diff --git a/Cargo.toml b/Cargo.toml
|
||
index debf638..d2a7098 100644
|
||
--- a/Cargo.toml
|
||
+++ b/Cargo.toml
|
||
@@ -1,6 +1,6 @@
|
||
[package]
|
||
name = "patient-monitor-simulation"
|
||
-version = "0.5.3"
|
||
+version = "0.5.4"
|
||
edition = "2021"
|
||
license = "MIT"
|
||
description = "Synthetic patient-monitor simulation for teaching (not for clinical use)"
|
||
diff --git a/README.de.md b/README.de.md
|
||
index 374281f..f7c5ba2 100644
|
||
--- a/README.de.md
|
||
+++ b/README.de.md
|
||
@@ -1,4 +1,4 @@
|
||
-# Patient Monitor Simulation (PaMSim) — v0.5.3
|
||
+# Patient Monitor Simulation (PaMSim) — v0.5.4
|
||
|
||
Ein mit Rust und GTK4 entwickelter Patient*innenmonitor-Simulator mit zwei Fenstern für die Lehre unter Fedora Linux.
|
||
|
||
@@ -6,6 +6,53 @@ Ein mit Rust und GTK4 entwickelter Patient*innenmonitor-Simulator mit zwei Fenst
|
||
> EKG, invasive arterielle Druckkurve, Plethysmogramm und Kapnogramm sind schematische mathematische Annäherungen.
|
||
> Die Simulation wurde nicht klinisch validiert und ist kein Medizinprodukt.
|
||
|
||
+## Thoraxkompressionen (v0.5.4)
|
||
+
|
||
+Im Admin-Bereich **Chest compressions** startet die grüne Schaltfläche
|
||
+**Start Chest Compressions** die Simulation. Während aktiver Kompressionen
|
||
+wechselt sie zu **Stop Chest Compressions** mit rotem Hintergrund.
|
||
+Die **Compression quality** kann jederzeit auf **Good**, **Adequate**
|
||
+(Standard), **Poor** oder **Bad** gestellt werden.
|
||
+
|
||
+- Die Kompressionsfrequenz schwankt zufällig im Bereich **90–110/min**;
|
||
+ für jeden Druckstoß werden Frequenz und Druckhöhe neu festgelegt.
|
||
+ Der eingestellte EKG-Rhythmus und die elektrische Herzfrequenz bleiben
|
||
+ unverändert.
|
||
+- Das EKG wird durch kompressionssynchrone Bewegungsartefakte überlagert.
|
||
+ Besteht ein **eigener arterieller Kreislauf**, bleibt die ursprüngliche
|
||
+ Druckkurve bestehen, wird jedoch durch Kompressionen verzerrt.
|
||
+- **Ohne eigenständige arterielle Pulsation** (beispielsweise bei KF, PVT,
|
||
+ Asystolie oder PEA) erzeugen wirksame Kompressionen breite, stumpfe
|
||
+ arterielle Druckwellen:
|
||
+
|
||
+ | Kompressionsqualität | Systolischer ART-Spitzendruck |
|
||
+ | --- | --- |
|
||
+ | Good | 90 mmHg ±10 % (81–99 mmHg) |
|
||
+ | Adequate (Standard) | 70 mmHg ±10 % (63–77 mmHg) |
|
||
+ | Poor | 50 mmHg, +10 % / −50 % (25–55 mmHg) |
|
||
+ | Bad | Kein durch Kompressionen erzeugter Druck; Grundschwankung von 0–5 mmHg |
|
||
+
|
||
+ Bei fehlender Eigenpulsation zeigt **ART SYS** den Spitzendruck der
|
||
+ aktuellen Kompression; **DIA/MAP** bleiben `--`, da sie aus der synthetischen
|
||
+ Kurve nicht verlässlich bestimmt werden.
|
||
+- Ein SpO₂-Messwert und ein Plethysmogramm werden während laufender
|
||
+ Kompressionen **nur bei Qualität Good** angezeigt, vorausgesetzt, der Sensor
|
||
+ ist angeschlossen und nicht durch eine NIBP-Manschette okkludiert.
|
||
+ Die angezeigte Signalqualität beträgt unabhängig von der Grundeinstellung
|
||
+ **Poor (★)**. Die angezeigte **PR folgt der Kompressionsfrequenz (90–110/min)**,
|
||
+ nicht der EKG-Frequenz. Bei Adequate, Poor oder Bad erscheint **NO READING**,
|
||
+ bei abgezogenem Sensor **NO SENSOR**. Die durch Kompressionen erzwungene
|
||
+ Signalqualität Poor führt nicht zu den sonst üblichen periodischen
|
||
+ Aussetzern; bei regulärer Grundeinstellung Poor gelten diese nach Ende
|
||
+ der Kompressionen wieder.
|
||
+- Die bestehenden Rhythmus- und Grenzwertalarme bleiben aktiv. ART-SYS-Grenzen
|
||
+ beziehen sich dabei auf die Kompressionsspitzen. Die NIBP-Messintervalle bleiben unverändert; die Dauer eines Messzyklus
|
||
+ richtet sich weiterhin nach der wirksamen SpO₂-Signalqualität beim Start.
|
||
+
|
||
+**Hinweis:** Druckwerte und Signalformen sind didaktisch gewählt und nicht
|
||
+klinisch validiert. Aus dieser Simulation darf keine reale Wirksamkeit von
|
||
+Reanimationsmaßnahmen abgeleitet werden.
|
||
+
|
||
## Installation, Kompilierung und Start unter Fedora
|
||
|
||
```bash
|
||
diff --git a/README.md b/README.md
|
||
index 20d5943..30ec481 100644
|
||
--- a/README.md
|
||
+++ b/README.md
|
||
@@ -1,4 +1,4 @@
|
||
-# Patient Monitor Simulation (PaMSim) — v0.5.3
|
||
+# Patient Monitor Simulation (PaMSim) — v0.5.4
|
||
|
||
A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux.
