholt wird.
|
||
+ **NO SENSOR** und **NO READING** lösen ebenfalls einen **Zweitonalarm** aus
|
||
+ (700 Hz gefolgt von 950 Hz), der ungefähr alle 2,5 Sekunden wiederholt wird.
|
||
+- Zwischen beiden Tönen liegt jeweils eine kurze Pause. Ein einzelner
|
||
+ **QRS-Piepton** ist für eine spätere Version vorgesehen und wird derzeit
|
||
+ noch nicht ausgegeben.
|
||
- Kritische Alarme haben Vorrang. Auch bei mehreren gleichzeitig aktiven
|
||
Alarmen wird nur eine Tonfolge ausgegeben. Bei behobenem Alarm oder
|
||
Stummschaltung verstummt die Ausgabe. Ausgeblendete Monitorbereiche
|
||
@@ -619,3 +622,13 @@ mit **Apply** gespeichert; **Measure now** startet unmittelbar einen Messzyklus,
|
||
auch wenn die Automatik ausgeschaltet ist. Die Admin-Oberfläche wird
|
||
synchronisiert. Die anderen Parametermenüs bleiben auf Alarmgrenzen beschränkt.
|
||
Manschettenzuordnung und simulierter Messausfall verbleiben im Admin-Fenster.
|
||
+
|
||
+
|
||
+### v0.6.5 – Zweitonige akustische Alarme
|
||
+
|
||
+Sowohl Standard- und technische Alarme als auch kritische Rhythmusalarme
|
||
+bestehen nun aus zwei aufeinanderfolgenden Tönen unterschiedlicher Frequenz.
|
||
+Die Priorisierung und die Wiederholungsintervalle bleiben unverändert.
|
||
+**Test tone** spielt den Standard-Zweitonalarm. Ein einzelner QRS-Piepton
|
||
+ist für eine spätere Erweiterung reserviert. Optische Alarme und
|
||
+Simulationsverhalten wurden nicht verändert.
|
||
diff --git a/README.md b/README.md
|
||
index faab37e..f413723 100644
|
||
--- a/README.md
|
||
+++ b/README.md
|
||
@@ -1,4 +1,4 @@
|
||
-# Patient Monitor Simulation (PaMSim) — v0.6.4
|
||
+# Patient Monitor Simulation (PaMSim) — v0.6.5
|
||
|
||
A Rust/GTK4 patient-monitor simulator with two main windows for teaching on Fedora Linux.
|
||
|
||
@@ -166,17 +166,21 @@ The monitor can be resized and toggled fullscreen with **F11**; **Esc** exits
|
||
fullscreen. On Wayland, move the monitor to the presentation screen before
|
||
activating fullscreen. Fullscreen does not lock down the computer.
|
||
|
||
-## Audible alarms (v0.5.3)
|
||
+## Audible alarms (updated v0.6.5)
|
||
|
||
Sound is **enabled by default**. The Admin window has an **Audible alarms**
|
||
checkbox for muting and a **Test tone** button (works even while muted).
|
||
Visual alarms keep blinking normally when sound is off.
|
||
|
||
-- **Critical rhythm alarm:** VT, PVT, VF and asystole produce a double beep
|
||
- (two short 880 Hz tones), repeated approximately every 1.5 seconds.
|
||
+- **Critical rhythm alarm:** VT, PVT, VF and asystole produce a higher-pitched
|
||
+ **two-tone** alert (880 Hz followed by 1160 Hz), repeated approximately
|
||
+ every 1.5 seconds.
|
||
- **Numerical and SpO₂ technical alarms:** out-of-range values, **NO SENSOR**
|
||
- and **NO READING** produce a single 700 Hz beep, repeated approximately
|
||
- every 2.5 seconds.
|
||
+ and **NO READING** produce a lower-pitched **two-tone** alert
|
||
+ (700 Hz followed by 950 Hz), repeated approximately every 2.5 seconds.
|
||
+- Both alarm signals use two **different successive pitches**, separated by
|
||
+ a brief silence. A distinct **single QRS beep is reserved for future work**;
|
||
+ QRS-related audio is not yet implemented.
|
||
- Critical alarms have priority: only one tone pattern is played even if
|
||
multiple alarms are active. The sound stops when all alarms clear or when
|
||
the checkbox is unchecked. Alarms on hidden monitor channels are excluded.
