v0.4.2: add PVT

This commit is contained in:
GABRIEL Sebastian 2026-11-12 12:08:46 +01:00
commit 5e397019fc
8 changed files with 727 additions and 51 deletions

View file

@ -5,15 +5,40 @@ pub enum EcgRhythm {
Sinus,
AtrialFibrillation,
VentricularTachycardia,
PulselessVentricularTachycardia,
VentricularFibrillation,
Asystole,
}
impl EcgRhythm {
/// VF and asystole have no organized QRS to trigger a mechanical pulse.
/// Organized electrical QRS complexes. PVT still has electrical QRS complexes.
pub fn has_qrs(self) -> bool {
!matches!(self, Self::VentricularFibrillation | Self::Asystole)
}
/// Whether a QRS can trigger a mechanical pulse, depending on capture.
/// Perfusing VT is distinct from PVT. VF and asystole have no QRS.
pub fn can_generate_pulse(self) -> bool {
self.has_qrs() && self != Self::PulselessVentricularTachycardia
}
/// Rhythm alarms are independent of instructor-defined HR thresholds.
pub fn rhythm_alarm(self) -> Option<&'static str> {
match self {
Self::VentricularTachycardia | Self::PulselessVentricularTachycardia
| Self::VentricularFibrillation => Some("ARRHYTHMIA"),
Self::Asystole => Some("ASYSTOLE"),
_ => None,
}
}
}
/// Pulse-oximeter availability and technical alarms. Sensor loss takes precedence.
#[derive(Clone, Copy, Debug, PartialEq, Eq)]
pub enum Spo2Status {
Available,
NoSensor,
NoReading,
}
#[derive(Clone, Copy, Debug, PartialEq, Eq)]
@ -195,6 +220,24 @@ pub struct Parameters {
pub show_nibp: bool,
}
impl Parameters {
/// No saturation without an attached sensor, usable signal quality and
/// two observed mechanical pulse events. Thresholds do not control this alarm.
pub fn spo2_status(&self, pulse_rate: Option<i32>) -> Spo2Status {
if !self.spo2_sensor_attached {
Spo2Status::NoSensor
} else if self.spo2_quality == Spo2Quality::None || pulse_rate.is_none()
|| !self.ecg_rhythm.can_generate_pulse()
|| self.pulse_conduction == PulseConduction::None
|| self.heart_rate <= 0
{
Spo2Status::NoReading
} else {
Spo2Status::Available
}
}
}
impl Default for Parameters {
fn default() -> Self {
Self {
@ -308,6 +351,41 @@ mod tests {
assert!(!p.alarms.pr.enabled());
}
#[test]
fn vt_stays_perfusing_and_pvt_is_electrically_organized_but_pulseless() {
use EcgRhythm::*;
assert!(VentricularTachycardia.has_qrs());
assert!(VentricularTachycardia.can_generate_pulse());
assert!(PulselessVentricularTachycardia.has_qrs());
assert!(!PulselessVentricularTachycardia.can_generate_pulse());
assert!(!VentricularFibrillation.can_generate_pulse());
assert!(!Asystole.can_generate_pulse());
for rhythm in [VentricularTachycardia, PulselessVentricularTachycardia, VentricularFibrillation] {
assert_eq!(rhythm.rhythm_alarm(), Some("ARRHYTHMIA"));
}
assert_eq!(Asystole.rhythm_alarm(), Some("ASYSTOLE"));
assert_eq!(Sinus.rhythm_alarm(), None);
assert_eq!(AtrialFibrillation.rhythm_alarm(), None);
}
#[test]
fn sensor_and_no_reading_alarms_override_spo2_thresholds() {
let mut p = Parameters::default();
assert_eq!(p.spo2_status(Some(80)), Spo2Status::Available);
assert_eq!(p.spo2_status(None), Spo2Status::NoReading);
p.spo2_quality = Spo2Quality::None;
assert_eq!(p.spo2_status(Some(80)), Spo2Status::NoReading);
p.spo2_sensor_attached = false;
assert_eq!(p.spo2_status(Some(80)), Spo2Status::NoSensor);
p.spo2_sensor_attached = true;
p.spo2_quality = Spo2Quality::Good;
p.ecg_rhythm = EcgRhythm::PulselessVentricularTachycardia;
assert_eq!(p.spo2_status(Some(80)), Spo2Status::NoReading);
p.ecg_rhythm = EcgRhythm::Sinus;
p.pulse_conduction = PulseConduction::None;
assert_eq!(p.spo2_status(Some(80)), Spo2Status::NoReading);
}
#[test]
fn grouped_mechanical_capture_follows_requested_patterns() {
assert_eq!((1..=8).filter(|&b| PulseConduction::TwoToOne.conducts(b)).collect::<Vec<_>>(),