|
||
|
||
@@ -6,6 +6,47 @@ A two-window, Rust/GTK4 patient-monitor simulator for teaching on Fedora Linux.
|
||
> plethysmography and capnography are schematic mathematical approximations. The
|
||
> simulation has no clinical validation and is not a medical device.
|
||
|
||
+## Chest compressions (v0.5.4)
|
||
+
|
||
+The **Chest compressions** Admin group provides a large **Start Chest Compressions**
|
||
+button (green background). While active it changes to **Stop Chest Compressions**
|
||
+(red background). **Compression quality** can be changed at any time:
|
||
+**Good**, **Adequate** (default), **Poor**, or **Bad**.
|
||
+
|
||
+- Compressions are generated independently of the ECG at **90–110/min**, with
|
||
+ a new reproducible pseudo-random compression rate and pressure each stroke.
|
||
+ **The ECG rhythm and electrical HR setting are not changed.**
|
||
+- Every compression adds movement artifact to the ECG. In a patient with
|
||
+ **existing intrinsic arterial perfusion**, the native arterial waveform is
|
||
+ preserved but distorted by compression-synchronous pressure artifact.
|
||
+- With **no intrinsic arterial pulse** (e.g., VF, PVT, asystole or PEA),
|
||
+ each effective compression generates a broad, blunt arterial pressure wave:
|
||
+
|
||
+ | Compression quality | Compression-generated ART systolic peak |
|
||
+ | --- | --- |
|
||
+ | Good | 90 mmHg ±10% (81–99 mmHg) |
|
||
+ | Adequate (default) | 70 mmHg ±10% (63–77 mmHg) |
|
||
+ | Poor | 50 mmHg, +10% / −50% (25–55 mmHg) |
|
||
+ | Bad | No compression-generated arterial pressure; 0–5 mmHg baseline drift |
|
||
+
|
||
+ During pulseless CPR, **ART SYS** shows the current compression peak,
|
||
+ while **DIA/MAP** remain `--` (not estimable from this synthetic pressure).
|
||
+- SpO₂ numeric saturation and the pleth waveform remain visible **only when
|
||
+ compression quality is Good**, provided the sensor is connected and not
|
||
+ occluded by an NIBP cuff. Their effective signal quality is forced to
|
||
+ **Poor (★)**, irrespective of the normal Admin quality setting. The displayed
|
||
+ pleth-derived **PR follows the compression rate (90–110/min)**, not the ECG.
|
||
+ Adequate, Poor and Bad CPR display **NO READING**; detached sensors display
|
||
+ **NO SENSOR**. Compression-induced Poor quality does not schedule the usual
|
||
+ intermittent dropout; that resumes when ordinary Poor signal mode returns.
|
||
+- Existing numerical alarms and rhythm alarms remain active. ART SYS limits
|
||
+ apply to compression-generated systolic peaks; NIBP scheduling remains unchanged; its cycle duration still depends on
|
||
+ effective SpO₂ quality at the start of a measurement.
|
||
+
|
||
+These pressure targets are **didactic assumptions**, not validated CPR
|
||
+hemodynamic criteria. The exercise must not be used to judge real compression
|
||
+quality or clinical perfusion.
|
||
+
|
||
## Build and run on Fedora
|
||
|
||
```bash
|
||
diff --git a/src/alarm.rs b/src/alarm.rs
|
||
index d368f20..116b7f4 100644
|
||
--- a/src/alarm.rs
|
||
+++ b/src/alarm.rs
|
||
@@ -35,7 +35,6 @@ pub fn level(p: &Parameters, sim: &Simulator) -> AlarmLevel {
|
||
let captured = p.ecg_rhythm.can_generate_pulse()
|
||
&& p.heart_rate > 0
|
||
&& p.pulse_conduction != PulseConduction::None;
|
||
- let pr = if captured { sim.pulse_rate() } else { None };
|
||
|
||
if p.show_ecg {
|
||
if p.ecg_rhythm.rhythm_alarm().is_some() {
|
||
@@ -47,10 +46,10 @@ pub fn level(p: &Parameters, sim: &Simulator) -> AlarmLevel {
|
||
}
|
||
|
||
if p.show_spo2 {
|
||
- let status = p.spo2_status_at_quality(pr, sim.poor_signal_lost(), sim.spo2_quality(p));
|
||
+ let status = sim.spo2_status(p);
|
||
if status != Spo2Status::Available
|
||
|| outside(p.alarms.spo2, Some(p.spo2))
|
||
- || outside(p.alarms.pr, pr)
|
||
+ || outside(p.alarms.pr, sim.spo2_pulse_rate(p))
|
||
{
|
||
result = AlarmLevel::Standard;
|
||
}
|
||
diff --git a/src/model.rs b/src/model.rs
|
||
index 996d6ba..009b231 100644
|
||
--- a/src/model.rs
|
||
+++ b/src/model.rs
|
||
@@ -83,6 +83,29 @@ pub enum CapnoShape {
|
||
Obstructive,
|
||
}
|
||
|
||
+/// Instructor-selected efficacy of manual chest compressions.
|
||
+/// This affects synthetic pressure and pleth signals, not ECG rhythm or HR.
|
||
+#[derive(Clone, Copy, Debug, PartialEq, Eq)]
|
||
+pub enum ChestCompressionQuality {
|
||
+ Good,
|
||
+ Adequate,
|
||
+ Poor,
|
||
+ Bad,
|
||
+}
|
||
+
|
||
+impl ChestCompressionQuality {
|
||
+ /// Approximate compression-generated systolic peak pressure (mmHg).