|
||
@@ -634,3 +638,12 @@ are saved with Apply; Measure now starts a cuff cycle immediately regardless
|
||
of Auto. Both monitor and Admin display the selected settings. Other monitor
|
||
menus remain limited to alarm thresholds; NIBP cuff placement, the simulated
|
||
failed-reading option and non-NIBP signal settings remain Admin-only.
|
||
+
|
||
+
|
||
+### v0.6.5 — Two-tone audible alarms
|
||
+
|
||
+Both standard/technical and critical alarm sounds now consist of two distinct
|
||
+successive pitches. Critical alarms retain their priority and faster repeat
|
||
+interval; standard alarms retain their slower cadence. The Admin test button
|
||
+plays the standard two-tone alert. A single QRS beep is reserved for a later
|
||
+release and is not generated yet. No visual alarm or simulation logic changed.
|
||
diff --git a/src/alarm.rs b/src/alarm.rs
|
||
index 116b7f4..6e0b1af 100644
|
||
--- a/src/alarm.rs
|
||
+++ b/src/alarm.rs
|
||
@@ -84,14 +84,21 @@ pub fn level(p: &Parameters, sim: &Simulator) -> AlarmLevel {
|
||
result
|
||
}
|
||
|
||
-/// Very short, original synthesized sine beeps; mono PCM16 WAV.
|
||
+/// Both alarm priorities sound as two successive, different pitches.
|
||
+/// A future QRS beep will be a separate, single-tone signal.
|
||
+/// Zero-frequency segments are short silences between the notes.
|
||
+fn tone_segments(critical: bool) -> &'static [(f64, f64)] {
|
||
+ if critical {
|
||
+ &[(880.0, 0.16), (0.0, 0.08), (1160.0, 0.16)]
|
||
+ } else {
|
||
+ &[(700.0, 0.14), (0.0, 0.06), (950.0, 0.14)]
|
||
+ }
|
||
+}
|
||
+
|
||
+/// Very short, original synthesized two-tone alerts; mono PCM16 WAV.
|
||
fn wav(critical: bool) -> Vec<u8> {
|
||
const SAMPLE_RATE: u32 = 44_100;
|
||
- let segments: &[(f64, f64)] = if critical {
|
||
- &[(880.0, 0.16), (0.0, 0.09), (880.0, 0.16)]
|
||
- } else {
|
||
- &[(700.0, 0.18)]
|
||
- };
|
||
+ let segments = tone_segments(critical);
|
||
let samples: usize = segments.iter()
|
||
.map(|(_, seconds)| (seconds * f64::from(SAMPLE_RATE)).round() as usize)
|
||
.sum();
|
||
@@ -267,8 +274,9 @@ impl AlarmAudio {
|
||
}
|
||
|
||
/// Called from a 100-ms GLib timer, not the 250-Hz waveform simulator.
|
||
- /// Critical rhythms: double tone every 1.5 s; other alarms: single tone
|
||
- /// every 2.5 s. Stop promptly when muted or all alarm states clear.
|
||
+ /// Critical rhythms: higher-pitched two-tone alert every 1.5 s;
|
||
+ /// other alarms: lower-pitched two-tone alert every 2.5 s.
|
||
+ /// Stop promptly when muted or all alarm states clear.
|
||
pub fn update(&mut self, level: AlarmLevel, enabled: bool) {
|
||
self.reap();
|
||
if !enabled || level == AlarmLevel::None {
|
||
@@ -322,6 +330,21 @@ mod tests {
|
||
assert!(wav(true).len() > wav(false).len());
|
||
}
|
||
|
||
+ #[test]
|
||
+ fn both_alarm_priorities_have_two_distinct_audible_pitches() {
|
||
+ for critical in [false, true] {
|
||
+ let segments = tone_segments(critical);
|
||
+ let notes: Vec<f64> = segments.iter()
|
||
+ .filter_map(|(hz, _seconds)| (*hz > 0.0).then_some(*hz))
|
||
+ .collect();
|
||
+ assert_eq!(notes.len(), 2, "each alarm pattern must contain two notes");
|
||
+ assert_ne!(notes[0], notes[1], "a two-tone alert needs distinct pitches");
|
||
+ assert!(segments.iter().any(|(hz, _)| *hz == 0.0), "notes must be separated");
|
||
+ assert!(segments.iter().all(|(_, seconds)| *seconds > 0.0));
|
||
+ }
|
||
+ assert_ne!(wav(false), wav(true));
|
||
+ }
|
||
+
|
||
#[test]
|
||
fn normal_signals_are_silent_and_numeric_limit_alarms_beep() {
|
||
let mut p = Parameters::default();
|