|
||
+ /// None means that compressions generate no measurable arterial pressure.
|
||
+ pub fn peak_range(self) -> Option<(f64, f64)> {
|
||
+ match self {
|
||
+ Self::Good => Some((81.0, 99.0)), // 90 +/- 10%
|
||
+ Self::Adequate => Some((63.0, 77.0)), // 70 +/- 10%
|
||
+ Self::Poor => Some((25.0, 55.0)), // 50 -50% / +10%
|
||
+ Self::Bad => None,
|
||
+ }
|
||
+ }
|
||
+}
|
||
+
|
||
/// Instructor-selected plethysmography signal quality; separate from the
|
||
/// physiological oxygen-saturation setting and mechanical pulse capture.
|
||
#[derive(Clone, Copy, Debug, PartialEq, Eq)]
|
||
@@ -202,6 +225,8 @@ pub struct Parameters {
|
||
pub patient_name: String, // displayed in the monitor header, blank = generic title
|
||
pub alarms: AlarmSettings,
|
||
pub audible_alarms: bool, // mute only the sound, never the visual alarms
|
||
+ pub chest_compressions_active: bool,
|
||
+ pub chest_compression_quality: ChestCompressionQuality,
|
||
pub ecg_rhythm: EcgRhythm,
|
||
pub heart_rate: i32, // bpm, organized electrical rate; not mechanical pulse rate
|
||
pub pulse_conduction: PulseConduction,
|
||
@@ -277,6 +302,8 @@ impl Default for Parameters {
|
||
patient_name: String::new(),
|
||
alarms: AlarmSettings::default(),
|
||
audible_alarms: true,
|
||
+ chest_compressions_active: false,
|
||
+ chest_compression_quality: ChestCompressionQuality::Adequate,
|
||
ecg_rhythm: EcgRhythm::Sinus,
|
||
heart_rate: 75,
|
||
pulse_conduction: PulseConduction::OneToOne,
|
||
@@ -313,6 +340,17 @@ pub fn mean_arterial_pressure(systolic: i32, diastolic: i32) -> i32 {
|
||
mod tests {
|
||
use super::*;
|
||
|
||
+ #[test]
|
||
+ fn compression_quality_defaults_to_adequate_and_has_requested_pressure_ranges() {
|
||
+ let p = Parameters::default();
|
||
+ assert!(!p.chest_compressions_active);
|
||
+ assert_eq!(p.chest_compression_quality, ChestCompressionQuality::Adequate);
|
||
+ assert_eq!(ChestCompressionQuality::Good.peak_range(), Some((81.0, 99.0)));
|
||
+ assert_eq!(ChestCompressionQuality::Adequate.peak_range(), Some((63.0, 77.0)));
|
||
+ assert_eq!(ChestCompressionQuality::Poor.peak_range(), Some((25.0, 55.0)));
|
||
+ assert_eq!(ChestCompressionQuality::Bad.peak_range(), None);
|
||
+ }
|
||
+
|
||
#[test]
|
||
fn mean_pressure_uses_one_third_pulse_pressure() {
|
||
assert_eq!(mean_arterial_pressure(120, 75), 90);
|
||
diff --git a/src/render.rs b/src/render.rs
|
||
index 8cce43d..4053fe1 100644
|
||
--- a/src/render.rs
|
||
+++ b/src/render.rs
|
||
@@ -150,6 +150,7 @@ fn draw_nibp_box(cr: &Context, x: f64, top: f64, width: f64, height: f64,
|
||
], right, top, height * 0.65, width * 0.72);
|
||
}
|
||
|
||
+#[cfg(test)]
|
||
fn pleth_trace_enabled(p: &Parameters) -> bool {
|
||
p.spo2_sensor_attached && p.spo2_quality != Spo2Quality::None
|
||
}
|
||
@@ -160,9 +161,16 @@ fn spo2_vitals(p: &Parameters, pulse_rate: Option<i32>, signal_lost: bool)
|
||
spo2_vitals_at_quality(p, pulse_rate, signal_lost, p.spo2_quality)
|
||
}
|
||
|
||
+#[cfg(test)]
|
||
fn spo2_vitals_at_quality(p: &Parameters, pulse_rate: Option<i32>, signal_lost: bool,
|
||
quality: Spo2Quality) -> (String, String, String) {
|
||
- match p.spo2_status_at_quality(pulse_rate, signal_lost, quality) {
|
||
+ spo2_vitals_for_status(p, pulse_rate, quality,
|
||
+ p.spo2_status_at_quality(pulse_rate, signal_lost, quality))
|
||
+}
|
||
+
|
||
+fn spo2_vitals_for_status(p: &Parameters, pulse_rate: Option<i32>, quality: Spo2Quality,
|
||
+ status: Spo2Status) -> (String, String, String) {
|
||
+ match status {
|
||
Spo2Status::NoSensor => (
|
||
"SpO₂".to_owned(), "NO SENSOR".to_owned(), "PR -- bpm".to_owned()),
|
||
Spo2Status::NoReading => (
|
||
@@ -196,10 +204,11 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64,
|
||
&& p.heart_rate > 0
|
||
&& p.pulse_conduction != PulseConduction::None;
|
||
let pulse_rate = if has_capture { sim.pulse_rate() } else { None };
|
||
+ let spo2_rate = sim.spo2_pulse_rate(p);
|
||
let ecg_hr = if p.ecg_rhythm.has_qrs() && p.heart_rate > 0 {
|
||
Some(p.heart_rate)
|
||
} else { None };
|
||
- let spo2_status = p.spo2_status_at_quality(pulse_rate, sim.poor_signal_lost(), sim.spo2_quality(p));
|
||
+ let spo2_status = sim.spo2_status(p);
|
||
let oxygen = if spo2_status == Spo2Status::Available { Some(p.spo2) } else { None };
|
||
|
||
let limits: Vec<(&str, AlarmLimits)> = match ch {
|
||
@@ -228,8 +237,8 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64,
|
||
}
|
||
}
|
||
Channel::Pleth => {
|
||
- let (label, value, info) = spo2_vitals_at_quality(p, pulse_rate,
|
||
- sim.poor_signal_lost(), sim.spo2_quality(p));
|
||
+ let (label, value, info) = spo2_vitals_for_status(p, spo2_rate,
|
||
+ sim.spo2_quality(p), spo2_status);
|
||
text(cr, &label, x, top + row_h * 0.24, label_size, color, false);
|
||
let technical_alarm = spo2_status != Spo2Status::Available;
|
||
let value_size = if technical_alarm {
|
||
@@ -239,8 +248,8 @@ fn draw_vitals(cr: &Context, ch: Channel, color: Color, x: f64,
|
||
width, color, technical_alarm || alarmed(p.alarms.spo2, oxygen), flash);
|
||
if oxygen.is_some() {
|
||
draw_alarm_inline(cr, x, info_y, sub_size, width, color,
|
||
- "% PR ", &pulse_rate.unwrap_or_default().to_string(), " bpm",
|
||
- alarmed(p.alarms.pr, pulse_rate), flash);
|
||
+ "% PR ", &spo2_rate.unwrap_or_default().to_string(), " bpm",
|
||
+ alarmed(p.alarms.pr, spo2_rate), flash);
|
||
} else {
|
||
text(cr, &info, x, info_y, sub_size, color, false);
|
||
}
|
||
@@ -427,9 +436,7 @@ fn draw_trace(cr: &Context, channel: Channel, color: Color,
|
||
|
||
// Disconnected or absent pleth signal: no curve, including historical pulses.
|
||
if matches!(channel, Channel::Pleth)
|
||
- && (!pleth_trace_enabled(p)
|
||
- || p.spo2_status_at_quality(sim.pulse_rate(), sim.poor_signal_lost(),
|
||
- sim.spo2_quality(p)) != Spo2Status::Available)
|
||
+ && sim.spo2_status(p) != Spo2Status::Available
|
||
{
|
||
let _ = cr.restore();
|
||
return;
|
||
diff --git a/src/simulation.rs b/src/simulation.rs
|
||
index c148a30..06fd000 100644
|
||
--- a/src/simulation.rs
|
||
+++ b/src/simulation.rs
|
||
@@ -2,7 +2,8 @@
|
||
//! A conducted QRS schedules an arterial pulse and a delayed, smoothed pleth pulse.
|
||
use std::collections::VecDeque;
|
||
|
||
-use crate::model::{ArterialShape, CapnoShape, EcgRhythm, Parameters, PulseConduction, Spo2Quality};
|
||
+use crate::model::{ArterialShape, CapnoShape, ChestCompressionQuality, EcgRhythm,
|
||
+ Parameters, PulseConduction, Spo2Quality, Spo2Status};
|
||
use crate::nibp::{CuffZone, NibpMachine, NibpReading};
|
||
|
||
const SAMPLE_STEP: f64 = 0.004; // 250 Hz; adequately samples the QRS upstroke
|
||
@@ -87,6 +88,91 @@ impl PoorSignalOutages {
|
||
}
|
||
}
|
||
|
||
+/// CPR is a separate mechanical clock, independent of intrinsic cardiac rate.
|
||
+/// Randomness is sampled once per compression, so peaks and intervals remain
|
||
+/// stable during drawing and are reproducible in tests.
|
||
+#[derive(Debug)]
|
||
+struct ChestCompressions {
|
||
+ active: bool,
|
||
+ phase: f64,
|
||
+ rate_bpm: f64,
|
||
+ peak_pressure: f64,
|
||
+ quality: ChestCompressionQuality,
|
||
+ rng: u64,
|
||
+}
|
||
+
|
||
+impl ChestCompressions {
|
||
+ fn new() -> Self {
|
||
+ Self { active: false, phase: 0.0, rate_bpm: 100.0,
|
||
+ peak_pressure: 0.0, quality: ChestCompressionQuality::Adequate,
|
||
+ rng: 0xC0FF_EE12_3456_789A }
|
||
+ }
|
||
+
|
||
+ fn random_unit(&mut self) -> f64 {
|
||
+ self.rng = self.rng.wrapping_mul(6_364_136_223_846_793_005)
|
||
+ .wrapping_add(1_442_695_040_888_963_407);
|
||
+ (self.rng >> 11) as f64 / (1_u64 << 53) as f64
|
||
+ }
|
||
+
|
||
+ fn choose_peak(&mut self) {
|
||
+ self.peak_pressure = match self.quality.peak_range() {
|
||
+ Some((low, high)) => low + (high - low) * self.random_unit(),
|
||
+ None => 0.0,
|
||
+ };
|
||
+ }
|
||
+
|
||
+ fn update(&mut self, enabled: bool, quality: ChestCompressionQuality) {
|
||
+ if !enabled {
|
||
+ self.active = false;
|
||
+ self.phase = 0.0;
|
||
+ self.peak_pressure = 0.0;
|
||
+ return;
|
||
+ }
|
||
+ if !self.active {
|
||
+ self.active = true;
|
||
+ self.phase = 0.0;
|
||
+ self.rate_bpm = 90.0 + self.random_unit() * 20.0;
|
||
+ self.quality = quality;
|
||
+ self.choose_peak();
|
||
+ } else if self.quality != quality {
|
||
+ self.quality = quality;
|
||
+ self.choose_peak();
|
||
+ }
|
||
+ self.phase += SAMPLE_STEP * self.rate_bpm / 60.0;
|
||
+ if self.phase >= 1.0 {
|
||
+ self.phase = self.phase.fract();
|
||
+ self.rate_bpm = 90.0 + self.random_unit() * 20.0;
|
||
+ self.choose_peak();
|
||
+ }
|
||
+ }
|
||
+
|
||
+ fn pressure_wave(&self) -> f64 {
|
||
+ // Rounded, broad compression crest (no narrow physiological upstroke).
|
||
+ let rise = smooth_step(self.phase / 0.22);
|
||
+ let fall = 1.0 - smooth_step((self.phase - 0.36) / 0.43);
|
||
+ (rise * fall).clamp(0.0, 1.0)
|
||
+ }
|
||
+
|
||
+ fn pleth_wave(&self) -> f64 {
|
||
+ // A delayed, deliberately weak mechanical pleth pulse.
|
||
+ let phase = (self.phase - 0.26).rem_euclid(1.0);
|
||
+ smooth_step(phase / 0.27) * (1.0 - smooth_step((phase - 0.27) / 0.62))
|
||
+ }
|
||
+
|
||
+ fn ecg_artifact(&self, time: f64) -> f64 {
|
||
+ // Compression-synchronous baseline motion and jagged contact artifact.
|
||
+ let wave = self.pressure_wave();
|
||
+ 0.56 * (wave - 0.30)
|
||
+ + 0.12 * (time * 71.0).sin() * wave
|
||
+ + 0.08 * (time * 113.0).sin() * wave
|
||
+ }
|
||
+}
|
||
+
|
||
+fn smooth_step(value: f64) -> f64 {
|
||
+ let t = value.clamp(0.0, 1.0);
|
||
+ t * t * (3.0 - 2.0 * t)
|
||
+}
|
||
+
|
||
pub struct Simulator {
|
||
samples: VecDeque<Sample>,
|
||
time: f64,
|
||
@@ -100,6 +186,7 @@ pub struct Simulator {
|
||
previous_conduction: PulseConduction,
|
||
previous_heart_rate: i32,
|
||
poor_signal_outages: PoorSignalOutages,
|
||
+ compressions: ChestCompressions,
|
||
nibp: NibpMachine,
|
||
art_hold_pressure: Option<f64>,
|
||
pending_time: f64,
|
||
@@ -120,6 +207,7 @@ impl Simulator {
|
||
previous_conduction: params.pulse_conduction,
|
||
previous_heart_rate: params.heart_rate,
|
||
poor_signal_outages: PoorSignalOutages::new(),
|
||
+ compressions: ChestCompressions::new(),
|
||
nibp: NibpMachine::new(),
|
||
art_hold_pressure: None,
|
||
pending_time: 0.0,
|
||
@@ -149,7 +237,43 @@ impl Simulator {
|
||
pub fn time(&self) -> f64 { self.time }
|
||
|
||
pub fn spo2_quality(&self, p: &Parameters) -> Spo2Quality {
|
||
- self.nibp.effective_spo2_quality(self.time, p)
|
||
+ if !p.chest_compressions_active {
|
||
+ return self.nibp.effective_spo2_quality(self.time, p);
|
||
+ }
|
||
+ if p.chest_compression_quality != ChestCompressionQuality::Good {
|
||
+ return Spo2Quality::None;
|
||
+ }
|
||
+ // During effective CPR the pleth signal is Poor regardless of Admin's
|
||
+ // baseline quality; an occlusive NIBP cuff can still suppress it.
|
||
+ if p.nibp_cuff_on_spo2 {
|
||
+ match self.nibp.cuff_zone(self.time, p) {
|
||
+ CuffZone::Occluded => return Spo2Quality::None,
|
||
+ CuffZone::Partial | CuffZone::Free => {}
|
||
+ }
|
||
+ }
|
||
+ Spo2Quality::Poor
|
||
+ }
|
||
+
|
||
+ /// Display-only pulse rate: under effective CPR the peripheral signal
|
||
+ /// follows compressions rather than non-perfusing electrical QRS events.
|
||
+ pub fn spo2_pulse_rate(&self, p: &Parameters) -> Option<i32> {
|
||
+ if p.chest_compressions_active {
|
||
+ (p.chest_compression_quality == ChestCompressionQuality::Good)
|
||
+ .then_some(self.compressions.rate_bpm.round() as i32)
|
||
+ } else {
|
||
+ self.pulse_rate()
|
||
+ }
|
||
+ }
|
||
+
|
||
+ pub fn spo2_status(&self, p: &Parameters) -> Spo2Status {
|
||
+ if !p.spo2_sensor_attached { return Spo2Status::NoSensor; }
|
||
+ if p.chest_compressions_active {
|
||
+ return if p.chest_compression_quality == ChestCompressionQuality::Good
|
||
+ && self.spo2_quality(p) != Spo2Quality::None
|
||
+ { Spo2Status::Available } else { Spo2Status::NoReading };
|
||
+ }
|
||
+ p.spo2_status_at_quality(self.pulse_rate(), self.poor_signal_lost(),
|
||
+ self.spo2_quality(p))
|
||
}
|
||
|
||
pub fn start_nibp_now(&mut self, p: &Parameters) {
|
||
@@ -161,7 +285,7 @@ impl Simulator {
|
||
if !p.spo2_sensor_attached || self.poor_signal_outages.active {
|
||
Spo2Quality::None
|
||
} else {
|
||
- p.spo2_quality
|
||
+ self.spo2_quality(p)
|
||
}
|
||
}
|
||
|
||
@@ -169,6 +293,11 @@ impl Simulator {
|
||
pub fn displayed_art_pressures(&self, p: &Parameters, has_capture: bool)
|
||
-> (Option<i32>, Option<i32>, Option<i32>) {
|
||
if !has_capture {
|
||
+ // During pulseless CPR the upper ART number reflects the peak
|
||
+ // compression pressure; DIA/MAP remain intentionally unassessed.
|
||
+ if self.compressions.active && p.chest_compression_quality != ChestCompressionQuality::Bad {
|
||
+ return (Some(self.compressions.peak_pressure.round() as i32), None, None);
|
||
+ }
|
||
return (self.measured_art_pressure(), None, None);
|
||
}
|
||
if p.nibp_cuff_on_art {
|
||
@@ -219,8 +348,11 @@ impl Simulator {
|
||
|
||
fn step(&mut self, params: &Parameters) {
|
||
self.time += SAMPLE_STEP;
|
||
+ self.compressions.update(params.chest_compressions_active,
|
||
+ params.chest_compression_quality);
|
||
self.poor_signal_outages.update(self.time,
|
||
- params.spo2_quality == Spo2Quality::Poor && params.spo2_sensor_attached);
|
||
+ !params.chest_compressions_active && params.spo2_quality == Spo2Quality::Poor
|
||
+ && params.spo2_sensor_attached);
|
||
// Snapshot the unoccluded sensor quality at the start of a cuff cycle.
|
||
// Cuff-induced signal loss during that cycle must not change its duration.
|
||
let start_quality = self.nibp_start_quality(params);
|
||
@@ -289,8 +421,25 @@ impl Simulator {
|
||
self.rate_qrs.pop_front();
|
||
}
|
||
|
||
- let ecg = ecg_amplitude(self.ecg_phase, self.time, params.ecg_rhythm, params.heart_rate);
|
||
- let (normal_art, pleth_target) = self.mechanical_signals(params);
|
||
+ let mut ecg = ecg_amplitude(self.ecg_phase, self.time, params.ecg_rhythm, params.heart_rate);
|
||
+ let (mut normal_art, mut pleth_target) = self.mechanical_signals(params);
|
||
+ if self.compressions.active {
|
||
+ ecg += self.compressions.ecg_artifact(self.time);
|
||
+ let perfusing = params.ecg_rhythm.can_generate_pulse()
|
||
+ && params.pulse_conduction != PulseConduction::None && params.heart_rate > 0;
|
||
+ let wave = self.compressions.pressure_wave();
|
||
+ if perfusing {
|
||
+ // Preserve the patient's intrinsic pressure, with superimposed
|
||
+ // compression-synchronous artifact even during bad CPR.
|
||
+ normal_art = (normal_art + 22.0 * (wave - 0.32)).clamp(0.0, 250.0);
|
||
+ } else if self.compressions.peak_pressure > 0.0 {
|
||
+ let baseline = pulseless_arterial_drift(self.time);
|
||
+ normal_art = baseline + (self.compressions.peak_pressure - baseline) * wave;
|
||
+ }
|
||
+ pleth_target = if params.chest_compression_quality == ChestCompressionQuality::Good {
|
||
+ 0.85 * self.compressions.pleth_wave()
|
||
+ } else { 0.0 };
|
||
+ }
|
||
let art = self.art_with_cuff(normal_art, params);
|
||
let smoothing = 1.0 - (-SAMPLE_STEP / PLETH_FILTER_TAU).exp();
|
||
self.filtered_pleth += smoothing * (pleth_target - self.filtered_pleth);
|
||
@@ -301,9 +450,7 @@ impl Simulator {
|
||
};
|
||
|
||
let pleth_quality = self.spo2_quality(params);
|
||
- let pleth_valid = params.spo2_sensor_attached
|
||
- && pleth_quality != Spo2Quality::None
|
||
- && !self.poor_signal_outages.active;
|
||
+ let pleth_valid = self.spo2_status(params) == Spo2Status::Available;
|
||
self.samples.push_back(Sample {
|
||
time: self.time, ecg, pleth, pleth_valid, pleth_quality, art, co2,
|
||
});
|
||
@@ -313,9 +460,10 @@ impl Simulator {
|
||
}
|
||
|
||
fn art_with_cuff(&mut self, normal_art: f64, params: &Parameters) -> f64 {
|
||
- if !params.nibp_cuff_on_art || !params.ecg_rhythm.can_generate_pulse()
|
||
- || params.pulse_conduction == PulseConduction::None || params.heart_rate <= 0
|
||
- {
|
||
+ let native_pulse = params.ecg_rhythm.can_generate_pulse()
|
||
+ && params.pulse_conduction != PulseConduction::None && params.heart_rate > 0;
|
||
+ let compression_pulse = self.compressions.active && self.compressions.peak_pressure > 0.0;
|
||
+ if !params.nibp_cuff_on_art || !(native_pulse || compression_pulse) {
|
||
self.art_hold_pressure = None;
|
||
return normal_art;
|
||
}
|
||
@@ -545,6 +693,129 @@ mod tests {
|
||
sim
|
||
}
|
||
|
||
+ #[test]
|
||
+ fn compression_rate_varies_only_between_90_and_110_bpm() {
|
||
+ let mut cpr = ChestCompressions::new();
|
||
+ let mut observed = Vec::new();
|
||
+ for _ in 0..(25.0 / SAMPLE_STEP) as usize {
|
||
+ let previous = cpr.phase;
|
||
+ cpr.update(true, ChestCompressionQuality::Good);
|
||
+ assert!((90.0..=110.0).contains(&cpr.rate_bpm));
|
||
+ if cpr.phase < previous { observed.push(cpr.rate_bpm); }
|
||
+ }
|
||
+ assert!(observed.len() >= 30);
|
||
+ assert!(observed.iter().any(|rate| (rate - observed[0]).abs() > 1.0));
|
||
+ cpr.update(false, ChestCompressionQuality::Good);
|
||
+ assert!(!cpr.active);
|
||
+ assert_eq!(cpr.peak_pressure, 0.0);
|
||
+ }
|
||
+
|
||
+ #[test]
|
||
+ fn compressions_generate_requested_pulseless_arterial_pressure_by_quality() {
|
||
+ for (quality, limits) in [
|
||
+ (ChestCompressionQuality::Good, Some((81.0, 99.0))),
|
||
+ (ChestCompressionQuality::Adequate, Some((63.0, 77.0))),
|
||
+ (ChestCompressionQuality::Poor, Some((25.0, 55.0))),
|
||
+ (ChestCompressionQuality::Bad, None),
|
||
+ ] {
|
||
+ let p = Parameters { ecg_rhythm: EcgRhythm::VentricularFibrillation,
|
||
+ chest_compressions_active: true, chest_compression_quality: quality,
|
||
+ ..Parameters::default() };
|
||
+ let mut sim = Simulator::new(&p);
|
||
+ for _ in 0..(2.0 / SAMPLE_STEP) as usize { sim.step(&p); }
|
||
+ assert_eq!(sim.pulse_rate(), None, "no intrinsic QRS pulse in VF");
|
||
+ let recent: Vec<_> = sim.samples.iter().rev().take(500).collect();
|
||
+ let peak = recent.iter().map(|s| s.art).fold(f64::NEG_INFINITY, f64::max);
|
||
+ let (sys, dia, map) = sim.displayed_art_pressures(&p, false);
|
||
+ assert_eq!((dia, map), (None, None));
|
||
+ if let Some((low, high)) = limits {
|
||
+ assert!(peak >= low - 1.0 && peak <= high + 1.0,
|
||
+ "{quality:?}: waveform peak {peak}");
|
||
+ assert!(sys.is_some_and(|v| (low - 1.0..=high + 1.0).contains(&f64::from(v))));
|
||
+ } else {
|
||
+ assert!(peak <= 5.0, "bad CPR must not create a pulse");
|
||
+ assert!(sys.is_some_and(|v| (0..=5).contains(&v)));
|
||
+ }
|
||
+ }
|
||
+ }
|
||
+
|
||
+ #[test]
|
||
+ fn good_cpr_can_create_poor_pleth_in_vf_despite_admin_no_quality() {
|
||
+ let p = Parameters { ecg_rhythm: EcgRhythm::VentricularFibrillation,
|
||
+ spo2_quality: Spo2Quality::None,
|
||
+ chest_compressions_active: true,
|
||
+ chest_compression_quality: ChestCompressionQuality::Good,
|
||
+ ..Parameters::default() };
|
||
+ let mut sim = Simulator::new(&p);
|
||
+ for _ in 0..400 { sim.step(&p); }
|
||
+ assert_eq!(sim.spo2_quality(&p), Spo2Quality::Poor);
|
||
+ assert_eq!(sim.spo2_status(&p), Spo2Status::Available);
|
||
+ assert!(sim.spo2_pulse_rate(&p).is_some_and(|v| (90..=110).contains(&v)));
|
||
+ assert!(sim.samples.iter().rev().take(400).any(|s| s.pleth > 0.05 && s.pleth_valid));
|
||
+ assert!(sim.samples.iter().rev().take(400).all(|s| s.pleth_quality == Spo2Quality::Poor));
|
||
+ }
|
||
+
|
||
+ #[test]
|
||
+ fn only_good_cpr_shows_pleth_and_sensor_disconnect_takes_precedence() {
|
||
+ for quality in [ChestCompressionQuality::Adequate,
|
||
+ ChestCompressionQuality::Poor, ChestCompressionQuality::Bad] {
|
||
+ let p = Parameters { chest_compressions_active: true,
|
||
+ chest_compression_quality: quality, ..Parameters::default() };
|
||
+ let mut sim = Simulator::new(&p);
|
||
+ sim.step(&p);
|
||
+ assert_eq!(sim.spo2_status(&p), Spo2Status::NoReading);
|
||
+ assert_eq!(sim.spo2_pulse_rate(&p), None);
|
||
+ assert!(!sim.samples.back().unwrap().pleth_valid);
|
||
+ }
|
||
+ let mut p = Parameters { chest_compressions_active: true,
|
||
+ chest_compression_quality: ChestCompressionQuality::Good, ..Parameters::default() };
|
||
+ let mut sim = Simulator::new(&p);
|
||
+ p.spo2_sensor_attached = false;
|
||
+ sim.step(&p);
|
||
+ assert_eq!(sim.spo2_status(&p), Spo2Status::NoSensor);
|
||
+ assert!(!sim.samples.back().unwrap().pleth_valid);
|
||
+ }
|
||
+
|
||
+ #[test]
|
||
+ fn compressions_distort_ecg_and_preserve_intrinsic_pulses_in_sinus() {
|
||
+ let normal = Parameters::default();
|
||
+ let with_cpr = Parameters { chest_compressions_active: true,
|
||
+ chest_compression_quality: ChestCompressionQuality::Adequate,
|
||
+ ..Parameters::default() };
|
||
+ let mut base = Simulator::new(&normal);
|
||
+ let mut cpr = Simulator::new(&with_cpr);
|
||
+ let mut ecg_distortion = false;
|
||
+ let mut art_distortion = false;
|
||
+ for _ in 0..500 {
|
||
+ base.step(&normal);
|
||
+ cpr.step(&with_cpr);
|
||
+ let native = base.samples.back().unwrap();
|
||
+ let compressed = cpr.samples.back().unwrap();
|
||
+ ecg_distortion |= (compressed.ecg - native.ecg).abs() > 0.1;
|
||
+ art_distortion |= (compressed.art - native.art).abs() > 5.0;
|
||
+ }
|
||
+ assert!(ecg_distortion);
|
||
+ assert!(art_distortion);
|
||
+ assert!(cpr.samples.iter().rev().take(500).any(|s| s.art > 60.0));
|
||
+ assert_eq!(cpr.pulse_rate(), Some(75), "CPR must not change underlying HR/PR capture");
|
||
+ }
|
||
+
|
||
+ #[test]
|
||
+ fn stopping_compressions_restores_pulseless_drift_and_normal_pleth_rules() {
|
||
+ let mut p = Parameters { ecg_rhythm: EcgRhythm::Asystole,
|
||
+ chest_compressions_active: true,
|
||
+ chest_compression_quality: ChestCompressionQuality::Good,
|
||
+ ..Parameters::default() };
|
||
+ let mut sim = Simulator::new(&p);
|
||
+ assert_eq!(sim.spo2_status(&p), Spo2Status::Available);
|
||
+ p.chest_compressions_active = false;
|
||
+ sim.step(&p);
|
||
+ assert!((0.0..=5.0).contains(&sim.samples.back().unwrap().art));
|
||
+ assert_eq!(sim.spo2_status(&p), Spo2Status::NoReading);
|
||
+ assert!(!sim.samples.back().unwrap().pleth_valid);
|
||
+ assert_eq!(sim.spo2_pulse_rate(&p), None);
|
||
+ }
|
||
+
|
||
#[test]
|
||
fn signals_remain_in_expected_ranges() {
|
||
let p = Parameters::default();
|
||
diff --git a/src/ui.rs b/src/ui.rs
|
||
index 7e6fd0a..ffb8579 100644
|
||
--- a/src/ui.rs
|
||
+++ b/src/ui.rs
|
||
@@ -9,7 +9,8 @@ use gtk::prelude::*;
|
||
use gtk::{Application, ApplicationWindow, Orientation};
|
||
|
||
use crate::alarm::{self, AlarmAudio};
|
||
-use crate::model::{AlarmLimits, AlarmSettings, ArterialShape, CapnoShape, EcgRhythm, Parameters, PulseConduction, Spo2Quality};
|
||
+use crate::model::{AlarmLimits, AlarmSettings, ArterialShape, CapnoShape,
|
||
+ ChestCompressionQuality, EcgRhythm, Parameters, PulseConduction, Spo2Quality};
|
||
use crate::render;
|
||
use crate::simulation::Simulator;
|
||
|
||
@@ -186,6 +187,60 @@ fn create_admin(app: &Application, params: SharedParams,
|
||
patient_row.append(&name_entry);
|
||
patient.append(&patient_row);
|
||
|
||
+ // Resuscitation controls are deliberately near the top of the Admin panel.
|
||
+ // CSS sets the *button background*, not just its text color.
|
||
+ if let Some(display) = gdk::Display::default() {
|
||
+ let provider = gtk::CssProvider::new();
|
||
+ provider.load_from_data(
|
||
+ "button.cpr-start { background-image: none; background-color: #158742; color: #ffffff; font-weight: bold; }
|
||
+ button.cpr-stop { background-image: none; background-color: #c53035; color: #ffffff; font-weight: bold; }"
|
||
+ );
|
||
+ gtk::style_context_add_provider_for_display(
|
||
+ &display, &provider, gtk::STYLE_PROVIDER_PRIORITY_APPLICATION);
|
||
+ }
|
||
+ let cpr = group(&controls, "Chest compressions", None);
|
||
+ let compression_button = gtk::Button::with_label("Start Chest Compressions");
|
||
+ compression_button.set_hexpand(true);
|
||
+ compression_button.add_css_class("cpr-start");
|
||
+ compression_button.connect_clicked({
|
||
+ let params = params.clone();
|
||
+ move |button| {
|
||
+ let mut p = params.borrow_mut();
|
||
+ p.chest_compressions_active = !p.chest_compressions_active;
|
||
+ if p.chest_compressions_active {
|
||
+ button.set_label("Stop Chest Compressions");
|
||
+ button.remove_css_class("cpr-start");
|
||
+ button.add_css_class("cpr-stop");
|
||
+ } else {
|
||
+ button.set_label("Start Chest Compressions");
|
||
+ button.remove_css_class("cpr-stop");
|
||
+ button.add_css_class("cpr-start");
|
||
+ }
|
||
+ }
|
||
+ });
|
||
+ cpr.append(&compression_button);
|
||
+ let _quality = add_dropdown_at(&cpr, "Compression quality",
|
||
+ &["Good", "Adequate", "Poor", "Bad"], 1, params.clone(), |p, selected| {
|
||
+ p.chest_compression_quality = match selected {
|
||
+ 0 => ChestCompressionQuality::Good,
|
||
+ 2 => ChestCompressionQuality::Poor,
|
||
+ 3 => ChestCompressionQuality::Bad,
|
||
+ _ => ChestCompressionQuality::Adequate,
|
||
+ };
|
||
+ });
|
||
+ let cpr_hint = gtk::Label::new(Some(
|
||
+ "CPR: 90–110 compressions/min. ECG is distorted; ART receives compression waves. "
|
||
+ ));
|
||
+ cpr_hint.set_xalign(0.0);
|
||
+ cpr_hint.set_wrap(true);
|
||
+ cpr.append(&cpr_hint);
|
||
+ let cpr_hint2 = gtk::Label::new(Some(
|
||
+ "Only Good compressions generate a Poor-quality SpO₂/pleth signal (if the sensor is attached)."
|
||
+ ));
|
||
+ cpr_hint2.set_xalign(0.0);
|
||
+ cpr_hint2.set_wrap(true);
|
||
+ cpr.append(&cpr_hint2);
|
||
+
|
||
let ecg = group(&controls, "ECG", Some(ECG_GREEN));
|
||
add_visibility(&ecg, params.borrow().show_ecg, params.clone(), |p, show| p.show_ecg = show);
|
||
let rhythm_dropdown = add_dropdown_at(&ecg, "ECG rhythm", &[
|